Cited by 325Diabetes Management and ResearchDiabetes, Cardiovascular Risks, and LipoproteinsDiabetes and associated disorders

Comparison of fasting and 2-hour glucose and HbA1c levels for diagnosing diabetes. Diagnostic criteria and performance revisited

Engelgau, Michael M, Thompson, Theodore J, Herman, William H, Boyle, James P, Aubert, Ronald E, Kenny, Susan J, Badran, Ahmed, Sous, Edward S +1 more·1997·Diabetes Care

Abstract

OBJECTIVE: Nearly two decades ago, the National Diabetes Data Group (NDDG) and the World Health Organization (WHO) Expert Committee on Diabetes Mellitus published diagnostic criteria for diabetes. We undertook this study to compare the performance of three glycemic measures for diagnosing diabetes and to evaluate the performance of the WHO criteria. RESEARCH DESIGN AND METHODS: In a cross-sectional population-based sample of 1,018 Egyptians ≥ 20 years of age, fasting and 2-h glucose and HbA1c levels were measured, and diabetic retinopathy was assessed by retinal photograph. Evidence for bimodal distributions was examined for each glycemic measure by fitting models for the mixture of two distributions using maximum likelihood estimates. Sensitivity and specificity for cutpoints of each glycemic measure were calculated by defining the true diabetes state (gold standard) as 1) the upper (diabetic) component of the fitted bimodal distribution for each glycemic measure, and 2) the presence of diabetic retinopathy. Receiver operating characteristic (ROC) curves were constructed to determine the performance of the glycemic measures in detecting diabetes as defined by diabetic retinopathy. RESULTS: In the total population, the point of intersection of the lower and upper components that minimized misclassification for the fasting and 2-h glucose and HbA1c were 7.2 mmol/l (129 mg/dl), 11.5 mmol/l (207 mg/dl), and 6.7%, respectively. When diabetic retinopathy was used to define diabetes, ROC curve analyses found that fasting and 2-h glucose values were superior to HbA1c (P < 0.01). The performance of a fasting glucose of 7.8 mmol/l (140 mg/dl) was similar to a 2-h glucose of 12.2–12.8 mmol/l (220–230 mg/dl), and the performance of a 11.1 mmol/l (200 mg/dl) 2-h glucose was similar to a fasting glucose of 6.9–7.2 mmol/l (125–130 mg/dl). CONCLUSIONS: Optimal cutpoints for defining diabetes differ according to how diabetes itself is defined. When diabetes is defined as the upper component of the bimodal population distribution, a fasting glucose level somewhat lower than the current WHO cutpoint and a 2-h glucose level somewhat higher than the current WHO cutpoint minimized misclassification. When diabetic retinopathy defines diabetes, we found that the current fasting diagnostic criterion favors specificity and the current 2-h criterion favors sensitivity. These results should prove valuable for defining the optimal tests and cutpoint values for diagnosing diabetes.

Integrity signals

Registry

Crossref · 10.2337/diacare.20.5.785

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Still being checked.

Cited by

Sorted by citations

Authors
Engelgau, M. M., Thompson, T. J., Herman, W. H., Boyle, J. P., Aubert, R. E., Kenny, S. J., Badran, A., Sous, E. S., & Ali, M. A.
Affiliations
  • Centers for Disease Control and Prevention (US)
  • University of Michigan (US)
  • IQVIA (United States) (US)
  • Ministry of Health and Population (EG)
Venue
Diabetes Care
Published
1997-05-01
Volume
20
Issue
5
Pages
785-791
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2013076312
Cited by
325
References
0
Citations by year
2026: 5 · 2025: 2 · 2024: 7 · 2023: 3 · 2022: 8 · 2021: 8 · 2020: 10 · 2019: 9 · 2018: 12 · 2017: 16 · 2016: 11 · 2015: 8 · 2014: 18 · 2013: 13 · 2012: 15
FWCI
10.21
Type
journal article
Language
en
Open access
closed
Locations
  • Diabetes Care (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes, Cardiovascular Risks, and Lipoproteins
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
Keywords
diabetes diagnosis, fasting blood glucose, 2-hour plasma glucose, HbA1c, diagnostic criteria, WHO criteria, diabetic retinopathy, bimodal distribution, sensitivity and specificity, Egyptian population, diabetes prevalence
MeSH terms
Adult, Blood Glucose, Cross-Sectional Studies, Diabetes Mellitus, Diabetic Retinopathy, Egypt, Fasting, Glucose Tolerance Test, Glycated Hemoglobin, Humans, Sensitivity and Specificity, Models, Statistical

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review