Dermal Interstitial Glucose as an Indicator of Ambient Glycemia
The DOI matches its Crossref record.
Abstract
OBJECTIVE: Using a novel minimally invasive (≤ 1.4 mm) technique to sample minuscule (0.5 microliter) amounts of dermal interstitial fluid (ISF), we assessed the accuracy of its glucose concentrations in predicting concurrently measured venous plasma and capillary plasma glucose concentrations. RESEARCH DESIGN AND METHODS: A total of 67 adult (37 male and 30 female) volunteers (57 with and 10 without diabetes) with venous plasma glucose levels from 1.6 to 28.4 mmol/l underwent forearm ISF, antecubetal venous, and fingertip capillary sampling. RESULTS: Rank correlations were 0.974 for ISF 1 vs. 2, 0.954 for ISF vs. venous, 0.935 for ISF vs. capillary, and 0.987 for venous vs. capillary. Median absolute differences were 0.53 mmol/l for ISF 1 vs. 2, 1.33 mmol/l for ISF vs. venous, 1.06 mmol/l for ISF vs. capillary, and 0.56 mmol/l for capillary vs. venous. Equations expressing ISF glucose as a function of venous and capillary glucose and equations expressing capillary glucose as a function of venous glucose had slopes of 0.995, 0.936, and 1.021, respectively (none significantly different from unity), and intercepts of 1.03 mmol/l (P = 0.024), 0.94 mmol/l (P = 0.131), and 0.56 mmol/l (P = 0.041), respectively. Error grid analysis of ISF vs. venous glucose and of capillary vs. venous glucose showed that 97% of the measurements fell within grids A and B. CONCLUSIONS: Dermal ISF sampling is a bloodless minimally invasive technique that provides a medium for glucose measurement, the concentrations of which closely reflect ambient glycemia to a degree comparable with that of capillary glucose measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Parkes, J. L., Slatin, S. L., Pardo, S., & Ginsberg, B. H. (2000) · Diabetes Care · doi:10.2337/diacare.23.8.1143 · Cited by 620
Rebrin, K., Steil, G. M., van Antwerp, W. P., & Mastrototaro, J. J. (1999) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1999.277.3.e561 · Cited by 366
Minimally Invasive Extraction of Dermal Interstitial Fluid for Glucose Monitoring Using Microneedles
Wang, P. M., Cornwell, M., & Prausnitz, M. R. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.131 · Cited by 267
Accuracy of the 5-Day FreeStyle Navigator Continuous Glucose Monitoring System
Weinstein, R. L., Schwartz, S. L., Brazg, R. L., Bugler, J. R., Peyser, T. A., & McGarraugh, G. V. (2007) · Diabetes Care · doi:10.2337/dc06-1602 · Cited by 228
“glucose concentration in the interstitial fluid, which is well correlated with blood glucose (12,13).”
BackgroundCan Interstitial Glucose Assessment Replace Blood Glucose Measurements?
Rebrin, K., & Steil, G. M. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050194332 · Cited by 213
Advances in Photoacoustic Noninvasive Glucose Testing
MacKenzie, H. A., Ashton, H. S., Spiers, S., Shen, Y., Freeborn, S. S., Hannigan, J., Lindberg, J., & Rae, P. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1587 · Cited by 186
“Other noninvasive approaches attempt to use a correlation between glucose content in interstitial fluid and capillary blood ( 24 ). The use of a patch or reservoir on the skin surface to collect glucose has also been explored (25 ).”
Thennadil, S. N., Rennert, J. L., Wenzel, B. J., Hazen, K. H., Ruchti, T. L., & Block, M. B. (2001) · Diabetes Technology & Therapeutics · doi:10.1089/15209150152607132 · Cited by 166
Overview on self-monitoring of blood glucose
Montagnana, M., Caputo, M., Giavarina, D., & Lippi, G. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.01.002 · Cited by 116
Venugopal, M., Feuvrel, K. E., Mongin, D., Bambot, S., Faupel, M., Panangadan, A., Talukder, A., & Pidva, R. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2007.912544 · Cited by 76
“For instance, regular blood glucose monitoring is the primary means of ensuring glycemic control in diabetics [ 1 ].”
BackgroundAssessment of transcapillary glucose exchange in human skeletal muscle and adipose tissue
Regittnig, W., Ellmerer, M., Fauler, G., Sendlhofer, G., Trajanoski, Z., Leis, H.-J., Schaupp, L., Wach, P., & Pieber, T. R. (2003) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00351.2002 · Cited by 41
Heinemann, L., Krämer, U., Klötzer, H.-M., Hein, M., Volz, D., Hermann, M., Heise, T., & Rave, K. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050025168 · Cited by 34
Metadata
- Authors
- Service, F. J., O'Brien, P. C., Wise, S. D., Ness, S., & LeBlanc, S. M.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 1997-09-01
- Volume
- 20
- Issue
- 9
- Pages
- 1426-1429
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W1964063750
- Cited by
- 48
- References
- 0
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.