Comparison of Human Regular and Lispro Insulins After Interruption of Continuous Subcutaneous Insulin Infusion and in the Treatment of Acutely Decompensated IDDM
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To compare the rapidity of metabolic decompensation after interruption of CSII between human regular and lispro insulin and to compare these two insulins in the correction of the hyperglycemia and ketosis of mildly decompensated IDDM. Lispro insulin may be especially useful for insulin pump therapy (continuous subcutaneous insulin infusion [CSII]). RESEARCH DESIGN AND METHODS: A total of 18 patients with well-controlled IDDM (HbA1c 7.7 ± 1.1%, age 30 ± 11 years) were studied. All were being treated with CSII (nine with human regular and nine with lispro insulin). The study consisted of two phases: 1) an insulin interruption phase, in which the basal insulin infusion was stopped (at 0300) and plasma insulin, glucose, and β-O-hydroxybutyrate (β-OHB) were measured every 15–60 min for 6 h after interruption of the insulin infusion and 2) an insulin replacement phase, which involved measuring plasma insulin, glucose, and (β-OHB for 2 h after a single injection of either human regular or lispro insulin to correct the hyperglycemia and ketosis that developed during the first phase of the study. RESULTS: After interruption of the basal insulin infusion during the insulin interruption phase, plasma insulin levels fell gradually in both groups to nadir values of 1.6 ± 0.8 and 2.0 ±1.2 μU/ml in the regular insulin- and insulin lispro-treated groups, respectively. Plasma glucose concentrations rose to 13.8 ±1.9 and 16.0 ±1.7 mmol/1 in the regular insulin- and insulin lispro-treated groups, respectively. No significant differences were seen between the therapy groups at any time in the insulin levels or in the concentrations of plasma glucose or (β-OHB. In the insulin replacement phase, insulin levels rose more rapidly in those treated with lispro insulin, reaching a greater peak value (e.g., at 60 min, plasma insulin 25 ± 3.4 vs. 15.6 ± 2.6 μUsol;ml, P < 0.05). In association with this, plasma glucose decreased to a lower nadir after lispro insulin (9.7 ± 0.4 vs. 13.7 ± 0.7 mmol/1, lispro- vs. regular-treated groups at 120 min after insulin administration, P <0.01). β-OHB levels decreased rapidly in both groups. CONCLUSIONS: In patients treated with CSII, interruption of the basal insulin infusion in the middle of the night does not result in more rapid metabolic decompensation in patients treated with lispro compared with those treated with regular human insulin. Lispro insulin is effective in treating mild ketosis and hyperglycemia, and its rapid action may be advantageous in the “sick day” management at home of patients with IDDM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“From a clinical point of view, insulin retention for up to 6 hours is supposed to be acceptable;4-7”
From Occlusion Detection Time in Insulin Pumps at Two Different Basal Rates (2018) · cites this paper as [6]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enzymic determination of d(−)-β-hydroxybutyric acid and acetoacetic acid in blood
WILLIAMSON, D., MELLANBY, J., & KREBS, H. (1962) · Biochemical Journal · doi:10.1042/bj0820090 · Cited by 1,397
[Lys(B28), Pro(B29)]-Human Insulin: A Rapidly Absorbed Analogue of Human Insulin
Howey, D. C., Bowsher, R. R., Brunelle, R. L., & Woodworth, J. R. (1994) · Diabetes · doi:10.2337/diab.43.3.396 · Cited by 472
Insulin Lispro in CSII: Results of a Double-Blind Crossover Study
Zinman, B., Tildesley, H., Chiasson, J.-L., Tsui, E., & Strack, T. (1997) · Diabetes · doi:10.2337/diab.46.3.440 · Cited by 258
Torlone, E., Fanelli, C. G., Rambotti, A. M., Kassi, G., Modarelli, F., Vincenzo, A. D., Epifano, L., Ciofetta, M., Pampanelli, S., Brunetti, P., et al. (1994) · Diabetologia · doi:10.1007/bf00417697 · Cited by 136
DiMarchi, R. D., Chance, R. E., Long, H. B., Shields, J. E., & Slieker, L. J. (2008) · Hormone Research · doi:10.1159/000183967 · Cited by 85
Castillo, M. J., Scheen, A. J., & Lefèbvre, P. J. (1996) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.81.5.1975 · Cited by 15
Cited by
Insulin analogues and their potential in the management of diabetes mellitus
Bolli, G. B., Di Marchi, R. D., Park, G. D., Pramming, S., & Koivisto, V. A. (1999) · Diabetologia · doi:10.1007/s001250051286 · Cited by 349
Continuous Subcutaneous Insulin Infusion: A Comprehensive Review of Insulin Pump Therapy
Lenhard, M. J., & Reeves, G. D. (2001) · Archives of Internal Medicine · doi:10.1001/archinte.161.19.2293 · Cited by 205
Recombinant DNA Technology in the Treatment of Diabetes: Insulin Analogs
Vajo, Z., Fawcett, J., & Duckworth, W. C. (2001) · Endocrine Reviews · doi:10.1210/edrv.22.5.0442 · Cited by 172
A Randomized Trial of a Home System to Reduce Nocturnal Hypoglycemia in Type 1 Diabetes
Maahs, D. M., Calhoun, P., Buckingham, B. A., Chase, H. P., Hramiak, I., Lum, J., Cameron, F., Bequette, B. W., Aye, T., Paul, T., et al. (2014) · Diabetes Care · doi:10.2337/dc13-2159 · Cited by 160
Mukhopadhyay, A., Farrell, T., Fraser, R. B., & Ola, B. (2007) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2007.03.062 · Cited by 153
Metadata
- Authors
- Attia, N., Jones, T. W., Holcombe, J., & Tamborlane, W. V.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 1998-05-01
- Volume
- 21
- Issue
- 5
- Pages
- 817-821
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2052407546
- Cited by
- 98
- References
- 6
- FWCI
- 3.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.