CoChat

A Randomized Trial of Continuous Subcutaneous Insulin Infusion and Intensive Injection Therapy in Type 1 Diabetes for Patients With Long-Standing Poor Glycemic Control

Open access
DeVries, J. Hans, Snoek, Frank J., Kostense, Piet J., Masurel, Nathalie, Heine, Robert J., On behalf of the Dutch Insulin Pump Study Group · 2002 · Diabetes Care
Cited by 187

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Abstract

OBJECTIVE—To assess in a randomized crossover trial the efficacy of continuous subcutaneous insulin infusion in improving glycemic control and health-related quality of life in type 1 diabetic patients with long-standing poor glycemic control. RESEARCH DESIGN AND METHODS—A total of 79 patients in 11 Dutch centers were randomized to 16 weeks of continuous subcutaneous insulin infusion followed by 16 weeks intensive injection therapy or the reverse order. Glycemic control was assessed by HbA1c, self-reported hypoglycemic events, and blood glucose memory meter read outs. Changes in quality of life were assessed by self-report questionnaires administered at baseline and 16 weeks. RESULTS—As the drop-out rate after crossover was high (17 of 79 patients [22%]), we analyzed the trial as a parallel clinical trial, using data of the first half of the crossover phase only. At 16 weeks, mean HbA1c was 0.84% (95% CI −1.31 to −0.36) lower in the continuous subcutaneous insulin infusion group compared with the insulin injection group (P = 0.002). Stability of blood glucose self-measurement values, expressed as SD of the nine-point blood glucose profiles, improved in the insulin pump group by 29.3 ± 41.1 vs. 8.2 ± 36.5% in the injection group (P = 0.039). The number of mild hypoglycemic episodes per patient-week was 0.99 (95% CI 0.11–1.87) higher in the insulin pump group (P = 0.028). Weight gain was similar in both groups. Scores on the Short-Form 36-Item subscales ‘general health’ and ‘mental health’ improved in the continuous subcutaneous insulin infusion group, compared with stable values in the injection group (P = 0.048 and 0.050, respectively). CONCLUSIONS—Continuous subcutaneous insulin infusion improves glycemic control and some aspects of health-related quality of life in patients with a history of long-term poor glycemic control.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diacare.25.11.2074

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 187

Metadata

Authors
DeVries, J. H., Snoek, F. J., Kostense, P. J., Masurel, N., Heine, R. J., & On behalf of the Dutch Insulin Pump Study Group
Venue
Diabetes Care
Published
2002-11-01
Volume
25
Issue
11
Pages
2074-2080
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2108311162
Cited by
187
References
30
FWCI
6.52
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.