Cited by 16Neuroscience and Neural EngineeringAnalog and Mixed-Signal Circuit DesignMuscle activation and electromyography studies

Intraneural active probe for bidirectional peripheral nerve interface

Ballini, Marco, Bae, Joonsung, Marrocco, Nicola, Verplancke, Rik, Schaubroeck, David, Cuypers, Dieter, Cauwe, Maarten, O'Callaghan, John +8 more·2017·2017 Symposium on VLSI Circuits

Abstract

Advanced bionic prosthetics that can restore both the motor functionality and sensory perception of an amputee, require high-resolution recording and stimulation interfaces targeting the peripheral nervous system (PNS). To provide high nerve fiber selectivity, we propose a low-noise (3.67μVrms) low-power (2.24mW) and high-density CMOS microelectrode probe for intra-neural implantation. The probe is composed of two ICs, encapsulated in a biocompatible and hermetic package, each featuring 64 recording and 16 stimulation electrodes. A backend IC digitizes the recorded signals at 31.25kS/s and provides spike detection.

Integrity signals

Registry

Crossref · 10.23919/vlsic.2017.8008544

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Passive methods of charge balancing are commonly used to discharge the electrodes to a reference node following each stimulus pulse, provided that the stimulator IC can afford the necessary overhead area or time to achieve this.

    “Passive methods of charge balancing are commonly used to discharge the electrodes to a reference node following each stimulus pulse, provided that the stimulator IC can afford the necessary overhead area or time to achieve this [67], [69].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ballini, M., Bae, J., Marrocco, N., Verplancke, R., Schaubroeck, D., Cuypers, D., Cauwe, M., O'Callaghan, J., Fahmy, A., Maghari, N., Bashirullah, R., Van Hoof, C., Van Helleputte, N., de Beeck, M. O., Braeken, D., & Mitra, S.
Affiliations
  • IMEC (BE)
  • Ghent University (BE)
  • University of Florida (US)
Venue
2017 Symposium on VLSI Circuits
Publisher
IEEE
Published
2017-06
Pages
C50-C51
ISSN
2166-9600 (ISSN-L)
OpenAlex
W2743629223
Cited by
16
References
3
Citations by year
2025: 1 · 2024: 4 · 2022: 1 · 2021: 4 · 2020: 1 · 2019: 3 · 2018: 1 · 2017: 1
FWCI
6.40
Type
conference paper
Language
en
Open access
closed
Locations
  • Symposium on VLSI Circuits (publishedVersion)
  • Ghent University Academic Bibliography (Ghent University) (submittedVersion)
Funders
  • Defense Advanced Research Projects Agency (N66001-15-C-4018)
  • Advanced Research Projects Agency
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
peripheral nerve interfaces, CMOS microelectrode array, neuroprosthetics, spike detection, high-density electrode arrays

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review