The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
PET/MRI Dual-Modality Tumor Imaging Using Arginine-Glycine-Aspartic (RGD)–Conjugated Radiolabeled Iron Oxide Nanoparticles
Open accessAbstract
UNLABELLED: The purpose of this study was to develop a bifunctional iron oxide (IO) nanoparticle probe for PET and MRI scans of tumor integrin alphavbeta3 expression. METHODS: Polyaspartic acid (PASP)-coated IO (PASP-IO) nanoparticles were synthesized using a coprecipitation method, and particle size and magnetic properties were measured. A phantom study was used to assess the efficacy of PASP-IO as a T2-weighted MRI contrast agent. PASP-IO nanoparticles with surface amino groups were coupled to cyclic arginine-glycine-aspartic (RGD) peptides for integrin alphavbeta3 targeting and macrocyclic 1,4,7,10-tetraazacyclododecane-N,N',N'',N''',-tetraacetic acid (DOTA) chelators for PET after labeling with 64Cu. IO nanoparticle conjugates were further tested in vitro and in vivo to determine receptor targeting efficacy and feasibility for dual PET/MRI. RESULTS: PASP-IO nanoparticles made by single-step reaction have a core size of 5 nm with a hydrodynamic diameter of 45 +/- 10 nm. The saturation magnetization of PASP-IO nanoparticles is about 117 emu/g of iron, and the measured r2 and r2* are 105.5 and 165.5 (s.mM)(-1), respectively. A displacement competitive binding assay indicates that DOTA-IO-RGD conjugates bound specifically to integrin alphavbeta3 in vitro. Both small-animal PET and T2-weighted MRI show integrin-specific delivery of conjugated RGD-PASP-IO nanoparticles and prominent reticuloendothelial system uptake. CONCLUSION: We have successfully developed an IO-based nanoprobe for simultaneous dual PET and MRI of tumor integrin expression. The success of this bifunctional imaging approach may allow for earlier tumor detection with a high degree of accuracy and provide further insight into the molecular mechanisms of cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Renal clearance of quantum dots
Soo Choi, H., Liu, W., Misra, P., Tanaka, E., Zimmer, J. P., Itty Ipe, B., Bawendi, M. G., & Frangioni, J. V. (2007) · Nature Biotechnology · doi:10.1038/nbt1340 · Cited by 4,476 · cited 1×
“One possibility is the comparatively large hydrodynamic size (;45 nm), whereas it is more desirable to get the particle size down to 5–10 nm (32) to achieve more efficient extravasation.”
BackgroundA combined PET/CT scanner for clinical oncology.
Beyer, T., Townsend, D. W., Brun, T., Kinahan, P. E., Charron, M., Roddy, R., Jerin, J., Young, J., Byars, L. G., & Nutt, R. (2000) · PubMed · Cited by 1,659
Molecular imaging of cancer with positron emission tomography
Gambhir, S. S. (2002) · Nature Reviews Cancer · doi:10.1038/nrc882 · Cited by 1,656
Peptide-Labeled Near-Infrared Quantum Dots for Imaging Tumor Vasculature in Living Subjects
Cai, W., Shin, D.-W., Chen, K., Gheysens, O., Cao, Q., Wang, S. X., Gambhir, S. S., & Chen, X. (2006) · Nano Letters · doi:10.1021/nl052405t · Cited by 948
Self-citationImage registration by maximization of combined mutual information and gradient information
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.876307 · Cited by 670
MicroPET: a high resolution PET scanner for imaging small animals
Cherry, S. R., Shao, Y., Silverman, R. W., Meadors, K., Siegel, S., Chatziioannou, A., Young, J. W., Jones, W., Moyers, J. C., Newport, D., et al. (1997) · IEEE Transactions on Nuclear Science · doi:10.1109/23.596981 · Cited by 609
Nanoplatforms for Targeted Molecular Imaging in Living Subjects
Cai, W., & Chen, X. (2007) · Small · doi:10.1002/smll.200700351 · Cited by 563
Self-citation(2005) · PubMed · Cited by 395
Multivalent Effects of RGD Peptides Obtained by Nanoparticle Display
Montet, X., Funovics, M., Montet-Abou, K., Weissleder, R., & Josephson, L. (2006) · Journal of Medicinal Chemistry · doi:10.1021/jm060515m · Cited by 388
Simultaneous PET and MR imaging
Shao, Y., Cherry, S. R., Farahani, K., Meadors, K., Siegel, S., Silverman, R. W., & Marsden, P. K. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/10/010 · Cited by 374
In vivo Near-Infrared Fluorescence Imaging of Integrin αvβ3 in Brain Tumor Xenografts
Chen, X., Conti, P. S., & Moats, R. A. (2004) · Cancer Research · doi:10.1158/0008-5472.can-04-1956 · Cited by 347
Self-citationUse of PET for monitoring cancer therapy and for predicting outcome.
Weber, W. (2005) · PubMed · Cited by 341
Zhang, C., Jugold, M., Woenne, E. C., Lammers, T., Morgenstern, B., Mueller, M. M., Zentgraf, H., Bock, M., Eisenhut, M., Semmler, W., et al. (2007) · Cancer Research · doi:10.1158/0008-5472.can-06-1668 · Cited by 336
Wu, Y., Zhang, X., Xiong, Z., Cheng, Z., Fisher, D. R., Liu, S., Gambhir, S. S., & Chen, X. S. (2005) · PubMed · Cited by 325
Self-citationA combined PET/CT scanner: the path to true image fusion
Townsend, D. W., & Beyer, T. (2002) · The British Journal of Radiology · doi:10.1259/bjr.75.suppl_9.750024 · Cited by 241
Hahn, P. F., Stark, D. D., Lewis, J. M., Saini, S., Elizondo, G., Weissleder, R., Fretz, C. J., & Ferrucci, J. T. (1990) · Radiology · doi:10.1148/radiology.175.3.2343116 · Cited by 181
Fast and robust registration of PET and MR images of human brain
Čı́žek, J., Herholz, K., Vollmar, S., Schrader, R., Klein, J., & Heiss, W.-D. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.01.016 · Cited by 172
Detection of recurrent pancreatic cancer: Comparison of FDG-PET with CT/MRI
Ruf, J., Hänninen, E. L., Oettle, H., Plotkin, M., Pelzer, U., Stroszczynski, C., Felix, R., & Amthauer, H. (2005) · Pancreatology · doi:10.1159/000085281 · Cited by 167
Dual-modality PET/CT tomography for clinical oncology.
Beyer, T., Townsend, D. W., & Blodgett, T. M. (2002) · PubMed · Cited by 137
PET-CT detection of abdominal recurrence of ovarian cancer: radiologic?surgical correlation
Pannu, H. K., Cohade, C., Bristow, R. E., Fishman, E. K., & Wahl, R. L. (2004) · Abdominal Imaging · doi:10.1007/s00261-003-0118-7 · Cited by 78
Phantom validation of coregistration of PET and CT for image‐guided radiotherapy
Lavely, W. C., Scarfone, C., Çevıkalp, H., Li, R., Byrne, D. W., Cmelak, A. J., Dawant, B. M., Price, R. R., Hallahan, D. E., & Fitzpatrick, J. M. (2004) · Medical Physics · doi:10.1118/1.1688041 · Cited by 69
Lanthanide-Loaded Liposomes for Multimodality Imaging and Therapy
Zielhuis, S. W., Seppenwoolde, J., Mateus, V., Bakker, C. J. G., Krijger, G. C., Storm, G., Zonnenberg, B. A., Schip, A. D. V. H., Koning, G. A., & Nijsen, J. F. W. (2006) · Cancer Biotherapy and Radiopharmaceuticals · doi:10.1089/cbr.2006.21.520 · Cited by 57
Xiong, Z., Cheng, Z., Zhang, X., Patel, M., Wu, J. C., Gambhir, S. S., & Chen, X. S. (2006) · PubMed · Cited by 54
Self-citationPrompruk, K., Govender, T., Zhang, S., Xiong, C. D., & Stolnik, S. (2005) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2005.02.025 · Cited by 51
Saeed, M., Wendland, M. F., Engelbrecht, M. R. W., Sakuma, H., & Higgins, C. B. (1998) · European Radiology · doi:10.1007/s003300050512 · Cited by 47
Coronary MR Angiography: Experimental Results with a Monomer-stabilized Blood Pool Contrast Medium
Taupitz, M., Schnorr, J., Wagner, S., Abramjuk, C., Pilgrimm, H., Kivelitz, D. E., Schink, T., Hansel, J., Laub, G. A., Hünigen, H., et al. (2002) · Radiology · doi:10.1148/radiol.2221001452 · Cited by 44
Magnetic resonance and fluorescence based molecular imaging technologies
Sosnovik, D. E., & Weissleder, R. (2005) · Birkhäuser Basel eBooks · doi:10.1007/3-7643-7426-8_3 · Cited by 38
Ferrimagnetic susceptibility contrast agents.
Bach-Gansmo, T. (1993) · PubMed · Cited by 29
The application of PET–MR image registration in the brain
Myers, R. (2002) · British Journal of Radiology · doi:10.1259/bjr.75.suppl_9.750031 · Cited by 25
Cited by
Aggregation-Induced Emission: Together We Shine, United We Soar!
Mei, J., Leung, N. L. C., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00263 · Cited by 8,270
Green synthesis of metal nanoparticles using plants
Iravani, S. (2011) · Green Chemistry · doi:10.1039/c1gc15386b · Cited by 3,823
Multifunctional Magnetic Nanoparticles: Design, Synthesis, and Biomedical Applications
Gao, J., Gu, H., & Xu, B. (2009) · Accounts of Chemical Research · doi:10.1021/ar9000026 · Cited by 1,907
Design and fabrication of magnetic nanoparticles for targeted drug delivery and imaging
Veiseh, O., Gunn, J. W., & Zhang, M. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.11.002 · Cited by 1,832
Nanochemistry and Nanomedicine for Nanoparticle-based Diagnostics and Therapy
Chen, G., Roy, I., Yang, C., & Prasad, P. N. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00148 · Cited by 1,499
Metadata
- Authors
- Lee, H.-Y., Li, Z., Chen, K., Hsu, A. R., Xu, C., Xie, J., Sun, S., & Chen, X.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2008-07-16
- Volume
- 49
- Issue
- 8
- Pages
- 1371-1379
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2108340668
- Cited by
- 557
- References
- 29
- FWCI
- 29.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.