Research Progress of Noninvasive Cardiac Output Monitor (NICOTM) and Hemodynamic Monitor in Neonates
Open accessAbstract
Objective: Hemodynamic monitoring plays a crucial way in guiding the clinical decision-making process for the management of critically ill neonates. Noninvasive hemodynamic monitoring is characterized by continuous, convenient, and accurate assessment, presenting a viable option for implementation in neonatal intensive care units (NICU). This review article summarizes the research advancements made in noninvasive hemodynamic monitoring and electronic cardiometry (EC) applications in neonates, providing valuable reference resource for studies in the field of hemodynamic monitoring. Mechanism: The clinical significance of hemodynamic monitoring in neonates is first introduced and followed by a comprehensive description of both invasive and noninvasive techniques employed in hemodynamic monitoring. Furthermore, the research progress of EC in neonates is discussed, focusing particularly on its feasibility and accuracy. Finally, the application and influencing factors of EC in diverse diseases, encompassing neonatal conditions, are presented. Findings in Brief: Due to the risks associated with invasive cardiac output monitoring, noninvasive or minimally invasive alternative techniques are needed for hemodynamic monitoring. In recent years, noninvasive and minimally invasive techniques, such as ultrasound cardiac output monitor (USCOM) and impedance cardiography have been utilized. EC, as an impedance-based monitoring, facilitates noninvasive and real-time assessment of hemodynamic parameters. The integration of EC enables real-time and continuous monitoring of dynamic changes in cardiac and vascular functions in patients, thereby assisting in clinical evaluation and guiding the clinical decision-making. Conclusion: EC is a noninvasive, highly sensitive, and accurate monitoring technique that holds important guiding significance in clinical practice.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
EC has shown strong agreement with transthoracic echocardiography regarding stroke volume, stroke volume variation, and the inferior vena cava distensibility index.
“Moreover, EC has shown strong agreement with transthoracic echocardiography regarding stroke volume, stroke volume variation (SVV), and the inferior vena cava distensibility index (dIVC) [71].”
From Trends and Challenges in Noninvasive Hemodynamic Monitoring of Neonates Following Cardiac Surgery: A Narrative Review (2025) · cites this paper as [71]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Critchley, L. A. H., & Critchley, J. (1999) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009982611386 · Cited by 1,328 · see citing works
Development and evaluation of an impedance cardiac output system.
Kubicek, W. G., Karnegis, J. N., PATTERSON, R. P., Witsoe, D. A., & Mattson, R. H. (1966) · PubMed · Cited by 1,143 · see citing works
Pathophysiology and Treatment of Septic Shock in Neonates
Wynn, J. L., & Wong, H. R. (2010) · Clinics in Perinatology · doi:10.1016/j.clp.2010.04.002 · Cited by 260 · cited 1× · see citing works
“However, studies have shown that blood pressure, capillary refill time and urine volume are not well correlated with systemic blood flow [ 2,3].”
BackgroundNoori, S., Drabu, B., Soleymani, S., & Seri, I. (2012) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/fetalneonatal-2011-301090 · Cited by 146 · see citing works
Circulatory support of the sick preterm infant
Seri, I. (2001) · Seminars in Neonatology · doi:10.1053/siny.2000.0034 · Cited by 134 · cited 1× · see citing works
“Seri I [5] notes that the management of critically ill premature infants with hypotension remains challenging, requiring a better understanding of the pathophysiology of neonatal shock, and improving our ability to assess cardiac output, organ blood flow, and tissue perfusion at the bedside.”
BackgroundNeonatal Hemodynamics: From Developmental Physiology to Comprehensive Monitoring
Vrancken, S. L. A. G., van Heijst, A. F. J., & de Boode, W. P. (2018) · Frontiers in Pediatrics · doi:10.3389/fped.2018.00087 · Cited by 123 · cited 1× · see citing works
“However, studies have shown that blood pressure, capillary refill time and urine volume are not well correlated with systemic blood flow [ 2,3].”
BackgroundGolden hour of neonatal life: Need of the hour
Sharma, D. K. (2017) · Maternal Health Neonatology and Perinatology · doi:10.1186/s40748-017-0057-x · Cited by 106 · cited 1× · see citing works
“In addition, premature infants may also experience severe arrhythmia caused by neonatal heart failure, and multiple organ dysfunction syndrome caused by neonatal asphyxia [8].”
BackgroundOsypka, M. J., & Bernstein, D. P. (1999) · AACN Clinical Issues Advanced Practice in Acute & Critical Care · doi:10.1097/00044067-199908000-00008 · Cited by 99 · cited 1× · see citing works
“Bernstein and Osypka [18] developed and described the technical background of EC, a new model for interpreting chest bioimpedance.”
BackgroundSanders, M. L., Servaas, S., & Slagt, C. (2019) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-019-00330-y · Cited by 99 · cited 1× · see citing works
“[31] have found through meta-analysis that ECG cannot replace thermodilution and TTE to measure absolute CO.”
BackgroundRelationship between blood pressure and blood flow in newborn preterm infants
Groves, A. M., Kuschel, C. A., Knight, D. B., & Skinner, J. R. (2007) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/adc.2006.109520 · Cited by 86 · see citing works
Suehiro, K., Joosten, A., Murphy, L. S.-L., Desebbe, O., Alexander, B. S., Kim, S.-H., & Cannesson, M. P. (2015) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-015-9757-9 · Cited by 72 · cited 1× · see citing works
“[32] conducted a series of prospective observational meta-analysis of more than 300 premature infants and more than 100 full-term infants, and they found that ECG measurement had a minimal deviation (–0.03 L min − 1 and a smallest percentage error (23.6%).”
BackgroundInfluentialBlohm, M. E. G., Obrecht, D., Hartwich, J., Mueller, G. C., Kersten, J. F., Weil, J., & Singer, D. (2014) · Critical Care · doi:10.1186/s13054-014-0603-0 · Cited by 63 · cited 1× · see citing works
“[24] showed that EC is comparable to the aortic flow-based TTE method for pediatric patients.”
ResultBohanon, F. J., Mrazek, A. A., Shabana, M. T., Mims, S., Radhakrishnan, G. L., Kramer, G. C., & Radhakrishnan, R. S. (2015) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2015.06.002 · Cited by 62 · see citing works
Boët, A., Jourdain, G., Demontoux, S., & Luca, D. D. (2016) · Journal of Perinatology · doi:10.1038/jp.2016.65 · Cited by 62 · cited 1× · see citing works
“[25,26] showed that EC method is feasible, reproducible, fast, and it is a useful tool for continuous monitoring, and hemodynamic evaluation of neonates.”
MethodElectrical velocimetry as a tool for measuring cardiac output in small infants after heart surgery
Grollmuss, O., Demontoux, S., Capderou, A., Serraf, A. E., & Belli, E. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2530-3 · Cited by 61 · cited 1× · see citing works
“[28] have found that EC and Doppler TTE have good consistency in estimating SV, and they are interchangeable.”
BackgroundSong, R., Rich, W. D., Kim, J. H., Finer, N., & Katheria, A. C. (2014) · American Journal of Perinatology · doi:10.1055/s-0034-1371707 · Cited by 58 · cited 1× · see citing works
“[23] evaluate the practicability of EC monitoring by comparing the results of CO and system blood flow, measured by EC and echocardiography (ECHO).”
MethodHsu, K.-H., Wu, T.-W., Wang, Y., Lim, W.-H., Lee, C.-C., & Lien, R.-I. (2016) · Journal of Perinatology · doi:10.1038/jp.2016.2 · Cited by 57 · cited 1× · see citing works
“[33] reported that a total of 280 neonates are studied and the results indicate that CO is positively correlated with gestational age, body weight and body surface area (r = 0.681, 0.822, 0.830; all p 0.001).”
BackgroundInfluentialNon-Invasive Cardiac Output Measurement in Low and Very Low Birth Weight: A Method Comparison
Grollmuss, O., & Gonzalez, P. (2014) · Frontiers in Pediatrics · doi:10.3389/fped.2014.00016 · Cited by 52 · cited 1× · see citing works
“[22] compared SV and HR of 228 premature infants with transthoracic echocardiography (TTE) (134 LBW, 94 VLBW) and EC (134 LBW, 94 VLBW) by bland-Altman diagram.”
MethodWu, T.-W., Tamrazi, B., Soleymani, S., Seri, I., & Noori, S. (2018) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2018.01.067 · Cited by 49 · see citing works
Prone positioning decreases cardiac output and increases systemic vascular resistance in neonates
Ma, M., Noori, S., Maarek, J.-M. I., Holschneider, D. P., Rubinstein, E. H., & Seri, I. (2015) · Journal of Perinatology · doi:10.1038/jp.2014.230 · Cited by 46 · cited 2× · see citing works
“[45] found that neonatal EC detection in different positions resulted in reduced CO and stroke output in prone position compared with supine position.”
BackgroundPerfusion index and its dynamic changes in preterm neonates with patent ductus arteriosus
Vidal, M., Ferragu, F., Durand, S., Baleine, J. F., Novais, A. R. B., & Cambonie, G. (2012) · Acta Paediatrica · doi:10.1111/apa.12130 · Cited by 42 · cited 1× · see citing works
“Besides, perfusion index (PI) and plethysmograph variability index (PVI) are also applied for monitoring early postnatal peripheral circulatory changes, with the advantages of convenience and noninvasiveness [10].”
MethodTorigoe, T., Sato, S., Nagayama, Y., Sato, T., & Yamazaki, H. (2015) · Journal of Perinatology · doi:10.1038/jp.2014.245 · Cited by 41 · cited 2× · see citing works
“The hemodynamic monitoring indexes of premature infants will be affected during high-frequency oscil-4 lation and PDA occurrence [21].”
BackgroundMethodHaemodynamic Transition after Birth: A New Tool for Non-Invasive Cardiac Output Monitoring
Freidl, T., Baik‐Schneditz, N., Pichler, G., Schwaberger, B., Zingerle, B., Avian, A., & Urlesberger, B. (2016) · Neonatology · doi:10.1159/000446468 · Cited by 41 · cited 1× · see citing works
“[20] have also used EC in the delivery room to monitor the first 15 minutes of the life of full-term infants.”
MethodCardiovascular Effects of Caffeine Therapy in Preterm Infants
Walther, F. J. (1990) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/archpedi.1990.02150340110035 · Cited by 40 · cited 1× · see citing works
“[52] found that left ventricular output and stroke output of preterm infants significantly increased from day 1 to day 7 after caffeine treatment.”
BackgroundHsu, K., Wu, T.-W., Wu, I.-H., Lai, M., Hsu, S.-Y., Huang, H.-W., Mok, T., & Lien, R. (2017) · Neonatology · doi:10.1159/000475774 · Cited by 35 · cited 1× · see citing works
“[48] report that PDA may affect EC measurement of CO in 79 premature infants with pulmonary PDA by comparing EC measurement with transthoracic echocardiography.”
MethodKatheria, A. C., Wozniak, M., Harari, D., Arnell, K., Petruzzelli, D. L., & Finer, N. N. (2015) · Maternal Health Neonatology and Perinatology · doi:10.1186/s40748-015-0016-3 · Cited by 31 · see citing works
Bowel Perforation in Premature Infants with Necrotizing Enterocolitis: Risk Factors and Outcomes
Yu, L., Tian, J., Zhao, X., Cheng, P., Chen, X., Yu, Y., Ding, X., Zhu, X., & Xiao, Z. (2016) · Gastroenterology Research and Practice · doi:10.1155/2016/6134187 · Cited by 28 · see citing works
Reinstadler, S. J., Feistritzer, H., Reindl, M., Klug, G., Mayr, A., Mair, J. M., Jaschke, W. R., & Metzler, B. (2016) · Open Heart · doi:10.1136/openhrt-2016-000485 · Cited by 28 · cited 1× · see citing works
“However, it is difficult to be promoted in wards because of continuous detection and expensive equipment [16].”
BackgroundThoracic fluid content by electric bioimpedance correlates with respiratory distress in newborns
Paviotti, G., Cunto, A. D., Moressa, V., Bettiol, C. S., & Demarini, S. (2017) · Journal of Perinatology · doi:10.1038/jp.2017.100 · Cited by 27 · cited 1× · see citing works
“[40] include 96 neonates with gestational age of 37.9 ± 2.6 weeks in the study.”
MethodInfluentialWu, T.-W., Lien, R., Seri, I., & Noori, S. (2017) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/archdischild-2016-311769 · Cited by 24 · cited 2× · see citing works
“[46] used EC (Electrocardiogram) and ECHO (Echocardiography) techniques to confirm that in healthy full-term infants, the decrease in cardiac output (CO) in the prone position is due to a reduction in stroke volume (SV) rather than heart rate (HR) decrease.”
BackgroundMethodEriksen, V. R., Trautner, S., Hahn, G. H., & Greisen, G. O. (2019) · PLoS ONE · doi:10.1371/journal.pone.0213537 · Cited by 22 · cited 1× · see citing works
“[44] have found that normal neonatal CO is stable within 0.5~6 hours after birth, and infants with perinatal asphyxia have lower CO before and during treat-ment.”
BackgroundInfluentialFarki, A., Kazemzadeh, R. B., & Noughabi, E. A. (2022) · Journal of Healthcare Engineering · doi:10.1155/2022/3549238 · Cited by 22 · cited 1× · see citing works
“The first category is the invasive CO monitoring techniques, including traditional hot dilution method, pulmonary artery floating catheter and direct Fick law [12].”
MethodShah, B. A., Fabres, J. G., Leone, T. A., Schmölzer, G. M., & Szyld, E. G. (2022) · Resuscitation Plus · doi:10.1016/j.resplu.2022.100320 · Cited by 22 · cited 1× · see citing works
“…present with conditions such as neonatal respiratory distress syndrome, absence of secondary pulmonary artery catheter, bronchopulmonary hypoplasia, congenital heart disease, neonatal meconium inhaled syndrome, neonatal infectious diseases, neonatal low blood volume shock, and septic shock [6,7].”
BackgroundLiu, S.-H., Wang, J.-J., Su, C.-H., & Cheng, D. (2018) · Sensors · doi:10.3390/s18093036 · Cited by 17 · cited 1× · see citing works
“A floating catheter is inserted into the subclavian vein, and CO and other hemodynamic indicators are calculated by tracing the area under the time-temperature curve [14].”
MethodBoët, A., Jourdain, G., Demontoux, S., Hascoët, S., Tissières, P., Rücker‐Martin, C., & Luca, D. D. (2017) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000001298 · Cited by 16 · cited 1× · see citing works
“[25,26] showed that EC method is feasible, reproducible, fast, and it is a useful tool for continuous monitoring, and hemodynamic evaluation of neonates.”
MethodDmytrіiev, D., Nazarchuk, O. A., Melnychenko, M., & Levchenko, B. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.935331 · Cited by 15 · cited 1× · see citing works
“…techniques, including the common pulse indicator continuous cardiac output (PiCCO) thermodilution technology, cardiovascular nuclear magnetic resonance imaging (MRI) technology, repeated partial respiration method, ultrasound cardiac output monitor (USCOM), and impedance cardiography [13].”
Methodde la Blanca, A. R. S., Luna, M. S., González‐Pacheco, N., Arriaga-Redondo, M., & Patiño, N. N. (2017) · European Journal of Pediatrics · doi:10.1007/s00431-017-3063-0 · Cited by 14 · cited 1× · see citing works
“[43] used EC to detect hemodynamic changes in neonates undergoing surgical ligation or drug closure of PDA, and found that CI, stroke volume index (SVI), and ICON decreased in children with closed ductus arteriosus.”
MethodPaviotti, G., Todero, S., & Demarini, S. (2017) · Journal of Perinatology · doi:10.1038/jp.2016.251 · Cited by 11 · cited 1× · see citing works
“[47] used the EC technique to compare left and supine positions, indicating that SV and CO were reduced.”
MethodEarly prediction of a significant patent ductus arteriosus in infants <32 weeks gestational age
Katheria, V., Poeltler, D. M., Brown, M. K., Hassen, K. O., Patel, D., Rich, W. D., Finer, N. N., & Katheria, A. C. (2018) · Journal of Neonatal-Perinatal Medicine · doi:10.3233/npm-1771 · Cited by 10 · cited 1× · see citing works
“[42] show that an increase in LV output and a decrease in average blood pressure, indicating the necessary management of clinically significant PDA.”
BackgroundGatelli, I. F., Vitelli, O., Fossati, M., Rienzo, F. D., Chiesa, G. B., & Martinelli, S. (2021) · American Journal of Perinatology · doi:10.1055/s-0041-1726123 · Cited by 9 · cited 1× · see citing works
“NICU real-time dynamic monitoring of neonatal hemodynamic changes is helpful for the early detection of unstable hemodynamics, and for timely adjusted strategy of treatments, thus reducing the viscera ischemia hypoxia and tissue damage [9].”
MethodA Device for the Quantification of Oxygen Consumption and Caloric Expenditure in the Neonatal Range
Nachman, E., Clemensen, P., Santos, K., Cole, A. R., Polizzotti, B. D., Hofmann, G., Leeman, K. T., van den Bosch, S. J., & Kheir, J. N. (2018) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000003308 · Cited by 8 · cited 1× · see citing works
“[15] have performed studies combined with the principle proposed by Fick, and demonstrated that Fick is accurate enough to serve as a basis for clinical decision-making.”
MethodBeccaria, P. F., Turi, S., Cristofolini, M., Colombo, S., Leggieri, C., Vinciguerra, F., & Zangrillo, A. (2010) · Europe PMC (PubMed Central) · Cited by 7 · see citing works
Yeniocak, S. (2019) · Medicina · doi:10.3390/medicina55120752 · Cited by 7 · cited 1× · see citing works
“During circulatory disturbances, blood flow shifts from nonvital organs and tissues (skin, subcutaneous tissue, muscles, gastrointestinal tract) to vital organs (heart, brain, kidneys) [ 11].”
BackgroundYuan, W., Zeng, L., Cai, B., Liu, X., Wang, S., Zhao, L.-X., Huang, Y., Wang, Q.-L., & Liu, H. (2018) · PubMed Central · doi:10.7499/j.issn.1008-8830.2018.01.004 · Cited by 5 · see citing works
Flagged first, then by citations
Research works printed but not linked: 8
- Ren XR, Tan YL, Jiang KF, Li J, Hu YH, Xiong XY, et al. Clini- cal application of electronic heart measurement in postoperative monitoring of children with congenital heart disease. Chongqing Medicine. 2021; 50: 3828-3832. (In Chinese)
- Huang Y, Li Y, Leng ZW, Yang XL. Objective guided fluid ther- apy for laparoscopic pancreatoduodenectomy based on Electrial Cardiometry TM . Chongqing Medical Science. 2018; 47: 2749- 2752. (In Chinese)
- Chen BL, Dai JW. Application of noninvasive hemodynamic monitoring in early resuscitation of septic shock. Chinese Jour- nal of Practical Medicine. 2018; 45: 56-58. (In Chinese)
- Yuan YH, Zhang AM, He XH, Xu J, Huang FR, Liu LP, et al. Clinical application of noninvasive heart index in the evaluation of neonatal congenital heart disease with heart failure. Journal of Clinical Pediatrics. 2017; 35: 747. (In Chinese)
- Zhang DC, Huang W, Yang B, Deng LY. Clinical observation of early cardiac function in patients with sepsis by electronic cardiometry and noninvasive cardiac output meter. Chongqing Medical Science. 2018; 47: 2364-2366. (In Chinese)
- Liu G, Li ZG, Wu HW, Wang W. Application of electronic heart measurement in the treatment of neonatal meconium aspiration syndrome. Family Medicine. 2018; 000(012): 5. (In Chinese)
- Ma J, Qin YP, Yang Q. Analysis of the factors affecting the prog- nosis of neonatal hypoxic-ischemic encephalopathy treated with mild hypothermia. Chinese Practical Medical Journal. 2021; 48: 4. (In Chinese)
- Eriksen VR, Trautner S, Hahn GH, Greisen G. Lactate acidosis and cardiac output during initial therapeutic cooling in asphyxi- ated newborn infants. PLoS One. 2019; 14: e0213537.
Cited by
Sorted by citations
Fatoni, A., Anggraeni, M. D., & Rahmawati, E. (2025) · Analytica—A Journal of Analytical Chemistry and Chemical Analysis · doi:10.3390/analytica6010006 · Cited by 4 · see citing works
Nedelcu, C., Ionescu, N. S., Bizubac, A. M., Filip, C., & Cirstoveanu, C. (2025) · Life · doi:10.3390/life15101621 · Cited by 2 · see citing works
“Moreover, EC has shown strong agreement with transthoracic echocardiography regarding stroke volume, stroke volume variation (SVV), and the inferior vena cava distensibility index (dIVC) [71].”
- Authors
- Li, F., & Dong, W.
- Affiliations
- Affiliated Hospital of Southwest Medical University (CN)
- Corresponding author
- Li, Fengying
- Dong, Wenbin
- Venue
- Clinical and Experimental Obstetrics & Gynecology
- Publisher
- IMR Press
- Published
- 2023-10-12
- Volume
- 50
- Issue
- 10
- ISSN
- 0390-6663 (ISSN-L)
- 2709-0094
- OpenAlex
- W4387609935
- Cited by
- 2
- References
- 44
- Citations by year
- 2025: 2
- FWCI
- 0.54
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Clinical and Experimental Obstetrics & Gynecology (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
- Keywords
- noninvasive hemodynamic monitoring, neonates, impedance cardiography, cardiac output monitoring, neonatal intensive care, invasive hemodynamic monitoring, critically ill neonates
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review