The blood serum concentration of cystatin C (γ-trace) as a measure of the glomerular filtration rate
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
The blood serum concentrations of creatinine and the low molecular weight proteins cystatin C, beta 2-microglobulin and retinol-binding protein were measured in 106 patients whose glomerular filtration rates were assessed by Cr-ethylenediaminetetraacetate (EDTA)-clearance determinations. The reciprocals of the serum concentrations of creatinine, cystatin C and beta 2-microglobulin were closely correlated to the Cr-EDTA-clearance (r = 0.73, 0.75 and 0.70, respectively) in contrast to the corresponding values for retinol-binding protein (r = 0.39). The calculated values of the glomerular elimination rate for creatinine and cystatin C were normally distributed in contrast to those for beta 2-microglobulin. The calculated glomerular elimination rate of cystatin C was not correlated to age, sex, type of disorder or disease activity. The results demonstrate that the serum level of cystatin C is a better measure of the glomerular filtration rate than the serum level of beta 2-microglobulin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laurell, C.-B. (1972) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365517209102748 · Cited by 1,687
A Simple Method for the Determination of Glomerular Filtration Rate
Bröchner-Mortensen, J. (1972) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365517209084290 · Cited by 886
Determination of serum creatinine by a direct colorimetric method
Heinegård, D., & Tiderström, G. (1973) · Clinica Chimica Acta · doi:10.1016/0009-8981(73)90466-x · Cited by 720
Vitamin A and retinoids in health and disease
Epstein, F. H., & Goodman, D. S. (1984) · New England Journal of Medicine · doi:10.1056/nejm198404193101605 · Cited by 553
Peterson, P. A., Evrin, P.-E., & Berggård, I. (1969) · Journal of Clinical Investigation · doi:10.1172/jci106083 · Cited by 540
Smith, F. R., & Goodman, D. S. (1971) · Journal of Clinical Investigation · doi:10.1172/jci106741 · Cited by 447
Hotelling, H. (1940) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177731867 · Cited by 437
Human gamma-trace, a basic microprotein: amino acid sequence and presence in the adenohypophysis.
Grubb, A., & Löfberg, H. (1982) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.79.9.3024 · Cited by 327
Self-citationThe place of human γ-trace (cystatin C) amongst the cysteine proteinase inhibitors
Barrett, A. J., Davies, M. E., & Grubb, A. (1984) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(84)91302-0 · Cited by 294
Self-citationThe Serum Levels and Urinary Excretion of β2-Microglobulin in Apparently Healthy Subjects
Evrin, P.-E., & Wibell, L. (1972) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365517209081057 · Cited by 254
Cited by
Serum cystatin C is superior to serum creatinine as a marker of kidney function: A meta-analysis
Dharnidharka, V. R., Kwon, C., & Stevens, G. (2002) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2002.34487 · Cited by 1,663
Cystatin C as a marker of GFR—history, indications, and future research
Filler, G., Bökenkamp, A., Hofmann, W., Le Bricon, T., Martínez-Brú, C., & Grubb, A. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.09.025 · Cited by 734
Self-citationNewman, D. J., Thakkar, H., Edwards, R. G., Wilkie, M., White, T., Grubb, A. O., & Price, C. P. (1995) · Kidney International · doi:10.1038/ki.1995.40 · Cited by 650
Self-citationColl, E., Botey, A., Alvarez, L., Poch, E., Quintó, L., Saurina, A., Vera, M., Piera, C., & Darnell, A. (2000) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2000.8237 · Cited by 642
Hoek, F. J. (2003) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfg349 · Cited by 564
Kyhse-Andersen, J., Schmidt, C., Nordin, G., Andersson, B., Nilsson-Ehle, P., Lindström, V, & Grubb, A. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.10.1921 · Cited by 511
Self-citationGrubb, A., Nyman, U., Björk, J., Lindström, V., Rippe, B., Sterner, G., & Christensson, A. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.051557 · Cited by 459
Self-citationRenal handling of radiolabelled human cystatin C in the rat
Tenstad, O., Roald, A. B., Grubb, A., & Aukland, K. (1996) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365519609088795 · Cited by 456
Self-citationCystatin C-Properties and use as diagnostic marker
(2001) · Advances in Clinical Chemistry · doi:10.1016/s0065-2423(01)35015-1 · Cited by 418
Impact of thyroid dysfunction on serum cystatin C
Fricker, M., Wiesli, P., Brändle, M., Schwegler, B., & Schmid, C. (2003) · Kidney International · doi:10.1046/j.1523-1755.2003.00925.x · Cited by 369
Serum Cystatin C as an Endogenous Marker of the Renal Function – a Review
Randers, E., & Erlandsen, E. J. (1999) · cclm · doi:10.1515/cclm.1999.064 · Cited by 334
Grubb, A., Horio, M., Hansson, L.-O., Björk, J., Nyman, U., Flodin, M., Larsson, A., Bökenkamp, A., Yasuda, Y., Blufpand, H., et al. (2014) · Clinical Chemistry · doi:10.1373/clinchem.2013.220707 · Cited by 324
Self-citationFinney, H., Newman, D. J., Gruber, W., Merle, P., & Price, C. P. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.6.1016 · Cited by 318
Biochemistry and Clinical Role of Human Cystatin C
Mussap, M., & Plebani, M. (2004) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408360490504934 · Cited by 313
GRUBB, A., SIMONSEN, O., STURFELT, G., TRUEDSSON, L., & THYSELL, H. (1985) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1985.tb08880.x · Cited by 303
Self-citationMussap, M., Vestra, M. D., Fioretto, P., Saller, A., Varagnolo, M., Nosadini, R., & Plebani, M. (2002) · Kidney International · doi:10.1046/j.1523-1755.2002.00253.x · Cited by 292
Adult Reference Ranges for Serum Cystatin C, Creatinine and Predicted Creatinine Clearance
Finney, H., Newman, D. J., & Price, C. P. (2000) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456320003700101 · Cited by 287
Biomarkers of Drug-Induced Kidney Toxicity
Griffin, B. R., Faubel, S., & Edelstein, C. L. (2019) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000000589 · Cited by 285
Biomarkers of Acute Kidney Injury
Edelstein, C. L. (2008) · Advances in Chronic Kidney Disease · doi:10.1053/j.ackd.2008.04.003 · Cited by 272
Biological variation of cystatin C: implications for the assessment of glomerular filtration rate
Keevil, B. G., Kilpatrick, E. S., Nichols, S. P., & Maylor, P. W. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.7.1535 · Cited by 232
“This is also reflected in the high IoI for the analyte (1.64), which, of relevance, is comparable with the findings of a previous study where creatinine clearance was used to assess GFR (9).”
BackgroundInfluentialTidman, M., Sjostrom, P., & Jones, I. (2007) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfm661 · Cited by 193
“Cystatin C, a small, non-glycosylated 13 kDa basic protein, has been proposed as an alternative filtration marker to creatinine [6,7].”
BackgroundSerum cystatin C, a potent inhibitor of cysteine proteinases, is elevated in asthmatic patients
Cimerman, N., Brguljan, P. M., Krašovec, M., Šuškovič, S., & Kos, J. (2000) · Clinica Chimica Acta · doi:10.1016/s0009-8981(00)00298-9 · Cited by 181
Murata, K., Baumann, N. A., Saenger, A. K., Larson, T. S., Rule, A. D., & Lieske, J. C. (2011) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.02300311 · Cited by 178
“In addition, given the problems with using serum creatinine to estimate GFR, other endogenous markers, such as cystatin C (23) or beta trace protein (24,25), that are less influenced by muscle mass may be helpful as confirmatory tests to identify patients with true reductions in GFR.”
Background
Metadata
- Authors
- Simonsen, O., Grubb, A., & Thysell, H.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1985-01
- Volume
- 45
- Issue
- 2
- Pages
- 97-101
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W1966266726
- Cited by
- 337
- References
- 17
- FWCI
- 1.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.