Stability of FDG-PET Radiomics features: An integrated analysis of test-retest and inter-observer variability
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
PURPOSE: Besides basic measurements as maximum standardized uptake value (SUV)max or SUVmean derived from 18F-FDG positron emission tomography (PET) scans, more advanced quantitative imaging features (i.e. "Radiomics" features) are increasingly investigated for treatment monitoring, outcome prediction, or as potential biomarkers. With these prospected applications of Radiomics features, it is a requisite that they provide robust and reliable measurements. The aim of our study was therefore to perform an integrated stability analysis of a large number of PET-derived features in non-small cell lung carcinoma (NSCLC), based on both a test-retest and an inter-observer setup. METHODS: Eleven NSCLC patients were included in the test-retest cohort. Patients underwent repeated PET imaging within a one day interval, before any treatment was delivered. Lesions were delineated by applying a threshold of 50% of the maximum uptake value within the tumor. Twenty-three NSCLC patients were included in the inter-observer cohort. Patients underwent a diagnostic whole body PET-computed tomography (CT). Lesions were manually delineated based on fused PET-CT, using a standardized clinical delineation protocol. Delineation was performed independently by five observers, blinded to each other. Fifteen first order statistics, 39 descriptors of intensity volume histograms, eight geometric features and 44 textural features were extracted. For every feature, test-retest and inter-observer stability was assessed with the intra-class correlation coefficient (ICC) and the coefficient of variability, normalized to mean and range. Similarity between test-retest and inter-observer stability rankings of features was assessed with Spearman's rank correlation coefficient. RESULTS: Results showed that the majority of assessed features had both a high test-retest (71%) and inter-observer (91%) stability in terms of their ICC. Overall, features more stable in repeated PET imaging were also found to be more robust against inter-observer variability. CONCLUSION: Results suggest that further research of quantitative imaging features is warranted with respect to more advanced applications of PET imaging as being used for treatment monitoring, outcome prediction or imaging biomarkers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886
Radiomics: extracting more information from medical images using advanced feature analysis
Lambin, P., Rios-Velazquez, E., Leijenaar, R., Carvalho, S., van Stiphout, R. G. P. M., Granton, P., Zegers, C. M. L., Gillies, R., Boellard, R., Dekker, A., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.11.036 · Cited by 6,084
Self-citationRadiomics: the process and the challenges
Kumar, V., Gu, Y., Basu, S., Berglund, A., Eschrich, S. A., Schabath, M. B., Forster, K., Aerts, H. J. W. L., Dekker, A., Fenstermacher, D., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.010 · Cited by 2,258
Self-citationTexture analysis using gray level run lengths
Galloway, M. M. (1975) · Computer Graphics and Image Processing · doi:10.1016/s0146-664x(75)80008-6 · Cited by 2,141
Agreement Between Methods of Measurement with Multiple Observations Per Individual
Bland, J. M., & Altman, D. G. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400701329422 · Cited by 2,065
CERR: A computational environment for radiotherapy research
Deasy, J. O., Blanco, A. I., & Clark, V. H. (2003) · Medical Physics · doi:10.1118/1.1568978 · Cited by 872
Tixier, F., Le Rest, C. C., Hatt, M., Albarghach, N., Pradier, O., Metges, J.-P., Corcos, L., & Visvikis, D. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.082404 · Cited by 696
Understanding the standardized uptake value, its methods, and implications for usage.
Thie, J. A. (2004) · PubMed · Cited by 546
Exploring feature-based approaches in PET images for predicting cancer treatment outcomes
El Naqa, I., Grigsby, P. W., Apte, A., Kidd, E., Donnelly, E., Khullar, D., Chaudhari, S., Yang, D., Schmitt, M., Laforest, R., et al. (2009) · Pattern Recognition · doi:10.1016/j.patcog.2008.08.011 · Cited by 480
Cited by
Radiomics in medical imaging—“how-to” guide and critical reflection
van Timmeren, J. E., Cester, D., Tanadini-Lang, S., Alkadhi, H., & Baessler, B. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00887-2 · Cited by 1,316
Applications and limitations of radiomics
Yip, S. S. F., & Aerts, H. J. W. L. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/13/r150 · Cited by 1,210
Self-citationMachine Learning methods for Quantitative Radiomic Biomarkers
Parmar, C., Grossmann, P., Bussink, J., Lambin, P., & Aerts, H. J. W. L. (2015) · Scientific Reports · doi:10.1038/srep13087 · Cited by 1,019
Self-citationLiu, Z., Wang, S., Dong, D., Wei, J., Fang, C., Zhou, X., Sun, K., Li, L., Li, B., Wang, M., et al. (2019) · Theranostics · doi:10.7150/thno.30309 · Cited by 967
Repeatability and Reproducibility of Radiomic Features: A Systematic Review
Traverso, A., Wee, L., Dekker, A., & Gillies, R. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.05.053 · Cited by 903
Self-citationCT-based radiomic signature predicts distant metastasis in lung adenocarcinoma
Coroller, T. P., Grossmann, P., Hou, Y., Rios Velazquez, E., Leijenaar, R. T. H., Hermann, G., Lambin, P., Haibe-Kains, B., Mak, R. H., & Aerts, H. J. W. L. (2015) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2015.02.015 · Cited by 695
“The advantage of the radiomic shape features is that they can be automatically acquired, reproducible [10–12], and take into account the whole tumor volume, whereas clinically assessed tumor diameters aremanually drawn on a CT slice and are therefore limited to one dimension of the tumor.”
Self-citationMeasuring Computed Tomography Scanner Variability of Radiomics Features
Mackin, D., Fave, X., Zhang, L., Fried, D., Yang, J., Taylor, B., Rodriguez-Rivera, E., Dodge, C., Jones, A. K., & Court, L. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000180 · Cited by 651
Berenguer, R., Pastor-Juan, M. D. R., Canales-Vázquez, J., Castro-García, M., Villas, M. V., Mansilla Legorburo, F., & Sabater, S. (2018) · Radiology · doi:10.1148/radiol.2018172361 · Cited by 622
Robust Radiomics Feature Quantification Using Semiautomatic Volumetric Segmentation
Parmar, C., Rios Velazquez, E., Leijenaar, R., Jermoumi, M., Carvalho, S., Mak, R. H., Mitra, S., Shankar, B. U., Kikinis, R., Haibe-Kains, B., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0102107 · Cited by 611
Self-citationMachine and deep learning methods for radiomics
Avanzo, M., Wei, L., Stancanello, J., Vallières, M., Rao, A., Morin, O., Mattonen, S. A., & El Naqa, I. (2020) · Medical Physics · doi:10.1002/mp.13678 · Cited by 605
Ethical and Bias Considerations in Artificial Intelligence/Machine Learning
Hanna, M. G., Pantanowitz, L., Jackson, B., Palmer, O., Visweswaran, S., Pantanowitz, J., Deebajah, M., & Rashidi, H. H. (2025) · Modern Pathology · doi:10.1016/j.modpat.2024.100686 · Cited by 535
Reproducibility of radiomics for deciphering tumor phenotype with imaging
Zhao, B., Tan, Y., Tsai, W.-Y., Qi, J., Xie, C., Lu, L., & Schwartz, L. H. (2016) · Scientific Reports · doi:10.1038/srep23428 · Cited by 509
Beyond imaging: The promise of radiomics
Avanzo, M., Stancanello, J., & El Naqa, I. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.05.071 · Cited by 483
Characterization of PET/CT images using texture analysis: the past, the present… any future?
Hatt, M., Tixier, F., Pierce, L., Kinahan, P. E., Le Rest, C. C., & Visvikis, D. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3427-0 · Cited by 475
Leijenaar, R. T. H., Nalbantov, G., Carvalho, S., van Elmpt, W. J. C., Troost, E. G. C., Boellaard, R., Aerts, H. J. W. L., Gillies, R. J., & Lambin, P. (2015) · Scientific Reports · doi:10.1038/srep11075 · Cited by 426
Self-citationZhou, M., Scott, J., Chaudhury, B., Hall, L., Goldgof, D., Yeom, K. W., Iv, M., Ou, Y., Kalpathy-Cramer, J., Napel, S., et al. (2018) · American Journal of Neuroradiology · doi:10.3174/ajnr.a5391 · Cited by 415
Self-citationRadiomic Machine-Learning Classifiers for Prognostic Biomarkers of Head and Neck Cancer
Parmar, C., Grossmann, P., Rietveld, D., Rietbergen, M. M., Lambin, P., & Aerts, H. J. W. L. (2015) · Frontiers in Oncology · doi:10.3389/fonc.2015.00272 · Cited by 407
Self-citationPark, J. E., Park, S. Y., Kim, H. J., & Kim, H. S. (2019) · Korean Journal of Radiology · doi:10.3348/kjr.2018.0070 · Cited by 388
Peng, S., Liu, Y., Lv, W., Liu, L., Zhou, Q., Yang, H., Ren, J., Liu, G., Wang, X., Zhang, X., et al. (2021) · The Lancet Digital Health · doi:10.1016/s2589-7500(21)00041-8 · Cited by 377
Radiomics: from qualitative to quantitative imaging
Rogers, W., Thulasi Seetha, S., Refaee, T. A. G., Lieverse, R. I. Y., Granzier, R. W. Y., Ibrahim, A., Keek, S. A., Sanduleanu, S., Primakov, S. P., Beuque, M. P. L., et al. (2020) · The British Journal of Radiology · doi:10.1259/bjr.20190948 · Cited by 372
Self-citationRadiomics: a new application from established techniques
Parekh, V., & Jacobs, M. A. (2016) · Expert Review of Precision Medicine and Drug Development · doi:10.1080/23808993.2016.1164013 · Cited by 369
Defining the biological basis of radiomic phenotypes in lung cancer
Grossmann, P., Stringfield, O., El-Hachem, N., Bui, M. M., Rios Velazquez, E., Parmar, C., Leijenaar, R. T., Haibe-Kains, B., Lambin, P., Gillies, R. J., et al. (2017) · eLife · doi:10.7554/elife.23421 · Cited by 365
Self-citationLarue, R. T. H. M., Defraene, G., De Ruysscher, D., Lambin, P., & van Elmpt, W. (2017) · The British Journal of Radiology · doi:10.1259/bjr.20160665 · Cited by 363
Self-citationFalse Discovery Rates in PET and CT Studies with Texture Features: A Systematic Review
Chalkidou, A., O’Doherty, M. J., & Marsden, P. K. (2015) · PLOS ONE · doi:10.1371/journal.pone.0124165 · Cited by 344
Radiomic phenotype features predict pathological response in non-small cell lung cancer
Coroller, T. P., Agrawal, V., Narayan, V., Hou, Y., Grossmann, P., Lee, S. W., Mak, R. H., & Aerts, H. J. W. L. (2016) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2016.04.004 · Cited by 327
Self-citationRadiogenomics: bridging imaging and genomics
Bodalal, Z., Trebeschi, S., Nguyen-Kim, T. D. L., Schats, W., & Beets-Tan, R. (2019) · Abdominal Radiology · doi:10.1007/s00261-019-02028-w · Cited by 310
Zwanenburg, A. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04391-8 · Cited by 306
van Velden, F. H. P., Kramer, G. M., Frings, V., Nissen, I. A., Mulder, E. R., de Langen, A. J., Hoekstra, O. S., Smit, E. F., & Boellaard, R. (2016) · Molecular Imaging and Biology · doi:10.1007/s11307-016-0940-2 · Cited by 286
Self-citationPeerlings, J., Woodruff, H. C., Winfield, J. M., Ibrahim, A., Van Beers, B. E., Heerschap, A., Jackson, A., Wildberger, J. E., Mottaghy, F. M., DeSouza, N. M., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-41344-5 · Cited by 266
Self-citationIbrahim, A., Primakov, S., Beuque, M., Woodruff, H. C., Halilaj, I., Wu, G., Refaee, T., Granzier, R., Widaatalla, Y., Hustinx, R., et al. (2021) · Methods · doi:10.1016/j.ymeth.2020.05.022 · Cited by 265
Self-citationRadiomics and deep learning in lung cancer
Avanzo, M., Stancanello, J., Pirrone, G., & Sartor, G. (2020) · Strahlentherapie und Onkologie · doi:10.1007/s00066-020-01625-9 · Cited by 263
Larue, R. T. H. M., van Timmeren, J. E., de Jong, E. E. C., Feliciani, G., Leijenaar, R. T. H., Schreurs, W. M. J., Sosef, M. N., Raat, F. H. P. J., van der Zande, F. H. R., Das, M., et al. (2017) · Acta Oncologica · doi:10.1080/0284186x.2017.1351624 · Cited by 262
Self-citationHe, L., Huang, Y., Ma, Z., Liang, C., Liang, C., & Liu, Z. (2016) · Scientific Reports · doi:10.1038/srep34921 · Cited by 256
Liu, X., Li, Y., Qian, Z., Sun, Z., Xu, K., Wang, K., Liu, S., Fan, X., Li, S., Zhang, Z., et al. (2018) · NeuroImage: Clinical · doi:10.1016/j.nicl.2018.10.014 · Cited by 245
“Previous studies have already documented the robustness of extraction of radiomic features in terms of repeatability and reproducibility in test/re-test settings (Aerts et al., 2014; Balagurunathan et al., 2014; Fried et al., 2014; Grove et al., 2015; Leijenaar et al., 2013; Parmar et al., 2015).”
BackgroundAssessing robustness of radiomic features by image perturbation
Zwanenburg, A., Leger, S., Agolli, L., Pilz, K., Troost, E. G. C., Richter, C., & Löck, S. (2019) · Scientific Reports · doi:10.1038/s41598-018-36938-4 · Cited by 242
Repeatability of Multiparametric Prostate MRI Radiomics Features
Schwier, M., van Griethuysen, J., Vangel, M. G., Pieper, S., Peled, S., Tempany, C., Aerts, H. J. W. L., Kikinis, R., Fennessy, F. M., & Fedorov, A. (2019) · Scientific Reports · doi:10.1038/s41598-019-45766-z · Cited by 237
Self-citationLeijenaar, R. T. H., Carvalho, S., Hoebers, F. J. P., Aerts, H. J. W. L., van Elmpt, W. J. C., Huang, S. H., Chan, B., Waldron, J. N., O’sullivan, B., & Lambin, P. (2015) · Acta Oncologica · doi:10.3109/0284186x.2015.1061214 · Cited by 217
Self-citationCT-based radiomic analysis of stereotactic body radiation therapy patients with lung cancer
Huynh, E., Coroller, T. P., Narayan, V., Agrawal, V., Hou, Y., Romano, J., Franco, I., Mak, R. H., & Aerts, H. J. W. L. (2016) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2016.05.024 · Cited by 215
Self-citationShiri, I., Rahmim, A., Ghaffarian, P., Geramifar, P., Abdollahi, H., & Bitarafan-Rajabi, A. (2017) · European Radiology · doi:10.1007/s00330-017-4859-z · Cited by 204
Influence of inter-observer delineation variability on radiomics stability in different tumor sites
Pavic, M., Bogowicz, M., Würms, X., Glatz, S., Finazzi, T., Riesterer, O., Roesch, J., Rudofsky, L., Friess, M., Veit-Haibach, P., et al. (2018) · Acta Oncologica · doi:10.1080/0284186x.2018.1445283 · Cited by 203
Test–Retest Data for Radiomics Feature Stability Analysis: Generalizable or Study-Specific?
van Timmeren, J. E., Leijenaar, R. T. H., van Elmpt, W., Wang, J., Zhang, Z., Dekker, A., & Lambin, P. (2016) · Tomography · doi:10.18383/j.tom.2016.00208 · Cited by 191
“This can be solved, in part, by following a strict policy of feature reduction, for example, with test–retest and multiple delineation studies (8, 9), to select only those robust features that provide repeatable and reproducible measurements.”
BackgroundSelf-citationRadiomics feature reliability assessed by intraclass correlation coefficient: a systematic review
Xue, C., Yuan, J., Lo, G. G., Chang, A. T. Y., Poon, D. M. C., Wong, O. L., Zhou, Y., & Chu, W. C. W. (2021) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-21-86 · Cited by 177
“In the studies investigating both acquisition and segmentation, acquisition was consistently reported to have much larger impacts on feature variability (always smaller ICCs) than segmentation (35,39,42,44,48,56,126,132) for all modalities.”
BackgroundDesseroit, M.-C., Tixier, F., Weber, W. A., Siegel, B. A., Cheze Le Rest, C., Visvikis, D., & Hatt, M. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.180919 · Cited by 160
“Regarding shape and heterogeneity features, our results confirm prior findings in PET (8,14–17) .”
PET Radiomics in NSCLC: state of the art and a proposal for harmonization of methodology
Sollini, M., Cozzi, L., Antunovic, L., Chiti, A., & Kirienko, M. (2017) · Scientific Reports · doi:10.1038/s41598-017-00426-y · Cited by 158
Panth, K. M., Leijenaar, R. T. H., Carvalho, S., Lieuwes, N. G., Yaromina, A., Dubois, L., & Lambin, P. (2015) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2015.06.013 · Cited by 133
“A detailed description and mathematical definitions of the radiomics features assessed in this study are described elsewhere [9,15].”
MethodSelf-citationPermuth, J. B., Collaborative, T. F. P., Choi, J., Balarunathan, Y., Kim, J., Chen, D.-T., Chen, L., Orcutt, S., Doepker, M. P., Gage, K., et al. (2016) · Oncotarget · doi:10.18632/oncotarget.11768 · Cited by 127
Self-citationPolk, S. L., Choi, J. W., McGettigan, M. J., Rose, T., Ahmed, A., Kim, J., Jiang, K., Balagurunathan, Y., Qi, J., Farah, P. T., et al. (2020) · World Journal of Gastroenterology · doi:10.3748/wjg.v26.i24.3458 · Cited by 48
Lee, J. W., Park, S.-H., Ahn, H., Lee, S. M., & Jang, S. J. (2021) · Cancers · doi:10.3390/cancers13143563 · Cited by 18
“First-order entropy of PET/CT images measured via SUV-histogram analysis was found to be one of the textural features insensitive to PET image reconstruction methods and showed an excellent inter-rater agreement for the measurement [6,38,39].”
Method
Metadata
- Authors
- Leijenaar, R. T. H., Carvalho, S., Velazquez, E. R., van Elmpt, W. J. C., Parmar, C., Hoekstra, O. S., Hoekstra, C. J., Boellaard, R., Dekker, A. L. A. J., Gillies, R. J., Aerts, H. J. W. L., & Lambin, P.
- Venue
- Acta Oncologica
- Published
- 2013-09-09
- Volume
- 52
- Issue
- 7
- Pages
- 1391-1397
- ISSN
- 0284-186X (ISSN-L)
- 1651-226X
- OpenAlex
- W2089588713
- Cited by
- 427
- References
- 22
- FWCI
- 16.64
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.