Validating the Use of Wrist-Level Light Monitoring for In-Hospital Circadian Studies
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
This clinical methods comparison study describes the difference between light levels measured at the wrist (Actiwatch-L) and at the eye (Daysimeter) in a postoperative in-patient population. The mean difference between the two devices was less than 10 lux at light levels less than 5000 lux. Agreement between the devices was found to decrease as eye-level light exposure increased. Measurements at eye level of 5000 lux or more corresponded to a difference between the devices of greater than 100 lux. Agreement between the eye- and wrist-level light measurements also appears to be influenced by time of day. During the day, the measurement differences were on average 50 lux higher at eye level, whereas at night they were on average 50 lux lower. Although the wrist-level monitor was found to underestimate light exposure at higher light levels, it was well tolerated by participants in the clinical setting. In contrast, the eye-level monitor was cumbersome and uncomfortable for the patients to wear. This study provides light-exposure data on patients in real conditions in the clinical environment. The results show that wrist-level monitoring provides an adequate estimate of light exposure for in-hospital circadian studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Role of Actigraphy in the Study of Sleep and Circadian Rhythms
Ancoli-Israel, S., Cole, R., Alessi, C., Chambers, M., Moorcroft, W., & Pollak, C. P. (2003) · Sleep · doi:10.1093/sleep/26.3.342 · Cited by 2,751 · cited 2×
“Wrist-worn light monitoring devices are commonplace in clinical studies (Alessi et al., 2008; Ancoli-Israel et al., 2003; Berger et al., 2009; Bisgaard et al., 1999), but eye-level light monitors, which in theory provide a more accurate estimate of light entering the eye, are less common (Grundy et al.”
BackgroundThapan, K., Arendt, J., & Skene, D. J. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.t01-1-00261.x · Cited by 1,320 · cited 1×
“For subjects with dilated pupils, monochromatic blue-light (456 nm) exposure to as low as 10 lux for 45 min can induce melatonin suppression (Thapan et al., 2001).”
BackgroundZeitzer, J. M., Dijk, D., Kronauer, R. E., Brown, E. N., & Czeisler, C. A. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.00695.x · Cited by 1,175 · cited 3×
“In controlled laboratory conditions, a single broad spectrum 6.5-h pulse of 100 lux can phase shift the circadian clock half as much as a 9000 lux pulse (Zeitzer et al., 2000).”
BackgroundInfluentialRotating night shifts and risk of breast cancer in women participating in the nurses׳ health study
Schernhammer, E. S., Laden, F., Speizer, F. E., Willett, W. C., Hunter, D. J., Kawachi, I., & Colditz, G. A. (2001) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/93.20.1563 · Cited by 1,142
Morning sunlight reduces length of hospitalization in bipolar depression
Benedetti, F., Colombo, C., Barbini, B., Campori, E., & Smeraldi, E. (2001) · Journal of Affective Disorders · doi:10.1016/s0165-0327(00)00149-x · Cited by 341 · cited 1×
“Depressed in-patients housed in bright hospital rooms have been shown to have a shorter (up to 3.7 d) stay than those housed in dimly lit rooms (Beauchemin et al., 1996; Benedetti et al., 2001).”
BackgroundInfluentialChronotherapeutics (light and wake therapy) in affective disorders
WIRZ-JUSTICE, A., BENEDETTI, F., BERGER, M., LAM, R. W., MARTINY, K., TERMAN, M., & WU, J. C. (2005) · Psychological Medicine · doi:10.1017/s003329170500437x · Cited by 291
Links between the innate immune system and sleep
Majde, J. A., & Krueger, J. M. (2005) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2005.08.005 · Cited by 277
Grundy, A., Sanchez, M., Richardson, H., Tranmer, J., Borugian, M., Graham, C. H., & Aronson, K. J. (2009) · Chronobiology International · doi:10.3109/07420520903399987 · Cited by 95 · cited 1×
“…al., 2008; Ancoli-Israel et al., 2003; Berger et al., 2009; Bisgaard et al., 1999), but eye-level light monitors, which in theory provide a more accurate estimate of light entering the eye, are less common (Grundy et al., 2009; Higgins et al., 2010; Schernhammer et al., 2001; Savides et al., 1986).”
BackgroundArjona, A., & Sarkar, D. K. (2008) · Neurochemical Research · doi:10.1007/s11064-007-9501-z · Cited by 60
Cited by
The Current State of Optical Sensors in Medical Wearables
Vavrinsky, E., Esfahani, N. E., Hausner, M., Kuzma, A., Rezo, V., Donoval, M., & Kosnacova, H. (2022) · Biosensors · doi:10.3390/bios12040217 · Cited by 103
Wearable Devices for Environmental Monitoring in the Built Environment: A Systematic Review
Salamone, F., Masullo, M., & Sibilio, S. (2021) · Sensors · doi:10.3390/s21144727 · Cited by 89
“…sensor” OR “air quality” OR pollution) AND (environmental W/3 monitoring) AND NOT (“proton exchange mem-brane” OR “fuel cell”)) OR EID (2-s2 [64] Photopic illuminance in lux from 400 to 900 nm (Philips Actiwatch-L) and photopic illuminance in lux from 400 to 700 nm (Daysimeter) Indoor.”
BackgroundSpitschan, M., Smolders, K., Vandendriessche, B., Bent, B., Bakker, J. P., Rodriguez-Chavez, I. R., & Vetter, C. (2022) · DIGITAL HEALTH · doi:10.1177/20552076221144858 · Cited by 54
Dev, M. K., Black, A. A., Cuda, D., & Wood, J. M. (2022) · Translational Vision Science & Technology · doi:10.1167/tvst.11.3.21 · Cited by 10
Metadata
- Authors
- Jardim, A. C. N., Pawley, M. D. M., Cheeseman, J. F., Guesgen, M. J., Steele, C. T., & Warman, G. R.
- Venue
- Chronobiology International
- Publisher
- Informa UK Limited
- Published
- 2011-09-21
- Volume
- 28
- Issue
- 9
- Pages
- 834-840
- ISSN
- 0742-0528 (ISSN-L)
- 1525-6073
- OpenAlex
- W2022616422
- Cited by
- 35
- References
- 9
- FWCI
- 0.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validating the Use of Wrist-Level Light Monitoring for In-Hospital Circadian Studies. https://app.cochat.ai/papers/10.3109/07420528.2011.611603
- The paper
- Jardim, A. C. N., Pawley, M. D. M., Cheeseman, J. F., Guesgen, M. J., Steele, C. T., & Warman, G. R. (2011). Validating the Use of Wrist-Level Light Monitoring for In-Hospital Circadian Studies. Chronobiology International. https://doi.org/10.3109/07420528.2011.611603
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.