CoChat

Microtopography and Soft Tissue Response

Campbell, Craig E., Von Recum, Andreas F. · 1989 · Journal of Investigative Surgery
Cited by 134

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Implants placed in soft tissue evoke a foreign body reaction. Polymeric implants having smooth surfaces, such as silicone rubber implants, develop a nonadherent fibrogranulous tissue capsule which contracts over time and stiffens. Conventional porous implants, such as those made from textiles, usually have pores larger than 20 microns and they become infiltrated with inflammatory tissue. The in vivo cell reaction to polymeric surfaces having pores smaller than 10 microns has not been investigated systematically. In this study the histocompatibility of materials having mean pore diameters from 0.4 to 10 microns was assessed. A material available with several different defined pore sizes Versapor filter material) was tested in vivo to determine relation between pore size and qualitative tissue response. Silicone-coated samples were also tested to determine the dependence of the observed tissue response on the implant surface chemistry. Results showed nonadherent, contracting capsules around implants having pore diameters smaller than 0.5 microns. Implants with pores ranging from 1.4 to 1.9 microns evoked thin, tightly adherent fibrous capsules without inflammatory cells. Porosities of 3.3 microns and larger became infiltrated with inflammatory tissue. Results indicate that the observed tissue response is predominantly dependent on implant surface topography and that variation in implant material may have little effect. It is concluded that a defined surface topography of 1 to 2 microns appears to allow direct fibroblast attachment to the surface independent of its chemical or electrochemical nature. Attached fibroblasts then produce a minimal connective tissue response to the implant and prevent or diminish the presence of inflammatory cells at the implant/tissue interface.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/08941938909016503

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 134

Metadata

Authors
Campbell, C. E., & Von Recum, A. F.
Venue
Journal of Investigative Surgery
Published
1989-01
Volume
2
Issue
1
Pages
51-74
ISSN
  • 0894-1939 (ISSN-L)
  • 1521-0553
OpenAlex
W1972617359
Cited by
134
References
1
FWCI
4.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.