Abstract
Implants placed in soft tissue evoke a foreign body reaction. Polymeric implants having smooth surfaces, such as silicone rubber implants, develop a nonadherent fibrogranulous tissue capsule which contracts over time and stiffens. Conventional porous implants, such as those made from textiles, usually have pores larger than 20 microns and they become infiltrated with inflammatory tissue. The in vivo cell reaction to polymeric surfaces having pores smaller than 10 microns has not been investigated systematically. In this study the histocompatibility of materials having mean pore diameters from 0.4 to 10 microns was assessed. A material available with several different defined pore sizes Versapor filter material) was tested in vivo to determine relation between pore size and qualitative tissue response. Silicone-coated samples were also tested to determine the dependence of the observed tissue response on the implant surface chemistry. Results showed nonadherent, contracting capsules around implants having pore diameters smaller than 0.5 microns. Implants with pores ranging from 1.4 to 1.9 microns evoked thin, tightly adherent fibrous capsules without inflammatory cells. Porosities of 3.3 microns and larger became infiltrated with inflammatory tissue. Results indicate that the observed tissue response is predominantly dependent on implant surface topography and that variation in implant material may have little effect. It is concluded that a defined surface topography of 1 to 2 microns appears to allow direct fibroblast attachment to the surface independent of its chemical or electrochemical nature. Attached fibroblasts then produce a minimal connective tissue response to the implant and prevent or diminish the presence of inflammatory cells at the implant/tissue interface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inflammatory Response to Implants
Anderson, J. M. (1988) · ASAIO Journal · doi:10.1097/00002480-198804000-00005 · Cited by 591
Cited by
Effects of synthetic micro- and nano-structured surfaces on cell behavior
Flemming, R. G., Murphy, C. J., Abrams, G. A., Goodman, S. L., & Nealey, P. F. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00209-9 · Cited by 1,450
Keun Kwon, I., Kidoaki, S., & Matsuda, T. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.10.007 · Cited by 607
Neovascularization of synthetic membranes directed by membrane microarchitecture
Brauker, J. H., Carr‐Brendel, V. E., Martinson, L. A., Crudele, J., Johnston, W. D., & Johnson, R. C. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820291208 · Cited by 517
Wang, Y.-X., Robertson, J. L., Spillman, W. B., & Claus, R. O. (2004) · Pharmaceutical Research · doi:10.1023/b:pham.0000036909.41843.18 · Cited by 357
“1–3 m) could radically alter the cellular response in vivo (138) and in vitro (139).”
BackgroundWan, Y., Wang, Y., Liu, Z., Qu, X., Han, B., Bei, J., & Wang, S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.11.016 · Cited by 342
Bulk metallic glasses for biomedical applications
Schroers, J., Kumar, G., Hodges, T. M., Chan, S., & Kyriakides, T. R. (2009) · JOM · doi:10.1007/s11837-009-0128-1 · Cited by 325
Micro- and nanoscale structures for tissue engineering constructs
Desai, T. A. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(00)00087-4 · Cited by 302
Surface modification of polyester biomaterials for tissue engineering
Jiao, Y.-P., & Cui, F.-Z. (2007) · Biomedical Materials · doi:10.1088/1748-6041/2/4/r02 · Cited by 253
The Effect of Surface Topography on the Retention of Microorganisms
Whitehead, K. A., & Verran, J. (2006) · Food and Bioproducts Processing · doi:10.1205/fbp06035 · Cited by 244
Influence of the surface structure of titanium materials on the adhesion of fibroblasts
Eisenbarth, E., Meyle, J., Nachtigall, W., & Breme, J. (1996) · Biomaterials · doi:10.1016/0142-9612(96)87281-4 · Cited by 200
den Braber, E. T., de Ruijter, J. E., Smits, H. T. J., Ginsel, L. A., von Recum, A. F., & Jansen, J. A. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85910-2 · Cited by 198
Self-citationBiomaterial topography alters healing in vivo and monocyte/macrophage activation in vitro
Bota, P. C. S., Collie, A. M. B., Puolakkainen, P., Vernon, R. B., Sage, E. H., Ratner, B. D., & Stayton, P. S. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32893 · Cited by 186
“Capsule thickness varies around filters made of the same material but with different pore sizes.(12) Reduced fibrous-capsule formation, increased vascularity, and closer proximity of vessels to the implant surface have been demonstrated with pillar-textured implants and with porous polyvinyl alcohol implants in compar…”
BackgroundBiggs, M. J. P., Richards, R. G., McFarlane, S., Wilkinson, C. D. W., Oreffo, R. O. C., & Dalby, M. J. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0035 · Cited by 172
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500317 · Cited by 125
Reactions of cells at implant surfaces
van Blitterswijk, C. A., Bakker, D., Hesseling, S. C., & Koerten, H. K. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90198-j · Cited by 52
Surface patterning: Tool to modulate stem cell differentiation in an adipose system
Chaubey, A., Ross, K. J., Leadbetter, R. M., & Burg, K. J. L. (2008) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30846 · Cited by 50
Metadata
- Authors
- Campbell, C. E., & Von Recum, A. F.
- Venue
- Journal of Investigative Surgery
- Publisher
- Informa UK Limited
- Published
- 1989-01
- Volume
- 2
- Issue
- 1
- Pages
- 51-74
- ISSN
- 0894-1939 (ISSN-L)
- 1521-0553
- OpenAlex
- W1972617359
- Cited by
- 134
- References
- 1
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.