Hemolyzed specimens: a major challenge for emergency departments and clinical laboratories
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
The term hemolysis designates the pathological process of breakdown of red blood cells in blood, which is typically accompanied by varying degrees of red tinge in serum or plasma once the whole blood specimen has been centrifuged. Hemolyzed specimens are a rather frequent occurrence in laboratory practice, and the rate of hemolysis is remarkably higher in specimens obtained in the Emergency Department (ED) as compared with other wards or outpatient phlebotomy services. Although hemolyzed specimens may reflect the presence of hemolytic anemia, in most cases they are due to preanalytical sources related to incorrect procedures or failure to follow procedures for collection, handling and storage of the samples; some of these are typical of the ED. Since hemolyzed specimens are often an important cause of relationship, economic, organizational and clinical problems between the ED and the clinical laboratory, it is essential to develop effective processes for systematically identifying unsuitable specimens (e.g. by using the hemolysis index), differentiating in vitro from in vivo hemolysis, troubleshooting the potential causes, and maintaining good relations between the clinical laboratory and the ED.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global epidemiology of haemoglobin disorders and derived service indicators
Modell, B. (2008) · Bulletin of the World Health Organization · doi:10.2471/blt.06.036673 · Cited by 1,924
Identification of the haemoglobin scavenger receptor
Kristiansen, M., Graversen, J. H., Jacobsen, C., Sonne, O., Hoffman, H.-J., Law, S. K. A., & Moestrup, S. K. (2001) · Nature · doi:10.1038/35051594 · Cited by 1,712
Current databases on biological variation: pros, cons and progress
C. Ricós, V. A. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519950185229 · Cited by 987
Biological and clinical significance of haptoglobin polymorphism in humans
Langlois, M. R., & Delanghe, J. R. (1996) · Clinical Chemistry · doi:10.1093/clinchem/42.10.1589 · Cited by 930
Gehrs, B. C., & Friedberg, R. C. (2002) · American Journal of Hematology · doi:10.1002/ajh.10062 · Cited by 647
Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories
Lippi, G., Blanckaert, N., Bonini, P., Green, S., Kitchen, S., Palicka, V., Vassault, A. J., & Plebani, M. (2008) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2008.170 · Cited by 466 · cited 1×
“(Received 09 June 2011; revised 17 June 2011; accepted 17 June 2011) Critical Reviews in Clinical Laboratory Sciences, 2011; 48(3): 143–153 © 2011 Informa Healthcare USA, Inc.”
BackgroundSelf-citationGlucose-6-phosphate dehydrogenase deficiency
Mehta, A., Mason, P. J., & Vulliamy, T. J. (2000) · Best Practice & Research Clinical Haematology · doi:10.1053/beha.1999.0055 · Cited by 321
Sickle cell vaso-occlusion: multistep and multicellular paradigm
Frenette, P. S. (2002) · Current Opinion in Hematology · doi:10.1097/00062752-200203000-00003 · Cited by 274
G6PD: Population genetics and clinical manifestations
Beutler, E. (1996) · Blood Reviews · doi:10.1016/s0268-960x(96)90019-3 · Cited by 239
Hemolyzed Specimens: A Reason for Rejection or a Clinical Challenge?
Carraro, P., Servidio, G., & Plebani, M. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.2.306 · Cited by 218
Self-citation
Cited by
Lippi, G., von Meyer, A., Cadamuro, J., & Simundic, A.-M. (2019) · Diagnosis · doi:10.1515/dx-2018-0018 · Cited by 135
Self-citationLima-Oliveira, G., Volanski, W., Lippi, G., Picheth, G., & Guidi, G. C. (2017) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2017.1295317 · Cited by 117
Self-citationPreanalytical considerations in blood gas analysis
Baird, G. (2013) · Biochemia Medica · doi:10.11613/bm.2013.005 · Cited by 90
“One of the more common sources of interference in laboratory testing, hemolysis, is introduced during collection by shearing of red cells, and it is a potential source of interference in blood gas testing (41,42).”
BackgroundLippi, G., Cervellin, G., & Mattiuzzi, C. (2013) · Biochemia Medica · doi:10.11613/bm.2013.022 · Cited by 66
“jority of hemolyzed specimens come from the emergency department (ED), where the relative prevalence can be as high as 8-12% (6).”
BackgroundSelf-citationPrevalence and cost of hemolyzed samples in a large urban emergency department
Lippi, G., Bonelli, P., & Cervellin, G. (2014) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12135 · Cited by 27
“The presence of spurious hemolysis in diagnostic samples causes a variety of organizational and clinical issues [8], mainly attributable to the fact that many test results must be suppressed, thus requiring recollection of additional specimens, generating diagnostics delays, and contributing to overcrowding in ED [9].”
BackgroundSelf-citationMrazek, C., Simundic, A.-M., Wiedemann, H., Krahmer, F., Felder, T. K., Kipman, U., Hoppe, U., Haschke-Becher, E., & Cadamuro, J. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0940 · Cited by 24
Avoidance to wipe alcohol before venipuncture is not a source of spurious hemolysis
Salvagno, G. L., Danese, E., Lima-Oliveira, G., Guidi, G. C., & Lippi, G. (2013) · Biochemia Medica · doi:10.11613/bm.2013.023 · Cited by 20
“, generating a burning sensation during skin perforation) and, especially, on the conceptual evidence notion that aspiration of alcohol through the collection needle into blood containers may cause spurious hemolysis, which is the leading source of unsuitable specimens in clinical laboratories (8,9).”
BackgroundSelf-citationNigro, M., Valli, G., Marchionne, M. L., Sattarinia, D., Silvestrini, F., De Pietro, D., Fazzini, S., Roselli, G., Spallino, A., Praticò, V., et al. (2022) · Medicina · doi:10.3390/medicina59010066 · Cited by 16
“A survey promoted by the Working Group on Laboratory Errors and Patient Safety (WG-LEPS) of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) [4] and the Global Preanalytical Scientific Committee (GPSC) [5], involving 391 clinical laboratories around the world, showed that approximately…”
Background
Metadata
- Authors
- Lippi, G., Plebani, M., Di Somma, S., & Cervellin, G.
- Venue
- Critical Reviews in Clinical Laboratory Sciences
- Publisher
- Informa UK Limited
- Published
- 2011-06
- Volume
- 48
- Issue
- 3
- Pages
- 143-153
- ISSN
- 1040-8363 (ISSN-L)
- 1549-781X
- OpenAlex
- W2100151973
- Cited by
- 226
- References
- 32
- FWCI
- 1.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.