CoChat

Blood pressure effects of CPAP in nonresistant and resistant hypertension associated with OSA: A systematic review of randomized clinical trials

Feldstein, Carlos A. · 2016 · Clinical and Experimental Hypertension
Cited by 51

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

Obstructive sleep apnea (OSA) is a rather common chronic disorder, associated with increased prevalence of hypertension. The pathophysiological mechanisms for hypertension in OSA are at least in part linked to intermittent hypoxia developed during nightly hypopneas and apneas. Hypoxemia stimulates sympathetic overactivity, systemic inflammation, oxidative stress, and endothelial dysfunction. However, it appears that intermittent hypoxemia is not the only factor in the development of hypertension in OSA. Supplemental oxygen therapy that improved oxyhemoglobin saturation to similar levels to those achieved with CPAP treatment did not reduce BP. In this scenario, it could be proposed that hypoxemia acts as a trigger of sympathetic overdrive, which when set is the main factor in the development of hypertension in OSA. This review appraises evidence provided by randomized controlled trials on the BP-lowering effectiveness of continuous positive airway pressure (CPAP) treatment of OSA patients with nonresistant and resistant hypertension. It suggests that CPAP treatment is more effective in treating resistant hypertension than nonresistant hypertension. A possible explanation is that sympathetic overactivity and altered vascular reactivity in OSA could be more severe in resistant hypertension than in nonresistant hypertension. An intricate interaction among compliance, adherence, and their interaction with demographic characteristics, genetic factors, and comorbidities of the population included might explain the differences found between trials on their influence over the antihypertensive effectiveness of CPAP. Further long-term trials are needed in hypertensive OSA patients to assess whether CPAP treatment in OSA patients consistently restores physiological nocturnal BP fall and adjusts resting and circadian heart rate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/10641963.2016.1148156

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 51

Metadata

Authors
Feldstein, C. A.
Venue
Clinical and Experimental Hypertension
Published
2016-05-09
Volume
38
Issue
4
Pages
337-346
ISSN
  • 0148-3927 (ISSN-L)
  • 1064-1963
  • 1525-6006
OpenAlex
W2346080265
Cited by
51
References
21
FWCI
1.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.