Biocompatibility of a Silicon Based Peripheral Nerve Electrode
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The biocompatibility of a silicon neuroelectric interface for chronic use in mammalian peripheral nerves was investigated. New Zealand white rabbits were used as the animal model. The implant was made of (110) silicon coated with one micron of silicon dioxide. An anisotropic etch was used to form a grid of ten silicon bars each 40 microns wide and spaced 160 microns apart. A Silastic nerve cuff was molded onto each side of the grid. Using microsurgical techniques, the nerve was transected and sutured into the implant cuff. One implanted rabbit was completely analyzed and is reported here. By 32 days post operatively, the EMG of the affected muscles had partially recovered. The EMG of the affected muscles was indistinguishable from the contralateral control muscles after 150 days. At 332 days, the conduction properties of the implanted nerve confirmed that the nerve was capable of conduction through the silicon grid. Histological observations were consistent with normal peripheral nerve regeneration following microsurgical neurrorhaphy. Seven additional rabbits have been implanted and will be fully analyzed in the future. It was concluded that the silicon peripheral nerve implant described here should be pursued as a substrate for a chronic neuroelectric interface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Loeb, G. E., Marks, W. B., & Beatty, P. G. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442964 · Cited by 46
Cited by
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 479
Self-citationEvaluation of MEMS materials of construction for implantable medical devices
Kotzar, G., Freas, M., Abel, P., Fleischman, A., Roy, S., Zorman, C., Moran, J. M., & Melzak, J. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00007-8 · Cited by 439
Edell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177
Self-citationChronically implanted intrafascicular recording electrodes
Lefurge, T., Goodall, E., Horch, K., Stensaas, L., & Schoenberg, A. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02368469 · Cited by 172
“through which transected nerve fibers are expected to grow (5,7).”
BackgroundThe foreign body response to the Utah Slant Electrode Array in the cat sciatic nerve
Christensen, M. B., Pearce, S. M., Ledbetter, N. M., Warren, D. J., Clark, G. A., & Tresco, P. A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.010 · Cited by 135
Metadata
- Authors
- Edell, D. J., Churchill, J. N., & Gourley, I. M.
- Venue
- Biomaterials, Medical Devices, and Artificial Organs
- Publisher
- Informa UK Limited
- Published
- 1982-01
- Volume
- 10
- Issue
- 2
- Pages
- 103-122
- ISSN
- 0090-5488 (ISSN-L)
- OpenAlex
- W2283913414
- Cited by
- 32
- References
- 1
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biocompatibility of a Silicon Based Peripheral Nerve Electrode. https://app.cochat.ai/papers/10.3109/10731198209118775
- The paper
- Edell, D. J., Churchill, J. N., & Gourley, I. M. (1982). Biocompatibility of a Silicon Based Peripheral Nerve Electrode. Biomaterials, Medical Devices, and Artificial Organs. https://doi.org/10.3109/10731198209118775
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.