Mechanical Property Distributions in the Cancellous Bone of the Human Proximal Femur
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Proximal femurs obtained at routine autopsy were sectioned into large numbers of 5 mm cubic specimens, in order to obtain detailed quantitative information about the spatial and directional variations of the material properties of the cancellous bone. Low strain rate compression tests were performed, evaluating the apparent elastic modulus and yield strength, in three perpendicular testing directions, for each cube. A computer contouring program was used to assemble the experimental data into smoothed distribution plots across sections of interest.The results revealed stiffness and strength elevations/reductions which clearly correspond to roentgenographic features. Especially prominent stiffness elevations (160 to 400 percent above the overall cancellous bone average) were found in the regions traversed by the primary trabeculation system, although the modulus of the bone samples was substantially reduced when measured in directions other than those of habitual weight-bearing. Similar but less pronounced effects were observed for the arcuate trabeculation system. Conversely, Wards triangle and the intertrochanteric regions exhibited significant (as much as 40 to 90 percent below average) stiffness and strength reductions.There was close qualitative agreement between the stiffness and yield strength distributions for all sections examined. This phenomenon was found to be a corollary of the remarkably linear proportionality between the modulus and yield strength values for individual compression tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Theory of Elasticity of an Anisotropic Elastic Body
Lekhnitskii, S. G., Fern, P., Brandstatter, J. J., & Dill, E. H. (1964) · Physics Today · doi:10.1063/1.3051394 · Cited by 1,492
A First Course in Continuum Mechanics
Gonzalez, O., & Stuart, A. M. (2001) · Cambridge University Press eBooks · doi:10.1017/cbo9780511619571 · Cited by 601
ROLE OF MECHANICAL FACTORS IN PATHOGENESIS OF PRIMARY OSTEOARTHRITIS
Radin, E., Paul, I., & Rose, R. (1972) · The Lancet · doi:10.1016/s0140-6736(72)90179-1 · Cited by 593
A first course in continuum mechanics
Fung, Y. C. (1969) · Medical Entomology and Zoology · Cited by 550
Physical properties of trabecular bone
Galante, J., Rostoker, W., & Ray, R. D. (1970) · Calcified Tissue Research · doi:10.1007/bf02017552 · Cited by 302
On the mathematical analysis of stress in the human femur
Rybicki, E. F., Simonen, F. A., & Weis, E. B. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90056-5 · Cited by 286
Mechanical Properties of Dried Defatted Spongy Bone
Lindahl, O. (1976) · Acta Orthopaedica Scandinavica · doi:10.3109/17453677608998966 · Cited by 194
Buckling studies of single human trabeculae
Townsend, P. R., Rose, R. M., & Radin, E. L. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90025-1 · Cited by 192
Variations in strength and structure of cancellous bone at the knee
Behrens, J. C., Walker, P. S., & Shoji, H. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90010-4 · Cited by 171
Cited by
Biomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 801
Three-dimensional methods for quantification of cancellous bone architecture
Odgaard, A. (1997) · Bone · doi:10.1016/s8756-3282(97)00007-0 · Cited by 777
The relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
“Brown and Ferguson (1980) found a strong linear correlation between yield stress and modulus for specimens taken from different regions of the proximal femur.”
BackgroundThe mechanical properties of trabecular bone: Dependence on anatomic location and function
Goldstein, S. A. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90023-6 · Cited by 687
Predicting the compressive mechanical behavior of bone
Keller, T. S. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90056-6 · Cited by 667
Biomechanics and Mechanobiology of Trabecular Bone: A Review
Oftadeh, R., Perez-Viloria, M., Villa-Camacho, J. C., Vaziri, A., & Nazarian, A. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029176 · Cited by 547
Misch, C. E., Qu, Z., & Bidez, M. W. (1999) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0278-2391(99)90437-8 · Cited by 509
Relationships between loading history and femoral cancellous bone architecture
Carter, D. R., Orr, T. E., & Fyhrie, D. P. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90091-2 · Cited by 426
Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090507 · Cited by 401
Sex differences in age‐related remodeling of the femur and tibia
Ruff, C. B., & Hayes, W. C. (1988) · Journal of Orthopaedic Research · doi:10.1002/jor.1100060613 · Cited by 402
Automated three-dimensional finite element modelling of bone: a new method
Keyak, J. H., Meagher, J. M., Skinner, H. B., & Mote, C. D. (1990) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(90)90022-f · Cited by 383
Majumdar, S., Kothari, M., Augat, P., Newitt, D. C., Link, T. M., Lin, J. C., Lang, T., Lu, Y., & Genant, H. K. (1998) · Bone · doi:10.1016/s8756-3282(98)00030-1 · Cited by 331
Keaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330
A 20-Year Perspective on the Mechanical Properties of Trabecular Bone
Keaveny, T. M., & Hayes, W. C. (1993) · Journal of Biomechanical Engineering · doi:10.1115/1.2895536 · Cited by 318
Determinants of the mechanical properties of bones
Martin, R. B. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90379-2 · Cited by 316
Lotz, J. C., Cheal, E. J., & Hayes, W. C. (1995) · Osteoporosis International · doi:10.1007/bf01774015 · Cited by 314
Goldstein, S. A., Goulet, R., & McCubbrey, D. (1993) · Calcified Tissue International · doi:10.1007/bf01673421 · Cited by 310
The mechanical properties of human tibial trabecular bone as a function of metaphyseal location
Goldstein, S. A., Wilson, D. L., Sonstegard, D. A., & Matthews, L. S. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90097-0 · Cited by 292
Broadband ultrasound attenuation signals depend on trabecular orientation: An in vitro study
Glüer, C. C., Wu, C. Y., & Genant, H. K. (1993) · Osteoporosis International · doi:10.1007/bf01623674 · Cited by 272
Heterogeneity of bone lamellar-level elastic moduli
Hoffler, C. E., Moore, K. E., Kozloff, K., Zysset, P. K., Brown, M. B., & Goldstein, S. A. (2000) · Bone · doi:10.1016/s8756-3282(00)00268-4 · Cited by 259
Young's modulus, bending strength, and tissue physical properties of human compact bone
Keller, T. S., Mao, Z., & Spengler, D. M. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080416 · Cited by 230
The underestimation of Young's modulus in compressive testing of cancellous bone specimens
Odgaard, A., & Linde, F. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90333-i · Cited by 225
Cheal, E. J., Spector, M., & Hayes, W. C. (1992) · Journal of Orthopaedic Research · doi:10.1002/jor.1100100314 · Cited by 213
Mechanical properties of trabecular bone. Dependency on strain rate
Linde, F., Nørgaard, P., Hvid, I., Odgaard, A., & Søballe, K. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90305-7 · Cited by 171
Luz, G. M., & Mano, J. F. (2010) · Composites Science and Technology · doi:10.1016/j.compscitech.2010.05.013 · Cited by 161
“6 much as 310MPa and those from non-weight-bearing regions typically fail at stresses of from 120MPa to 150MPa [18].”
BackgroundTrabecular bone modulus and strength can depend on specimen geometry
Keaveny, T. M., Borchers, R. E., Gibson, L. J., & Hayes, W. C. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90059-n · Cited by 160
Uniaxial yield strains for bovine trabecular bone are isotropic and asymmetric
Chang, W. C. W., Christensen, T. M., Pinilla, T. P., & Keaveny, T. M. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170418 · Cited by 77
Heterogeneity of yield strain in low-density versus high-density human trabecular bone
Bevill, G., Farhamand, F., & Keaveny, T. M. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.05.023 · Cited by 57
“Early work performed with high-density human (Brown and Ferguson, 1980) and canine (Vahey et al.”
Background
Metadata
- Authors
- Brown, T. D., & Ferguson, A. B.
- Venue
- Acta Orthopaedica Scandinavica
- Publisher
- Medical Journals Sweden AB
- Published
- 1980-01
- Volume
- 51
- Issue
- 1-6
- Pages
- 429-437
- ISSN
- 0001-6470 (ISSN-L)
- OpenAlex
- W2142605719
- Cited by
- 282
- References
- 14
- FWCI
- 11.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.