Osseointegrated Titanium Implants:Requirements for Ensuring a Long-Lasting, Direct Bone-to-Implant Anchorage in Man
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
A total of 2895 threaded, cylindrical titanium implants have been inserted into the mandible or the maxilla and 124 similar implants have been installed in the tibial, temporal or iliac bones in man for various bone restorative procedures. The titanium screws were implanted without the use of cement, using a meticulous technique aiming at osseointegration--a direct contact between living bone and implant. Thirty-eight stable and integrated screws were removed for various reasons from 18 patients. The interface zone between bone and implant was investigated using X-rays, SEM, TEM and histology. The SEM study showed a very close spatial relationship between titanium and bone. The pattern of the anchorage of collagen filaments to titanium appeared to be similar to that of Sharpey's fibres to bone. No wear products were seen in the bone or soft tissues in spite of implant loading times up to 90 months. The soft tissues were also closely adhered to the titanium implant, thereby forming a biological seal, preventing microorganism infiltration along the implant. The implants in many cases had been allowed to permanently penetrate the gingiva and skin. This caused no adverse tissue effects. An intact bone-implant interface was analyzed by TEM, revealing a direct bone-to-implant interface contact also at the electron microscopic level, thereby suggesting the possibility of a direct chemical bonding between bone and titanium. It is concluded that the technique of osseointegration is a reliable type of cement-free bone anchorage for permanent prosthetic tissue substitutes. At present, this technique is being tried in clinical joint reconstruction. In order to achieve and to maintain such a direct contact between living bone and implant, threaded, unalloyed titanium screws of defined finish and geometry were inserted using a delicate surgical technique and were allowed to heal in situ, without loading, for a period of at least 3--4 months.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A low-viscosity epoxy resin embedding medium for electron microscopy
Spurr, A. R. (1969) · Journal of Ultrastructure Research · doi:10.1016/s0022-5320(69)90033-1 · Cited by 12,865
A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
Adell, R., Lekholm, U., Rockler, B., & Brånemark, P.-I. (1981) · International Journal of Oral Surgery · doi:10.1016/s0300-9785(81)80077-4 · Cited by 4,816
Self-citationIntra-Osseous Anchorage of Dental Prostheses:I. Experimental Studies
Brånemark, P.-I., Breine, U., Adell, R., Hansson, B. O., Lindström, J., & Ohlsson, Å. (1969) · Scandinavian Journal of Plastic and Reconstructive Surgery · doi:10.3109/02844316909036699 · Cited by 1,811
Self-citationTemperatures Measured in Human Cortical Bone when Drilling
MATTHEWS, L. S., & HIRSCH, C. (1972) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197254020-00008 · Cited by 472
The Nine and Ten Year Results of the Low-Friction Arthroplasty of the Hip
CHARNLEY, J., & CUPIC, Z. (1973) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197309000-00003 · Cited by 348
Brunski, J., Moccia, A. F., Pollack, S. R., Korostoff, E., & Trachtenberg, D. I. (1979) · Journal of Dental Research · doi:10.1177/00220345790580100301 · Cited by 173
Reconstruction of the Defective Mandible
Brånemark, P.-I., Lindström, J., Hallén, O., Breine, U., Jeppson, P.-H., & Öhman, A. (1975) · Scandinavian Journal of Plastic and Reconstructive Surgery · doi:10.3109/02844317509022776 · Cited by 168
Self-citation
Research works printed but not linked: 83
- Adell R, 1974, Scand. J. Plast. Reconstr. Surg., 8, 11
- Adell R., 1981, Int. J. Oral. Surg.
- Albrektsson T., 1978, Scand. J. Plast. Reconstr. Surg., 12, 215, 10.3109/02844317809012997 · doi:10.3109/02844317809012997
- Albrektsson T, 1979, Healing of bone grafts. Thesis
- Amstutz H. C, 1973, Orthop. Clin. North Am., 4, 235, 10.1016/S0030-5898(20)30791-4 · doi:10.1016/s0030-5898(20)30791-4
- Anderson J. M., 1980, First World Biomaterials Congress
- Armitage J. E., 1971, Oral. Surg., 32, 558, 10.1016/0030-4220(71)90321-5 · doi:10.1016/0030-4220(71)90321-5
- Atmaram G. H., 1979, Biomater. Med. Devices Artif. Organs, 7, 99, 10.3109/10731197909119376 · doi:10.3109/10731197909119376
- Babbusch C. A, 1973, Oral. Implantol., 3, 261
- Babbusch C. A., 1974, Oral. Implantol., 4, 373
- Baumhammers A., 1971, Oral. Implantol., 2, 25
- Breine U., 1980, Scand. J. Plast. Reconstr. Surg., 14, 23, 10.3109/02844318009105733 · doi:10.3109/02844318009105733
- Brettle J, 1970, Injury, 2, 26, 10.1016/S0020-1383(70)80110-3 · doi:10.1016/s0020-1383(70)80110-3
- Brunski J. B., 1979, J. Dent. Res., 58, 1953, 10.1177/00220345790580100201 · doi:10.1177/00220345790580100201
- Brånemark P.-I., 1970, Scand. J. Plast. Reconstr. Surg., 4, 100, 10.3109/02844317009038452 · doi:10.3109/02844317009038452
- Brånemark P.-I., 1977, Scand. J. Plast. Reconstr. Surg., 11, 16
- Brånemark P.-I., 1981, Scand. J. Plast. Reconstr. Surg.
- Busceni P., 1976, An investigation of bonding mechanisms of the interface of a prosthetic material
- Cameron H. U., 1973, J. Biomed. Mater. Res., 7, 301, 10.1002/jbm.820070404 · doi:10.1002/jbm.820070404
- Charnley J, 1973, Clin. Orthop., 95, 9
- Clarke E. G.C., 1953, J. Bone Joint Surg., 35, 467, 10.1302/0301-620X.35B3.467 · doi:10.1302/0301-620x.35b3.467
- Collins D. H, 1954, J. Bone Joint Surg., 36, 458, 10.1302/0301-620X.36B3.458 · doi:10.1302/0301-620x.36b3.458
- Cook H. P, 1967, Ann. R. Coll. Surg. Engl., 42, 233
- Costich E. R., 1964, Oral. Surg., 17, 563, 10.1016/0030-4220(64)90359-7 · doi:10.1016/0030-4220(64)90359-7
- Driskell T. D, 1973, DHEW publication, 65, 226
- Ducheyne P., 1979, Arch. Orthop. Traumat. Surg., 94, 155, 10.1007/BF00618439 · doi:10.1007/bf00618439
- Emnéus H, 1967, Acta Orthop. Scand., 38, 368, 10.3109/17453676708989650 · doi:10.3109/17453676708989650
- Emnéus H., 1967, Some aspects on titanium as an implant material. Communications from Avesta Jernverk AB
- Emnéus H., 1967, Acta Orthop. Scand., 38, 373
- Ferraro J. W, 1979, Plast. Reconstr. Surg., 63, 634, 10.1097/00006534-197905000-00005 · doi:10.1097/00006534-197905000-00005
- Fister J., 1980, Oral. Surg., 49, 105, 10.1016/0030-4220(80)90300-X · doi:10.1016/0030-4220(80)90300-x
- Freeman J. W, 1972, South Carolina Dent. J., 30, 10
- Giro C, 1974, Oral. Implantol., 4, 104
- Griss P., 1975, J. Biomed. Mater. Symp., 6, 177, 10.1002/jbm.820090421 · doi:10.1002/jbm.820090421
- Grundschober F., 1980, Long-term osseous anchorage of endosseous dental implants made of titanium and tantalum
- Hagert C.-G, 1975, Diss. Göteborg.
- Hille G. H, 1966, J. Materials, 1, 373
- Hobkirk J. A., 1977, J. Oral. Surg., 35, 968
- Homsy C. A., 1973, J. Am. Dent. Assoc., 86, 817, 10.14219/jada.archive.1973.0166 · doi:10.14219/jada.archive.1973.0166
- Hughes A. N., 1973, Injury, 4, 25, 10.1016/S0020-1383(72)80007-X · doi:10.1016/s0020-1383(72)80007-x
- Jacobs C. H., 1976, J. Biomech., 9, 343, 10.1016/0021-9290(76)90056-7 · doi:10.1016/0021-9290(76)90056-7
- Jacobs H. G, 1976, Implantologie und Zahnersatz
- Jacobs H. G, 1977, Dtsch. Zahnäntl Z., 36, 63
- Jacobs H. G, 1979, ZM Fortbildung, 5, 254
- Jacobs C. H, 1977, Proc. Bull Hosp. Joint Dis., 38, 4
- Jacobs R. L., 1972, Arch. Surg., 104, 687, 10.1001/archsurg.1972.04180050061014 · doi:10.1001/archsurg.1972.04180050061014
- Judet R., 1978, Clin. Orthop., 137, 76
- Juillerat D. A., 1977, Diss. Univ. Bern 1977.
- Karagianes M. T., 1976, J. Dent. Res., 55, 85, 10.1177/00220345760550013001 · doi:10.1177/00220345760550013001
- Klawitter J. J., 1974, Acta Orthop. Belg., 40, 755
- Krause W, 1977, Proc. Bull. Hosp. Joint. Dis., 38, 5
- Laing P. G., 1967, J. Biomed. Mater. Res., 1, 135, 10.1002/jbm.820010113 · doi:10.1002/jbm.820010113
- Ledermann Ph, 1979, Dtsch. Zahnärztl. Z., 34, 907
- Linder L., 1975, Injury, 6, 277, 10.1016/0020-1383(75)90174-6 · doi:10.1016/0020-1383(75)90174-6
- Linder L, 1976, Bone cement monomer. Thesis
- Linder L, 1980, Biocompatibility of orthopaedic implants, Vol. II
- Lindström J., 1981, Scand. J. Plast. Reconstr. Surg.
- Linkow L. I., 1973, Oral. Implantol., 3, 281
- Linkow L. I., 1970, Theories and techniques of oral implantology
- Lord G. A., 1979, Clin. Orthop., 141, 2
- McQuillian A. D., 1956, Metallurgy of the rarer metals. 4: Titanium
- Moss R. W, 1964, Oral. Surg., 17, 405, 10.1016/0030-4220(64)90515-8 · doi:10.1016/0030-4220(64)90515-8
- Muster D., 1978, Actualités Odonto-Stomat., 121, 109
- Nixon J, 1975, Oral. Implantol., 5, 370
- Pallan F. G, 1960, J. Oral. Surg., 18, 400
- Predecki P., 1972, J. Biomed. Mater. Res., 6, 401, 10.1002/jbm.820060507 · doi:10.1002/jbm.820060507
- Ring P. A, 1978, Clin. Orthop., 137, 87
- Ritter H., 1979, Acta Orthop, Traumat. Surg., 95, 89, 10.1007/BF00379175 · doi:10.1007/bf00379175
- Salzer M., 1979, Arch. Orthop. Traumat. Surg., 93, 169, 10.1007/BF00523668 · doi:10.1007/bf00523668
- Schatzker J. G., 1975, Clin. Orthop., 111, 257, 10.1097/00003086-197509000-00032 · doi:10.1097/00003086-197509000-00032
- Schroeder A., 1976, Schweiz Mschr. Zahnheilk., 86, 713
- Schroeder A., 1978, Schweiz. Mschr. Zahnheilk., 88, 1051
- Solar R. J., 1979, J. Biomed. Mater. Res., 12, 217, 10.1002/jbm.820130206 · doi:10.1002/jbm.820130206
- Southam J. C., 1970, Brit. J. Oral. Surg., 8, 211, 10.1016/S0007-117X(70)80082-8 · doi:10.1016/s0007-117x(70)80082-8
- Swanson A. B, 1973, Flexible implant resection arthroplasty in the hand and extremities
- Swanson A. B., 1977, The scientific basis of joint replacement
- Tjellström A., 1978, Acta Otolaryng. (Stockh.), 85, 33, 10.3109/00016487809121420 · doi:10.3109/00016487809121420
- Tjellström A., 1978, Acta Otolaryng. (Stockh.), 85, 232, 10.3109/00016487809111930 · doi:10.3109/00016487809111930
- Tjellström A., 1981, Laryngoscope
- Tjellström A., 1981, Am. J. Otol.
- Thompson H. C, 1958, J. Oral. Surg., 16, 22
- Uhthoff H. K, 1973, J. Bone Joint Surg., 55, 633, 10.1302/0301-620X.55B3.633 · doi:10.1302/0301-620x.55b3.633
- Weiss M. B, 1977, Quintess int., 10
Cited by
Items 101–106 of 106
Health, Maintenance, and Recovery of Soft Tissues around Implants
Wang, Y., Zhang, Y., & Miron, R. J. (2016) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12343 · Cited by 161
Takeuchi, K., Saruwatari, L., Nakamura, H. K., Yang, J., & Ogawa, T. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30227 · Cited by 159
Chen, J., Zhang, X., Huang, C., Cai, H., Hu, S., Wan, Q., Pei, X., & Wang, J. (2017) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35960 · Cited by 150
Fit and forget: The future of dental implant therapy via nanotechnology
Gulati, K., Chopra, D., Kocak-Oztug, N. A., & Verron, E. (2023) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2023.114900 · Cited by 89
Alrabeah, G. O., Brett, P., Knowles, J. C., & Petridis, H. (2017) · Journal of Dentistry · doi:10.1016/j.jdent.2017.08.002 · Cited by 85
Osseodensification technique in crestal maxillary sinus elevation—A narrative review
Gaspar, J., Mazor, Z., & Bonfante, E. A. (2025) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.13399 · Cited by 17
Metadata
- Authors
- Albrektsson, T., Brånemark, P.-I., Hansson, H.-A., & Lindström, J.
- Venue
- Acta Orthopaedica Scandinavica
- Published
- 1981-01
- Volume
- 52
- Issue
- 2
- Pages
- 155-170
- ISSN
- 0001-6470 (ISSN-L)
- OpenAlex
- W2151005356
- Cited by
- 2,690
- References
- 7
- FWCI
- 32.18
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.