CoChat

Osseointegrated Titanium Implants:Requirements for Ensuring a Long-Lasting, Direct Bone-to-Implant Anchorage in Man

Open access
Albrektsson, T., Brånemark, P.-I., Hansson, H.-A., Lindström, J. · 1981 · Acta Orthopaedica Scandinavica
Cited by 2,690

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

A total of 2895 threaded, cylindrical titanium implants have been inserted into the mandible or the maxilla and 124 similar implants have been installed in the tibial, temporal or iliac bones in man for various bone restorative procedures. The titanium screws were implanted without the use of cement, using a meticulous technique aiming at osseointegration--a direct contact between living bone and implant. Thirty-eight stable and integrated screws were removed for various reasons from 18 patients. The interface zone between bone and implant was investigated using X-rays, SEM, TEM and histology. The SEM study showed a very close spatial relationship between titanium and bone. The pattern of the anchorage of collagen filaments to titanium appeared to be similar to that of Sharpey's fibres to bone. No wear products were seen in the bone or soft tissues in spite of implant loading times up to 90 months. The soft tissues were also closely adhered to the titanium implant, thereby forming a biological seal, preventing microorganism infiltration along the implant. The implants in many cases had been allowed to permanently penetrate the gingiva and skin. This caused no adverse tissue effects. An intact bone-implant interface was analyzed by TEM, revealing a direct bone-to-implant interface contact also at the electron microscopic level, thereby suggesting the possibility of a direct chemical bonding between bone and titanium. It is concluded that the technique of osseointegration is a reliable type of cement-free bone anchorage for permanent prosthetic tissue substitutes. At present, this technique is being tried in clinical joint reconstruction. In order to achieve and to maintain such a direct contact between living bone and implant, threaded, unalloyed titanium screws of defined finish and geometry were inserted using a delicate surgical technique and were allowed to heal in situ, without loading, for a period of at least 3--4 months.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/17453678108991776

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Research works printed but not linked: 83

  1. Adell R, 1974, Scand. J. Plast. Reconstr. Surg., 8, 11
  2. Adell R., 1981, Int. J. Oral. Surg.
  3. Albrektsson T., 1978, Scand. J. Plast. Reconstr. Surg., 12, 215, 10.3109/02844317809012997 · doi:10.3109/02844317809012997
  4. Albrektsson T, 1979, Healing of bone grafts. Thesis
  5. Amstutz H. C, 1973, Orthop. Clin. North Am., 4, 235, 10.1016/S0030-5898(20)30791-4 · doi:10.1016/s0030-5898(20)30791-4
  6. Anderson J. M., 1980, First World Biomaterials Congress
  7. Armitage J. E., 1971, Oral. Surg., 32, 558, 10.1016/0030-4220(71)90321-5 · doi:10.1016/0030-4220(71)90321-5
  8. Atmaram G. H., 1979, Biomater. Med. Devices Artif. Organs, 7, 99, 10.3109/10731197909119376 · doi:10.3109/10731197909119376
  9. Babbusch C. A, 1973, Oral. Implantol., 3, 261
  10. Babbusch C. A., 1974, Oral. Implantol., 4, 373
  11. Baumhammers A., 1971, Oral. Implantol., 2, 25
  12. Breine U., 1980, Scand. J. Plast. Reconstr. Surg., 14, 23, 10.3109/02844318009105733 · doi:10.3109/02844318009105733
  13. Brettle J, 1970, Injury, 2, 26, 10.1016/S0020-1383(70)80110-3 · doi:10.1016/s0020-1383(70)80110-3
  14. Brunski J. B., 1979, J. Dent. Res., 58, 1953, 10.1177/00220345790580100201 · doi:10.1177/00220345790580100201
  15. Brånemark P.-I., 1970, Scand. J. Plast. Reconstr. Surg., 4, 100, 10.3109/02844317009038452 · doi:10.3109/02844317009038452
  16. Brånemark P.-I., 1977, Scand. J. Plast. Reconstr. Surg., 11, 16
  17. Brånemark P.-I., 1981, Scand. J. Plast. Reconstr. Surg.
  18. Busceni P., 1976, An investigation of bonding mechanisms of the interface of a prosthetic material
  19. Cameron H. U., 1973, J. Biomed. Mater. Res., 7, 301, 10.1002/jbm.820070404 · doi:10.1002/jbm.820070404
  20. Charnley J, 1973, Clin. Orthop., 95, 9
  21. Clarke E. G.C., 1953, J. Bone Joint Surg., 35, 467, 10.1302/0301-620X.35B3.467 · doi:10.1302/0301-620x.35b3.467
  22. Collins D. H, 1954, J. Bone Joint Surg., 36, 458, 10.1302/0301-620X.36B3.458 · doi:10.1302/0301-620x.36b3.458
  23. Cook H. P, 1967, Ann. R. Coll. Surg. Engl., 42, 233
  24. Costich E. R., 1964, Oral. Surg., 17, 563, 10.1016/0030-4220(64)90359-7 · doi:10.1016/0030-4220(64)90359-7
  25. Driskell T. D, 1973, DHEW publication, 65, 226
  26. Ducheyne P., 1979, Arch. Orthop. Traumat. Surg., 94, 155, 10.1007/BF00618439 · doi:10.1007/bf00618439
  27. Emnéus H, 1967, Acta Orthop. Scand., 38, 368, 10.3109/17453676708989650 · doi:10.3109/17453676708989650
  28. Emnéus H., 1967, Some aspects on titanium as an implant material. Communications from Avesta Jernverk AB
  29. Emnéus H., 1967, Acta Orthop. Scand., 38, 373
  30. Ferraro J. W, 1979, Plast. Reconstr. Surg., 63, 634, 10.1097/00006534-197905000-00005 · doi:10.1097/00006534-197905000-00005
  31. Fister J., 1980, Oral. Surg., 49, 105, 10.1016/0030-4220(80)90300-X · doi:10.1016/0030-4220(80)90300-x
  32. Freeman J. W, 1972, South Carolina Dent. J., 30, 10
  33. Giro C, 1974, Oral. Implantol., 4, 104
  34. Griss P., 1975, J. Biomed. Mater. Symp., 6, 177, 10.1002/jbm.820090421 · doi:10.1002/jbm.820090421
  35. Grundschober F., 1980, Long-term osseous anchorage of endosseous dental implants made of titanium and tantalum
  36. Hagert C.-G, 1975, Diss. Göteborg.
  37. Hille G. H, 1966, J. Materials, 1, 373
  38. Hobkirk J. A., 1977, J. Oral. Surg., 35, 968
  39. Homsy C. A., 1973, J. Am. Dent. Assoc., 86, 817, 10.14219/jada.archive.1973.0166 · doi:10.14219/jada.archive.1973.0166
  40. Hughes A. N., 1973, Injury, 4, 25, 10.1016/S0020-1383(72)80007-X · doi:10.1016/s0020-1383(72)80007-x
  41. Jacobs C. H., 1976, J. Biomech., 9, 343, 10.1016/0021-9290(76)90056-7 · doi:10.1016/0021-9290(76)90056-7
  42. Jacobs H. G, 1976, Implantologie und Zahnersatz
  43. Jacobs H. G, 1977, Dtsch. Zahnäntl Z., 36, 63
  44. Jacobs H. G, 1979, ZM Fortbildung, 5, 254
  45. Jacobs C. H, 1977, Proc. Bull Hosp. Joint Dis., 38, 4
  46. Jacobs R. L., 1972, Arch. Surg., 104, 687, 10.1001/archsurg.1972.04180050061014 · doi:10.1001/archsurg.1972.04180050061014
  47. Judet R., 1978, Clin. Orthop., 137, 76
  48. Juillerat D. A., 1977, Diss. Univ. Bern 1977.
  49. Karagianes M. T., 1976, J. Dent. Res., 55, 85, 10.1177/00220345760550013001 · doi:10.1177/00220345760550013001
  50. Klawitter J. J., 1974, Acta Orthop. Belg., 40, 755
  51. Krause W, 1977, Proc. Bull. Hosp. Joint. Dis., 38, 5
  52. Laing P. G., 1967, J. Biomed. Mater. Res., 1, 135, 10.1002/jbm.820010113 · doi:10.1002/jbm.820010113
  53. Ledermann Ph, 1979, Dtsch. Zahnärztl. Z., 34, 907
  54. Linder L., 1975, Injury, 6, 277, 10.1016/0020-1383(75)90174-6 · doi:10.1016/0020-1383(75)90174-6
  55. Linder L, 1976, Bone cement monomer. Thesis
  56. Linder L, 1980, Biocompatibility of orthopaedic implants, Vol. II
  57. Lindström J., 1981, Scand. J. Plast. Reconstr. Surg.
  58. Linkow L. I., 1973, Oral. Implantol., 3, 281
  59. Linkow L. I., 1970, Theories and techniques of oral implantology
  60. Lord G. A., 1979, Clin. Orthop., 141, 2
  61. McQuillian A. D., 1956, Metallurgy of the rarer metals. 4: Titanium
  62. Moss R. W, 1964, Oral. Surg., 17, 405, 10.1016/0030-4220(64)90515-8 · doi:10.1016/0030-4220(64)90515-8
  63. Muster D., 1978, Actualités Odonto-Stomat., 121, 109
  64. Nixon J, 1975, Oral. Implantol., 5, 370
  65. Pallan F. G, 1960, J. Oral. Surg., 18, 400
  66. Predecki P., 1972, J. Biomed. Mater. Res., 6, 401, 10.1002/jbm.820060507 · doi:10.1002/jbm.820060507
  67. Ring P. A, 1978, Clin. Orthop., 137, 87
  68. Ritter H., 1979, Acta Orthop, Traumat. Surg., 95, 89, 10.1007/BF00379175 · doi:10.1007/bf00379175
  69. Salzer M., 1979, Arch. Orthop. Traumat. Surg., 93, 169, 10.1007/BF00523668 · doi:10.1007/bf00523668
  70. Schatzker J. G., 1975, Clin. Orthop., 111, 257, 10.1097/00003086-197509000-00032 · doi:10.1097/00003086-197509000-00032
  71. Schroeder A., 1976, Schweiz Mschr. Zahnheilk., 86, 713
  72. Schroeder A., 1978, Schweiz. Mschr. Zahnheilk., 88, 1051
  73. Solar R. J., 1979, J. Biomed. Mater. Res., 12, 217, 10.1002/jbm.820130206 · doi:10.1002/jbm.820130206
  74. Southam J. C., 1970, Brit. J. Oral. Surg., 8, 211, 10.1016/S0007-117X(70)80082-8 · doi:10.1016/s0007-117x(70)80082-8
  75. Swanson A. B, 1973, Flexible implant resection arthroplasty in the hand and extremities
  76. Swanson A. B., 1977, The scientific basis of joint replacement
  77. Tjellström A., 1978, Acta Otolaryng. (Stockh.), 85, 33, 10.3109/00016487809121420 · doi:10.3109/00016487809121420
  78. Tjellström A., 1978, Acta Otolaryng. (Stockh.), 85, 232, 10.3109/00016487809111930 · doi:10.3109/00016487809111930
  79. Tjellström A., 1981, Laryngoscope
  80. Tjellström A., 1981, Am. J. Otol.
  81. Thompson H. C, 1958, J. Oral. Surg., 16, 22
  82. Uhthoff H. K, 1973, J. Bone Joint Surg., 55, 633, 10.1302/0301-620X.55B3.633 · doi:10.1302/0301-620x.55b3.633
  83. Weiss M. B, 1977, Quintess int., 10

Cited by

Items 101–106 of 106

Metadata

Authors
Albrektsson, T., Brånemark, P.-I., Hansson, H.-A., & Lindström, J.
Venue
Acta Orthopaedica Scandinavica
Published
1981-01
Volume
52
Issue
2
Pages
155-170
ISSN
0001-6470 (ISSN-L)
OpenAlex
W2151005356
Cited by
2,690
References
7
FWCI
32.18
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.