Low-Cost, 3-Dimension, Office-Based Inertial Sensors for Automated Tremor Assessment: Technical Development and Experimental Verification
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Background: Tremors are common clinical complaints among the elderly and non-specialist physicians frequently are challenged by the need to provide an accurate diagnosis of various tremor syndromes, particularly Parkinson's disease and essential tremor in their busy practices. Objective: We sought to develop an easy-to-use, mobile robust, accurate, and cost-effective instrument that can objectively quantify tremors. Method: The low-cost, 3-dimension, inertial sensors were developed for automated tremor assessment. The main sensor unit consists of a 3-axis accelerometer and a 3-axis gyroscope for the purpose of measuring the tilting angle relative to the gravity, linear acceleration, and angular velocity of the body segments affected by tremors. The transmitter consists of five main modules, including a microcontroller, power management module, sensor module, external memory interface module, and Bluetooth™ communication interface module, which connects to the sensors by a thin wire. The signal processing utilized fast Fourier transform analysis to include RMS angular rate, RMS angle, RMS rate, RMS velocity, peak frequency, peak frequency magnitude, and dispersion of frequency as variables. Result: The prototype was tested with a tremor simulator at programmable angular rates of 2-, 4-, and 8-Hz confirming its accuracy. Twenty subjects (10 PD and 10 age-matched ET patients) participated as part of the experimental verification to perform three tremor tasks, including rest, postural, and kinetic tremor according to the teaching videotape of the motor section of the UPDRS. The mean peak frequency was significantly lower in PD than ET patients at rest on the x- (p < 0.01) and z-axis (p < 0.01). In PD patients, the RMS angular rate, RMS angle, RMS rate, RMS velocity, and peak magnitude were all significantly higher than those values in ET patient at rest while the data was not significantly difference during postural and kinetic actions. ET patients had significantly higher peak frequency during postural action in the y-axis than PD patients (p < 0.05). Conclusion: The study provides the technical development of an accurate, inexpensive, and simple method to measure the kinematics of tremor in humans. Further studies are warranted to confirm the validity of each parameter and the diagnostic accuracy in each tremor syndrome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Consensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981
Salarian, A., Russmann, H., Wider, C., Burkhard, P. R., Vingerhoets, F. J. G., & Aminian, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886670 · Cited by 416
Wenning, G. K., Kiechl, S., Seppi, K., Müller, J., Högl, B., Saletu, M., Rungger, G., Gasperi, A., Willeit, J., & Poewe, W. (2005) · The Lancet Neurology · doi:10.1016/s1474-4422(05)70226-x · Cited by 302 · cited 1×
“Tremor is defined as a rhythmic oscillation of a body part and is one of the movement disorders frequently encountered by physicians working in many specialties and in general practice [1, 2].”
Clinical Applications of Sensors for Human Posture and Movement Analysis: A Review
Wong, W. Y., Wong, M. S., & Lo, K. H. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600983949 · Cited by 193 · cited 2×
“Therefore, the combination of a gyroscope with an accelerometer is particularly useful for measuring angular movements such as the pill-rolling tremor of PD [31].”
Differential diagnosis of common tremor syndromes
Bhidayasiri, R. (2005) · Postgraduate Medical Journal · doi:10.1136/pgmj.2005.032979 · Cited by 177
Self-citationDistinguishing essential tremor from Parkinson's disease: bedside tests and laboratory evaluations
Thenganatt, M. A., & Louis, E. D. (2012) · Expert Review of Neurotherapeutics · doi:10.1586/ern.12.49 · Cited by 155 · cited 1×
“However, their main purpose is not to help distinguish between the common forms of tremor, such as tremors in PD and ET, which is a frequent diagnostic problem in clinical practice [30].”
Neurological Tremor: Sensors, Signal Processing and Emerging Applications
Grimaldi, G., & Manto, M. (2010) · Sensors · doi:10.3390/s100201399 · Cited by 138 · cited 1×
“The idea of utilizing objective recordings to study various types of tremors is not new [13].”
Validation for tremor quantification of an electromagnetic tracking device
O'Suilleabhain, P. E., & Dewey, R. B. (2001) · Movement Disorders · doi:10.1002/mds.1064 · Cited by 53
Asymmetry of tremor intensity and frequency in parkinson's disease and essential tremor
Farkas, Z., Csillik, A., Szirmai, I., & Kamondi, A. (2006) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2005.07.008 · Cited by 44
Wharrad, H. J., & Jefferson, D. (2000) · Human Movement Science · doi:10.1016/s0167-9457(00)00017-8 · Cited by 19
Cited by
Wearable sensor-based objective assessment of motor symptoms in Parkinson’s disease
Ossig, C., Antonini, A., Buhmann, C., Classen, J., Csoti, I., Falkenburger, B., Schwarz, M., Winkler, J., & Storch, A. (2016) · Journal of Neural Transmission · doi:10.1007/s00702-015-1439-8 · Cited by 164
Surangsrirat, D., Thanawattano, C., Pongthornseri, R., Dumnin, S., Anan, C., & Bhidayasiri, R. (2016) · 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7592190 · Cited by 42
Self-citationJitkritsadakul, O., Thanawattano, C., Anan, C., & Bhidayasiri, R. (2015) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2015.08.1527 · Cited by 38
Self-citationThanawattano, C., Pongthornseri, R., Anan, C., Dumnin, S., & Bhidayasiri, R. (2015) · BioMedical Engineering OnLine · doi:10.1186/s12938-015-0098-1 · Cited by 35
Self-citation
Metadata
- Authors
- Bhidayasiri, R., Petchrutchatachart, S., Pongthornseri, R., Anan, C., Dumnin, S., & Thanawattano, C.
- Venue
- Journal of Parkinson’s Disease
- Publisher
- SAGE Publications
- Published
- 2014-05
- Volume
- 4
- Issue
- 2
- Pages
- 273-282
- ISSN
- 1877-7171 (ISSN-L)
- 1877-718X
- OpenAlex
- W1817415608
- Cited by
- 26
- References
- 10
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.