Pathological tremor management: Modelling, compensatory technology and evaluation
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
A great deal of effort has been devoted in the past decades in the generic area of tremor management. Specific topics of modelling for objective classification of pathological tremor out of kinematics and physiological data, compensatory technologies and evaluation rating tools are just a few examp les of application field. This paper introduces a comprehensive review of research work in this generic field during the last decades. In particular special focus has been put on the systems approach and thus a specific section on modelling has been included. Aspects related to experimental protocol and tremor pattern identification are reviewed in detail with the aim of drawing a practical guideline when compensatory technology has to be developed. The current status on ambulatory and non-ambulatory tremor reduction technologies is given in the section devoted to tremor management. Here compensatory technologies are classified according to the tremor isolation and the tremor reduction approaches. Eventually, we finish our discussion with those aspects related to tremor evaluation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“in fact, 65% of patients suffering from upper limb tremor report serious difficulties in performing their activities of daily living [2].”
From Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data (2010) · cites this paper as [2]
In the citing paper
“In particular, it has been clinically demonstrated that increase of damping and/or inertia in the upper limb leads to an effective tremor reduction [2,8].”
From Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data (2010) · cites this paper as [2]
In the citing paper
“Voluntary motions are typically considered to have a frequency spectra below 2 Hz [43, 44]”
From Controlling a motorized orthosis to follow elbow volitional movement: tests with individuals with pathological tremor (2019) · cites this paper as [44]
In the citing paper
“One of the basic premises of almost any tremor suppression approach, used also in this work, is that tremor frequencies occupy a different frequency range than most daily voluntary motions (Rocon and Belda-Lois, 2004).”
From Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression (2016) · cites this paper as Rocon and Belda-Lois, 2004
In the citing paper
“The transfer function associated with Figure 4 can be expressed as a second-order system similar to that provided in Pledgie et al. (2000), Rocon and Belda-Lois (2004), and Taheri et al. (2011), with the addition of a differentiator to obtain a velocity output.”
From Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression (2016) · cites this paper as Rocon and Belda-Lois (2004)
3 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Discrete-Time Signal Processing
Oppenheim, A. V., & Schafer, R. W. (1989) · Cited by 12,571
Deuschl, G., Raethjen, J., Lindemann, M., & Krack, P. (2001) · Muscle & Nerve · doi:10.1002/mus.1063 · Cited by 508
Bain, P. G., Findley, L. J., Atchison, P., Behari, M., Vidailhet, M., Gresty, M., Rothwell, J. C., Thompson, P. D., & Marsden, C. D. (1993) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.56.8.868 · Cited by 437
Lippold, O. C. J. (1970) · The Journal of Physiology · doi:10.1113/jphysiol.1970.sp009018 · Cited by 286
Handbook of Parkinson's Disease
(2013) · CRC Press eBooks · doi:10.1201/b14361 · Cited by 272
Tremor and other oscillations in neuromuscular systems
Stein, R. B., & Oĝuztöreli, M. N. (1976) · Biological Cybernetics · doi:10.1007/bf00365525 · Cited by 264 · cited 2×
“Based on the Lippold work, Stein and Oguztöreli [12] introduced a deterministic model concerning the properties of muscles and the sensory feedback pathways from muscles in order to evaluate the tremor sources.”
MethodAdaptive cancelling of physiological tremor for improved precision in microsurgery
Riviere, C. N., Rader, R. S., & Thakor, N. V. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686791 · Cited by 260 · cited 2×
“Riviere [31] computed the uncompensated and compensated error by subtracting the estimated voluntary motion from the uncompensated and compensated, relatively.”
MethodAtypical antipsychotics in the treatment of drug-induced psychosis in Parkinson's disease
Friedman, J. H., & Factor, S. A. (2000) · Movement Disorders · doi:10.1002/1531-8257(200003)15:2<309::aid-mds1016>3.0.co;2-p · Cited by 216
The rhythmical activity of groups of motor units in the voluntary contraction of muscle
Lippold, O. C. J., Redfearn, J. W. T., & Vučo, J. (1957) · The Journal of Physiology · doi:10.1113/jphysiol.1957.sp005828 · Cited by 169 · cited 6×
“Elble [18] carefully examined the relation between hand tremor and the 8– 12 Hz component of finger tremor, that is the range of frequency that received the most attention, largely because of the work of Lippold [9] and Halliday and Redfearn [7].”
BackgroundInfluentialEssential tremor frequency decreases with time
Elble, R. J. (2000) · Neurology · doi:10.1212/wnl.55.10.1547 · Cited by 166 · cited 8×
“08 Hz yearly, however, Elble [22] found that tremor frequency is a function of age but not of duration illness.”
BackgroundMethodInfluentialA teleoperated microsurgical robot and associated virtual environment for eye surgery
Hunter, I. W., Doukoglou, T. D., Lafontaine, S. R., Charette, P. G., Jones, L. A., Sagar, M. A., Mallinson, G. D., & Hunter, P. J. (1993) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.1993.2.4.265 · Cited by 164 · cited 1×
“More than 65% of the population with upper limb tremor present serious difficulties performing daily living activities [37].”
BackgroundTremor disorders. Diagnosis and management.
Anouti, A., & Koller, W. C. (1995) · PubMed Central · Cited by 135
Mechanistic components of normal hand tremor
Elble, R. J., & Randall, J. E. (1978) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(78)90106-2 · Cited by 134 · cited 1×
“Under these conditions the power to be dissipated results in 1.7 W.”
BackgroundInfluentialCaparros-Lefebvre, D., Blond, S., Vermersch, P., Pecheux, N., Guieu, J. D., & Petit, H. (1993) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.56.3.268 · Cited by 130 · cited 18×
“Gao used a non-dynamical quantity L/T, which is the ratio between the embedding delay time and the mean oscillation period, and concluded that it is a much more promising figure of merit in discriminating between essential and Parkinsonian tremors.”
BackgroundInfluentialPathological tremors: deterministic chaos or nonlinear stochastic oscillators?
Timmer, J., Häussler, S., Lauk, M., & Lücking, C.-H. (2000) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.166494 · Cited by 130
Cross-spectral analysis of physiological tremor and muscle activity
Timmer, J., Lauk, M., Pfleger, W., & Deuschl, G. (1998) · Biological Cybernetics · doi:10.1007/s004220050439 · Cited by 126 · cited 2×
“In our literature review we have only found estimations on the power for Essential tremor due to Kotovsky [43].”
BackgroundMethodInfluentialMechanical and neural feedback factors in postural hand tremor of normal subjects.
Stiles, R. N. (1980) · Journal of Neurophysiology · doi:10.1152/jn.1980.44.1.40 · Cited by 113 · cited 3×
“In addition, Stiles high pass filters the EMG signal at 8 Hz to reject all possible motion artifacts.”
BackgroundAmplitude changes in the 8–12, 20–25, and 40 Hz oscillations in finger tremor
Vaillancourt, D. E., & Newell, K. M. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00378-3 · Cited by 106
(1998) · PubMed · Cited by 101
Postural and resting tremor in the upper limb
Morrison, S., & Newell, K. M. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00302-8 · Cited by 92 · cited 4×
“In particular, Morrison [17] studies the”
InfluentialTremor suppression through impedance control
Pledgie, S., Barner, K. E., Agrawal, S. K., & Rahman, T. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.830949 · Cited by 85 · cited 2×
“Pledgie [39] developed a methodology that incorpo-”
MethodAdaptive Fourier modeling for quantification of tremor
Riviere, C. N., Reich, S. G., & Thakor, N. V. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02263-2 · Cited by 83
Dynamically responsive intervention for tremor suppression
Manto, M., Topping, M., Soede, M., Sanchez-Lacuesta, J., Harwin, W., Pons, J., Williams, J., Skaarup, S., & Normie, L. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213635 · Cited by 81 · cited 2×
“The DRIFTS project (EU QoL QLK6-CT2002-00536)was launched on April 2002 with the main objective of validating the concept of active suppression of pathological tremor through ambulatory orthotic devices [51].”
BackgroundSelf-citation(1987) · PubMed · Cited by 75
Using Time Domain Characteristics to Discriminate Physiologic and Parkinsonian Tremors
Edwards, R., & Beuter, A. (2000) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200001000-00009 · Cited by 74 · cited 1×
“In this particular case, the aim was determining inter and intra limb tremor correlation as well as determining involuntary compensatory control of tremor.”
Analyzing the dynamics of hand tremor time series
Gantert, C., Honerkamp, J., & Timmer, J. (1992) · Biological Cybernetics · doi:10.1007/bf00204112 · Cited by 74
Spectral analysis of tremor: understanding the results.
Gresty, M., & Buckwell, D. (1990) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.53.11.976 · Cited by 71 · cited 1×
“[20] that the variability observed in the considered pathological tremors should be interpreted as caused by frequency and/or amplitude modulated harmonic oscillators.”
BackgroundAction tremor during object manipulation in Parkinson's disease
Forssberg, H., Ingvarsson, P. E., Iwasaki, N., Johansson, R. S., & Gordon, A. M. (2000) · Movement Disorders · doi:10.1002/1531-8257(200003)15:2<244::aid-mds1007>3.0.co;2-h · Cited by 66 · cited 1×
“In particular, Forssberg [49] characterises the nature of the oscillations regarding Parkinson disease, studying the action tremor during object manipulation in Parkinson’s disease.”
Background(1995) · PubMed · Cited by 63
Optimal digital filtering for tremor suppression
Gonzalez, J. G., Heredia, E. A., Rahman, T., Barner, K. E., & Arce, G. R. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841338 · Cited by 56 · cited 4×
“A different approach is proposed by Gonzalez [3], based on a three-step approach, as illustrated in Fig.”
MethodInfluentialPower spectral analysis of finger acceleration tremor
Randall, J. E., & Stiles, R. N. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.2.357 · Cited by 51 · cited 1×
“In the sixties, different techniques were used to measure the amplitude and frequency of tremor [8,9], spectral analysis was performed with analog computer devices.”
MethodAisen, M. L., Holzer, M., Rosen, M., Dietz, M., & McDowell, F. (1991) · Archives of Neurology · doi:10.1001/archneur.1991.00530170077023 · Cited by 44 · cited 5×
“If success in reducing tremor is found, it must be weighed against side effects and the potential for addiction [3].”
BackgroundMethodInfluentialThree-dimensional measurement of essential tremor
Matsumoto, J. Y., Dodick, D. W., Stevens, L. N., Newman, R. C., Caskey, P. E., & Fjerstad, W. (1999) · Movement Disorders · doi:10.1002/1531-8257(199903)14:2<288::aid-mds1014>3.0.co;2-m · Cited by 34 · cited 1×
“In those cases in which tremor appears under voluntary muscle contraction, i.e. postural, kinetic tremors, the subject is usually committed to perform a tracking task [3,9].”
Background(1981) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 29
THE EFFECT OF MECHANICAL IMPEDANCE ON ABNORMAL INTENTION TREMOR
Adelstein, B. D., & Rosen, M. J. (1981) · Bioengineering · doi:10.1016/b978-0-08-027207-8.50047-3 · Cited by 28 · cited 1×
“poseful actions [29], what suggest that a loading or-”
BackgroundPathological tremors as diffusional processes
Gao, J., & Tung, W. (2002) · Biological Cybernetics · doi:10.1007/s00422-001-0296-8 · Cited by 28 · cited 1×
“Gao [ 24 ] used dynamical systems theory in order to discriminate between essential and Parkinsonian tremors and has shown that pathological tremors can be characterised as diffusional processes.”
MethodEvaluation of a controlled-energy-dissipation orthosis for tremor suppression
Arnold, A. S., Rosen, M. J., & Aisen, M. L. (1993) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(05)80001-x · Cited by 24 · cited 1×
“[30] note that muscle fatigue, carryover of attenuation effects after damping is removed and long term strengthening of muscles due to orthosis imposed exercise all require study.”
BackgroundA stochastic time series model for hand tremor.
Randall, J. E. (1973) · Journal of Applied Physiology · doi:10.1152/jappl.1973.34.3.390 · Cited by 24 · cited 6×
“In particular, Stiles [13] focuses on determining to what extent mechanical and neural factors are involved in the excitation of physiological tremor.”
BackgroundInfluentialThe many forms of tremor: Precise classification guides selection of therapy
Cooper, G. E., & Rodnitzky, R. L. (2000) · Postgraduate Medicine · doi:10.3810/pgm.2000.07.1157 · Cited by 17 · cited 3×
“The frequency band is independent of external loading both under additional viscous damping and isometric constrain.”
BackgroundMethodDavis, B. J., & O’Connell, J. (2000) · European Neurology · doi:10.1159/000008155 · Cited by 10
Filtering involuntary motion of people with tremor disability using optimal equalization
Gonzalez, J. G., Heredia, E. A., Rahman, T., Barner, K. E., & Arce, G. R. (2002) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.1995.538141 · Cited by 10 · cited 1×
“In addition to all tremor measures presented in Section 4, sometimes, tremor amplitude is directly estimated from the power spectral density of the acceleration signal.”
Background
Cited by
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349
Self-citationReal-Time Estimation of Pathological Tremor Parameters from Gyroscope Data
Gallego, J., Rocon, E., Roa, J. O., Moreno, J., & Pons, J. L. (2010) · Sensors · doi:10.3390/s100302129 · Cited by 107
“In particular, it has been clinically demonstrated that increase of damping and/or inertia in the upper limb leads to an effective tremor reduction [2,8].”
BackgroundSelf-citationEmpirical Mode Decomposition: a novel technique for the study of tremor time series
de Lima, E. R., Andrade, A. O., Pons, J. L., Kyberd, P., & Nasuto, S. J. (2006) · Medical and Biological Engineering and Computing · doi:10.1007/s11517-006-0065-x · Cited by 93
“Although the most common types of tremor have been subject of numerous studies, their mechanisms and origins are still unknown [16, 19, 25].”
BackgroundMethodInfluentialSelf-citationRehabilitation Robotics: a Wearable Exo-Skeleton for Tremor Assessment and Suppression
Rocon, E., Ruiz, A. F., Pons, J. L., Belda-Lois, J. M., & Sanchez-Lacuesta, J. J. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570451 · Cited by 87
“Basic electronics provide a band pass filter with a low cut-off frequency of 0.3 Hz and a higher cut-off frequency of 25 Hz. This frequency band was considered the most relevant to tremor applications after a thorough literature review, [ 13 ].”
MethodInfluentialSelf-citationA neuroprosthesis for tremor management through the control of muscle co-contraction
Gallego, J. Á., Rocon, E., Belda-Lois, J. M., & Pons, J. L. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-36 · Cited by 81
“According to some estimates, more than 65% of those who suffer from pathological tremor—referred to as tremor in the remainder of the paper—at the upper limb report serious difficulties when performing their activities of daily living (ADLs) [3].”
BackgroundSelf-citation
Metadata
- Authors
- Rocon, E., Belda-Lois, J. M., Sanchez-Lacuesta, J. J., & Pons, J. L.
- Affiliations
- Instituto de Automática Industrial, Madrid, Spain
- ORCID
- Pons, J.L.
- Venue
- Technology and Disability
- Publisher
- SAGE Publications
- Published
- 2004-07-19
- Volume
- 16
- Issue
- 1
- Pages
- 3-18
- ISSN
- 1055-4181 (ISSN-L)
- 1878-643X
- OpenAlex
- W1855262381
- Cited by
- 89
- References
- 40
- Citations by year
- 2025: 3 · 2024: 3 · 2023: 1 · 2022: 2 · 2021: 4 · 2020: 3 · 2019: 5 · 2018: 3 · 2017: 7 · 2016: 4 · 2014: 7 · 2013: 9 · 2012: 5
- FWCI
- 2.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Technology and Disability (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Keywords
- pathological tremor, tremor control, tremor classification, experimental protocol
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.