CoChat

Systematic review and individual patient data meta-analysis of diagnosis of heart failure, with modelling of implications of different diagnostic strategies in primary care

Open access

The DOI matches its Crossref record; 196 of the 197 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: To assess the accuracy in diagnosing heart failure of clinical features and potential primary care investigations, and to perform a decision analysis to test the impact of plausible diagnostic strategies on costs and diagnostic yield in the UK health-care setting. DATA SOURCES: MEDLINE and CINAHL were searched from inception to 7 July 2006. 'Grey literature' databases and conference proceedings were searched and authors of relevant studies contacted for data that could not be extracted from the published papers. REVIEW METHODS: A systematic review of the clinical evidence was carried out according to standard methods. Individual patient data (IPD) analysis was performed on nine studies, and a logistic regression model to predict heart failure was developed on one of the data sets and validated on the other data sets. Cost-effectiveness modelling was based on a decision tree that compared different plausible investigation strategies. RESULTS: Dyspnoea was the only symptom or sign with high sensitivity (89%), but it had poor specificity (51%). Clinical features with relatively high specificity included history of myocardial infarction (89%), orthopnoea (89%), oedema (72%), elevated jugular venous pressure (70%), cardiomegaly (85%), added heart sounds (99%), lung crepitations (81%) and hepatomegaly (97%). However, the sensitivity of these features was low, ranging from 11% (added heart sounds) to 53% (oedema). Electrocardiography (ECG), B-type natriuretic peptides (BNP) and N-terminal pro-B-type natriuretic peptides (NT-proBNP) all had high sensitivities (89%, 93% and 93% respectively). Chest X-ray was moderately specific (76-83%) but insensitive (67-68%). BNP was more accurate than ECG, with a relative diagnostic odds ratio of ECG/BNP of 0.32 (95% CI 0.12-0.87). There was no difference between the diagnostic accuracy of BNP and NT-proBNP. A model based upon simple clinical features and BNP derived from one data set was found to have good validity when applied to other data sets. A model substituting ECG for BNP was less predictive. From this a simple clinical rule was developed: in a patient presenting with symptoms such as breathlessness in whom heart failure is suspected, refer directly to echocardiography if the patient has a history of myocardial infarction or basal crepitations or is a male with ankle oedema; otherwise, carry out a BNP test and refer for echocardiography depending on the results of the test. On the basis of the cost-effectiveness analysis carried out, such a decision rule is likely to be considered cost-effective to the NHS in terms of cost per additional case detected. The cost-effectiveness analysis further suggested that, if likely benefit to the patient in terms of improved life expectancy is taken into account, the optimum strategy would be to refer all patients with symptoms suggestive of heart failure directly for echocardiography. CONCLUSIONS: The analysis suggests the need for important changes to the NICE recommendations. First, BNP (or NT-proBNP) should be recommended over ECG and, second, some patients should be referred straight for echocardiography without undergoing any preliminary investigation. Future work should include evaluation of the clinical rule described above in clinical practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3310/hta13320

Cites

196 of 196 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 2

  1. AJ. Should general practitioners use the electrocardiogram to select patients with suspected heart failure for echocardiography? Int J Cardiol 1997;62:31–6.
  2. X-ray, radionuclide ventriculography and right heart catheterization. Eur Heart J 1989;10:1017–28.

Cited by

See all 510

Metadata

Authors
Mant, J., Doust, J., Roalfe, A., Barton, P., Cowie, M., Glasziou, P., Mant, D., McManus, R., Holder, R., Deeks, J., Fletcher, K., Qume, M., Sohanpal, S., Sanders, S., & Hobbs, F.
Affiliations
  • University of Birmingham (GB)
  • Bond University (AU)
  • National Institutes of Health (US)
  • University of Oxford (GB)
Corresponding author
Mant, J
Venue
Health Technology Assessment
Published
2009-07
Volume
13
Issue
32
Pages
1-207, iii
ISSN
  • 1366-5278 (ISSN-L)
  • 2046-4924
OpenAlex
W2075669100
Cited by
498
References
197
Citations by year
2026: 14 · 2025: 22 · 2024: 18 · 2023: 34 · 2022: 26 · 2021: 29 · 2020: 32 · 2019: 34 · 2018: 28 · 2017: 35 · 2016: 41 · 2015: 36 · 2014: 36 · 2013: 31 · 2012: 38
FWCI
4.07
Type
journal article
Language
en
Open access
Locations
  • Health Technology Assessment (publishedVersion, other-oa)
  • PubMed (publishedVersion)
  • Bond University Research Portal (Bond University) (submittedVersion, other-oa)
  • e-publications@bond (Bond University) (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
Funders
Health Technology Assessment programme (05/06/01)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Failure Treatment and Management
  • Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
Keywords
heart failure diagnosis, diagnostic accuracy, dyspnea, brain natriuretic peptide, NT-proBNP, electrocardiogram, chest radiography, clinical prediction rules, cost-effectiveness, diagnostic approach, primary care, echocardiography, decision analysis, sensitivity and specificity, clinical features, edema, orthopnea, hepatomegaly
MeSH terms
Aged, Aged, 80 and over, Diagnosis, Differential, Female, Heart Failure, Heart Function Tests, Humans, Male, Middle Aged, Primary Health Care, State Medicine, Practice Guidelines as Topic, Natriuretic Peptide, Brain

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.