Advancing Regulatory Science With Computational Modeling for Medical Devices at the FDA's Office of Science and Engineering Laboratories
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Protecting and promoting public health is the mission of the U.S. Food and Drug Administration (FDA). FDA's Center for Devices and Radiological Health (CDRH), which regulates medical devices marketed in the U.S., envisions itself as the world's leader in medical device innovation and regulatory science-the development of new methods, standards, and approaches to assess the safety, efficacy, quality, and performance of medical devices. Traditionally, bench testing, animal studies, and clinical trials have been the main sources of evidence for getting medical devices on the market in the U.S. In recent years, however, computational modeling has become an increasingly powerful tool for evaluating medical devices, complementing bench, animal and clinical methods. Moreover, computational modeling methods are increasingly being used within software platforms, serving as clinical decision support tools, and are being embedded in medical devices. Because of its reach and huge potential, computational modeling has been identified as a priority by CDRH, and indeed by FDA's leadership. Therefore, the Office of Science and Engineering Laboratories (OSEL)-the research arm of CDRH-has committed significant resources to transforming computational modeling from a valuable scientific tool to a valuable regulatory tool, and developing mechanisms to rely more on digital evidence in place of other evidence. This article introduces the role of computational modeling for medical devices, describes OSEL's ongoing research, and overviews how evidence from computational modeling (i.e., digital evidence) has been used in regulatory submissions by industry to CDRH in recent years. It concludes by discussing the potential future role for computational modeling and digital evidence in medical devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697 · cited 1×
“The device uses deep learning algorithms (78) to analyze images of the eye taken with a retinal camera for detecting diabetic retinopathy.”
MethodArtificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Gosselin, M.-C., Neufeld, E., Moser, H., Huber, E., Farcito, S., Gerber, L., Jedensjö, M., Hilber, I., Gennaro, F. D., Lloyd, B., et al. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/5287 · Cited by 520 · cited 1×
“…mechanical activity in the heart (30); energy absorption in patients with deep-brain stimulators (31– 34), breast tissue expanders (35), in pregnant women and fetus during MRI exams (36); subthalamic nucleus (37), the breast (38), cancellous bone (39), the head (40) and whole body models (41, 42).”
BackgroundBadal, A., & Badano, A. (2009) · Medical Physics · doi:10.1118/1.3231824 · Cited by 358
Applicability Analysis of Validation Evidence for Biomedical Computational Models
Pathmanathan, P., Gray, R. A., Romero, V. J., & Morrison, T. M. (2017) · Journal of Verification Validation and Uncertainty Quantification · doi:10.1115/1.4037671 · Cited by 68
Self-citationValidation and Trustworthiness of Multiscale Models of Cardiac Electrophysiology
Pathmanathan, P., & Gray, R. A. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00106 · Cited by 63 · cited 1×
“…regulatory-grade evidence , i.e., sufficiently-credible digital evidence that can support regulatory applications (43–45); developing frameworks (46, 47) and metrics (48) for assessing the trustworthiness of models, and studying workflows for creating reproducible models 11 (49), and identifying…”
BackgroundSelf-citationHaddad, T., Himes, A., Thompson, L., Irony, T., Nair, R., & on Behalf of MDIC Computer Modeling and Simulation Working Group Participants (2017) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543406.2017.1300907 · Cited by 62
Hariharan, P., D’Souza, G. A., Horner, M., Morrison, T. M., Malinauskas, R. A., & Myers, M. R. (2017) · PLoS ONE · doi:10.1371/journal.pone.0178749 · Cited by 35 · cited 1×
“Computational models of anatomy or physiology include improved drug delivery in the cornea with ultrasound energy (24); physiological models of heart cells (25), renal circulation (26), hemodynamic responses to blood volume perturbations (27), left bundle branch block (28), gas dynamics in the…”
BackgroundSelf-citationDevelopment of a flow evolution network model for the stress-strain behavior of poly(L-lactide)
Dreher, M. L., Nagaraja, S., Bergstrom, J., & Hayman, D. (2017) · Journal of Biomechanical Engineering · doi:10.1115/1.4037071 · Cited by 12
Cited by
The ‘Digital Twin’ to enable the vision of precision cardiology
Corral-Acero, J., Margara, F., Marciniak, M., Rodero, C., Loncaric, F., Feng, Y., Gilbert, A., Fernandes, J. F., Bukhari, H. A., Wajdan, A., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehaa159 · Cited by 932
Self-citationCoorey, G., Figtree, G. A., Fletcher, D. F., Snelson, V. J., Vernon, S. T., Winlaw, D., Grieve, S. M., McEwan, A., Yang, J. Y. H., Qian, P., et al. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00640-7 · Cited by 384
Innovations in Genomics and Big Data Analytics for Personalized Medicine and Health Care: A Review
Hassan, M., Awan, F. M., Naz, A., deAndrés-Galiana, E. J., Alvarez, O., Cernea, A., Fernández-Brillet, L., Fernández-Martínez, J. L., & Kloczkowski, A. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23094645 · Cited by 317
“(EMA) [34,35].”
BackgroundDerraz, B., Breda, G., Kaempf, C., Baenke, F., Cotte, F., Reiche, K., Köhl, U., Kather, J. N., Eskenazy, D., & Gilbert, S. (2024) · npj Precision Oncology · doi:10.1038/s41698-024-00517-w · Cited by 94
Morrison, T. M., Hariharan, P., Funkhouser, C. M., Afshari, P., Goodin, M., & Horner, M. (2019) · ASAIO Journal · doi:10.1097/mat.0000000000000996 · Cited by 68
Self-citation
Metadata
- Authors
- Morrison, T. M., Pathmanathan, P., Adwan, M., & Margerrison, E.
- Venue
- Frontiers in Medicine
- Publisher
- Frontiers Media SA
- Published
- 2018-09-25
- Volume
- 5
- Pages
- 241-241
- ISSN
- 2296-858X (ISSN-L)
- OpenAlex
- W2894128844
- Cited by
- 186
- References
- 9
- FWCI
- 16.87
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.