Nanowire electrodes for high-density stimulation and measurement of neural circuits
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Brain-machine interfaces (BMIs) that can precisely monitor and control neural activity will likely require new hardware with improved resolution and specificity. New nanofabricated electrodes with feature sizes and densities comparable to neural circuits may lead to such improvements. In this perspective, we review the recent development of vertical nanowire (NW) electrodes that could provide highly parallel single-cell recording and stimulation for future BMIs. We compare the advantages of these devices and discuss some of the technical challenges that must be overcome for this technology to become a platform for next-generation closed-loop BMIs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 5×
“For instance, contemporary extracellular electrodes have array sizes approaching one hundred electrodes and can simultaneously measure the activity of dozens of individual neurons (Hochberg et al., 2006; Donoghue et al., 2007; Du et al., 2011).”
BackgroundInfluentialWilliams, R. W., & Herrup, K. (1988) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.11.030188.002231 · Cited by 585 · cited 2×
“In fact, a single square millimeter of brain tissue contains approximately one million neurons (Williams and Herrup, 1988).”
BackgroundSimeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
Single-Unit Stability Using Chronically Implanted Multielectrode Arrays
Dickey, A. S., Suminski, A., Amit, Y., & Hatsopoulos, N. G. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90920.2008 · Cited by 234
Multiplexed, High Density Electrophysiology with Nanofabricated Neural Probes
Du, J., Blanche, T. J., Harrison, R. R., Lester, H. A., & Masmanidis, S. C. (2011) · PLoS ONE · doi:10.1371/journal.pone.0026204 · Cited by 231 · cited 4×
“Supporting this idea are reports that vertical NWs can pin neurons in place and inhibit them from migrating away from NW electrodes (Xie et al., 2010).”
BackgroundInfluentialIntegrated wireless neural interface based on the Utah electrode array
Kim, S., Bhandari, R., Klein, M., Negi, S., Rieth, L., Tathireddy, P., Toepper, M., Oppermann, H., & Solzbacher, F. (2009) · Biomedical Microdevices · doi:10.1007/s10544-008-9251-y · Cited by 165 · cited 1×
“Yet another advantage of silicon-based electrodes is that they can be readily coupled to back-side CMOS electronics using bonding or other post-processing methods such as those used for extracellular electrodes (Kim et al., 2009).”
MethodBourne, S. K., Eckhardt, C. A., Sheth, S. A., & Eskandar, E. N. (2012) · Frontiers in Integrative Neuroscience · doi:10.3389/fnint.2012.00029 · Cited by 146 · cited 1×
“BMIs can also be used to treat neurological disorders such as Parkinson’s disease (Volkmann, 2004), obsessive compulsive disorder (Bourne et al., 2012), and depression (Howland et al., 2011) by applying voltage or current pulses to specific regions deep within the brain—a treatment known as deep…”
BackgroundMacroporous nanowire nanoelectronic scaffolds for synthetic tissues
Tian, B., Liu, J., Dvir, T., Jin, L., Tsui, J. H., Qing, Q., Suo, Z., Langer, R., Kohane, D. S., & Lieber, C. M. (2012) · Nature Materials · doi:10.1038/nmat3404 · Cited by 20 · cited 1×
“Recently Tian et al. have taken steps in this direction by embedding NW FETs in a flexible polymer matrix and releasing them from the rigid substrate (Tian et al., 2012).”
Cited by
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
“This is achieved by 3D structured electrodes such as silicon nanowires (Robinson et al., 2013) and Au mushrooms (Hai et al., 2009) penetrating the cell membrane.”
Wireless and battery-free technologies for neuroengineering
Won, S. M., Cai, L., Gutruf, P., & Rogers, J. A. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00683-3 · Cited by 360
CMOS nanoelectrode array for all-electrical intracellular electrophysiological imaging
Abbott, J., Ye, T., Qin, L., Jorgolli, M., Gertner, R. S., Ham, D., & Park, H. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.3 · Cited by 266
Self-citationAn Implantable 455-Active-Electrode 52-Channel CMOS Neural Probe
Lopez, C. M., Andrei, A., Mitra, S., Welkenhuysen, M., Eberle, W., Bartic, C., Puers, R., Yazicioglu, R. F., & Gielen, G. G. E. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284347 · Cited by 264
High‐Aspect‐Ratio Nanostructured Surfaces as Biological Metamaterials
Higgins, S. G., Becce, M., Belessiotis‐Richards, A., Seong, H., Sero, J. E., & Stevens, M. M. (2020) · Advanced Materials · doi:10.1002/adma.201903862 · Cited by 256
Lin, Z. C., Xie, C., Osakada, Y., Cui, Y., & Cui, B. (2014) · Nature Communications · doi:10.1038/ncomms4206 · Cited by 249
“Compared with patch clamp, the advantages of nanotube electrodes for intracellular recording include easy scalability for simultaneous measurement of many cells, minimal invasiveness of the cell viability, and longer-term monitoring of the same cell 9, 11 .”
Neural Dust: An Ultrasonic, Low Power Solution for Chronic Brain-Machine Interfaces
Seo, D., Carmena, J. M., Rabaey, J. M., Alon, E., & Maharbiz, M. M. (2013) · arXiv · doi:10.48550/arxiv.1307.2196 · Cited by 172
Nanowire FET Based Neural Element for Robotic Tactile Sensing Skin
Taube Navaraj, W., García Núñez, C., Shakthivel, D., Vinciguerra, V., Labeau, F., Gregory, D. H., & Dahiya, R. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00501 · Cited by 127
“…to the capacitance between the individual gate and the floating gate and determines the weighing factor wi. VGwi corresponds to the voltage at each gate, VOffset arises from any non-ideal charges such as fixed-oxide or interface trap charges (Shashank et al., 2011; Robinson et al., 2013).”
BackgroundMethodInfluential
Metadata
- Authors
- Robinson, J. T., Jorgolli, M., & Park, H.
- Venue
- Frontiers in Neural Circuits
- Publisher
- Frontiers Media SA
- Published
- 2013
- Volume
- 7
- Pages
- 38-38
- ISSN
- 1662-5110 (ISSN-L)
- OpenAlex
- W2125569990
- Cited by
- 60
- References
- 8
- FWCI
- 3.06
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.