The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Long-term asynchronous decoding of arm motion using electrocorticographic signals in monkey
Open accessAbstract
Brain-machine interfaces (BMIs) employ the electrical activity generated by cortical neurons directly for controlling external devices and have been conceived as a means for restoring human cognitive or sensory-motor functions. The dominant approach in BMI research has been to decode motor variables based on single-unit activity (SUA). Unfortunately, this approach suffers from poor long-term stability and daily recalibration is normally required to maintain reliable performance. A possible alternative is BMIs based on electrocorticograms (ECoGs), which measure population activity and may provide more durable and stable recording. However, the level of long-term stability that ECoG-based decoding can offer remains unclear. Here we propose a novel ECoG-based decoding paradigm and show that we have successfully decoded hand positions and arm joint angles during an asynchronous food-reaching task in monkeys when explicit cues prompting the onset of movement were not required. Performance using our ECoG-based decoder was comparable to existing SUA-based systems while evincing far superior stability and durability. In addition, the same decoder could be used for months without any drift in accuracy or recalibration. These results were achieved by incorporating the spatio-spectro-temporal integration of activity across multiple cortical areas to compensate for the lower fidelity of ECoG signals. These results show the feasibility of high-performance, chronic and versatile ECoG-based neuroprosthetic devices for real-life applications. This new method provides a stable platform for investigating cortical correlates for understanding motor control, sensory perception, and high-level cognitive processes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two new Later Stone Age sites from the Final Pleistocene in the Falémé Valley, eastern Senegal
Ndiaye, M., Lespez, L., Tribolo, C., Rassé, M., Hadjas, I., Davidoux, S., Huysecom, É., & Douze, K. (2024) · Monash University Research Portal (Monash University) · doi:10.3929/ethz-b-000667478 · Cited by 23,868
Partial least-squares regression: a tutorial
Geladi, P., & Kowalski, B. R. (1986) · Analytica Chimica Acta · doi:10.1016/0003-2670(86)80028-9 · Cited by 6,992
Wold, S., Ruhe, A., Wold, H., & Dunn, III (1984) · SIAM Journal on Scientific and Statistical Computing · doi:10.1137/0905052 · Cited by 2,529
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Real-time prediction of hand trajectory by ensembles of cortical neurons in primates
Wessberg, J., Stambaugh, C. R., Kralik, J. D., Beck, P. D., Laubach, M., Chapin, J. K., Kim, J., Biggs, S. J., Srinivasan, M. A., & Nicolelis, M. A. L. (2000) · Nature · doi:10.1038/35042582 · Cited by 1,487
A brain–computer interface using electrocorticographic signals in humans
Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/001 · Cited by 1,188
Complex Movements Evoked by Microstimulation of Precentral Cortex
Graziano, M. S. A., Taylor, C. S. R., & Moore, T. (2002) · Neuron · doi:10.1016/s0896-6273(02)00698-0 · Cited by 921
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Connecting cortex to machines: recent advances in brain interfaces
Donoghue, J. P. (2002) · Nature Neuroscience · doi:10.1038/nn947 · Cited by 721
Brain–machine interfaces to restore motor function and probe neural circuits
Nicolelis, M. A. L. (2003) · Nature Reviews Neuroscience · doi:10.1038/nrn1105 · Cited by 589
Decoding two-dimensional movement trajectories using electrocorticographic signals in humans
Schalk, G., Kubánek, J., Miller, K. J., Anderson, N. R., Leuthardt, E. C., Ojemann, J. G., Limbrick, D., Moran, D., Gerhardt, L. A., & Wolpaw, J. R. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/012 · Cited by 527
NEURAL SELECTION AND CONTROL OF VISUALLY GUIDED EYE MOVEMENTS
Schall, J. D., & Thompson, K. G. (1999) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.22.1.241 · Cited by 489
Two-dimensional movement control using electrocorticographic signals in humans
Schalk, G., Miller, K. J., Anderson, N. R., Wilson, J. A., Smyth, M. D., Ojemann, J. G., Moran, D. W., Wolpaw, J. R., & Leuthardt, E. C. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/008 · Cited by 482
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 475
Moving in Three-Dimensional Space: Frames of Reference, Vectors, and Coordinate Systems
Soechting, J. F., & Flanders, M. (1992) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.15.030192.001123 · Cited by 426
Hand Movement Direction Decoded from MEG and EEG
Waldert, S., Preissl, H., Demandt, E., Braun, C., Birbaumer, N., Aertsen, A., & Mehring, C. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.5171-07.2008 · Cited by 415
Cortical control of reaching movements
Kalaska, J. F., Scott, S. H., Cisek, P., & Sergio, L. E. (1997) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(97)80146-8 · Cited by 390
Mitz, A., Godschalk, M., & Wise, S. (1991) · The Journal of Neuroscience · doi:10.1523/jneurosci.11-06-01855.1991 · Cited by 385
The Science of Neural Interface Systems
Hatsopoulos, N. G., & Donoghue, J. P. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135241 · Cited by 377
Spatial spectra of scalp EEG and EMG from awake humans
Freeman, W. J., Holmes, M. D., Burke, B. C., & Vanhatalo, S. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00045-2 · Cited by 370
The Cortical Control of Movement Revisited
Graziano, M. S. A., Taylor, C. S. R., Moore, T., & Cooke, D. F. (2002) · Neuron · doi:10.1016/s0896-6273(02)01003-6 · Cited by 363
Prediction of arm movement trajectories from ECoG-recordings in humans
Pistohl, T., Ball, T., Schulze-Bonhage, A., Aertsen, A., & Mehring, C. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.10.001 · Cited by 331
Moving effortlessly in three dimensions: does Donders' law apply to arm movement?
Soechting, J., Buneo, C., Herrmann, U., & Flanders, M. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-09-06271.1995 · Cited by 318
Rickert, J., de Oliveira, S. C., Vaadia, E., Aertsen, A., Rotter, S., & Mehring, C. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.0816-05.2005 · Cited by 316
Advanced Neurotechnologies for Chronic Neural Interfaces: New Horizons and Clinical Opportunities
Kipke, D. R., Shain, W., Buzsáki, G., Fetz, E., Henderson, J. M., Hetke, J. F., & Schalk, G. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.3879-08.2008 · Cited by 286
Decoding flexion of individual fingers using electrocorticographic signals in humans
Kubánek, J., Miller, K. J., Ojemann, J. G., Wolpaw, J. R., & Schalk, G. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/6/066001 · Cited by 285
Movement related activity in the high gamma range of the human EEG
Ball, T., Demandt, E., Mutschler, I., Neitzel, E., Mehring, C., Vogt, K., Aertsen, A., & Schulze-Bonhage, A. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.02.032 · Cited by 274
Rhythmicity, synchronization and binding in human and primate motor systems
Farmer, S. F. (1998) · The Journal of Physiology · doi:10.1111/j.1469-7793.1998.003bo.x · Cited by 273
Cortical ensemble activity increasingly predicts behaviour outcomes during learning of a motor task
Laubach, M., Wessberg, J., & Nicolelis, M. A. L. (2000) · Nature · doi:10.1038/35014604 · Cited by 272
Electrocorticography-based brain computer Interface-the seattle experience
Leuthardt, E. C., Miller, K. J., Schalk, G., Rao, R. P. N., & Ojemann, J. G. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875536 · Cited by 245
A direct brain interface based on event-related potentials
Levine, S. P., Huggins, J. E., BeMent, S. L., Kushwaha, R. K., Schuh, L. A., Rohde, M. M., Passaro, E. A., Ross, D. A., Elisevich, K. V., & Smith, B. J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847809 · Cited by 197
Scott, S. H., & Kalaska, J. F. (1995) · Journal of Neurophysiology · doi:10.1152/jn.1995.73.6.2563 · Cited by 189
Decoding of Temporal Intervals From Cortical Ensemble Activity
Lebedev, M. A., O'Doherty, J. E., & Nicolelis, M. A. L. (2008) · Journal of Neurophysiology · doi:10.1152/jn.00734.2007 · Cited by 178
Brain–machine interfaces: computational demands and clinical needs meet basic neuroscience
Mussa-Ivaldi, F. (2003) · Trends in Neurosciences · doi:10.1016/s0166-2236(03)00121-8 · Cited by 175
Single-Neuron Stability during Repeated Reaching in Macaque Premotor Cortex
Chestek, C. A., Batista, A. P., Santhanam, G., Yu, B. M., Afshar, A., Cunningham, J. P., Gilja, V., Ryu, S. I., Churchland, M. M., & Shenoy, K. V. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.0959-07.2007 · Cited by 174
Differential representation of arm movement direction in relation to cortical anatomy and function
Ball, T., Schulze‐Bonhage, A., Aertsen, A., & Mehring, C. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/1/016006 · Cited by 139
The Development of Brain-Machine Interface Neuroprosthetic Devices
Patil, P. G., & Turner, D. A. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.11.002 · Cited by 120
Mehring, C., Nawrot, M. P., de Oliveira, S. C., Vaadia, E., Schulze‐Bonhage, A., Aertsen, A., & Ball, T. (2004) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2005.09.016 · Cited by 102
Extraction and localization of mesoscopic motor control signals for human ECoG neuroprosthetics
Sanchez, J. C., Gunduz, A., Carney, P. R., & Príncipe, J. C. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.04.019 · Cited by 100
Margalit, E., Weiland, J. D., Clatterbuck, R. E., Fujii, G. Y., Maia, M., Tameesh, M., Torres, G. F., D’Anna, S. A., Desai, S., Piyathaisere, D. V., et al. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00345-x · Cited by 96
Loeb, G. E., Walker, A. E., Uematsu, S., & Konigsmark, B. W. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110206 · Cited by 95
Tissue response to potential neuroprosthetic materials implanted subdurally
Yuen, T. G. H., Agnew, W. F., & Bullara, L. A. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90103-7 · Cited by 91
Brain–computer interfaces: an overview of the hardware to record neural signals from the cortex
Stieglitz, T., Rubehn, B., Henle, C., Kisban, S., Herwik, S., Ruther, P., & Schüettler, M. (2009) · Progress in brain research · doi:10.1016/s0079-6123(09)17521-0 · Cited by 72
Chan, S. S., & Moran, D. W. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/010 · Cited by 52
Evaluation of Electrode Array Material for Neural Prostheses
Bullara, L. A., Agnew, W. F., Yuen, T. G. H., Jacques, S., & Pudenz, R. H. (1979) · Neurosurgery · doi:10.1227/00006123-197912000-00006 · Cited by 45
Márquez-Chin, C., Popović, M. R., Thrasher, T. A., Cameron, T., Lozano, A. M., & Chen, R. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/014 · Cited by 29
Cited by
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
Viventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136
Brain-Computer Interfaces in Medicine
Shih, J. J., Krusienski, D. J., & Wolpaw, J. R. (2012) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2011.12.008 · Cited by 724
Promises and limitations of human intracranial electroencephalography
Parvizi, J., & Kastner, S. (2018) · Nature Neuroscience · doi:10.1038/s41593-018-0108-2 · Cited by 631
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Metadata
- Authors
- Chao
- Venue
- Frontiers in Neuroengineering
- Publisher
- Frontiers Media SA
- Published
- 2010
- Volume
- 3
- Pages
- 3-3
- ISSN
- 1662-6443 (ISSN-L)
- OpenAlex
- W1985741088
- Cited by
- 341
- References
- 48
- FWCI
- 18.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.