Comparison of Dry and Gel Based Electrodes for P300 Brain–Computer Interfaces
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Most brain-computer interfaces (BCIs) rely on one of three types of signals in the electroencephalogram (EEG): P300s, steady-state visually evoked potentials, and event-related desynchronization. EEG is typically recorded non-invasively with electrodes mounted on the human scalp using conductive electrode gel for optimal impedance and data quality. The use of electrode gel entails serious problems that are especially pronounced in real-world settings when experts are not available. Some recent work has introduced dry electrode systems that do not require gel, but often introduce new problems such as comfort and signal quality. The principal goal of this study was to assess a new dry electrode BCI system in a very common task: spelling with a P300 BCI. A total of 23 subjects used a P300 BCI to spell the word "LUCAS" while receiving real-time, closed-loop feedback. The dry system yielded classification accuracies that were similar to those obtained with gel systems. All subjects completed a questionnaire after data recording, and all subjects stated that the dry system was not uncomfortable. This is the first field validation of a dry electrode P300 BCI system, and paves the way for new research and development with EEG recording systems that are much more practical and convenient in field settings than conventional systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 4×
“Most P300 BCIs allow users to choose one target from several options, such as letters or numbers presented on a monitor (Farwell and Donchin, 1988; Townsend et al., 2010; Brunner et al., 2011).”
BackgroundResultInfluentialA spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577 · cited 1×
“For example, BCIs that rely on slow cortical potential changes (Birbaumer et al., 1999) might be more sensitive to signal drift below 3 Hz.”
BackgroundFrequency recognition based on canonical correlation analysis for SSVEP-based BCIs
Lin, Z., Zhang, C., Wu, W., & Gao, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889197 · Cited by 867
A comparison of classification techniques for the P300 Speller
Krusienski, D. J., Sellers, E. W., Cabestaing, F., Bayoudh, S., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/007 · Cited by 762 · cited 2×
“ORIGINAL RESEARCH ARTICLE published: 07 May 2012 doi: 10.3389/fnins.2012.00060 Comparison of dry and gel based electrodes for P300 brain–computer interfaces”
BackgroundMethodInfluentialToward enhanced p300 speller performance
Krusienski, D. J., Sellers, E. W., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.07.017 · Cited by 749 · cited 1×
“As with the Grozea et al. (2011) article, the additional spatial information available from a broader montage would have improved performance (e.g., Krusienski et al., 2006, 2008).”
BackgroundHow many people are able to control a P300-based brain-computer interface (BCI)?
Guger, C., Daban, S., Sellers, E., Holzner, C., Krausz, G., Carabalona, R., Gramatica, F., & Edlinger, G. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.06.045 · Cited by 652 · cited 6×
“One column presents the results with dry electrodes, and another column summarizes results from a large group study with gel electrodes (N = 81; Guger et al., 2009).”
BackgroundMethodInfluentialSelf-citationTownsend, G., LaPallo, B. K., Boulay, C. B., Krusienski, D. J., Frye, G. E., Hauser, C. K., Schwartz, N. E., Vaughan, T. M., Wolpaw, J. R., & Sellers, E. W. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.030 · Cited by 570
Multiple Channel Detection of Steady-State Visual Evoked Potentials for Brain-Computer Interfaces
Friman, O., Volosyak, I., & Graser, A. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889160 · Cited by 541 · cited 2×
“…McFarland et al., 2010; Vidaurre et al., 2011); Attention to oscillating visual stimuli, which produces steadystate visual evoked potentials (SSVEP; Friman et al., 2007; Lin et al., 2007; Ortner et al., 2011; Allison et al., 2012); Attention to transient stimuli, which produces the P300…”
BackgroundHow many people are able to operate an EEG-based brain-computer interface (BCI)?
Guger, C., Edlinger, G., Harkam, W., Niedermayer, I., & Pfurtscheller, G. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814481 · Cited by 526 · cited 2×
“…are associated with different types of brain activity (Wolpaw et al., 2002): Imagined movement, which produces event-related desynchronization (ERD; Guger et al., 2003; Pfurtscheller et al., 2006; Neuper et al., 2009; McFarland et al., 2010; Vidaurre et al., 2011); Attention to oscillating visual…”
BackgroundSelf-citation
Cited by
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
P300 brain computer interface: current challenges and emerging trends
Fazel-Rezai, R., Allison, B. Z., Guger, C., Sellers, E. W., Kleih, S. C., & Kübler, A. (2012) · Frontiers in Neuroengineering · doi:10.3389/fneng.2012.00014 · Cited by 359
Self-citationEEG-based brain–computer interfaces
McFarland, D. J., & Wolpaw, J. R. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.11.004 · Cited by 283
Brain-Computer Interface: Advancement and Challenges
Mridha, M. F., Das, S. C., Kabir, M. M., Lima, A. A., Islam, M. R., & Watanobe, Y. (2021) · Sensors · doi:10.3390/s21175746 · Cited by 263
Usability of four commercially-oriented EEG systems
David Hairston, W., Whitaker, K. W., Ries, A. J., Vettel, J. M., Cortney Bradford, J., Kerick, S. E., & McDowell, K. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/4/046018 · Cited by 215
“Examples include advocating the use of ‘active’ sensors to maximize the SNR, use of dry, gel-free [18–20] or non-contact sensors [21, 22], or simply comparing the signal quality of a whole new system [23–25].”
BackgroundLi, G., Wang, S., & Duan, Y. Y. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.08.155 · Cited by 203
Kam, J. W. Y., Griffin, S., Shen, A., Patel, S., Hinrichs, H., Heinze, H.-J., Deouell, L. Y., & Knight, R. T. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.012 · Cited by 188
“Several of the commercially available dry EEG systems used sensors comprised of metal pins (Guger et al., 2012; K€athner et al., 2017; Lo et al., 2016; Pinho et al., 2017; Toyama et al., 2012).”
How Many People Could Use an SSVEP BCI?
Guger, C., Allison, B. Z., Großwindhager, B., Prückl, R., Hintermüller, C., Kapeller, C., Bruckner, M., Krausz, G., & Edlinger, G. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00169 · Cited by 176
Self-citationHolz, E. M., Botrel, L., Kaufmann, T., & Kübler, A. (2015) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.03.035 · Cited by 171
Independent home use of a brain-computer interface by people with amyotrophic lateral sclerosis
Wolpaw, J. R., Bedlack, R. S., Reda, D. J., Ringer, R. J., Banks, P. G., Vaughan, T. M., Heckman, S. M., McCane, L. M., Carmack, C. S., Winden, S., et al. (2018) · Neurology · doi:10.1212/wnl.0000000000005812 · Cited by 170
Decoding Covert Speech From EEG-A Comprehensive Review
Panachakel, J. T., & Ramakrishnan, A. G. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.642251 · Cited by 156
“• Recording EEG for longer duration is challenging since the conductive gel or the saline solution applied for reducing the electrode impedance dries up over time, thus increasing the electrode impedance (Guger et al., 2012; Xu et al., 2018a).”
BackgroundNovel semi-dry electrodes for brain–computer interface applications
Wang, F., Li, G., Chen, J., Duan, Y., & Zhang, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046021 · Cited by 77
Li, J., & Wang, Q. (2022) · Information Fusion · doi:10.1016/j.inffus.2021.10.018 · Cited by 77
Benchmarking Brain-Computer Interfaces Outside the Laboratory: The Cybathlon 2016
Novak, D., Sigrist, R., Gerig, N. J., Wyss, D., Bauer, R., Götz, U., & Riener, R. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00756 · Cited by 41
“As long as this rule was met, we permitted both wired and wireless electrodes, and placed no restrictions on the use of gel—gel-based, water-based (Volosyak et al., 2010) and dry electrodes (Guger et al., 2012) were all acceptable.”
BackgroundQuantitative EEG for Brain–Computer Interfaces
(2014) · EEG/ERP Analysis · doi:10.1201/b17605-11 · Cited by 9
Metadata
- Authors
- Guger, C., Krausz, G., Allison, B. Z., & Edlinger, G.
- Venue
- Frontiers in Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2012
- Volume
- 6
- Pages
- 60-60
- ISSN
- 1662-453X (ISSN-L)
- 1662-4548
- OpenAlex
- W1987554349
- Cited by
- 190
- References
- 42
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.