Quantitative multi-parameter mapping of R1, PD*, MT, and R2* at 3T: a multi-center validation
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Multi-center studies using magnetic resonance imaging facilitate studying small effect sizes, global population variance and rare diseases. The reliability and sensitivity of these multi-center studies crucially depend on the comparability of the data generated at different sites and time points. The level of inter-site comparability is still controversial for conventional anatomical T1-weighted MRI data. Quantitative multi-parameter mapping (MPM) was designed to provide MR parameter measures that are comparable across sites and time points, i.e., 1 mm high-resolution maps of the longitudinal relaxation rate (R1 = 1/T1), effective proton density (PD(*)), magnetization transfer saturation (MT) and effective transverse relaxation rate (R2(*) = 1/T2(*)). MPM was validated at 3T for use in multi-center studies by scanning five volunteers at three different sites. We determined the inter-site bias, inter-site and intra-site coefficient of variation (CoV) for typical morphometric measures [i.e., gray matter (GM) probability maps used in voxel-based morphometry] and the four quantitative parameters. The inter-site bias and CoV were smaller than 3.1 and 8%, respectively, except for the inter-site CoV of R2(*) (<20%). The GM probability maps based on the MT parameter maps had a 14% higher inter-site reproducibility than maps based on conventional T1-weighted images. The low inter-site bias and variance in the parameters and derived GM probability maps confirm the high comparability of the quantitative maps across sites and time points. The reliability, short acquisition time, high resolution and the detailed insights into the brain microstructure provided by MPM makes it an efficient tool for multi-center imaging studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A fast diffeomorphic image registration algorithm
Ashburner, J. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.07.007 · Cited by 8,122
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507 · cited 5×
“UNICORT is based on the new unified segmentation approach implemented in SPM8 that combines image registration, tissue classification, and multiplicative bias correction in a single generative model and optimizes its log-likelihood objective function (Ashburner and Friston, 2005).”
InfluentialSENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Three‐dimensional magnetization‐prepared rapid gradient‐echo imaging (3D MP RAGE)
Mugler, J. P., & Brookeman, J. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910150117 · Cited by 1,265
Jovicich, J., Czanner, S., Greve, D., Haley, E., van der Kouwe, A., Gollub, R., Kennedy, D., Schmitt, F., Brown, G., MacFall, J., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.09.046 · Cited by 1,265
Automatic classification of MR scans in Alzheimer’s disease.
Kloppel, S., Stonnington, C. M., Chu, C., Draganski, B., Scahill, R. I., Rohrer, J. D., Fox, N. C., Jack, C. R., Ashburner, J., & Frackowiak, R. S. J. (2008) · Brain · doi:10.1093/brain/awm319 · Cited by 1,170
Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo
Rooney, W. D., Johnson, G., Li, X., Cohen, E. R., Kim, S., Ugurbil, K., & Springer, C. S. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21122 · Cited by 652
Deichmann, R., Schwarzbauer, C., & Turner, R. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.09.062 · Cited by 391
32‐channel 3 Tesla receive‐only phased‐array head coil with soccer‐ball element geometry
Wiggins, G. C., Triantafyllou, C., Potthast, A., Reykowski, A., Nittka, M., & Wald, L. L. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20925 · Cited by 375
Computer-assisted imaging to assess brain structure in healthy and diseased brains
Ashburner, J., Csernansk, J. G., Davatzikos, C., Fox, N. C., Frisoni, G. B., & Thompson, P. M. (2003) · The Lancet Neurology · doi:10.1016/s1474-4422(03)00304-1 · Cited by 371
Midbrain iron content in early Parkinson disease: A potential biomarker of disease status
Martin, W. R. W., Wieler, M., & Gee, M. (2008) · Neurology · doi:10.1212/01.wnl.0000286384.31050.b5 · Cited by 354
Quantitative MRI of the Brain: Measuring Changes Caused by Disease
(2003) · Wiley eBooks · doi:10.1002/0470869526 · Cited by 347
Helms, G., Dathe, H., Kallenberg, K., & Dechent, P. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21732 · Cited by 332
Draganski, B., Ashburner, J., Hutton, C., Kherif, F., Frackowiak, R. S. J., Helms, G., & Weiskopf, N. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.052 · Cited by 294
Self-citationAccuracy of dementia diagnosis: a direct comparison between radiologists and a computerized method
Kloppel, S., Stonnington, C. M., Barnes, J., Chen, F., Chu, C., Good, C. D., Mader, I., Mitchell, L. A., Patel, A. C., Roberts, C. C., et al. (2008) · Brain · doi:10.1093/brain/awn239 · Cited by 271
Wright, P. J., Mougin, O. E., Totman, J. J., Peters, A. M., Brookes, M. J., Coxon, R., Morris, P. E., Clemence, M., Francis, S. T., Bowtell, R. W., et al. (2008) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/s10334-008-0104-8 · Cited by 263
Mapping the Human Cortical Surface by Combining Quantitative T1 with Retinotopy†
Sereno, M. I., Lutti, A., Weiskopf, N., & Dick, F. (2013) · Cerebral Cortex · doi:10.1093/cercor/bhs213 · Cited by 261
Self-citationEcker, C. (2012) · Archives of General Psychiatry · doi:10.1001/archgenpsychiatry.2011.1251 · Cited by 259 · cited 1×
“…identified reliable markers for Alzheimer’s disease (Kloppel et al., 2008a,b), distributed anatomical differences in autism spectrum disorder (Ecker, 2012) or the relationship of inter-individual differences in character traits to anatomical differences (Schilling et al., 2013), which would…”
BackgroundQuantitative FLASH MRI at 3T using a rational approximation of the Ernst equation
Helms, G., Dathe, H., & Dechent, P. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21542 · Cited by 231
Preibisch, C., & Deichmann, R. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21776 · Cited by 230
Measurement and Correction of Microscopic Head Motion during Magnetic Resonance Imaging of the Brain
Maclaren, J., Armstrong, B. S. R., Barrows, R. T., Danishad, K. A., Ernst, T., Foster, C. L., Gumus, K., Herbst, M., Kadashevich, I. Y., Kusik, T. P., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0048088 · Cited by 215
Interpreting scan data acquired from multiple scanners: A study with Alzheimer's disease
Stonnington, C. M., Tan, G., Klöppel, S., Chu, C., Draganski, B., Jack, C. R., Chen, K., Ashburner, J., & Frackowiak, R. S. J. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.09.066 · Cited by 213
In Vivo Functional and Myeloarchitectonic Mapping of Human Primary Auditory Areas
Dick, F., Taylor Tierney, A., Lutti, A., Josephs, O., Sereno, M. I., & Weiskopf, N. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.1712-12.2012 · Cited by 209
Self-citationOptimization of 3-D MP-RAGE Sequences for Structural Brain Imaging
Deichmann, R., Good, C. D., Josephs, O., Ashburner, J., & Turner, R. (2000) · NeuroImage · doi:10.1006/nimg.2000.0601 · Cited by 200
Garrido, L., Furl, N., Draganski, B., Weiskopf, N., Stevens, J., Tan, G. C.-Y., Driver, J., Dolan, R. J., & Duchaine, B. (2009) · Brain · doi:10.1093/brain/awp271 · Cited by 192
Self-citationWeiskopf, N., Lutti, A., Helms, G., Novak, M., Ashburner, J., & Hutton, C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.023 · Cited by 191
Self-citationHelms, G., Draganski, B., Frackowiak, R., Ashburner, J., & Weiskopf, N. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.03.053 · Cited by 186
Self-citationWeiskopf, N., Hutton, C., Josephs, O., Turner, R., & Deichmann, R. (2007) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/s10334-006-0067-6 · Cited by 177
Self-citationYarnykh, V. L. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22394 · Cited by 170
Optimization and validation of methods for mapping of the radiofrequency transmit field at 3T
Lutti, A., Hutton, C., Finsterbusch, J., Helms, G., & Weiskopf, N. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22421 · Cited by 166
Self-citationRobust and Fast Whole Brain Mapping of the RF Transmit Field B1 at 7T
Lutti, A., Stadler, J., Josephs, O., Windischberger, C., Speck, O., Bernarding, J., Hutton, C., & Weiskopf, N. (2012) · PLoS ONE · doi:10.1371/journal.pone.0032379 · Cited by 146
Self-citationA new method for fast quantitative mapping of absolute water content in vivo
Neeb, H., Zilles, K., & Shah, N. J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.12.063 · Cited by 137
Deoni, S., Williams, S., Jezzard, P., Suckling, J., Murphy, D., & Jones, D. K. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.11.052 · Cited by 125
Self-citationFast quantitative mapping of absolute water content with full brain coverage
Neeb, H., Ermer, V., Stöcker, T., & Shah, N. J. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.03.060 · Cited by 123
Pardoe, H., Pell, G. S., Abbott, D. F., Berg, A. T., & Jackson, G. D. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.05.007 · Cited by 121
Schilling, C., Kühn, S., Paus, T., Romanowski, A., Banaschewski, T., Barbot, A., Barker, G. J., Brühl, R., Büchel, C., Conrod, P., et al. (2012) · Molecular Psychiatry · doi:10.1038/mp.2012.56 · Cited by 112
Volz, S., Nöth, U., Rotarska-Jagiela, A., & Deichmann, R. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.11.054 · Cited by 105
Helms, G., & Dechent, P. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21629 · Cited by 97
Versluis, M. J., Peeters, J., van Rooden, S., van der Grond, J., van Buchem, M. A., WEBB, A. G., & van Osch, M. J. P. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.048 · Cited by 88
Multi-site voxel-based morphometry — Not quite there yet
Focke, N. K. N., Helms, G., Kaspar, S., Diederich, C., Tóth, V., Dechent, P., Mohr, A., & Paulus, W. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.02.029 · Cited by 87
Volz, S., Nöth, U., Jurcoane, A., Ziemann, U., Hattingen, E., & Deichmann, R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.076 · Cited by 77
Sensitivity of voxel-based morphometry analysis to choice of imaging protocol at 3 T
Tardif, C. L., Collins, D. L., & Pike, G. B. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.09.053 · Cited by 77
Quantitative magnetization transfer in in vivo healthy human skeletal muscle at 3 T
Sinclair, C. D. J., Samson, R. S., Thomas, D. L., Weiskopf, N., Lutti, A., Thornton, J. S., & Golay, X. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22562 · Cited by 76
Self-citationBaudrexel, S., Volz, S., Preibisch, C., Klein, J. C., Steinmetz, H., Hilker, R., & Deichmann, R. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21971 · Cited by 74
Magnetic field dependence of the distribution of NMR relaxation times in the living human brain
Oros‐Peusquens, A., Laurila, M., & Shah, N. J. (2008) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-008-0107-5 · Cited by 73
Helms, G., Dathe, H., & Dechent, P. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22379 · Cited by 70
Assessment and correction of B1‐induced errors in magnetization transfer ratio measurements
Ropele, S., Filippi, M., Valsasina, P., Korteweg, T., Barkhof, F., Tofts, P. S., Samson, R. S., Miller, D. H., & Fazekas, F. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20310 · Cited by 66
Bauer, C. M., Jara, H. J., & Killiany, R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.04.255 · Cited by 52
Tofts, P. S., Steens, S. C. A., Cercignani, M., Admiraal-Behloul, F., Hofman, P. A. M., van Osch, M. J. P., Teeuwisse, W. M., Tozer, D. J., van Waesberghe, J. H. T. M., Yeung, R., et al. (2006) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/s10334-006-0049-8 · Cited by 46
Helms, G., Dathe, H., Weiskopf, N., & Dechent, P. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22849 · Cited by 39
Self-citationMulticentre imaging measurements for oncology and in the brain
Tofts, P. S., & Collins, D. J. (2011) · British Journal of Radiology · doi:10.1259/bjr/74316620 · Cited by 39
Suckling, J., Barnes, A., Job, D. E., Brennan, D., Lymer, K., Dazzan, P., Marques, T. R., Mackay, C. E., McKie, S., Williams, S. R., et al. (2011) · Human Brain Mapping · doi:10.1002/hbm.21210 · Cited by 34
Self-citationThe effect of local perturbation fields on human DTI: Characterisation, measurement and correction
Mohammadi, S., Nagy, Z., Möller, H. E., Symms, M. R., Carmichael, D. W., Josephs, O., & Weiskopf, N. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.009 · Cited by 33
Self-citation
Cited by
Whitaker, K. J., Vértes, P. E., Romero-Garcia, R., Váša, F., Moutoussis, M., Prabhu, G., Weiskopf, N., Callaghan, M. F., Wagstyl, K., Rittman, T., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1601745113 · Cited by 520
Self-citationDevelopmental cognitive neuroscience using latent change score models: A tutorial and applications
Kievit, R. A., Brandmaier, A. M., Ziegler, G., van Harmelen, A.-L., de Mooij, S. M. M., Moutoussis, M., Goodyer, I. M., Bullmore, E., Jones, P. B., Fonagy, P., et al. (2018) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2017.11.007 · Cited by 516
Self-citationSeidlitz, J., Váša, F., Shinn, M., Romero-Garcia, R., Whitaker, K. J., Vértes, P. E., Wagstyl, K., Kirkpatrick Reardon, P., Clasen, L., Liu, S., et al. (2018) · Neuron · doi:10.1016/j.neuron.2017.11.039 · Cited by 500
Self-citationAccurate automatic estimation of total intracranial volume: A nuisance variable with less nuisance
Malone, I. B., Leung, K. K., Clegg, S., Barnes, J., Whitwell, J. L., Ashburner, J., Fox, N. C., & Ridgway, G. R. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.09.034 · Cited by 459
Lifespan maturation and degeneration of human brain white matter
Yeatman, J. D., Wandell, B. A., & Mezer, A. A. (2014) · Nature Communications · doi:10.1038/ncomms5932 · Cited by 432
Metadata
- Authors
- Weiskopf, N., Suckling, J., Williams, G., Correia, M. M., Inkster, B., Tait, R., Ooi, C., Bullmore, E. T., & Lutti, A.
- Venue
- Frontiers in Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2013
- Volume
- 7
- Pages
- 95-95
- ISSN
- 1662-453X (ISSN-L)
- OpenAlex
- W2148417430
- Cited by
- 538
- References
- 53
- FWCI
- 13.55
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.