The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Respiratory Frequency during Exercise: The Neglected Physiological Measure
Open accessAbstract
The use of wearable sensor technology for athlete training monitoring is growing exponentially, but some important measures and related wearable devices have received little attention so far. Respiratory frequency (fR), for example, is emerging as a valuable measurement for training monitoring. Despite the availability of unobtrusive wearable devices measuring fR with relatively good accuracy, fR is not commonly monitored during training. Yet fR is currently measured as a vital sign by multiparameter wearable devices in the military field, clinical settings and occupational activities. When these devices have been used during exercise, fR was used for limited applications like the estimation of the ventilatory threshold. However, more information can be gained from fR. Unlike heart rate, V̇O2 and blood lactate, fR is strongly associated with perceived exertion during a variety of exercise paradigms, and under several experimental interventions affecting performance like muscle fatigue, glycogen depletion, heat exposure and hypoxia. This suggests that fR is a strong marker of physical effort. Furthermore, unlike other physiological variables, fR responds rapidly to variations in workload during high-intensity interval training, with potential important implications for many sporting activities. This Perspective article aims to i) present scientific evidence supporting the relevance of fR for training monitoring; ii) critically revise possible methodologies to measure fR and the accuracy of currently available respiratory wearables; iii) provide preliminary indication on how to analyze fR data. This viewpoint is expected to advance the field of training monitoring and stimulate directions for future development of sports wearables.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Charlton, P. H., Bonnici, T., Tarassenko, L., Clifton, D. A., Beale, R., & Watkinson, P. J. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/4/610 · Cited by 366
Validation of the Hexoskin wearable vest during lying, sitting, standing, and walking activities
Villar, R., Beltrame, T., & Hughson, R. L. (2015) · Applied Physiology Nutrition and Metabolism · doi:10.1139/apnm-2015-0140 · Cited by 178
Estimation of Respiration Rate from Three-Dimensional Acceleration Data Based on Body Sensor Network
Liu, G.-Z., Guo, Y.-W., Zhu, Q.-S., Huang, B.-Y., & Wang, L. (2011) · Telemedicine and e-Health · doi:10.1089/tmj.2011.0022 · Cited by 107
Cited by
The Importance of Respiratory Rate Monitoring: From Healthcare to Sport and Exercise
Nicolò, A., Massaroni, C., Schena, E., & Sacchetti, M. (2020) · Sensors · doi:10.3390/s20216396 · Cited by 440
Self-citationContact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 426
Self-citationFiber Bragg Grating Sensors for Cardiorespiratory Monitoring: A Review
Massaroni, C., Zaltieri, M., Lo Presti, D., Nicolo, A., Tosi, D., & Schena, E. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2988692 · Cited by 128
Self-citationBrammer, J. C., van Peer, J. M., Michela, A., van Rooij, M. M. J. W., Oostenveld, R., Klumpers, F., Dorrestijn, W., Granic, I., & Roelofs, K. (2021) · Frontiers in Psychology · doi:10.3389/fpsyg.2021.586553 · Cited by 38
Metadata
- Authors
- Nicolò, A., Massaroni, C., & Passfield, L.
- Venue
- Frontiers in Physiology
- Publisher
- Frontiers Media SA
- Published
- 2017-12-11
- Volume
- 8
- Pages
- 922-922
- ISSN
- 1664-042X (ISSN-L)
- OpenAlex
- W2774419417
- Cited by
- 208
- References
- 3
- FWCI
- 19.15
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Respiratory Frequency during Exercise: The Neglected Physiological Measure. https://app.cochat.ai/papers/10.3389/fphys.2017.00922
- The paper
- Nicolò, A., Massaroni, C., & Passfield, L. (2017). Respiratory Frequency during Exercise: The Neglected Physiological Measure. Frontiers in Physiology. https://doi.org/10.3389/fphys.2017.00922
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.