Estimation of Vertical Ground Reaction Forces and Sagittal Knee Kinematics During Running Using Three Inertial Sensors
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Analysis of running mechanics has traditionally been limited to a gait laboratory using either force plates or an instrumented treadmill in combination with a full-body optical motion capture system. With the introduction of inertial motion capture systems, it becomes possible to measure kinematics in any environment. However, kinetic information could not be provided with such technology. Furthermore, numerous body-worn sensors are required for a full-body motion analysis. The aim of this study is to examine the validity of a method to estimate sagittal knee joint angles and vertical ground reaction forces during running using an ambulatory minimal body-worn sensor setup. Two concatenated artificial neural networks were trained (using data from eight healthy subjects) to estimate the kinematics and kinetics of the runners. The first artificial neural network maps the information (orientation and acceleration) of three inertial sensors (placed at the lower legs and pelvis) to lower-body joint angles. The estimated joint angles in combination with measured vertical accelerations are input to a second artificial neural network that estimates vertical ground reaction forces. To validate our approach, estimated joint angles were compared to both inertial and optical references, while kinetic output was compared to measured vertical ground reaction forces from an instrumented treadmill. Performance was evaluated using two scenarios: training and evaluating on a single subject and training on multiple subjects and evaluating on a different subject. The estimated kinematics and kinetics of most subjects show excellent agreement (ρ>0.99) with the reference, for single subject training. Knee flexion/extension angles are estimated with a mean RMSE <5°. Ground reaction forces are estimated with a mean RMSE < 0.27 BW. Additionaly, peak vertical ground reaction force, loading rate and maximal knee flexion during stance were compared, however, no significant differences were found. With multiple subject training the accuracy of estimating discrete and continuous outcomes decreases, however, good agreement (ρ > 0.9) is still achieved for seven of the eight different evaluated subjects. The performance of multiple subject learning depends on the diversity in the training dataset, as differences in accuracy were found for the different evaluated subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
OpenSim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement
Delp, S. L., Anderson, F. C., Arnold, A. S., Loan, P., Habib, A., John, C. T., Guendelman, E., & Thelen, D. G. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.901024 · Cited by 4,933 · cited 1×
“Therefore, the proposed method has potential to estimate output based on other kinematic references, such as biomechanical models driven by optical data (Delp et al., 2007; Stief et al., 2013).”
MethodWu, G., Siegler, S., Allard, P., Kirtley, C., Leardini, A., Rosenbaum, D., Whittle, M., D’Lima, D. D., Cristofolini, L., Witte, H., et al. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00222-6 · Cited by 3,242 · cited 1×
“The optical and inertial motion data did not require coordinate systems alignment as the outcome measures were expressed in the joint frame, according to ISB conventions (Wu et al., 2002).”
MethodMeasurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216 · cited 4×
“Optical kinematic 1https://www.vicon.com/downloads/documentation/plug-in-gait-product-guide data was processed using Plug-in Gait (Kadaba et al., 1990; Davis et al., 1991).”
MethodInfluentialA gait analysis data collection and reduction technique
Davis, R. B., Õunpuu, S., Tyburski, D., & Gage, J. R. (1991) · Human Movement Science · doi:10.1016/0167-9457(91)90046-z · Cited by 3,086 · cited 4×
“Optical kinematic 1https://www.vicon.com/downloads/documentation/plug-in-gait-product-guide data was processed using Plug-in Gait (Kadaba et al., 1990; Davis et al., 1991).”
MethodInfluentialIntroduction to Machine Learning
Yu, F. R., & He, Y. (2019) · SpringerBriefs in Electrical and Computer Engineering · doi:10.1007/978-3-030-10546-4_1 · Cited by 1,594
van Gent, R. N., Siem, D., van Middelkoop, M., van Os, A. G., Bierma-Zeinstra, S. M. A., & Koes, B. W. (2007) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.033548 · Cited by 1,420 · cited 1×
“Running is a very popular form of physical activity, that is often accompanied with a high occurrence of lower extremity injuries (incidence rate varies between 19.4 and 79.3%; van Gent et al., 2007).”
BackgroundInfluentialNovacheck, T. F. (1998) · Gait & Posture · doi:10.1016/s0966-6362(97)00038-6 · Cited by 1,257 · cited 3×
“This has traditionally been performed inside a gait laboratory using a three-dimensional optical motion capture system and force plates (Novacheck, 1998).”
BackgroundMethodGround reaction forces in distance running
Cavanagh, P. R., & Lafortune, M. A. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90033-0 · Cited by 1,207 · cited 5×
“, 2012) and ground reaction forces (Cavanagh and Lafortune, 1980), as these are important determinants of running technique (Goss et al.”
BackgroundMethodInfluentialShape google: Geometric words and expressions for invariant shape retrieval
Bronstein, A. M., Bronstein, M. M., Guibas, L. J., & Ovsjanikov, M. (2011) · ACM Transactions on Graphics · doi:10.1145/1899404.1899405 · Cited by 810
Effect of landing stiffness on joint kinetics and energetics in the lower extremity
DEVITA, P., & SKELLY, W. A. (1992) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199201000-00018 · Cited by 771 · cited 4×
“The most relevant kinematic and kinetic parameters analyzed are: joint angles (Devita and Skelly, 1992; Edwards et al., 2012) and ground reaction forces (Cavanagh and Lafortune, 1980), as these are important determinants of running technique (Goss et al., 2012).”
BackgroundMethodInfluential(2009) · Cited by 701
Impact and Overuse Injuries in Runners
Hreljac, A. P. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000126803.66636.dd · Cited by 675 · cited 2×
“…Lafortune, 1980; Novacheck, 1998; Riley et al., 2008; Caekenberghe et al., 2013; Clark et al., 2014), since abnormal peak and/or loading rate values can lead to impact and overuse injuries, when the stress/frequency combination is above the runner’s threshold (Hreljac, 2004; Milner et al., 2007).”
BackgroundA Kinematics and Kinetic Comparison of Overground and Treadmill Running
RILEY, P. O., DICHARRY, J., FRANZ, J., CROCE, U. D., WILDER, R. P., & KERRIGAN, D. C. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181677530 · Cited by 463 · cited 2×
“Ground reaction forces are also relevant outcome parameters for running analysis (e.g., Cavanagh and Lafortune, 1980; Novacheck, 1998; Riley et al., 2008; Caekenberghe et al., 2013; Clark et al., 2014), since abnormal peak and/or loading rate values can lead to impact and overuse injuries, when the stress/frequency co…”
BackgroundGait retraining to reduce lower extremity loading in runners
Crowell, H. P., & Davis, I. S. (2011) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2010.09.003 · Cited by 403 · cited 5×
“Discrete kinetic parameters that are related to running injuries and/or performance are: loading rate and peak vertical ground reaction forces (Crowell and Davis, 2011; Goss et al., 2012; Schmitz et al., 2014), whereas maximal knee flexion during stance is a relevant discrete kinematic parameter…”
BackgroundMethodInfluentialCorey, D. M., Dunlap, W. P., & Burke, M. J. (1998) · The Journal of General Psychology · doi:10.1080/00221309809595548 · Cited by 348 · cited 1×
“The mean ρ over these different strides was calculated using a Fisher transformation to obtain a more representative average Pearson’s correlation coefficient (Corey et al., 1998).”
MethodBiomechanical factors affecting running economy
KYR??L??INEN, H., BELLI, A., & KOMI, P. V. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200108000-00014 · Cited by 320 · cited 1×
“Additionally, improvements in running technique could lead to improved running performance (Kyröläinen et al., 2001; Tartaruga et al., 2012; Folland et al., 2017).”
BackgroundEstimation of Ground Reaction Forces and Moments During Gait Using Only Inertial Motion Capture
Karatsidis, A., Bellusci, G., Schepers, H., De Zee, M., Andersen, M., & Veltink, P. (2016) · Sensors · doi:10.3390/s17010075 · Cited by 287 · cited 7×
“However, our proposed method could be extended using the three-dimensional GRF estimation approach of Karatsidis et al. (2017) using full-body inertial motion capture.”
BackgroundMethodResultInfluentialSelf-citationWhole body inverse dynamics over a complete gait cycle based only on measured kinematics
Ren, L., Jones, R. K., & Howard, D. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.06.001 · Cited by 283 · cited 1×
“…in Physiology | www.frontiersin.org 4 March 2018 | Volume 9 | Article 218 For the knee flexion/extension (F/E) the similarity between the estimates and reference was calculated using the Pearson’s correlation coefficient (ρ) and Root Mean Squared Error (RMSE) (as defined by Ren et al., 2008).”
MethodA kinematic comparison of overground and treadmill running
NIGG, B. M., DE BOER, R. W., & FISHER, V. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199501000-00018 · Cited by 258 · cited 1×
“Previous studies have confirmed this, showing significant differences between running on a treadmill and outdoors (Nigg et al., 1995).”
Running Technique is an Important Component of Running Economy and Performance
FOLLAND, J. P., ALLEN, S. J., BLACK, M. I., HANDSAKER, J. C., & FORRESTER, S. E. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001245 · Cited by 249 · cited 1×
“Additionally, improvements in running technique could lead to improved running performance (Kyröläinen et al., 2001; Tartaruga et al., 2012; Folland et al., 2017).”
BackgroundMotion reconstruction using sparse accelerometer data
Tautges, J., Zinke, A., Krüger, B., Baumann, J., Weber, A., Helten, T., Müller, M., Seidel, H.-P., & Eberhardt, B. (2011) · ACM Transactions on Graphics · doi:10.1145/1966394.1966397 · Cited by 197 · cited 1×
“Tautges et al. (2011) proposed a method for full-body motion capture by using a limited number of accelerometers; however, their nearest neighbor approach requires a database of prerecorded movements to be available at run-time.”
MethodReenalda, J., Maartens, E., Homan, L., & Buurke, J. H. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.08.032 · Cited by 184 · cited 2×
“Reenalda et al. (2016) have used IMUs to measure the effects of fatigue on running mechanics during an actual marathon.”
BackgroundMethodSelf-citationThe Relationship Between Running Economy and Biomechanical Variables in Distance Runners
Tartaruga, M. P., Brisswalter, J., Peyré-Tartaruga, L. A., Ávila, A. O. V., Alberton, C. L., Coertjens, M., Cadore, E. L., Tiggemann, C. L., Silva, E. M., & Kruel, L. F. M. (2012) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2012.10599870 · Cited by 181
Joint kinematic calculation based on clinical direct kinematic versus inverse kinematic gait models
Kainz, H., Modenese, L., Lloyd, D. G., Maine, S., Walsh, H. P. J., & Carty, C. P. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.03.052 · Cited by 173 · cited 2×
“Differences in the reference knee F/E profiles for the different technologies are observed for the results in section 3.1.1, which can be explained by differences in the underlying models of the human body and their assumptions (Kainz et al., 2016).”
BackgroundInfluentialThree-dimensional kinematic comparison of treadmill and overground running
SINCLAIR, J. K., Richards, J., TAYLOR, P. J., Edmundson, C. J., Brooks, D., & Hobbs, S. J. (2013) · Sports Biomechanics · doi:10.1080/14763141.2012.759614 · Cited by 149 · cited 1×
“However, a lab setting is not identical to the regular running environment and may therefore result in different kinematics and kinetics (Sinclair et al., 2013).”
BackgroundAre knee mechanics during early stance related to tibial stress fracture in runners?
Milner, C. E., Hamill, J., & DAVIS, I. M. (2007) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.03.003 · Cited by 146 · cited 2×
“…Lafortune, 1980; Novacheck, 1998; Riley et al., 2008; Caekenberghe et al., 2013; Clark et al., 2014), since abnormal peak and/or loading rate values can lead to impact and overuse injuries, when the stress/frequency combination is above the runner’s threshold (Hreljac, 2004; Milner et al., 2007).”
BackgroundStief, F., Böhm, H., Michel, K., Schwirtz, A., & Döderlein, L. (2013) · Journal of Applied Biomechanics · doi:10.1123/jab.29.1.105 · Cited by 135 · cited 1×
“Therefore, the proposed method has potential to estimate output based on other kinematic references, such as biomechanical models driven by optical data (Delp et al., 2007; Stief et al., 2013).”
MethodAmbulatory assessment of 3D ground reaction force using plantar pressure distribution
Rouhani, H., Favre, J., Crevoisier, X. M., & Aminian, K. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2010.05.014 · Cited by 107 · cited 1×
“Furthermore, 3D ground reaction forces could be measured using pressure insoles for example (Rouhani et al., 2010), which enables data collection in any running environment for training data collection.”
MethodFaber, G. S., Chang, C.-C., Kingma, I., Dennerlein, J. T., & van Dieën, J. H. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.11.042 · Cited by 102 · cited 6×
“Previous studies have achieved varying performance in GRF estimation (Shippen and May, 2012; Charry et al., 2013; Faber et al., 2016; Karatsidis et al., 2017; Nedergaard et al., 2017; Pavei et al., 2017).”
BackgroundMethodResultInfluentialGyroscope-based assessment of temporal gait parameters during treadmill walking and running
McGrath, D., Greene, B. R., O’Donovan, K. J., & Caulfield, B. M. (2012) · Sports Engineering · doi:10.1007/s12283-012-0093-8 · Cited by 85 · cited 1×
“Running applications using a minimal inertial sensor set have mainly focused on temporal outcomes, such as the use of gyroscopes on the feet to estimate temporal running parameters (McGrath et al., 2012).”
MethodFoot speed, foot-strike and footwear:linking gait mechanics and running ground reaction forces
Clark, K. P., Ryan, L. J., & Weyand, P. G. (2014) · Journal of Experimental Biology · doi:10.1242/jeb.099523 · Cited by 81 · cited 2×
“Ground reaction forces are also relevant outcome parameters for running analysis (e.g., Cavanagh and Lafortune, 1980; Novacheck, 1998; Riley et al., 2008; Caekenberghe et al., 2013; Clark et al., 2014), since abnormal peak and/or loading rate values can lead to impact and overuse injuries, when the stress/frequency co…”
BackgroundHuman motion capture sensors and analysis in robotics
Field, M., Pan, Z. S., Stirling, D. A., & Naghdy, F. (2011) · Industrial Robot the international journal of robotics research and application · doi:10.1108/01439911111106372 · Cited by 70 · cited 1×
“Each of these technologies have their advantages and disadvantages (Field et al., 2011).”
BackgroundMusculoskeletal Attenuation of Impact Shock in Response to Knee Angle Manipulation
Edwards, W. B., Derrick, T. R., & Hamill, J. (2012) · Journal of Applied Biomechanics · doi:10.1123/jab.28.5.502 · Cited by 64 · cited 6×
“…of the proposed method was evaluated by comparing both discrete and continuous outcomes, as commonly done in similar works about biomechanical analysis of running (Cavanagh and Lafortune, 1980; Devita and Skelly, 1992; Crowell and Davis, 2011; Edwards et al., 2012; Schmitz et al., 2014).”
BackgroundMethodInfluentialMechanics of overground accelerated running vs. running on an accelerated treadmill
Caekenberghe, I. V., Segers, V., Willems, P. A., Gosseye, T. P., Aerts, P., & Clercq, D. D. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.10.022 · Cited by 59 · cited 1×
“…reaction forces are also relevant outcome parameters for running analysis (e.g., Cavanagh and Lafortune, 1980; Novacheck, 1998; Riley et al., 2008; Caekenberghe et al., 2013; Clark et al., 2014), since abnormal peak and/or loading rate values can lead to impact and overuse injuries, when the…”
BackgroundEstimation of Full-Body Poses Using Only Five Inertial Sensors: An Eager or Lazy Learning Approach?
Wouda, F. J., Matteo Giuberti, A., Bellusci, G., & Veltink, P. H. (2016) · Sensors · doi:10.3390/s16122138 · Cited by 56 · cited 5×
“In accordance with previous work of the authors (Wouda et al., 2016), a two-layer (with 250 and 100 neurons) function fitting neural network architecture was used for both ANNs, capable of mapping non-linearities between input and output.”
MethodInfluentialSelf-citationA kinematic method to detect foot contact during running for all foot strike patterns
Milner, C. E., & Paquette, M. R. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.07.036 · Cited by 55 · cited 1×
“For analysis, the kinematic and kinetic data were segmented in stance phases using a 20 N threshold (Milner and Paquette, 2015).”
MethodAssessment of Foot Kinematics During Steady State Running Using a Foot-mounted IMU
Bailey, G. P., & Harle, R. K. (2014) · Procedia Engineering · doi:10.1016/j.proeng.2014.06.009 · Cited by 53 · cited 1×
“Bailey and Harle (2014, 2015) showed that with foot-mounted IMUs this can be extended to estimate spatiotemporal running parameters.”
BackgroundStudy on estimation of peak Ground Reaction Forces using tibial accelerations in running
Charry, E., Hu, W., Umer, M., Ronchi, A., & Taylor, S. B. (2013) · International Conference on Intelligent Sensors, Sensor Networks and Information Processing · doi:10.1109/issnip.2013.6529804 · Cited by 48 · cited 4×
“The peak vertical ground reaction forces (vGRF) estimation approach of Charry et al. (2013) relied only on tibial accelerations, but was not suitable for estimation of kinetics during the whole stance phase.”
MethodResultInfluentialEstimates of Running Ground Reaction Force Parameters from Motion Analysis
Pavei, G., Seminati, E., Storniolo, J. L., & Peyré‐Tartaruga, L. A. (2016) · Journal of Applied Biomechanics · doi:10.1123/jab.2015-0329 · Cited by 25 · cited 5×
“Pavei et al. (2017) reported similar performance in estimation of the loading rate, while our proposed method was shown to estimate peak vGRFs more accurately.”
BackgroundResultInfluentialMeasuring Temporal Parameters of Gait with Foot Mounted IMUs in Steady State Running
Bailey, G. P., & Harle, R. K. (2015) · International Conference on Sport Sciences Research and Technology Support (icSPORTS) · doi:10.5220/0005656500240033 · Cited by 11 · cited 1×
“Bailey and Harle (2014, 2015) showed that with foot-mounted IMUs this can be extended to estimate spatiotemporal running parameters.”
Background
Cited by
Estimation of Knee Joint Forces in Sport Movements Using Wearable Sensors and Machine Learning
Stetter, B. J., Ringhof, S., Krafft, F. C., Sell, S., & Stein, T. (2019) · Sensors · doi:10.3390/s19173690 · Cited by 130
Mundt, M., Johnson, W. R., Potthast, W., Markert, B., Mian, A., & Alderson, J. (2021) · Sensors · doi:10.3390/s21134535 · Cited by 95
Molinaro, D. D., Kang, I., Camargo, J., Gombolay, M. C., & Young, A. J. (2022) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2022.3144025 · Cited by 90
Martínez-Pascual, D., Catalán, J. M., Blanco-Ivorra, A., Sanchís, M., Arán-Ais, F., & García-Aracil, N. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1199459 · Cited by 21
“F. J. Wouda et al. also used IMU sensors over the lower limbs (pelvis and lower legs) (Wouda et al., 2018).”
Method
Metadata
- Authors
- Wouda, F. J., Giuberti, M., Bellusci, G., Maartens, E., Reenalda, J., van Beijnum, B.-J. F., & Veltink, P. H.
- Venue
- Frontiers in Physiology
- Publisher
- Frontiers Media SA
- Published
- 2018-03-22
- Volume
- 9
- Pages
- 218-218
- ISSN
- 1664-042X (ISSN-L)
- OpenAlex
- W2790295149
- Cited by
- 207
- References
- 42
- FWCI
- 6.98
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.