Abstract
We present the first in vitro extracellular stimulation of individual neurons from dissociated cultures with iridium oxide (IrO(x)) electrodes. Microelectrode arrays with sputtered IrO(x) films (SIROF) were developed for electrophysiological investigations with electrogenic cells. The microelectrodes were characterized with scanning electron and atomic force microscopy, revealing rough and porous electrodes with enlarged surface areas. As shown by cyclic voltammetry and electrochemical impedance spectroscopy, the large surface area in combination with the good electrochemical properties of SIROF resulted in high charge storage capacity and low electrode impedance. Thus, we could transfer the good properties of IrO(x) as material for in vivo stimulation electrodes to multi-electrode arrays with electrode diameters as small as 10 mum for in vitro applications. Single rat cortical neurons from dissociated cultures were successfully stimulated to fire action potentials using single or trains of biphasic rectangular voltage-controlled stimulation pulses. The stimulated cell's membrane potential was simultaneously monitored using whole-cell current-clamp recordings. This experimental configuration allowed direct evaluation of the influence of pulse phase sequence, amplitude, and number on the stimulation success ratio and action potential latency. Negative phase first pulses were more effective for extracellular stimulation and caused reduced latency in comparison to positive phase first pulses. Increasing the pulse amplitude also improved stimulation reliability. However, in order to prevent cell or electrode damage, the pulse amplitude is limited to voltages below the threshold for irreversible electrochemical reactions at the electrode. As an alternative to increasing the amplitude, a higher number of stimulation pulses was also shown to increase stimulation success.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · cited 8×
“At the same time, cell and device damage must be prevented by using electrode voltages within the safe electrochemical window, where no irreversible electrochemical reactions such as gas evolution occur (Brummer et al., 1983; Huang et al., 2001; Merrill et al., 2005; Cogan, 2008).”
InfluentialElectrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 8×
“At the same time, cell and device damage must be prevented by using electrode voltages within the safe electrochemical window, where no irreversible electrochemical reactions such as gas evolution occur (Brummer et al., 1983; Huang et al., 2001; Merrill et al., 2005; Cogan, 2008).”
InfluentialCarbon nanotube coating improves neuronal recordings
Keefer, E. W., Botterman, B. R., Romero, M. I., Rossi, A. F., & Gross, G. W. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.174 · Cited by 721
In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382 · cited 6×
“With values between roughly 5 and 10 mC/cm(2), the cathodal charge storage capacity of the microelectrodes was found to be higher than for other electrode materials such as plain and platinized gold, platinum, and TiN and within the range (roughly 1–25 mC/cm(2)) of other IrO x electrodes (Robblee et al., 1983; Aurian-…”
InfluentialWeiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371
Brummer, S. B., Robblee, L. S., & Hambrecht, F. T. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31628.x · Cited by 205
Silicon-neuron junction: capacitive stimulation of an individual neuron on a silicon chip.
Fromherz, P., & Stett, A. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.1670 · Cited by 167
Sputtered Iridium Oxide Films as Charge Injection Material for Functional Electrostimulation
Slavcheva, E., Vitushinsky, R., Mokwa, W., & Schnakenberg, U. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1747881 · Cited by 154 · cited 7×
“However, this and other publications showed that the surface roughness severely depends on the production process, and can be further increased by variation of process parameters such as number of activation cycles and oxygen fl ow during sputtering (Slavcheva et al., 2004, 2006).”
MethodInfluentialElectrical stimulation and recording from cultured neurons using a planar electrode array
Jimbo, Y., & Kawana, A. (1992) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(92)80067-q · Cited by 126 · cited 8×
“…2 | Article 16 | 1 NEUROENGINEERING ORIGINAL RESEARCH ARTICLE published: 16 November 2009 doi: 10.3389/neuro.16.016.2009 current-controlled extracellular stimulation of electrically excitable cells (Pine, 1980; Regehr et al., 1988; Jimbo and Kawana, 1992; Gross et al., 1993; Maher et al., 1999).”
Influential
Cited by
In Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording
Venkatraman, S., Hendricks, J., King, Z. A., Sereno, A. J., Richardson-Burns, S., Martin, D., & Carmena, J. M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2109399 · Cited by 319
Neural interfaces engineered via micro- and nanostructured coatings
Chen, N., Tian, L., Patil, A. C., Peng, S., Yang, I. H., Thakor, N. V., & Ramakrishna, S. (2017) · Nano Today · doi:10.1016/j.nantod.2017.04.007 · Cited by 74
Yin, P., Liu, Y., Xiao, L., & Zhang, C. (2021) · Polymers · doi:10.3390/polym13162834 · Cited by 42
“The neural microelectrode coated with IrOx displayed an excellent stimulating function for individual neurons and recorded multiple single-unit spike activity with good signal-to-noise ratios [89,90].”
BackgroundHigh-frequency electrical stimulation of cardiac cells and application to artifact reduction.
Dura, B., Chen, M. Q., Inan, O. T., Kovacs, G. T. A., & Giovangrandi, L. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2188136 · Cited by 15
Metadata
- Authors
- Eick, S.
- Venue
- Frontiers in Neuroengineering
- Publisher
- Frontiers Media SA
- Published
- 2009
- Volume
- 2
- Pages
- 16-16
- ISSN
- 1662-6443 (ISSN-L)
- OpenAlex
- W2022819273
- Cited by
- 46
- References
- 9
- FWCI
- 1.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Iridium oxide microelectrode arrays for in-vitro stimulation of individual rat neurons from dissociated cultures. https://app.cochat.ai/papers/10.3389/neuro.16.016.2009
- The paper
- Eick, S. (2009). Iridium oxide microelectrode arrays for in-vitro stimulation of individual rat neurons from dissociated cultures. Frontiers in Neuroengineering. https://doi.org/10.3389/neuro.16.016.2009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.