The DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
The NIRS Brain AnalyzIR Toolbox
Open accessAbstract
Functional near-infrared spectroscopy (fNIRS) is a noninvasive neuroimaging technique that uses low-levels of light (650–900 nm) to measure changes in cerebral blood volume and oxygenation. Over the last several decades, this technique has been utilized in a growing number of functional and resting-state brain studies. The lower operation cost, portability, and versatility of this method make it an alternative to methods such as functional magnetic resonance imaging for studies in pediatric and special populations and for studies without the confining limitations of a supine and motionless acquisition setup. However, the analysis of fNIRS data poses several challenges stemming from the unique physics of the technique, the unique statistical properties of data, and the growing diversity of non-traditional experimental designs being utilized in studies due to the flexibility of this technology. For these reasons, specific analysis methods for this technology must be developed. In this paper, we introduce the NIRS Brain AnalyzIR toolbox as an open-source Matlab-based analysis package for fNIRS data management, pre-processing, and first- and second-level (i.e., single subject and group-level) statistical analysis. Here, we describe the basic architectural format of this toolbox, which is based on the object-oriented programming paradigm. We also detail the algorithms for several of the major components of the toolbox including statistical analysis, probe registration, image reconstruction, and region-of-interest based statistics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482
Estimating the Dimension of a Model
Schwarz, G. (1978) · The Annals of Statistics · doi:10.1214/aos/1176344136 · Cited by 47,033
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856 · cited 17×
“The two plots types presented show the ROC curve (Figure 3b/e) and the control for type-I error (Figure 3c/f).”
BackgroundMethodInfluentialTzourio-Mazoyer, N., Landeau, B., Papathanassiou, D., Crivello, F., Etard, O., Delcroix, N., Mazoyer, B., & Joliot, M. (2002) · NeuroImage · doi:10.1006/nimg.2001.0978 · Cited by 16,319
Complex network measures of brain connectivity: Uses and interpretations
Rubinov, M., & Sporns, O. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.003 · Cited by 11,522
Cortical Surface-Based Analysis
Dale, A. M., Fischl, B., & Sereno, M. I. (1999) · NeuroImage · doi:10.1006/nimg.1998.0395 · Cited by 10,910
Application of the cross wavelet transform and wavelet coherence to geophysical time series
Grinsted, A., Moore, J. C., & Jevrejeva, S. (2004) · Nonlinear Processes in Geophysics · doi:10.5194/npg-11-561-2004 · Cited by 6,285
Automatically Parcellating the Human Cerebral Cortex
Fischl, B. (2004) · Cerebral Cortex · doi:10.1093/cercor/bhg087 · Cited by 4,253
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008
Factoring and weighting approaches to status scores and clique identification
Bonacich, P. (1972) · The Journal of Mathematical Sociology · doi:10.1080/0022250x.1972.9989806 · Cited by 3,207
Optical tomography in medical imaging
Arridge, S. R. (1999) · Inverse Problems · doi:10.1088/0266-5611/15/2/022 · Cited by 2,524
Ferrari, M., & Quaresima, V. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.049 · Cited by 2,274
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
HomER: A review of time-series analysis methods for near-infrared spectroscopy of the brain
Huppert, T. J., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d280 · Cited by 1,817
Self-citationSome Unique Properties of Eigenvector Centrality
Bonacich, P. (2007) · Social Networks · doi:10.1016/j.socnet.2007.04.002 · Cited by 1,572
The Generalization of Student's Ratio
Hotelling, H. (1931) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177732979 · Cited by 1,492
Enhancement of MR Images Using Registration for Signal Averaging
Holmes, C. J., Hoge, R., Collins, L., Woods, R., Toga, A. W., & Evans, A. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199803000-00032 · Cited by 1,417
NIRS-SPM: Statistical parametric mapping for near-infrared spectroscopy
YE, J., TAK, S., JANG, K., JUNG, J., & JANG, J. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.08.036 · Cited by 1,180
The Fitting of Power Series, Meaning Polynomials, Illustrated on Band-Spectroscopic Data
Beaton, A. E., & Tukey, J. W. (1974) · Technometrics · doi:10.1080/00401706.1974.10489171 · Cited by 1,010
Symbolic Description of Factorial Models for Analysis of Variance
Wilkinson, G. N., & Rogers, C. E. (1973) · Applied Statistics · doi:10.2307/2346786 · Cited by 901
Lloyd-Fox, S., Blasi, A., & Elwell, C. E. (2010) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2009.07.008 · Cited by 865
Google's PageRank and Beyond: The Science of Search Engine Rankings
Langville, A. N., & Meyer, C. D. (2006) · doi:10.1515/9781400830329 · Cited by 814
Cortical Mapping of Gait in Humans: A Near-Infrared Spectroscopic Topography Study
Miyai, I., Tanabe, H. C., Sase, I., Eda, H., Oda, I., Konishi, I., Tsunazawa, Y., Suzuki, T., Yanagida, T., & Kubota, K. (2001) · NeuroImage · doi:10.1006/nimg.2001.0905 · Cited by 788
Dehghani, H., Eames, M. E., Yalavarthy, P. K., Davis, S. C., Srinivasan, S., Carpenter, C. M., Pogue, B. W., & Paulsen, K. D. (2009) · Communications in Numerical Methods in Engineering · doi:10.1002/cnm.1162 · Cited by 728
Boas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Tetrahedral mesh generation from volumetric binary and grayscale images
Fang, Q., & Boas, D. A. (2009) · 2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro · doi:10.1109/isbi.2009.5193259 · Cited by 691
Rolls, E. T., Joliot, M., & Tzourio-Mazoyer, N. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.07.075 · Cited by 682
Wavelet-based motion artifact removal for functional near-infrared spectroscopy
Molavi, B., & Dumont, G. A. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/2/259 · Cited by 623
Tachtsidis, I., & Scholkmann, F. (2016) · Neurophotonics · doi:10.1117/1.nph.3.3.031405 · Cited by 607
Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
Boas, D. A., Culver, J. P., Stott, J. J., & Dunn, A. K. (2002) · Optics Express · doi:10.1364/oe.10.000159 · Cited by 599
Quaresima, V., & Ferrari, M. (2019) · Organizational Research Methods · doi:10.1177/1094428116658959 · Cited by 419
Anatomical guidance for functional near-infrared spectroscopy: AtlasViewer tutorial
Aasted, C. M., Yücel, M. A., Cooper, R. J., Dubb, J., Tsuzuki, D., Becerra, L., Petkov, M. P., Borsook, D., Dan, I., & Boas, D. A. (2015) · Neurophotonics · doi:10.1117/1.nph.2.2.020801 · Cited by 409
Takahashi, T., Takikawa, Y., Kawagoe, R., Shibuya, S., Iwano, T., & Kitazawa, S. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.05.012 · Cited by 396
Mesh-based Monte Carlo method using fast ray-tracing in Plücker coordinates
Fang, Q. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000165 · Cited by 384
Zhang, Y., Brooks, D. H., Franceschini, M. A., & Boas, D. A. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1852552 · Cited by 373
Autoregressive model based algorithm for correcting motion and serially correlated errors in fNIRS
Barker, J. W., Aarabi, A., & Huppert, T. J. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.001366 · Cited by 337
Self-citationWavelet minimum description length detrending for near-infrared spectroscopy
Jang, K. E., Tak, S., Jung, J., Jang, J., Jeong, Y., & Ye, J. C. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3127204 · Cited by 279
NIRS in clinical neurology — a ‘promising’ tool?
Obrig, H. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.03.045 · Cited by 227
Huppert, T. J. (2016) · Neurophotonics · doi:10.1117/1.nph.3.1.010401 · Cited by 226
Self-citationA vascular anatomical network model of the spatio-temporal response to brain activation
Boas, D. A., Jones, S. R., Devor, A., Huppert, T. J., & Dale, A. M. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.12.061 · Cited by 222
Self-citationFunctional Near Infrared Spectroscopy: Enabling routine functional brain imaging
Yücel, M. A., Selb, J. J., Huppert, T. J., Franceschini, M. A., & Boas, D. A. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.09.011 · Cited by 222
Self-citationA state-space model of the hemodynamic approach: nonlinear filtering of BOLD signals
Riera, J. J., Watanabe, J., Kazuki, I., Naoki, M., Aubert, E., Ozaki, T., & Kawashima, R. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.09.052 · Cited by 186
Jermyn, M., Ghadyani, H., Mastanduno, M. A., Turner, W., Davis, S. C., Dehghani, H., & Pogue, B. W. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.8.086007 · Cited by 186
Hoge, R. D., Franceschini, M. A., Covolan, R. J. M., Huppert, T. J., Mandeville, J. B., & Boas, D. A. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.12.032 · Cited by 132
Self-citationSignificance testing in ridge regression for genetic data
Cule, E., Vineis, P., & Iorio, M. D. (2011) · BMC Bioinformatics · doi:10.1186/1471-2105-12-372 · Cited by 124
Huppert, T. J., Allen, M., Benav, H., Jones, P., & Boas, D. A. (2007) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600435 · Cited by 111
Self-citationSantosa, H., Aarabi, A., Perlman, S. B., & Huppert, T. J. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.5.055002 · Cited by 104
Self-citationKarim, H. T., Fuhrman, S. I., Sparto, P. J., FURMAN, J. M. R., & Huppert, T. J. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.02.010 · Cited by 94
Self-citationAccelerating mesh-based Monte Carlo method on modern CPU architectures
Fang, Q., & Kaeli, D. R. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.003223 · Cited by 86
Huppert, T. J., Barker, J. W., Schmidt, B., Walls, S. A., & Ghuman, A. S. (2017) · Neurophotonics · doi:10.1117/1.nph.4.1.015001 · Cited by 58
Self-citationEstimating cerebral oxygen metabolism from fMRI with a dynamic multicompartment Windkessel model
Huppert, T. J., Allen, M., Diamond, S. G., & Boas, D. A. (2008) · Human Brain Mapping · doi:10.1002/hbm.20628 · Cited by 55
Self-citationFunctional MR imaging of a simulated balance task
Karim, H. T., Sparto, P. J., Aizenstein, H. J., FURMAN, J. M. R., Huppert, T. J., Erickson, K. I., & Loughlin, P. J. (2014) · Brain Research · doi:10.1016/j.brainres.2014.01.033 · Cited by 54
Self-citationBarker, J. W., Rosso, A. L., Sparto, P. J., & Huppert, T. J. (2016) · Neurophotonics · doi:10.1117/1.nph.3.3.031410 · Cited by 53
Self-citationDirect estimation of evoked hemoglobin changes by multimodality fusion imaging
Huppert, T. J., Diamond, S. G., & Boas, D. A. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2976432 · Cited by 42
Self-citationAbdelnour, F., Genovese, C. R., & Huppert, T. J. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.001084 · Cited by 37
Self-citationTopographic localization of brain activation in diffuse optical imaging using spherical wavelets
Abdelnour, F., Schmidt, B., & Huppert, T. J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/20/023 · Cited by 31
Self-citationA random-effects model for group-level analysis of diffuse optical brain imaging
Abdelnour, F., & Huppert, T. J. (2010) · Biomedical Optics Express · doi:10.1364/boe.2.000001 · Cited by 28
Self-citationHuppert, T. J., Karim, H. T., Lin, C.-C., Alqahtani, B. A., Greenspan, S. L., & Sparto, P. J. (2017) · PLoS ONE · doi:10.1371/journal.pone.0184918 · Cited by 26
Self-citationValidation of the hypercapnic calibrated fMRI method using DOT–fMRI fusion imaging
Yücel, M. A., Evans, K. C., Selb, J. J., Huppert, T. J., Boas, D. A., & Gagnon, L. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.08.052 · Cited by 15
Self-citation
Cited by
Temporal Derivative Distribution Repair (TDDR): A motion correction method for fNIRS
Fishburn, F. A., Ludlum, R. S., Vaidya, C. J., & Medvedev, A. V. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.025 · Cited by 516
Self-citationBest practices for fNIRS publications
Yücel, M. A., Lühmann, A. V., Scholkmann, F., Gervain, J., Dan, I., Ayaz, H., Boas, D., Cooper, R. J., Culver, J., Elwell, C. E., et al. (2021) · Neurophotonics · doi:10.1117/1.nph.8.1.012101 · Cited by 492
Herold, F., Wiegel, P., Scholkmann, F., & Müller, N. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7120466 · Cited by 482
Yu, Q., Zhang, Z., Ludyga, S., Erickson, K. I., Cheval, B., Hou, M., Pindus, D. M., Hillman, C. H., Kramer, A. F., Falck, R. S., et al. (2025) · Advanced Science · doi:10.1002/advs.202406631 · Cited by 27
Aitken, A., Jounghani, A. R., Carbonell, L. M., Tadeo, D., Kumar, A., Crawford, S., Bowden, A. K., & Hosseini, S. M. H. (2025) · Scientific Reports · doi:10.1038/s41598-025-20844-7 · Cited by 24
Metadata
- Authors
- Santosa, H., Zhai, X., Fishburn, F., & Huppert, T.
- Venue
- Algorithms
- Publisher
- MDPI AG
- Published
- 2018-05-16
- Volume
- 11
- Issue
- 5
- Pages
- 73
- ISSN
- 1999-4893 (ISSN-L)
- OpenAlex
- W2803554436
- Cited by
- 440
- References
- 60
- FWCI
- 18.27
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.