Transfer Learning Algorithm of P300-EEG Signal Based on XDAWN Spatial Filter and Riemannian Geometry Classifier
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index; 2 of the 15 sources its claims cite were checked for support.
Abstract
The electroencephalogram (EEG) signal in the brain–computer interface (BCI) has suffered great cross-subject variability. The BCI system needs to be retrained before each time it is used, which is a waste of resources and time. Thus, it is difficult to generalize a fixed classification method for all subjects. Therefore, the transfer learning method proposed in this article, which combines XDAWN spatial filter and Riemannian Geometry classifier (RGC), can achieve offline cross-subject transfer learning in the P300-speller paradigm. The XDAWN spatial filter is used to enhanced the P300 components in the raw signal as well as reduce its dimensions. Then, the Riemannian Geometry Mean (RGM) is used as the reference matrix to perform the affine transformation of the symmetric positive definite (SPD) covariance matrix calculated from the filtered signal, which makes the data from different subjects comparable. Finally, the RGC is used to obtain the result of transfer learning experiments. The proposed algorithm was evaluated on two datasets (Dataset I from real patients and Dataset II from the laboratory). By comparing with two state-of-the-art and classic algorithms in the current BCI field, Ensemble of Support Vector Machine (E-SVM) and Stepwise Linear Discriminant Analysis (SWLDA), the maximum averaged area under the receiver operating characteristic curve (AUC) score of our algorithm reached 0.836, proving the potential of our proposed algorithm.
Overview
CoChat Summary
TL;DR
The paper proposes an offline cross-subject transfer learning method for P300-EEG that combines an XDAWN spatial filter with a Riemannian Geometry classifier, using each subject’s Riemannian Geometry mean to affine-transform SPD covariance matrices so data from different subjects become comparable. Across two P300-speller datasets, the method outperformed E-SVM and SWLDA, reaching a maximum average AUC of 0.836.
Key findings
- In one-to-one transfer learning, XDAWN + RGC achieved average AUC 0.776 on Dataset I (max 0.821) and 0.787 on Dataset II (max 0.813), compared with E-SVM averages of 0.547 and 0.542 and SWLDA averages of 0.548 and 0.552.
- In all-to-one transfer learning, XDAWN + RGC achieved average AUC 0.836 on Dataset I (max 0.879) and 0.830 on Dataset II (max 0.865), compared with E-SVM averages of 0.636 and 0.650 and SWLDA averages of 0.655 and 0.660.
- XDAWN + RGC also improved slightly over RGC alone in both experiments; for example, all-to-one Dataset I RGC averaged 0.800 versus 0.836 for XDAWN + RGC.
- Visualization of two subjects per dataset showed that after affine transformation, SPD covariance matrices were more concentrated and consistent in spatial distribution.
Methods
- Dataset I was a public P300-speller dataset from eight ALS subjects, with 420 samples per subject (70 P300, 350 non-P300), 8 channels, 256 Hz sampling, and 0.1–30 Hz bandpass filtering. Dataset II was collected from 10 healthy subjects (five men, five women), with 1200 samples per subject (30 P300, 1170 non-P300), 32 channels, 250 Hz sampling, and 0.1–60 Hz bandpass filtering.
- Preprocessing selected 0–0.5 s after flashing, applied a fifth-order Butterworth 0.1–20 Hz bandpass filter, and downsampled to 34 Hz.
- The algorithm applies XDAWN spatial filtering to enhance P300 components and reduce dimensions, computes SPD covariance matrices, affine-transforms them using each subject’s Riemannian Geometry mean as reference, maps them onto the Riemannian manifold, and classifies by minimum Riemannian distance to class means. Experiments used one-to-one leave-one-subject-out transfer and all-to-one leave-one-out transfer with Bootstrap Aggregating voting; performance was measured by AUC due to class imbalance.
Limitations
- The paper does not present a dedicated limitations section; it states that future work will focus on a more robust BCI transfer learning algorithm that can be used online, indicating the current method is offline.
- Evident from the text: evaluation is limited to offline cross-subject transfer within two P300-speller datasets, with no online or real-time validation reported.
- Evident from the text: transfer learning is defined as training on Subject A and testing on Subject B from the same dataset, so cross-dataset generalization is not tested; sample sizes are also limited to 8 ALS subjects in Dataset I and 10 healthy subjects in Dataset II.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
2 Valid · 1 Not valid · 9 Not checked · 27 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“It can be seen in Figure 7 that our method is still stable overall”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“By comparing with two state-of-the-art and classic algorithms in the current BCI field, Ensemble of Support Vector Machine (E-SVM) and Stepwise Linear Discriminant Analysis (SWLDA), the maximum averaged area under the receiver operating characteristic curve (AUC) score of our algorithm reached 0.836, proving the potential of our proposed algorithm.”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
In the paper
“In addition, the BCI system requires a long calibration phase before each time it is used because, to achieve a good performance, every subject’s BCI system needs to be trained by their own EEG signals and cannot use other’s EEG signals [11].”
What the sources say
- Not checked — no full text of the sourcecites [11] Lotte, 2015, Signal Processing Approaches to Minimize or Suppress Calibration Time in Oscillatory Activity-Based Brain–Computer Interfaces, Proc. IEEE source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim have been checked yet.
In the paper
“The electroencephalogram (EEG) signal in the brain–computer interface (BCI) has suffered great cross-subject variability.”
- Also stated in: § Transfer Learning Algorithm of P300-EEG Signal Based on XDAWN Spatial Filter and Riemannian Geometry Classifier · plain
“One of the main reasons hindering the widespread use of BCI systems is the variability of EEG signals [1,9].”
What the sources say
- Not matchedcites [1] Clerc, 2013, Brain Computer Interfaces, Principles and Practise, Biomed. Eng. Online
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Not checked — no full text of the sourcecites [9] Blankertz, 2010, Neurophysiological predictor of SMR-based BCI performance, Neuroimage source
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § Transfer Learning Algorithm of P300-EEG Signal Based on XDAWN Spatial Filter and Riemannian Geometry Classifier · plain
In the paper
“Due to the variability, the feature space distribution of the EEG signal collected from different subjects or different sessions are inconsistent [10].”
What the sources say
- Not checked — no full text of the sourcecites [10] Clerc, M., Daucé, E., and Mattout, J. (2016). Adaptive Methods in Machine Learning, John Wiley & Sons. source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
15 more claims
Create a free account to see all 39 claims and every source verdict.
- It may state two separate claims as one. 12
- Probably not a substantial claim. 9
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“xDAWN spatial filtering [13] with Riemannian geometry (xDAWN+RG) features also perform well cross-subject [14], [15] but lack obvious physiological interpretation [8].”
From ERP-XTTN: interpretable prototype-guided cross-attention for cross-subject ERP classification (2026) · cites this paper as [14]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Transfer Learning Algorithm of P300-EEG Signal Based on XDAWN Spatial Filter and Riemannian Geometry Classifier
“The EEG signal containing the P300 component is expressed as X ∈ Rn×d, where n represents the feature dimension and d represents the number of channels of the EEG signal.”
§ Transfer Learning Algorithm of P300-EEG Signal Based on XDAWN Spatial Filter and Riemannian Geometry Classifier
“We need to find the projections W ∈ Rn× f ,where f represents the number of filters for projection. The data filtered by this filter are ˜ X = XW .”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Transfer Learning Algorithm of P300-EEG Signal Based on XDAWN Spatial Filter and Riemannian Geometry Classifier
“Therefore, the signal can be given by X = DT A + N, and the enhanced P300 signal we try to find can be expressed as XW = DAW + NW .”
§ Transfer Learning Algorithm of P300-EEG Signal Based on XDAWN Spatial Filter and Riemannian Geometry Classifier
“The position of the P300 component in the P300 signal can be given by D ∈ Re×n through the Toeplitz matrix.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ ∑
“We trained k classifiers for k subjects (one subject for one classifier), and the final result was voted by all classifiers, that is, the result receiving the largest number of votes.”
§ ∑
“1. Leave one subject’s data Xi (i = 1, 2, . . . k ) for testing purpose. 2. for s in k-1:”
Citations
Cites
Pan, S. J., & Yang, Q. (2010) · IEEE Transactions on Knowledge and Data Engineering · doi:10.1109/tkde.2009.191 · Cited by 23,387 · cited 1×
“In the field of machine learning, transfer learning is defined as the ability to use the knowledge learned in a previous task or domain in a new task or domain [12].”
BackgroundBreiman, L. (1996) · Machine Learning · doi:10.1007/bf00058655 · Cited by 16,325 · cited 1×
“BA method was proposed by Breiman et al. [30] and is often used in BCI [31,32].”
MethodUpdating P300: An integrative theory of P3a and P3b
Polich, J. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.04.019 · Cited by 7,919 · cited 1×
“Many different types of EEG signals can be used in BCI field, such as steady state visual evoked potential (SSVEP) [5], motor imagery (MI) [6], and P300 [7].”
BackgroundAUC: A misleading measure of the performance of predictive distribution models
Lobo, J. M., Jiménez‐Valverde, A., & Real, R. (2008) · Global Ecology and Biogeography · doi:10.1111/j.1466-8238.2007.00358.x · Cited by 3,499 · cited 1×
“Due to the unbalance of the samples classes, we used the area under the receiver operating characteristic curve (AUC) [33] as our performance metric.”
MethodNeuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 1×
“Therefore, BCI has a wide range of uses in patients with disabilities, such as patients with severe neuromuscular disease or interlocking symptoms [3,4].”
BackgroundFarwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
BCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024
A review of classification algorithms for EEG-based brain–computer interfaces: A 10 year update
Lotte, F., Bougrain, L., Cichocki, A., Clerc, M., Congedo, M., Rakotomamonjy, A., & Yger, F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab2f2 · Cited by 2,239 · cited 1×
“If the data dimension is too large, the Riemannian Geometry method will perform many calculations, which is time-consuming and causes statistical deviations [22].”
MethodMotor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990 · cited 1×
“Many different types of EEG signals can be used in BCI field, such as steady state visual evoked potential (SSVEP) [5], motor imagery (MI) [6], and P300 [7].”
BackgroundOptimization Algorithms on Matrix Manifolds
Absil, P.-A., Mahony, R., & Sepulchre, R. (2008) · Princeton University Press eBooks · doi:10.1515/9781400830244 · Cited by 1,840
An EEG-based brain-computer interface for cursor control
Wolpaw, J. R., McFarland, D. J., Neat, G. W., & Forneris, C. A. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90040-b · Cited by 1,114 · cited 1×
“For example, users can control the mouse on the screen to move left and right by imagining their left and right hand movements, respectively [2].”
BackgroundFrequency recognition based on canonical correlation analysis for SSVEP-based BCIs
Lin, Z., Zhang, C., Wu, W., & Gao, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889197 · Cited by 867
A comparison of classification techniques for the P300 Speller
Krusienski, D. J., Sellers, E. W., Cabestaing, F., Bayoudh, S., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/007 · Cited by 762 · cited 6×
“Stepwise Linear Discriminant Analysis (SWLDA) [34] and Ensemble of Support Vector Machines (E-SVM) [35] are state-of-the-art classifiers in the current statistical classifiers used in BCI.”
BackgroundInfluentialFrequency Recognition Based on Canonical Correlation Analysis for SSVEP-Based BCIs
Lin, Z., Zhang, C., Wu, W., & Gao, X. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886577 · Cited by 724 · cited 1×
“Many different types of EEG signals can be used in BCI field, such as steady state visual evoked potential (SSVEP) [5], motor imagery (MI) [6], and P300 [7].”
BackgroundNeurophysiological predictor of SMR-based BCI performance
Blankertz, B., Sannelli, C., Halder, S., Hammer, E. M., Kübler, A., Müller, K.-R., Curio, G., & Dickhaus, T. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.022 · Cited by 674 · cited 1×
“One of the main reasons hindering the widespread use of BCI systems is the variability of EEG signals [1,9].”
BackgroundxDAWN Algorithm to Enhance Evoked Potentials: Application to Brain–Computer Interface
Rivet, B., Souloumiac, A., Attina, V., & Gibert, G. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2012869 · Cited by 537 · cited 3×
“XDAWN spatial filters, specially design for Event Related Potentials (ERP), were proposed by Bertrand Rivet [23].”
BackgroundMethodInfluentialBCI competition III: Dataset II—Ensemble of SVMs for BCI P300 speller
Rakotomamonjy, A., & Guigue, V. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.915728 · Cited by 512 · cited 1×
“Stepwise Linear Discriminant Analysis (SWLDA) [34] and Ensemble of Support Vector Machines (E-SVM) [35] are state-of-the-art classifiers in the current statistical classifiers used in BCI.”
Classification of covariance matrices using a Riemannian-based kernel for BCI applications
Barachant, A., Bonnet, S., Congedo, M., & Jutten, C. (2013) · Neurocomputing · doi:10.1016/j.neucom.2012.12.039 · Cited by 493
Riemannian geometry for EEG-based brain-computer interfaces; a primer and a review
Congedo, M., Barachant, A., & Bhatia, R. (2017) · Brain-Computer Interfaces · doi:10.1080/2326263x.2017.1297192 · Cited by 456
Lin, T., & Zha, H. (2008) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2007.70735 · Cited by 446 · cited 1×
“Moreover, the Riemannian distance of the SPD matrix is invariant to the matrix inversion and any linearly invertible transformation of the matrix [36].”
BackgroundRiemannian Approaches in Brain-Computer Interfaces: A Review
Yger, F., Berar, M., & Lotte, F. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2627016 · Cited by 420 · cited 1×
“However, one of the methods with the most potential is Riemannian Geometry method [19–21].”
MethodTransfer Learning: A Riemannian Geometry framework with applications to Brain-Computer Interfaces
Zanini, P., Congedo, M., Jutten, C., Said, S., & Berthoumieu, Y. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2742541 · Cited by 412 · cited 1×
“However, one of the methods with the most potential is Riemannian Geometry method [19–21].”
MethodLotte, F. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2404941 · Cited by 327 · cited 2×
“Some other transfer learning methods are semi-supervised learning [17] and using uniform local binary patterns [18] or artificial data generation [11].”
BackgroundMethodGeneralized digital Butterworth filter design
Selesnick, I. W., & Burrus, C. S. (1998) · IEEE Transactions on Signal Processing · doi:10.1109/78.678493 · Cited by 314
Brain–computer-interface research: Coming of age
Birbaumer, N. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.11.002 · Cited by 237 · cited 1×
“Therefore, BCI has a wide range of uses in patients with disabilities, such as patients with severe neuromuscular disease or interlocking symptoms [3,4].”
BackgroundStructured optimal graph based sparse feature extraction for semi-supervised learning
Liu, Z., Lai, Z., Ou, W., Zhang, K., & Zheng, R. (2020) · Signal Processing · doi:10.1016/j.sigpro.2020.107456 · Cited by 143
An experimental evaluation of ensemble methods for EEG signal classification
Sun, S., Zhang, C., & Zhang, D. (2007) · Pattern Recognition Letters · doi:10.1016/j.patrec.2007.06.018 · Cited by 130
Self-citationLearning a common dictionary for subject-transfer decoding with resting calibration
Morioka, H., Kanemura, A., Hirayama, J.-I., Shikauchi, M., Ogawa, T., Ikeda, S., Kawanabe, M., & Ishii, S. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.02.015 · Cited by 127 · cited 1×
“Morioka et al. [16] proposed to learn a dictionary of spatial filters.”
BackgroundUnsupervised Brain Computer Interface Based on Intersubject Information and Online Adaptation
Lu, S., Guan, C., & Zhang, H. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2015197 · Cited by 122 · cited 1×
“[15] proposed an adaptive classification method.”
Aspect based sentiment analysis by a linguistically regularized CNN with gated mechanism
Zeng, D., Dai, Y., Li, F., Wang, J., & Sangaiah, A. K. (2019) · Journal of Intelligent & Fuzzy Systems · doi:10.3233/jifs-169958 · Cited by 119 · cited 1×
“We aim to mix our algorithm with some other algorithms [37–39] in future work.”
MethodSelf-citationTrue Zero-Training Brain-Computer Interfacing – An Online Study
Kindermans, P.-J., Schreuder, M., Schrauwen, B., Müller, K.-R., & Tangermann, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0102504 · Cited by 83 · cited 1×
“[13] proposed combining a Bayesian model and learning from label proportion (LLP).”
MethodA convolutional neural network-based linguistic steganalysis for synonym substitution steganography
Xiang, L., Guo, G., Yu, J., Sheng, V. S., Yang, P., & 5 Hunan Branch of CNCERT/CC, C. 4. (2019) · Mathematical Biosciences & Engineering · doi:10.3934/mbe.2020055 · Cited by 73 · cited 1×
“We aim to mix our algorithm with some other algorithms [37–39] in future work.”
MethodAn automatic segmentation and classification framework for anti-nuclear antibody images
Cheng, C.-C., Hsieh, T., Taur, J. S., & Chen, Y.-F. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-s1-s5 · Cited by 72
A subject-independent brain-computer interface based on smoothed, second-order baselining
Reuderink, B., Farquhar, J., Poel, M., & Nijholt, A. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6091139 · Cited by 54
Detecting seam carved images using uniform local binary patterns
Zhang, D., Yang, G., Li, F., Wang, J., & Sangaiah, A. K. (2018) · Multimedia Tools and Applications · doi:10.1007/s11042-018-6470-y · Cited by 35 · cited 1×
“Some other transfer learning methods are semi-supervised learning [17] and using uniform local binary patterns [18] or artificial data generation [11].”
BackgroundSelf-citationLi, Y., & Guan, C. (2006) · doi:10.1109/iembs.2006.260327 · Cited by 16 · cited 1×
“Some other transfer learning methods are semi-supervised learning [17] and using uniform local binary patterns [18] or artificial data generation [11].”
BackgroundAdaptive Methods in Machine Learning
Clerc, M., Daucé, E., & Mattout, J. (2016) · Brain–Computer Interfaces 1 · doi:10.1002/9781119144977.ch10 · Cited by 12 · cited 1×
“Due to the variability, the feature space distribution of the EEG signal collected from different subjects or different sessions are inconsistent [10].”
BackgroundOptimal Transport Applied To Transfer Learning For P300 Detection
Gayraud, N. T. H., Rakotomamonjy, A., & Clerc, M. (2017) · Verlag der Technischen Universität Graz · doi:10.3217/978-3-85125-533-1-28 · cited 1×
“[14] completed a cross-session transfer of P300 data using a nonlinear transform obtained by solving an optimal transport problem and reached the highest AUC score of 0.”
MethodGeneralized digital Butterworth filter design
Selesnick, I. W., & Burrus, C. S. (n.d.) · 1996 IEEE International Conference on Acoustics, Speech, and Signal Processing Conference Proceedings · doi:10.1109/icassp.1996.543681
Research works printed but not linked: 3
- Clerc, 2013, Brain Computer Interfaces, Principles and Practise, Biomed. Eng. Online, 12, 1
- Lang, S. (2012). Differential and Riemannian Manifolds, Springer.
- Blankertz, B., Dornhege, G., Müller, K.R., Schalk, G., Krusienski, D., Wolpaw, J.R., Schlogl, A., Graimann, B., Pfurtscheller, G., and Chiappa, S. (2005). Results of the BCI Competition III. BCI Meeting, Elsevier.
Cited by
A review on transfer learning in EEG signal analysis
Wan, Z., Yang, R., Huang, M., Zeng, N., & Liu, X. (2021) · Neurocomputing · doi:10.1016/j.neucom.2020.09.017 · Cited by 468
Review of brain encoding and decoding mechanisms for EEG-based brain–computer interface
Xu, L., Xu, M., Jung, T., & Ming, D. (2021) · Cognitive Neurodynamics · doi:10.1007/s11571-021-09676-z · Cited by 110
“Li et al. (2020) validated the xDAWN algorithm combined with Riemannian whitening for P300 datasets.”
MethodThe classification of EEG-based wink signals: A CWT-Transfer Learning pipeline
Kumar, J. L. M., Rashid, M., Musa, R. M., et al. (2021) · ICT Express · doi:10.1016/j.icte.2021.01.004 · Cited by 43
CNN With Large Data Achieves True Zero-Training in Online P300 Brain-Computer Interface
Lee, J., Won, K., Kwon, M., Jun, S. C., & Ahn, M. (2020) · IEEE Access · doi:10.1109/access.2020.2988057 · Cited by 44
“The low performance of SWLDA_ZT is in accordance with previous studies which also used SWLDA_ZT as a baseline to compare with [63].”
ResultMoctezuma, L. A., & Molinas, M. (2020) · Scientific Reports · doi:10.1038/s41598-020-72051-1 · Cited by 40
Metadata
- Authors
- Li, F., Xia, Y., Wang, F., Zhang, D., Li, X., & He, F.
- Affiliations
- Changsha University of Science and Technology (CN)
- South China Normal University (CN)
- Corresponding author
- Wang, Fei
- Venue
- Applied Sciences
- Publisher
- MDPI AG
- Published
- 2020-03-05
- Volume
- 10
- Issue
- 5
- Pages
- 1804
- ISSN
- 2076-3417 (ISSN-L)
- OpenAlex
- W3009134349
- Cited by
- 64
- References
- 38
- Citations by year
- 2026: 5 · 2025: 8 · 2024: 11 · 2023: 15 · 2022: 13 · 2021: 7 · 2020: 5
- FWCI
- 4.78
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Applied Sciences (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Natural Science Foundation of China (61906019)
- Natural Science Foundation of Hunan Province (2019JJ50649)
- Scientific Research Fund of Hunan Provincial Education Department (18C0238 and 19B004)
- "Double First-class" International Cooperation and Development Scientific Research Project of Changsha University of Science and Technology (2018IC25)
- Young Teacher Growth Plan Project of Changsha University of Science and Technology (2019QJCZ076)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
- Physical Sciences › Computer Science › Artificial Intelligence › Emotion and Mood Recognition
- Keywords
- P300, EEG, brain-computer interface, cross-subject transfer learning, P300 speller, cross-subject variability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-07, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-07 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.