CoChat

Wearable Sensors for the Detection of Biomarkers for Wound Infection

Pusta, Alexandra, Tertiș, Mihaela, Cristea, Cecilia, Mirel, Simona · 2021 · Biosensors
Cited by 80

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Infection represents a major complication that can affect wound healing in any type of wound, especially in chronic ones. There are currently certain limitations to the methods that are used for establishing a clinical diagnosis of wound infection. Thus, new, rapid and easy-to-use strategies for wound infection diagnosis need to be developed. To this aim, wearable sensors for infection diagnosis have been recently developed. These sensors are incorporated into the wound dressings that are used to treat and protect the wound, and are able to detect certain biomarkers that can be correlated with the presence of wound infection. Among these biomarkers, the most commonly used ones are pH and uric acid, but a plethora of others (lactic acid, oxygenation, inflammatory mediators, bacteria metabolites or bacteria) have also been detected using wearable sensors. In this work, an overview of the main types of wearable sensors for wound infection detection will be provided. These sensors will be divided into electrochemical, colorimetric and fluorimetric sensors and the examples will be presented and discussed comparatively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/bios12010001

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 76

  1. Siddiqui, 2010, Chronic Wound Infection: Facts and Controversies, Clin. Dermatol., 28, 519, 10.1016/j.clindermatol.2010.03.009 · DOI · Paper page
  2. Sen, 2019, Human Wounds and Its Burden: An Updated Compendium of Estimates, Adv. Wound Care, 8, 39, 10.1089/wound.2019.0946 · DOI · Paper page
  3. Cutting, 2016, The Current Burden of Infected Wounds, Br. J. Health Care Manag., 22, 436, 10.12968/bjhc.2016.22.9.436 · doi:10.12968/bjhc.2016.22.9.436
  4. Li, 2021, Diagnostics for Wound Infections, Adv. Wound Care, 10, 317, 10.1089/wound.2019.1103 · DOI · Paper page
  5. Sazonov, 2021, Grand Challenges in Wearable Electronics, Front. Electron., 2, 1, 10.3389/felec.2021.668619 · DOI
  6. Nasiri, S., and Khosravani, M.R. (2020). Progress and Challenges in Fabrication of Wearable Sensors for Health Monitoring. Sens. Actuator A Phys., 312. · DOI · Paper page
  7. Mostafalu, P., Tamayol, A., Rahimi, R., Ochoa, M., Khalilpour, A., Kiaee, G., Yazdi, I.K., Bagherifard, S., Dokmeci, M.R., and Ziaie, B. (2018). Smart Bandage for Monitoring and Treatment of Chronic Wounds. Small, 14. · DOI · Paper page
  8. Kassal, 2015, Smart Bandage with Wireless Connectivity for Uric Acid Biosensing as an Indicator of Wound Status, Electrochem. Commun., 56, 6, 10.1016/j.elecom.2015.03.018 · DOI · Paper page
  9. Rahimi, 2018, Laser-Enabled Fabrication of Flexible and Transparent pH Sensor with near-Field Communication for in-Situ Monitoring of Wound Infection, Sens. Actuators B Chem., 267, 198, 10.1016/j.snb.2018.04.004 · DOI
  10. Kassal, 2017, Smart Bandage with Wireless Connectivity for Optical Monitoring of pH, Sens. Actuators B Chem., 246, 455, 10.1016/j.snb.2017.02.095 · DOI
  11. Atkinson, 2001, Biomarkers and Surrogate Endpoints: Preferred Definitions and Conceptual Framework, Clin. Pharmacol. Ther., 69, 89, 10.1067/mcp.2001.113989 · DOI · Paper page
  12. Mota, F.A.R., Pereira, S.A.P., Araújo, A.R.T.S., Passos, M.L.C., and Saraiva, M.L.M.F.S. (2021). Biomarkers in the Diagnosis of Wounds Infection: An Analytical Perspective. TrAC-Trends Anal. Chem., 143. · DOI
  13. Galvin, 2020, ‘Smart’ Wound Dressings for Advanced Wound Care: A Review, J. Wound Care, 29, 394, 10.12968/jowc.2020.29.7.394 · DOI
  14. Brown, M.S., Ashley, B., and Koh, A. (2018). Wearable Technology for Chronic Wound Monitoring: Current Dressings, Advancements, and Future Prospects. Front. Bioeng. Biotechnol., 6. · DOI · Paper page
  15. Tegl, 2015, Biomarkers for Infection: Enzymes, Microbes, and Metabolites, Appl. Microbiol. Biotechnol., 99, 4595, 10.1007/s00253-015-6637-7 · DOI
  16. Metcalf, D.G., Haalboom, M., Bowler, P.G., Gamerith, C., Sigl, E., Heinzle, A., and Burnet, M.W.M. (2019). Elevated Wound Fluid pH Correlates with Increased Risk of Wound Infection. Wound Med., 26. · DOI
  17. Percival, 2014, The Effects of pH on Wound Healing, Biofilms, and Antimicrobial Efficacy, Wound Repair Regen., 22, 174, 10.1111/wrr.12125 · DOI · Paper page
  18. Fernandez, 2012, Elevated Uric Acid Correlates with Wound Severity, Int. Wound J., 9, 139, 10.1111/j.1742-481X.2011.00870.x · DOI · Paper page
  19. Fernandez, M.L., Upton, Z., and Shooter, G.K. (2014). Uric Acid and Xanthine Oxidoreductase in Wound Healing. Curr. Rheumatol. Rep., 16. · DOI
  20. Castilla, 2012, Oxygen: Implications for Wound Healing, Adv. Wound Care, 1, 225, 10.1089/wound.2011.0319 · DOI · Paper page
  21. Zieker, 2011, Wound Fluid Lactate Concentration: A Helpful Marker for Diagnosing Soft-Tissue Infection in Diabetic Foot Ulcers? Preliminary Findings, Diabet. Med., 28, 175, 10.1111/j.1464-5491.2010.03123.x · DOI
  22. Boykin, 2010, Wound Nitric Oxide Bioactivity, J. Wound Ostomy Cont. Nurs., 37, 25, 10.1097/WON.0b013e3181c68b61 · DOI
  23. Simoska, 2020, Electrochemical Detection of Multianalyte Biomarkers in Wound Healing Efficacy, ACS Sens., 5, 3547, 10.1021/acssensors.0c01697 · DOI
  24. Wu, K., Wu, X., Chen, M., Wu, H., Jiao, Y., and Zhou, C. (2020). H2O2-Responsive Smart Dressing for Visible H2O2 Monitoring and Accelerating Wound Healing. Chem. Eng. J., 387. · DOI
  25. Gao, Y., Nguyen, D.T., Yeo, T., Lim, S.B., Tan, W.X., Madden, L.E., Jin, L., Long, J.Y.K., Aloweni, F.A.B., and Liew, A.Y.J. (2021). A Flexible Multiplexed Immunosensor for Point-of-Care in Situ Wound Monitoring. Sci. Adv., 7. · DOI · Paper page
  26. Mannello, 2014, Omics Profiles in Chronic Venous Ulcer Wound Fluid: Innovative Applications for Translational Medicine, Expert Rev. Mol. Diagn., 14, 737, 10.1586/14737159.2014.927312 · DOI
  27. McClure, 2019, Inkjet-Printed Carbon Nanotube Electrodes for Measuring Pyocyanin and Uric Acid in a Wound Fluid Simulant and Culture Media, Anal. Chem., 91, 8835, 10.1021/acs.analchem.8b05591 · DOI
  28. Alatraktchi, F.A., Svendsen, W.E., and Molin, S. (2020). Electrochemical Detection of Pyocyanin as a Biomarker for Pseudomonas Aeruginosa: A Focused Review. Sensors, 20. · DOI · Paper page
  29. Worsfold, P., Poole, C., Townshend, A., and Miró, M.B.T.-E. (2019). Amperometry. Encyclopedia of Analytical Science, Academic Press. [3rd ed.].
  30. Liu, 2017, Embroidered Electrochemical Sensors on Gauze for Rapid Quantification of Wound Biomarkers, Biosens. Bioelectron., 98, 189, 10.1016/j.bios.2017.06.053 · DOI
  31. Pal, 2018, Early Detection and Monitoring of Chronic Wounds Using Low-Cost, Omniphobic Paper-Based Smart Bandages, Biosens. Bioelectron., 117, 696, 10.1016/j.bios.2018.06.060 · DOI · Paper page
  32. Sharifuzzaman, M., Chhetry, A., Zahed, M.A., Yoon, S.H., Park, C.I., Zhang, S., Chandra Barman, S., Sharma, S., Yoon, H., and Park, J.Y. (2020). Smart Bandage with Integrated Multifunctional Sensors Based on MXene-Functionalized Porous Graphene Scaffold for Chronic Wound Care Management. Biosens. Bioelectron., 169. · DOI
  33. Ashley, 2019, Skin-Inspired, Open Mesh Electrochemical Sensors for Lactate and Oxygen Monitoring, Biosens. Bioelectron., 132, 343, 10.1016/j.bios.2019.02.041 · DOI · Paper page
  34. Da Roz, A.L., Ferreira, M., Leite, F.d.L., and Oliveira, O.N. (2017). Electrochemical Sensors. Nanoscience and Its Applications, Elsevier. [1st ed.].
  35. Farghaly, 2014, Analytical Application Using Modern Electrochemical Techniques, Int. J. Electrochem. Sci., 9, 3287, 10.1016/S1452-3981(23)08010-0 · doi:10.1016/s1452-3981(23)08010-0
  36. Manjakkal, 2018, Printed Flexible Electrochemical pH Sensors Based on CuO Nanorods, Sens. Actuators B Chem., 263, 50, 10.1016/j.snb.2018.02.092 · DOI
  37. Pan, 2019, Color-Changing Smart Fibrous Materials for Naked Eye Real-Time Monitoring of Wound pH, J. Mater. Chem. B, 7, 2626, 10.1039/C9TB00195F · DOI
  38. Zhou, 2018, Bacteria-Responsive Intelligent Wound Dressing: Simultaneous In Situ Detection and Inhibition of Bacterial Infection for Accelerated Wound Healing, Biomaterials, 161, 11, 10.1016/j.biomaterials.2018.01.024 · DOI · Paper page
  39. Ochoa, M., Rahimi, R., Zhou, J., Jiang, H., Yoon, C.K., Maddipatla, D., Narakathu, B.B., Jain, V., Oscai, M.M., and Morken, T.J. (2020). Integrated Sensing and Delivery of Oxygen for Next-Generation Smart Wound Dressings. Microsyst. Nanoeng., 6. · DOI
  40. Hulanicki, 1991, Chemical Sensors Definitions and Classification, Pure Appl. Chem., 63, 1247, 10.1351/pac199163091247 · DOI · Paper page
  41. Romanholo, P.V.V., Razzino, C.A., Raymundo-Pereira, P.A., Prado, T.M., Machado, S.A.S., and Sgobbi, L.F. (2021). Biomimetic Electrochemical Sensors: New Horizons and Challenges in Biosensing Applications. Biosens. Bioelectron., 185. · DOI
  42. Egbuna, C., Patrick-Iwuanyanwu, K., Shah, M.A., Ifemeje, J., and Rasul, A. (2022). Biosensors: Components, Mechanisms, and Applications. Analytical Techniques in Bioscience, Elsevier.
  43. Justino, 2010, Review of Analytical Figures of Merit of Sensors and Biosensors in Clinical Applications, TrAC-Trends Anal. Chem., 29, 1172, 10.1016/j.trac.2010.07.008 · DOI
  44. Baig, 2019, Recent Trends in Nanomaterial-Modified Electrodes for Electroanalytical Applications, TrAC-Trends Anal. Chem., 111, 47, 10.1016/j.trac.2018.11.044 · DOI · Paper page
  45. Kumar, N., Shetti, N.P., Jagannath, S., and Aminabhavi, T.M. (2022). Electrochemical Sensors for the Detection of SARS-CoV-2 Virus. Chem. Eng. J., 430. · DOI · Paper page
  46. Maduraiveeran, 2018, Electrochemical Sensor and Biosensor Platforms Based on Advanced Nanomaterials for Biological and Biomedical Applications, Biosens. Bioelectron., 103, 113, 10.1016/j.bios.2017.12.031 · DOI · Paper page
  47. Ozoemena, 2017, Biomedical Electrochemical Sensors for Resource-Limited Countries, Curr. Opin. Electrochem., 3, 51, 10.1016/j.coelec.2017.06.002 · DOI
  48. Cheng, 2007, Screen-Printed Electrochemical (Bio)Sensors in Biomedical, Environmental and Industrial Applications, Comprehensive Analytical Chemistry, Volume 49, 497
  49. Williams, 2020, Electrochemical Sensors for Environmental Gas Analysis, Curr. Opin. Electrochem., 22, 145, 10.1016/j.coelec.2020.06.006 · doi:10.1016/j.coelec.2020.06.006
  50. Gan, 2019, Understanding Signal Amplification Strategies of Nanostructured Electrochemical Sensors for Environmental Pollutants, Curr. Opin. Electrochem., 17, 56, 10.1016/j.coelec.2019.04.016 · DOI
  51. Du, H., Xie, Y., and Wang, J. (2021). Nanomaterial-Sensors for Herbicides Detection Using Electrochemical Techniques and Prospect Applications. TrAC-Trends Anal. Chem., 135. · DOI
  52. Ananda Murthy, H.C., Gebremedhn Kelele, K., Ravikumar, C.R., Nagaswarupa, H.P., Tadesse, A., and Desalegn, T. (2021). Graphene-Supported Nanomaterials as Electrochemical Sensors: A Mini Review. Results Chem., 3. · DOI
  53. Si, 2020, Carbon Nanomaterials and Metallic Nanoparticles-Incorporated Electrochemical Sensors for Small Metabolites: Detection Methodologies and Applications, Curr. Opin. Electrochem., 22, 234, 10.1016/j.coelec.2020.08.007 · DOI
  54. Naresh, V., and Lee, N. (2021). A Review on Biosensors and Recent Development of Nanostructured Materials-Enabled Biosensors. Sensors, 21. · DOI · Paper page
  55. Zhu, 2015, Electrochemical Sensors and Biosensors Based on Nanomaterials and Nanostructures, Anal. Chem., 87, 230, 10.1021/ac5039863 · DOI · Paper page
  56. Li, 2019, Materials, structures, and functions for flexible and stretchable biomimetic sensors, Acc. Chem. Res., 52, 288, 10.1021/acs.accounts.8b00497 · DOI · Paper page
  57. 2018, Nanomaterial-based devices for point-of-care diagnostic applications, Chem. Soc. Rev., 47, 4697, 10.1039/C7CS00837F · DOI · Paper page
  58. Wu, 2019, Challenges and solutions in developing ultrasensitive biosensors, J. Am. Chem. Soc., 141, 1162, 10.1021/jacs.8b09397 · DOI · Paper page
  59. Bahadir, 2016, Applications of Graphene in Electrochemical Sensing and Biosensing, TrAC-Trends Anal. Chem., 76, 1, 10.1016/j.trac.2015.07.008 · doi:10.1016/j.trac.2015.07.008
  60. Nag, 2017, Graphene and Its Sensor-Based Applications: A Review, Sens. Actuators A, 270, 177, 10.1016/j.sna.2017.12.028 · DOI · Paper page
  61. Brownson, 2010, Graphene Electrochemistry: An Overview of Potential Applications, Analyst, 135, 2768, 10.1039/c0an00590h · DOI · Paper page
  62. Gupta, 2018, Recent Advances in Carbon Nanotube Based Electrochemical Biosensors, Int. J. Biol. Macromol., 108, 687, 10.1016/j.ijbiomac.2017.12.038 · DOI · Paper page
  63. Gogotsi, 2019, The Rise of MXenes, ACS Nano, 13, 8491, 10.1021/acsnano.9b06394 · DOI · Paper page
  64. Rahimi, 2017, Highly Stretchable Potentiometric pH Sensor Fabricated via Laser Carbonization and Machining of Carbon−Polyaniline Composite, ACS Appl. Mater. Interfaces, 9, 9015, 10.1021/acsami.6b16228 · DOI · Paper page
  65. Farooqui, M.F., and Shamim, A. (2016). Low Cost Inkjet Printed Smart Bandage for Wireless Monitoring of Chronic Wounds. Sci. Rep., 6. · DOI · Paper page
  66. Barber, R., Cameron, S., Devine, A., McCombe, A., Pourshahidi, L.K., Cundell, J., Roy, S., Mathur, A., Casimero, C., and Papakonstantinou, P. (2021). Laser Induced Graphene Sensors for Assessing pH: Application to Wound Management. Electrochem. Commun., 123. · doi:10.1016/j.elecom.2020.106914
  67. He, M., Ou, F., Wu, Y., Sun, X., Chen, X., Li, H., Sun, D., and Zhang, L. (2020). Smart Multi-Layer PVA Foam/ CMC Mesh Dressing with Integrated Multi-Functions for Wound Management and Infection Monitoring. Mater. Des., 194. · DOI
  68. Mazzara, F., Patella, B., Aiello, G., O’Riordan, A., Torino, C., Vilasi, A., and Inguanta, R. (2021). Electrochemical Detection of Uric Acid and Ascorbic Acid Using R-GO/NPs Based Sensors. Electrochim. Acta, 388. · DOI · Paper page
  69. Zhang, 2014, CuO Nanostructures: Synthesis, Characterization, Growth Mechanisms, Fundamental Properties, and Applications, Prog. Mater. Sci., 60, 208, 10.1016/j.pmatsci.2013.09.003 · DOI · Paper page
  70. Malekzad, 2017, Noble Metal Nanoparticles in Biosensors: Recent Studies and Applications, Nanotechnol. Rev., 6, 301, 10.1515/ntrev-2016-0014 · DOI · Paper page
  71. Yang, 2019, Detection Platforms for Point-of-Care Testing Based on Colorimetric, Luminescent and Magnetic Assays: A Review, Talanta, 202, 96, 10.1016/j.talanta.2019.04.054 · DOI · Paper page
  72. Piriya, 2017, Colorimetric Sensors for Rapid Detection of Various Analytes, Mater. Sci. Eng. C, 78, 1231, 10.1016/j.msec.2017.05.018 · DOI · Paper page
  73. Chen, H.Z., Zhang, M., Bhandari, B., and Yang, C.H. (2020). Novel pH-Sensitive Films Containing Curcumin and Anthocyanins to Monitor Fish Freshness. Food Hydrocoll., 100. · DOI · Paper page
  74. Li, T., Li, Z., Huang, T., and Tian, L. (2021). Carbon Quantum Dot-Based Sensors for Food Safety. Sens. Actuators A Phys., 331. · DOI
  75. Nazri, N.A.A., Azeman, N.H., Luo, Y., and A Bakar, A.A. (2021). Carbon Quantum Dots for Optical Sensor Applications: A Review. Opt. Laser Technol., 139. · DOI · Paper page
  76. Darwish, I.A., Khalil, N.Y., Bakheit, A.H., and Alzoman, N.Z. (2012). A Highly Sensitive Fluorimetric Method For Determination of Lenalidomide in Its Bulk Form and Capsules via Derivatization with Fluorescamine. Chem. Cent. J., 6. · doi:10.1186/1752-153x-6-118

Metadata

Authors
Pusta, A., Tertiș, M., Cristea, C., & Mirel, S.
Venue
Biosensors
Publisher
MDPI AG
Published
2021-12-21
Volume
12
Issue
1
Pages
1
ISSN
2079-6374
Cited by
80
References
6
Language
en
Funders
Iuliu Hatieganu University of Medicine and Pharmacy (1032/57/13.01.2021)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.