Abstract

Photoacoustics can provide a direct measurement of light absorption by microalgae depending on the photosynthesis pigment within them. In this study, we have performed photoacoustic flowmetry on living microalgae cells to measure their flow characteristics, which include flow speed, flow angle, flow direction, and, more importantly, the photoacoustic absorption spectrum, all by observing the photoacoustic Doppler power spectra during their flowing state. A supercontinuum pulsed laser with a high repetition frequency is used as the light source: through intensity modulation at a specified frequency, it can provide wavelength-selectable excitation of a photoacoustic signal centered around this frequency. Our approach can be useful to simultaneously measure the flow characteristics of microalgae and easily discriminate their different species with high accuracy in both static and dynamic states, thus facilitating the study of their cultivation and their role in our ecosystem.

Overview

CoChat Summary

TL;DR

The paper demonstrates photoacoustic Doppler flowmetry (PADF) on living microalgae using an intensity-modulated supercontinuum laser, extracting flow speed, direction, angle, and wavelength-dependent absorption from Doppler-shifted power spectra. It distinguishes Chlorella and Chrysophyta by their photoacoustic absorption spectra in both stationary and flowing states.

Key findings

  • Stationary photoacoustic absorption spectra showed green microalgae (Chlorella) with two distinct peaks at 480 nm and 680 nm, while golden-brown microalgae (Chrysophyta) showed a single broad absorption window from 500 nm to 700 nm, attributed to chlorophyll a/c and fucoxanthin (580–600 nm).
  • Increasing flow speed broadened the PSD curve while keeping the enclosing area constant; the Doppler broadening width at 2.0 mm/s was about ten times that at 0.2 mm/s, and at 2.0 mm/s the FWHM was 3.68 Hz.
  • Flow direction was determined from positive versus negative Doppler shifts around −5 Hz at 70° and 0.5 mm/s; flow angle measurements from 90° to 50° showed no net shift at 90° and an increasing net shift reaching 0.55 Hz at 50°, agreeing with the cosθ theoretical relation.
  • Dynamic PAD-shift absorption spectra at 0.5 mm/s and 70° reproduced the static absorption curves for both Chlorella and Chrysophyta, using nine wavelengths at 40 nm intervals and 50 nm bandwidth.

Methods

  • Precultured microalgae samples were grown in F/2 medium for 72 h, centrifuged at 3000 rpm for 5 min, concentrated, and loaded into a glass syringe on a computer-controlled microfluidic pump; Chlorella and Chrysophyta were selected for multiwavelength experiments, and Chlorella was used for flow-parameter demonstrations.
  • The setup used a supercontinuum fiber laser (tunable 400–840 nm, 80 MHz repetition rate, 250 ps pulses, 92 nJ pulse energy), electro-optic intensity modulation at 2.25 MHz, a lock-in amplifier with reference set 5 Hz higher than the modulation frequency, a 2.25 MHz ultrasonic transducer perpendicular to flow, a 60 dB preamplifier, a 0.5 mm inner-diameter silicon tube, and a rotatable mount for flow angles.
  • Power spectral density was calculated as the squared magnitude of the FFT normalized by effective noise bandwidth with a Hamming window; Gaussian fitting via the Levenberg–Marquardt algorithm extracted area, width, center, and FWHM, using 2300 data points, 145 s per measurement, 15.0 Hz spectral range, and 6.862 mHz resolution.

Limitations

  • The paper states that flow speeds above 2.0 mm/s may require a higher frequency offset, and that at high flow speeds the noise ratio increases while signal amplitude decreases with spectral broadening, so flow speed measurement may not be very accurate above 2.0 mm/s; parameters were optimized for 0.1–1 mm/s.
  • The paper states that flow-angle measurements were limited to 50° and above because the photoacoustic signal became weak or blocked below 50°, and that dynamic absorption spectra used a 40 nm wavelength interval, with finer 10 nm resolution being time-consuming; the ideal flow speed and angle were 0.5 mm/s and 70°, with other settings potentially reducing spectral accuracy due to lower SNR.
  • The paper states that background acoustic signal was detected even without laser light, attributed to electromagnetic interference, electronic component noise, and environmental factors, and was reduced tenfold by separating electronics; evidently, multiwavelength species discrimination was demonstrated only for two selected species after initial screening of five microalgae types.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.3390/bios14080397

Cites

58 of 58 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Schematic Diagram of the Experiment. (M1, M2) Mirrors, (QWP) Quarter-Wave Plate, (TF) Tunable Filter, (EOM) Electro-Optical Modulator, (P1, P2) Glan Prisms, and (L1) Convex Lens.
Figure 1 Schematic Diagram of the Experiment. (M1, M2) Mirrors, (QWP) Quarter-Wave Plate, (TF) Tunable Filter, (EOM) Electro-Optical Modulator, (P1, P2) Glan Prisms, and (L1) Convex Lens.CC BY · PubMed Central
Figure 2 (a) Photoacoustic spectra of green algae (Chlorella) (bandwidths: black = 25 nm, red = 50 nm). (b) Photoacoustic spectra of golden-brown algae (bandwidths: black = 25 nm, red = 50 nm).
Figure 2 (a) Photoacoustic spectra of green algae (Chlorella) (bandwidths: black = 25 nm, red = 50 nm). (b) Photoacoustic spectra of golden-brown algae (bandwidths: black = 25 nm, red = 50 nm).CC BY · PubMed Central
Figure 3 Experimental PAD spectra results for horizontal flow direction and flow speed at 5 different speeds with their smoothed Gaussian approximation collectively.
Figure 3 Experimental PAD spectra results for horizontal flow direction and flow speed at 5 different speeds with their smoothed Gaussian approximation collectively.CC BY · PubMed Central
Figure 4 Experimental PAD spectra results for flow direction measurements along with their smoothed Gaussian approximation signal at 0.5 mm/s flow speed and 70° flow angle. Red: flow direction toward the ultrasonic transducer. Black: flow direction away from the ultrasonic transducer.
Figure 4 Experimental PAD spectra results for flow direction measurements along with their smoothed Gaussian approximation signal at 0.5 mm/s flow speed and 70° flow angle. Red: flow direction toward the ultrasonic transducer. Black: flow direction away from the ultrasonic transducer.CC BY · PubMed Central
Figure 5 (a) Experimental PAD spectra results for flow angle measurements at different angles with their smoothed Gaussian approximation signal. (b) Mean PAD shift calculated from power spectra (red dots) compared with theoretical values (black curve) at different angles.
Figure 5 (a) Experimental PAD spectra results for flow angle measurements at different angles with their smoothed Gaussian approximation signal. (b) Mean PAD shift calculated from power spectra (red dots) compared with theoretical values (black curve) at different angles.CC BY · PubMed Central
Figure 6 (a) Experimental PAD spectra results for green algae at different wavelengths (constant speed, angle, and direction). (b) Normalized plot of photoacoustic absorption spectrum in stationary position (black line) and photoacoustic absorption spectrum in flow by estimating area under curve of PAD spectrum (red circles).
Figure 6 (a) Experimental PAD spectra results for green algae at different wavelengths (constant speed, angle, and direction). (b) Normalized plot of photoacoustic absorption spectrum in stationary position (black line) and photoacoustic absorption spectrum in flow by estimating area under curve of PAD spectrum (red circles).CC BY · PubMed Central
Figure 7 (a) Experimental photoacoustic Doppler spectra results for golden-brown algae at different wavelengths (constant speed, angle, and direction). (b) Normalized plot of photoacoustic absorption spectrum in stationary position (black line) and photoacoustic absorption spectrum in flow by estimating area under curve of PAD spectrum (red circles).
Figure 7 (a) Experimental photoacoustic Doppler spectra results for golden-brown algae at different wavelengths (constant speed, angle, and direction). (b) Normalized plot of photoacoustic absorption spectrum in stationary position (black line) and photoacoustic absorption spectrum in flow by estimating area under curve of PAD spectrum (red circles).CC BY · PubMed Central

Verification

Claims the paper makes

6 Valid · 1 Not valid · 10 Not checked · 57 Own results and interpretations

37 more claims

Create a free account to see all 74 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 13
  • It may state two separate claims as one. 24

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

2 of 2

Citations

Cites

Research works printed but not linked: 1

  1. Oraevsky, A.A., and Wang, L.V. (2008, January 7). Photoacoustic Doppler Flowmetry. Proceedings of the SPIE BiOS, San Francisco, CA, USA.

Cited by

See all 1

Metadata

Authors
Farooq, T., Wu, X., Yan, S., & Fang, H.
Affiliations
  • Shenzhen University (CN)
  • Nanophotonic Research Center, Shenzhen Key Laboratory of Micro-Scale Optical Information Technology, Institute of Microscale Optoelectronics, Shenzhen 518060, China
Corresponding author
  • Yan, Sheng
  • Fang, Hui
Venue
Biosensors
Publisher
MDPI AG
Published
2024-08-16
Volume
14
Issue
8
Pages
397
ISSN
2079-6374 (ISSN-L)
OpenAlex
W4401634253
Cited by
1
References
58
Citations by year
2025: 1
FWCI
0.11
Type
journal article
Language
en
Open access
Locations
  • Biosensors (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
  • National Natural Science Foundation of China (12074268, 2023YQ024)
  • Scientific Instrument Developing Project of Shenzhen University (12074268, 2023YQ024)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Photoacoustic and Ultrasonic Imaging
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
Keywords
microalgae, flow velocity measurement, flow direction, species discrimination, photosynthetic pigments, microalgae cultivation
MeSH terms
Photosynthesis, Microalgae, Photoacoustic Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-01, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-01 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.