Enzymatic Low Volume Passive Sweat Based Assays for Multi-Biomarker Detection
Open accessAbstract
Simultaneous detection of correlated multi-biomarkers on a single low-cost platform in ultra-low fluid volumes with robustness is in growing demand for the development of wearable diagnostics. A non-faradaic biosensor for the simultaneous detection of alcohol, glucose, and lactate utilizing low volumes (1–5 μL) of sweat is demonstrated. Biosensing is implemented using nanotextured ZnO films integrated on a flexible porous membrane to achieve enhanced sensor performance. The ZnO sensing region is functionalized with enzymes specific for the detection of alcohol, glucose, and lactate in the ranges encompassing their physiologically relevant levels. A non-faradaic chronoamperometry technique is used to measure the current changes associated with interactions of the target biomarkers with their specific enzyme. The specificity performance of the biosensing platform was established in the presence of cortisol as the non-specific molecule. Biosensing performance of the platform in a continuous mode performed over a 1.5-h duration showed a stable current response to cumulative lifestyle biomarker concentrations with capability to distinguish reliably between low, mid, and high concentration ranges of alcohol (0.1, 25, 100 mg/dL), glucose (0.1, 10, 50 mg/dL), and lactate (1, 50, 100 mM). The low detection limits and a broader dynamic range for the lifestyle biomarker detection are quantified in this research demonstrating its suitability for translation into a wearable device.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · see citing works
Limit of blank, limit of detection and limit of quantitation.
Armbruster, D., & Pry, T. (2008) · PubMed Central · doi:10.1111/aji.13807 · Cited by 2,092 · see citing works
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802 · see citing works
The Rise of Consumer Health Wearables: Promises and Barriers
Piwek, L., Ellis, D. A., Andrews, S., & Joinson, A. (2016) · PLoS Medicine · doi:10.1371/journal.pmed.1001953 · Cited by 1,301 · see citing works
Swan, M. (2012) · Journal of Sensor and Actuator Networks · doi:10.3390/jsan1030217 · Cited by 934 · see citing works
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862 · see citing works
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724 · see citing works
Lactic acidosis in critical illness
Mizock, B. A., & Falk, J. L. (1992) · Critical Care Medicine · doi:10.1097/00003246-199201000-00020 · Cited by 604 · see citing works
Noninvasive Alcohol Monitoring Using a Wearable Tattoo-Based Iontophoretic-Biosensing System
Kim, J., Jeerapan, I., Imani, S., Cho, T. N., Bandodkar, A., Cinti, S., Mercier, P. P., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00356 · Cited by 599 · see citing works
Correlation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes
Moyer, J., Wilson, D., Finkelshtein, I., Wong, B., & Potts, R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0262 · Cited by 570 · see citing works
Robinson, S., & Robinson, A. H. (1954) · Physiological Reviews · doi:10.1152/physrev.1954.34.2.202 · Cited by 514 · see citing works
A wearable multisensing patch for continuous sweat monitoring
Anastasova, S., Crewther, B., Bembnowicz, P., Curto, V., Ip, H. M., Rosa, B., & Yang, G.-Z. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.038 · Cited by 443 · see citing works
Omar, F. M., Aziz, H. B. A., & Stoll, S. (2013) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2013.08.044 · Cited by 300 · see citing works
Voltammetric techniques of analysis: the essentials
Scholz, F. (2015) · ChemTexts · doi:10.1007/s40828-015-0016-y · Cited by 233 · see citing works
Munje, R. D., Muthukumar, S., & Prasad, S. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.07.088 · Cited by 190 · see citing works
Self-citationRelationship between Lactate Concentrations in Active Muscle Sweat and Whole Blood
Sakharov, D. A., Shkurnikov, M. Y., Vagin, M. Y., Yashina, E. I., Karyakin, A. A., & Tonevitsky, A. (2010) · Bulletin of Experimental Biology and Medicine · doi:10.1007/s10517-010-1075-0 · Cited by 155 · see citing works
Gamella, M., Campuzano, S., Manso, J., Rivera, G. G. D., López-Colino, F., Reviejo, A. J., & Pingarrón, J. M. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.09.020 · Cited by 140 · see citing works
Flexible nanoporous tunable electrical double layer biosensors for sweat diagnostics
Munje, R. D., Muthukumar, S., Panneer Selvam, A., & Prasad, S. (2015) · Scientific Reports · doi:10.1038/srep14586 · Cited by 138 · see citing works
Self-citationConsequences of alcohol use in diabetics.
Emanuele, N. V., Swade, T. F., & Emanuele, M. A. (1998) · Europe PMC (PubMed Central) · Cited by 103 · see citing works
TiCxOy thin films for decorative applications: Tribocorrosion mechanisms and synergism
Mathew, M. T., Ariza, E., Rocha, L. A., Fernandes, A. C., & Vaz, F. (2008) · Tribology International · doi:10.1016/j.triboint.2007.11.011 · Cited by 101 · see citing works
Brunner, R., Adelsmayr, G., Herkner, H., Madl, C., & Holzinger, U. (2012) · Critical Care · doi:10.1186/cc11657 · Cited by 101 · see citing works
Simultaneous lancet-free monitoring of alcohol and glucose from low-volumes of perspired human sweat
Bhide, A., Muthukumar, S., Saini, A., & Prasad, S. (2018) · Scientific Reports · doi:10.1038/s41598-018-24543-4 · Cited by 76 · see citing works
Self-citationHeinonen, S., Nikkanen, J., Huttunen‐Saarivirta, E., et al. (2017) · Thin Solid Films · doi:10.1016/j.tsf.2017.07.055 · Cited by 46 · see citing works
Du, X., Anzai, J., Osa, T., et al. (1996) · Electroanalysis · doi:10.1002/elan.1140080820 · Cited by 31 · see citing works
Palanisamy, S., Devasenathipathy, R., Chen, S., et al. (2015) · Electroanalysis · doi:10.1002/elan.201500150 · Cited by 26 · see citing works
Alcohol, diabetes, and public health in the Americas
Babor, T. F., Rehm, J. T., Jernigan, D. H., Vaeth, P. A. C., Monteiro, M. G., & Lehman, H. (2012) · Revista Panamericana de Salud Pública · doi:10.1590/s1020-49892012000800010 · Cited by 26 · see citing works
Can composite digital monitoring biomarkers come of age? A framework for utilization
Kovalchick, C., Sirkar, R., Regele, O. B., Kourtis, L. C., Schiller, M., Wolpert, H. A., Alden, R. G., Jones, G. B., & Wright, J. M. (2017) · Journal of Clinical and Translational Science · doi:10.1017/cts.2018.4 · Cited by 15 · see citing works
Impact of blood glucose on blood lactate levels in a medical ICU: a retrospective cohort study
Adelsmayr, G., Brunner, R., & Holzinger, U. (2012) · Critical Care · doi:10.1186/cc10772 · Cited by 9 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Li, G., & Wen, D. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02474c · Cited by 119 · see citing works
Shajari, S., Salahandish, R., Zare, A., Hassani, M., Moossavi, S., Munro, E., Rashid, R., Rosenegger, D., Bains, J. S., & Sanati Nezhad, A. (2023) · Advanced Science · doi:10.1002/advs.202204171 · Cited by 55 · see citing works
- Authors
- Bhide, A., Cheeran, S., Muthukumar, S., & Prasad, S.
- Affiliations
- The University of Texas at Dallas (US)
- Enlisense LLC, 1813 Audubon Pond way, Allen, TX 75013, USA
- Corresponding author
- Prasad, Shalini
- Venue
- Biosensors
- Publisher
- MDPI AG
- Published
- 2019-01-16
- Volume
- 9
- Issue
- 1
- Pages
- 13
- ISSN
- 2079-6374 (ISSN-L)
- PMC
- PMC6468720
- OpenAlex
- W2909303227
- Cited by
- 30
- References
- 28
- Citations by year
- 2026: 2 · 2024: 2 · 2023: 2 · 2022: 8 · 2021: 10 · 2020: 5 · 2019: 1
- FWCI
- 2.16
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Biosensors (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Institutes of Health (R43AA026114)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- chronoamperometry, alcohol detection, glucose detection, lactate detection, wearable diagnostics
- MeSH terms
- Wearable Electronic Devices, Alcohols, Eccrine Glands, Glucose, Humans, Hydrogen-Ion Concentration, Sweat, Zinc Oxide, Biosensing Techniques, Biomarkers, Lactic Acid, Enzyme Assays, Limit of Detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review