Microbial Fuel Cell-Based Biosensors
Open accessThe DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Abstract
The microbial fuel cell (MFC) is a promising environmental biotechnology that has been proposed mainly for power production and wastewater treatment. Though small power output constrains its application for directly operating most electrical devices, great progress in its chemical, electrochemical, and microbiological aspects has expanded the applications of MFCs into other areas such as the generation of chemicals (e.g., formate or methane), bioremediation of contaminated soils, water desalination, and biosensors. In recent decades, MFC-based biosensors have drawn increasing attention because of their simplicity and sustainability, with applications ranging from the monitoring of water quality (e.g., biochemical oxygen demand (BOD), toxicants) to the detection of air quality (e.g., carbon monoxide, formaldehyde). In this review, we summarize the status quo of MFC-based biosensors, putting emphasis on BOD and toxicity detection. Furthermore, this review covers other applications of MFC-based biosensors, such as DO and microbial activity. Further, challenges and prospects of MFC-based biosensors are briefly discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heavy Metal Toxicity and the Environment
Tchounwou, P. B., Yedjou, C. G., Patlolla, A. K., & Sutton, D. J. (2012) · Experientia Supplementum · doi:10.1007/978-3-7643-8340-4_6 · Cited by 7,192 · cited 1×
“They would also accumulate in human body along the food chain and could cause health problems once reaching certain concentrations, despite some of them are essential for human health [82].”
BackgroundMicrobial Fuel Cells: Methodology and Technology
Logan, B. E., Hamelers, B., Rozendal, R., Schröder, U., Keller, J., Freguia, S., Aelterman, P., Verstraete, W., & Rabaey, K. (2006) · Environmental Science & Technology · doi:10.1021/es0605016 · Cited by 6,065
Petrie, B., Barden, R., & Kasprzyk-Hordern, B. (2015) · Water Research · doi:10.1016/j.watres.2014.08.053 · Cited by 2,614 · cited 1×
“The industrial revolution boosts the society development but also brings tons of different new-to-nature compounds into the water ecosystem [73].”
BackgroundGlobal Water Pollution and Human Health
Schwarzenbach, R. P., Egli, T., Hofstetter, T. B., von Gunten, U., & Wehrli, B. (2010) · Annual Review of Environment and Resources · doi:10.1146/annurev-environ-100809-125342 · Cited by 2,076
Liu, H., & Logan, B. E. (2004) · Environmental Science & Technology · doi:10.1021/es0499344 · Cited by 1,982 · cited 1×
“MFCs are devices that use microorganisms as catalyst to convert chemical energy directly into electricity [14].”
BackgroundToxicity of heavy metals to microorganisms and microbial processes in agricultural soils: a review
Giller, K. E., Witter, E., & Mcgrath, S. P. (1998) · Soil Biology and Biochemistry · doi:10.1016/s0038-0717(97)00270-8 · Cited by 1,982 · cited 1×
“Heavy metal ions can inhibit respiration activities of microorganisms [83], which is the foundation for the current output of MFCs.”
BackgroundAntibiotic Pollution in the Environment: A Review
Gothwal, R., & Shashidhar, T. (2015) · CLEAN – Soil, Air, Water · doi:10.1002/clen.201300989 · Cited by 730 · cited 1×
“Antibiotics have saved millions of people, but the improper handle and discharge of antibiotics into environment have also interfered with the natural evolution process, causing many safety issues to microbial ecosystem and subsequently human beings [91].”
BackgroundMicrobial biosensors: A review
Su, L., Jia, W., Hou, C., & Lei, Y. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.09.005 · Cited by 725 · cited 1×
“These can be overcome by whole-cell based biosensors, and thus they are often considered as future alternatives to enzymatic biosensors [12,13].”
BackgroundKim, J. R., Cheng, S., Oh, S.-E., & Logan, B. E. (2007) · Environmental Science & Technology · doi:10.1021/es062202m · Cited by 699 · cited 1×
“, Na+, K+) migrate to the cathode through the IEM to keep charge balance [16].”
BackgroundCheung, K. H., & Gu, J.-D. (2007) · International Biodeterioration & Biodegradation · doi:10.1016/j.ibiod.2006.05.002 · Cited by 679 · cited 1×
“Cr6+ can be reduced by Cr6+-reducing anaerobes under anaerobic conditions and serves as the terminal electron acceptor [85].”
BackgroundCathode Performance as a Factor in Electricity Generation in Microbial Fuel Cells
Oh, S., Min, B., & Logan, B. E. (2004) · Environmental Science & Technology · doi:10.1021/es049422p · Cited by 657 · cited 1×
“[103], with the half saturated DO value of 1.”
BackgroundEutrophication of Lake Waters in China: Cost, Causes, and Control
Le, C., Zha, Y., Li, Y., Sun, D., Lu, H., & Yin, B. (2010) · Environmental Management · doi:10.1007/s00267-010-9440-3 · Cited by 648
Advances in biosensors: Principle, architecture and applications
Perumal, V., & Hashim, U. (2014) · Journal of Applied Biomedicine · doi:10.1016/j.jab.2013.02.001 · Cited by 606 · cited 1×
“Typically, biosensors (Figure 1A) consist of biological recognition elements and physical transducers translating the biologic response into an electrical, thermal, or optical signal correlated to the analyte concentration [4].”
BackgroundChallenges and Constraints of Using Oxygen Cathodes in Microbial Fuel Cells
Zhao, F., Harnisch, F., Schröder, U., Scholz, F., Bogdanoff, P., & Herrmann, I. (2006) · Environmental Science & Technology · doi:10.1021/es060332p · Cited by 539 · cited 1×
“The cathode efficiency is a constraint for the MFC performance [102] while oxygen, as the final electron acceptor, can largely determine the cathodic reduction rate and thus the current output.”
BackgroundGlossary for chemists of terms used in biotechnology (IUPAC Recommendations 1992)
Nagel, B., Dellweg, H., & Gierasch, L. M. (1992) · Pure and Applied Chemistry · doi:10.1351/pac199264010143 · Cited by 472
Enrichment of microbial community generating electricity using a fuel-cell-type electrochemical cell
Kim, B. H., Park, H. S., Kim, H. J., Kim, G. T., Chang, I. S., Lee, J., & Phung, N. T. (2004) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-003-1412-6 · Cited by 465 · cited 1×
“The presence of other electron acceptors in the anodic chamber, such as nitrate and oxygen, was also found to reduce the current output of an MFC because they competed with anode for the electrons from biofilm [58].”
BackgroundBiosensors as useful tools for environmental analysis and monitoring
Rodriguez-Mozaz, S., Lopez de Alda, M. J., & Barceló, D. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0574-3 · Cited by 451 · cited 1×
“Due to the feasibility of portability, of working on-site and determining biological effects, biosensors have been emerging as appropriate analytical tools for environmental monitoring [3].”
Continuous determination of biochemical oxygen demand using microbial fuel cell type biosensor
Chang, I. S., Jang, J. K., Gil, G. C., Kim, M., Kim, H. J., Cho, B. W., & Kim, B. H. (2004) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00272-0 · Cited by 415 · cited 4×
“[23] addressed the effects of feeding rates in both anode and cathode on the sensor performance.”
BackgroundMethodInfluentialNovel BOD (biological oxygen demand) sensor using mediator-less microbial fuel cell
Kim, B. H., Chang, I. S., Cheol Gil, G., Park, H. S., & Kim, H. J. (2003) · Biotechnology Letters · doi:10.1023/a:1022891231369 · Cited by 394 · cited 1×
“Moreover, an MFC-based biosensor was reported to be operated over 5 years in a stable manner [50], which was much longer than that of previously reported BOD biosensors (7 to 140 d) [51].”
Microbial electrode BOD sensors
Karube, I., Matsunaga, T., Mitsuda, S., & Suzuki, S. (1977) · Biotechnology and Bioengineering · doi:10.1002/bit.260191010 · Cited by 362 · cited 1×
“[45] for the first time proposed the use of MFCs as a BOD sensor.”
MethodMicrobial Fuel Cells Generating Electricity from Rhizodeposits of Rice Plants
Schamphelaire, L. D., Bossche, L. V. D., Dang, H. S., Höfte, M., Boon, N., Rabaey, K., & Verstraete, W. (2008) · Environmental Science & Technology · doi:10.1021/es071938w · Cited by 333 · cited 1×
“In plant MFCs (PMFCs), rhizosphere microbes can generate electrical current by degrading the organic excretes of the rhizodeposits [98], so any changes of the bioavailable substrates concentration can affect the electrical current.”
BackgroundAntibody production, design and use for biosensor-based applications
Conroy, P. J., Hearty, S., Leonard, P., & O’Kennedy, R. J. (2009) · Seminars in Cell & Developmental Biology · doi:10.1016/j.semcdb.2009.01.010 · Cited by 314 · cited 1×
“According to the type of biorecognition, biosensors can be categorized as immunosensors [5], enzymatic biosensors [6], DNA biosensors [7], cell-based biosensors [8], and biomimetic biosensors [9].”
BackgroundTorres, C. I., Marcus, A. K., Parameswaran, P., & Rittmann, B. E. (2008) · Environmental Science & Technology · doi:10.1021/es800970w · Cited by 291
A single-chamber microbial fuel cell as a biosensor for wastewaters
Di Lorenzo, M., Curtis, T. P., Head, I. M., & Scott, K. (2009) · Water Research · doi:10.1016/j.watres.2009.01.005 · Cited by 286
Is microbial fuel cell technology ready? An economic answer towards industrial commercialization
Trapero, J. R., Horcajada, L., Linares, J. J., & Lobato, J. (2017) · Applied Energy · doi:10.1016/j.apenergy.2016.10.109 · Cited by 248 · cited 1×
“Typically, membrane and cathode (catalyst) account for the majority investment required for an MFC reactor [67].”
BackgroundA small-scale air-cathode microbial fuel cell for on-line monitoring of water quality
Di Lorenzo, M., Thomson, A. R., Schneider, K., Cameron, P. J., & Ieropoulos, I. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.06.050 · Cited by 244
How azide inhibits ATP hydrolysis by the F-ATPases
Bowler, M. W., Montgomery, M. G., Leslie, A. G. W., & Walker, J. E. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0602915103 · Cited by 244 · cited 1×
“However, they also caused “side effects” to the cellular metabolism [60,61], which could subsequently interrupt the extracellular electron transfer.”
BackgroundJiang, Y., Yang, X., Liang, P., Liu, P., & Huang, X. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.06.099 · Cited by 239 · cited 2×
“So far, the detection limit of MFC-based toxicity sensors is still far away (tens to hundreds times higher) from the water quality standard published by the World Health Organization [76].”
BackgroundMicrobial BOD sensors for wastewater analysis
Liu, J., & Mattiasson, B. (2002) · Water Research · doi:10.1016/s0043-1354(02)00101-x · Cited by 231 · cited 1×
“Moreover, an MFC-based biosensor was reported to be operated over 5 years in a stable manner [50], which was much longer than that of previously reported BOD biosensors (7 to 140 d) [51].”
Microbial Biosensors: Engineered Microorganisms as the Sensing Machinery
Park, M., Tsai, S.-L., & Chen, W. (2013) · Sensors · doi:10.3390/s130505777 · Cited by 220 · cited 1×
“These can be overcome by whole-cell based biosensors, and thus they are often considered as future alternatives to enzymatic biosensors [12,13].”
BackgroundA novel biomonitoring system using microbial fuel cells
Kim, M., Sik Hyun, M., Gadd, G. M., & Joo Kim, H. (2007) · Journal of Environmental Monitoring · doi:10.1039/b713114c · Cited by 212 · cited 4×
“[35] utilized a dual-chamber MFC to test the toxicity of diazinon (an organophosphorus compound) and PCBs, and the inhibition ratios resulting from diazinon and PCBs (1 mg/L) were 61% and 38%, respectively.”
BackgroundMethodInfluentialA screen-printed paper microbial fuel cell biosensor for detection of toxic compounds in water
Chouler, J., Cruz-Izquierdo, Á., Rengaraj, S., Scott, J. L., & Di Lorenzo, M. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.11.018 · Cited by 178 · cited 3×
“Photographs or schematics of MFC toxicity sensors: (A) membrane-based electrodes [77], (B) abiotic cathode sensing element [78], (C) miniature MFC with air bubble trap [79], (D) paper MFC [80], and (E) shared cathode [81].”
BackgroundMethodDevelopment of biosensor technologies for analysis of environmental contaminants
Wang, X., Lu, X., & Chen, J. (2014) · Trends in Environmental Analytical Chemistry · doi:10.1016/j.teac.2014.04.001 · Cited by 169 · cited 1×
“Enzymatic biosensors occupy a considerable proportion in biosensors, and they exhibit high selectivity in differentiating the target [10].”
BackgroundEnergetically autonomous robots: Food for thought
Melhuish, C., Ieropoulos, I. A., Greenman, J., & Horsfield, I. (2006) · Autonomous Robots · doi:10.1007/s10514-006-6574-5 · Cited by 164 · cited 1×
“Furthermore, they can also be designed and applied for remote areas due to their capability of self-generation of electric powers [53].”
BackgroundCell-based electrochemical biosensors for water quality assessment
Lagarde, F., & Jaffrezic-Renault, N. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-4816-7 · Cited by 164 · cited 1×
“However, they have several main limitations, such as cost-intensive approaches for enzyme purification and immobilization and short half-life time of enzymes compared to chemical catalysts [11].”
BackgroundWater Quality Monitoring in Developing Countries; Can Microbial Fuel Cells be the Answer?
Chouler, J., & Lorenzo, M. D. (2015) · Biosensors · doi:10.3390/bios5030450 · Cited by 159 · cited 1×
“The response of the anodic biofilm to the disturbance affects the electron flow rate, which is transduced into a measurable signal [19].”
BackgroundA batch-mode cube microbial fuel cell based “shock” biosensor for wastewater quality monitoring
Liu, B., Lei, Y., & Li, B. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.06.051 · Cited by 153
Yu, D., Bai, L., Zhai, J., Wang, Y., & Dong, S. (2017) · Talanta · doi:10.1016/j.talanta.2017.03.048 · Cited by 153
Comprehensive Study on Ceramic Membranes for Low‐Cost Microbial Fuel Cells
Pasternak, G., Greenman, J., & Ieropoulos, I. A. (2015) · ChemSusChem · doi:10.1002/cssc.201501320 · Cited by 142
Soldatkin, O. O., Kucherenko, I. S., Pyeshkova, V. M., Кукла, А. Л., Jaffrezic-Renault, N. J., El'skaya, A. V., Dzyadevych, S. V., & Soldatkin, A. P. (2011) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2011.08.001 · Cited by 141 · cited 1×
“According to the type of biorecognition, biosensors can be categorized as immunosensors [5], enzymatic biosensors [6], DNA biosensors [7], cell-based biosensors [8], and biomimetic biosensors [9].”
BackgroundA Current Global View of Environmental and Occupational Cancers
YANG, M. (2011) · Journal of Environmental Science and Health, Part C · doi:10.1080/10590501.2011.601848 · Cited by 141
Effect of shear rate on the response of microbial fuel cell toxicity sensor to Cu(II)
Shen, Y., Wang, M., Chang, I. S., & Ng, H. Y. (2013) · Bioresource Technology · doi:10.1016/j.biortech.2013.02.069 · Cited by 135 · cited 1×
“Cu2+ CC CC/Pt CEM 5–7 mg/L 240 min [37]”
Microbial Fuels Cell-Based Biosensor for Toxicity Detection: A Review
Zhou, T., Han, H., Liu, P., Xiong, J., Tian, F., & Li, X. (2017) · Sensors · doi:10.3390/s17102230 · Cited by 133 · cited 1×
“Finally, when oxygen acts as the electron acceptor, electrons and protons will combine with oxygen to form water [17].”
BackgroundZhang, Y., & Angelidaki, İ. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23204 · Cited by 132 · cited 1×
“microbial activity CP CP/Pt PEM 0–13 nmol/L <186 min [43]”
BackgroundMicrobial fuel cell-based biosensors for environmental monitoring: a review.
Sun, J.-Z., Kingori, G. P., Si, R.-W., Zhai, D.-D., Liao, Z.-H., Sun, D.-Z., Zheng, T., & Yong, Y.-C. (2015) · Water Science and Technology · doi:10.2166/wst.2015.035 · Cited by 128 · cited 1×
“, mine drainage, cause a sudden change of the pH [96].”
BackgroundFePO4 based single chamber air-cathode microbial fuel cell for online monitoring levofloxacin
Zeng, L., Li, X., Shi, Y., Yefei, Q., Huang, D., Tadé, M. O., Wang, S., & Liu, S. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.12.021 · Cited by 119 · cited 1×
“Another commonly used antibiotic, levofloxacin, was examined using a single-chamber MFC [38].”
MethodNovel Applications of Microbial Fuel Cells in Sensors and Biosensors
Ivars‐Barceló, F., Zuliani, A., Fallah, M., Mashkour, M., Rahimnejad, M., & Luque, R. (2018) · Applied Sciences · doi:10.3390/app8071184 · Cited by 114 · cited 2×
“Sche atic diagrams of (A) a biosensor [20], (B) a dual-chamber microbial fuel cell (MFC) and (C) an MFC-based biosensor.”
BackgroundAbrevaya, X. C., Sacco, N. J., Bonetto, M. C., Ohlsson, A. H., & Cortón, E. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.04.053 · Cited by 109 · cited 1×
“In this case, MFC was proposed to be a fast and easy method to collect the first-hand information of the microorganism and its general lifestyle [107].”
MethodBio-electrolytic sensor for rapid monitoring of volatile fatty acids in anaerobic digestion process
Jin, X., Li, X., Zhao, N., Angelidaki, İ., & Zhang, Y. (2016) · Water Research · doi:10.1016/j.watres.2016.12.045 · Cited by 107 · cited 1×
“5–2 mM N/A [30] CB TWWM/Pt AEM 5–100 mM 60–240 min [31]”
Microbial fuel cell based biosensor for in situ monitoring of anaerobic digestion process
Liu, Z., Liu, J., Zhang, S., Xing, X., & Su, Z. G. (2011) · Bioresource Technology · doi:10.1016/j.biortech.2011.08.053 · Cited by 104 · cited 1×
“[110] designed a flow-cell MFC to trace the anaerobic digestor performance, and found the current output changes correlated to variations of the operating parameters, e.”
BackgroundA novel biosensor for p-nitrophenol based on an aerobic anode microbial fuel cell
Chen, Z., Niu, Y., Zhao, S., Khan, A., Ling, Z., Chen, Y., Liu, P., & Li, X. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.06.007 · Cited by 97 · cited 7×
“[40] established a dual-chamber MFC using p-nitrophenol (PNP) as a sole substrate.”
BackgroundMethodInfluentialExploring the use of cost-effective membrane materials for Microbial Fuel Cell based sensors
Chouler, J., Bentley, I., Vaz, F., O’Fee, A., Cameron, P. J., & Lorenzo, M. D. (2017) · Electrochimica Acta · doi:10.1016/j.electacta.2017.01.195 · Cited by 95 · cited 1×
“[71]; comparable capabilities and sensitivities were obtained for the MFCs using these two membranes for BOD detections, compared to the one with an expensive Nafion membrane.”
MethodApplication of Aptamer Based Biosensor for Detection of Pathogenic Microorganism
Wang, Y., Ye, Z., Si, C., & Ying, Y. B. (2012) · Chinese Journal of Analytical Chemistry · doi:10.1016/s1872-2040(11)60542-2 · Cited by 92
Ayyaru, S., & Dharmalingam, S. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.01.059 · Cited by 91 · cited 2×
“[24] fabricated a single-chamber MFC for BOD monitoring, using a sulfonated poly ether ether ketone membrane to prepare a membrane electrode assembly.”
MethodZhao, S., Liu, P., Niu, Y., Chen, Z., Khan, A., Zhang, P., & Li, X. (2018) · Sensors · doi:10.3390/s18020642 · Cited by 82 · cited 3×
“Photographs or schematics of MFC toxicity sensors: (A) membrane-based electrodes [77], (B) abiotic cathode sensing element [78], (C) miniature MFC with air bubble trap [79], (D) paper MFC [80], and (E) shared cathode [81].”
BackgroundMethodShen, Q., Zhou, Q., Shang, J., Shao, S., Zhang, L., & Fan, C. (2014) · Journal of Environmental Sciences · doi:10.1016/s1001-0742(13)60452-0 · Cited by 81 · cited 1×
“Recent years, periodic oxygen stratification was found in some shallow-water freshwater high-nutrient lakes, which eventually leads to the formation of “dead zone” in the lakes [104,105].”
BackgroundXu, Z., Liu, B., Dong, Q., Lei, Y., Li, Y., Ren, J., McCutcheon, J. R., & Li, B. (2015) · Bioresource Technology · doi:10.1016/j.biortech.2015.08.081 · Cited by 78 · cited 2×
“[77] developed a flat membrane-based MFC sensor (Figure 3A) and tested it with two ions (Cr6+ and Ni2+).”
BackgroundMethodA cathode-shared microbial fuel cell sensor array for water alert system
Jiang, Y. G., Liang, P., Liu, P., Yan, X., Bian, Y., & Huang, X. (2016) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2016.12.050 · Cited by 67
Stein, N. E., Hamelers, H. V. M., & Buisman, C. N. J. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.05.076 · Cited by 67
Microbial fuel-cell-based toxicity sensor for fast monitoring of acidic toxicity
Shen, Y. J., Lefebvre, O., Tan, Z., & Ng, H. Y. (2012) · Water Science & Technology · doi:10.2166/wst.2012.957 · Cited by 66 · cited 1×
“[97] designed a single-chamber air cathode MFC and operated it in a continuous batch mode.”
MethodMelamed, S., Elad, T., & Belkin, S. (2011) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2011.11.024 · Cited by 65 · cited 1×
“According to the type of biorecognition, biosensors can be categorized as immunosensors [5], enzymatic biosensors [6], DNA biosensors [7], cell-based biosensors [8], and biomimetic biosensors [9].”
BackgroundJiang, Y. G., Liang, P., Huang, X., & Ren, Z. J. (2018) · Chemosphere · doi:10.1016/j.chemosphere.2018.03.169 · Cited by 61 · cited 1×
“constructed a gas diffusion–biocathode sensing element to detect formaldehyde, which could be applied for monitoring gaseous pollutants [114].”
BackgroundImpact of tobramycin on the performance of microbial fuel cell
Wu, W., Lesnik, K. L., Xu, S., Wang, L., & Liu, H. (2014) · Microbial Cell Factories · doi:10.1186/s12934-014-0091-6 · Cited by 58
Sun, H., Zhang, Y., Wu, S., Dong, R., & Angelidaki, İ. (2018) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2018.11.336 · Cited by 54 · cited 1×
“[111] also reported the current density of MFC was linear toward acetate concentration up to 20 mM, and only minor interference could be detected from the other volatile fatty acids existed in the anaerobic digestor.”
BackgroundDevelopment and Long-Term Stability of a Novel Microbial Fuel Cell BOD Sensor with MnO2 Catalyst
Kharkwal, S., Tan, Y., Lü, M., & Ng, H. Y. (2017) · International Journal of Molecular Sciences · doi:10.3390/ijms18020276 · Cited by 51 · cited 1×
“[70] utilized manganese dioxide (β-MnO2) rather than platinum as the catalyst for oxygen reduction in a single-chamber air-cathode MFC.”
MethodHarvey, J., Hardy, S. C., & Ashford, M. L. J. (1999) · British Journal of Pharmacology · doi:10.1038/sj.bjp.0702267 · Cited by 49 · cited 1×
“However, they also caused “side effects” to the cellular metabolism [60,61], which could subsequently interrupt the extracellular electron transfer.”
BackgroundYang, G., Sun, Y., Kong, X., Zhen, F., Li, Y., Li, D., Lei, T., Yuan, Z., & Chen, G. (2013) · Water Science & Technology · doi:10.2166/wst.2013.415 · Cited by 48 · cited 1×
“6 mg/L 30–130 min [21] GF CC/Pt – 5–120 mg/L 132 min [22] GF GF/Pt CEM 20–200 mg/L 5–36 min [23] CC CC/Pt SPEEK 0–650 mg/L 80 min [24] GR CP PF 32–1280 mg/L 300–1200 min [25]”
Electricity generation by anaerobic bacteria and anoxic sediments from hypersaline soda lakes
Miller, L. G., & Oremland, R. S. (2008) · Extremophiles · doi:10.1007/s00792-008-0191-5 · Cited by 42 · cited 1×
“to predict the presence of arsenate-respiring bacteria in soda lakes because of the competence of arsenate against anode for electrons [108].”
BackgroundZhang, M., Yu, Y., Yang, Z., Shi, X., & Kong, F. (2012) · Canadian Journal of Fisheries and Aquatic Sciences · doi:10.1139/f2012-113 · Cited by 32
Microbial Fuel Cells Applied to the Metabolically Based Detection of Extraterrestrial Life
Abrevaya, X. C., Mauas, P. J. D., & Cortón, E. (2010) · Astrobiology · doi:10.1089/ast.2009.0460 · Cited by 28 · cited 1×
“[109] to use MFC to detect living (micro)organisms in other planets assuming they could also export electrons during their life process.”
MethodTran, P. H., Luong, T. T. T., Nguyen, T. T. T., Nguyen, H. Q., Duong, H. V., Kim, B. H., & Pham, H. T. (2015) · Environmental Science Processes & Impacts · doi:10.1039/c5em00099h · Cited by 23 · cited 1×
“[88] inoculated this specific bacterial consortia in the anode to build an MFC-based sensor.”
BackgroundWu, S.-S., Hernández, M., Deng, Y., Han, C., Hong, X., Xu, J., Zhong, W., & Deng, H. (2019) · FEMS Microbiology Ecology · doi:10.1093/femsec/fiz018 · Cited by 17 · cited 1×
“[115] proved the positive correlation between the voltage signals of MFC-based sensors and methane emission flux in paddy fields of China, developing a new method to evaluate methane emissions.”
Method
Cited by
Huang, C.-W., Lin, C., Nguyen, M. K., Hussain, A., Bui, X.-T., & Ngo, H. H. (2023) · Bioengineered · doi:10.1080/21655979.2022.2095089 · Cited by 227
“Microbial fuel cell (MFC)-based biosensors with single- or dual-chamber design were developed based on the oxidation of organic compounds and the corresponding electrical currents [80,81].”
MethodWlodkowic, D., & Karpiński, T. M. (2021) · Sensors · doi:10.3390/s21217028 · Cited by 28
Metadata
- Authors
- Cui, Y., Lai, B., & Tang, X.
- Venue
- Biosensors
- Publisher
- MDPI AG
- Published
- 2019-07-23
- Volume
- 9
- Issue
- 3
- Pages
- 92
- ISSN
- 2079-6374 (ISSN-L)
- OpenAlex
- W2963042092
- Cited by
- 167
- References
- 72
- FWCI
- 7.05
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.