Skin-on-a-Chip: Transepithelial Electrical Resistance and Extracellular Acidification Measurements through an Automated Air-Liquid Interface
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Skin is a critical organ that plays a crucial role in defending the internal organs of the body. For this reason, extensive work has gone into creating artificial models of the epidermis for in vitro skin toxicity tests. These tissue models, called reconstructed human epidermis (RhE), are used by researchers in the pharmaceutical, cosmetic, and environmental arenas to evaluate skin toxicity upon exposure to xenobiotics. Here, we present a label-free solution that leverages the use of the intelligent mobile lab for in vitro diagnostics (IMOLA-IVD), a noninvasive, sensor-based platform, to monitor the transepithelial electrical resistance (TEER) of RhE models and adherent cells cultured on porous membrane inserts. Murine fibroblasts cultured on polycarbonate membranes were first used as a test model to optimize procedures using a custom BioChip encapsulation design, as well as dual fluidic configurations, for continuous and automated perfusion of membrane-bound cultures. Extracellular acidification rate (EAR) and TEER of membrane-bound L929 cells were monitored. The developed protocol was then used to monitor the TEER of MatTek EpiDermTM RhE models over a period of 48 h. TEER and EAR measurements demonstrated that the designed system is capable of maintaining stable cultures on the chip, monitoring metabolic parameters, and revealing tissue breakdown over time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sandby-Møller, J., Poulsen, T., & Wulf, H. C. (2003) · Acta Dermato-Venereologica · doi:10.1080/00015550310015419 · Cited by 737
Henry, O. Y. F., Villenave, R., Cronce, M. J., Leineweber, W. D., Benz, M. A., & Ingber, D. E. (2017) · Lab on a Chip · doi:10.1039/c7lc00155j · Cited by 482 · cited 2×
“Next to microfabrication approaches [19,21], there are several commercially available external test systems, like the ‘volt-ohmmeters’ (World Precision Instruments, Sarasota, FL, USA), which can be used off the shelf.”
BackgroundMethodWagner, I., Materne, E.-M., Brincker, S., Süßbier, U., Frädrich, C., Busek, M., Sonntag, F., Sakharov, D. A., Trushkin, E. V., Tonevitsky, A. G., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50234a · Cited by 476
Human Skin 3D Bioprinting Using Scaffold‐Free Approach
Pourchet, L. J., Thepot, A., Albouy, M., Courtial, E. J., Boher, A., Blum, L. J., & Marquette, C. A. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201601101 · Cited by 352
Maoz, B. M., Herland, A., Henry, O. Y. F., Leineweber, W. D., Yadid, M., Doyle, J., Mannix, R., Kujala, V. J., FitzGerald, E. A., Parker, K. K., et al. (2017) · Lab on a Chip · doi:10.1039/c7lc00412e · Cited by 266 · cited 1×
“Next to microfabrication approaches [19,21], there are several commercially available external test systems, like the ‘volt-ohmmeters’ (World Precision Instruments, Sarasota, FL, USA), which can be used off the shelf.”
Method
Cited by
Organ-on-a-chip: recent breakthroughs and future prospects
Wu, Q., Liu, J., Wang, X., Feng, L., Wu, J., Zhu, X., Wen, W., & Gong, X. (2020) · BioMedical Engineering OnLine · doi:10.1186/s12938-020-0752-0 · Cited by 701
Evolution of Biochip Technology: A Review from Lab-on-a-Chip to Organ-on-a-Chip
Azizipour, N., Avazpour, R., Rosenzweig, D. H., Sawan, M., & Ajji, A. (2020) · Micromachines · doi:10.3390/mi11060599 · Cited by 277
Recent Advances in Body-on-a-Chip Systems
Sung, J. H., Wang, Y. I., Narasimhan Sriram, N., Jackson, M., Long, C., Hickman, J. J., & Shuler, M. L. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05293 · Cited by 268
Targeting the Complexity of In Vitro Skin Models: A Review of Cutting-Edge Developments
Quílez, C., Bebiano, L. B., Jones, E., Maver, U., Meesters, L., Parzymies, P., Petiot, E., Rikken, G., Risueño, I., Zaidi, H., et al. (2024) · Journal of Investigative Dermatology · doi:10.1016/j.jid.2024.04.032 · Cited by 65
Soucy, J. R., Bindas, A. J., Koppes, A. N., & Koppes, R. A. (2019) · iScience · doi:10.1016/j.isci.2019.10.052 · Cited by 62
Metadata
- Authors
- Alexander, F. A., Eggert, S., & Wiest, J.
- Venue
- Genes
- Publisher
- MDPI AG
- Published
- 2018-02-21
- Volume
- 9
- Issue
- 2
- Pages
- 114
- ISSN
- 2073-4425 (ISSN-L)
- OpenAlex
- W2790704944
- Cited by
- 82
- References
- 5
- FWCI
- 3.21
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.