Air Change Rates and Interzonal Flows in Residences, and the Need for Multi-Zone Models for Exposure and Health Analyses
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Air change rates (ACRs) and interzonal flows are key determinants of indoor air quality (IAQ) and building energy use. This paper characterizes ACRs and interzonal flows in 126 houses, and evaluates effects of these parameters on IAQ. ACRs measured using weeklong tracer measurements in several seasons averaged 0.73 ± 0.76 h−1 (median = 0.57 h−1, n = 263) in the general living area, and much higher, 1.66 ± 1.50 h−1 (median = 1.23 h−1, n = 253) in bedrooms. Living area ACRs were highest in winter and lowest in spring; bedroom ACRs were highest in summer and lowest in spring. Bedrooms received an average of 55 ± 18% of air from elsewhere in the house; the living area received only 26 ± 20% from the bedroom. Interzonal flows did not depend on season, indoor smoking or the presence of air conditioners. A two-zone IAQ model calibrated for the field study showed large differences in pollutant levels between the living area and bedroom, and the key parameters affecting IAQ were emission rates, emission source locations, air filter use, ACRs, interzonal flows, outdoor concentrations, and PM penetration factors. The single-zone models that are commonly used for residences have substantial limitations and may inadequately represent pollutant concentrations and exposures in bedrooms and potentially other environments other where people spend a substantial fraction of time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Indoor particulate matter of outdoor origin: Importance of size-dependent removal mechanisms
Riley, W. J., McKone, T. E., Lai, A. C. K., & Nazaroff, W. W. (2002) · Environmental Science & Technology · doi:10.1021/es010723y · Cited by 417 · cited 1×
“6 h have been proposed based on theoretical and experimental values [23,25–27].”
BackgroundEffects of room furnishings and air speed on particle deposition rates indoors
Thatcher, T. L., Lai, A. C. K., Moreno-Jackson, R., Sextro, R. G., & Nazaroff, W. W. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00157-7 · Cited by 416 · cited 1×
“6 h have been proposed based on theoretical and experimental values [23,25–27].”
BackgroundWALLACE, L. A., EMMERICH, S. J., & HOWARD-REED, C. (2002) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500229 · Cited by 260 · cited 7×
“In summer and in warm climates, air conditioner use can lower ACRs, as seen in Houston, while in moderate climates or when temperatures are mild, natural (and sometimes mechanical) ventilation promoted by opened windows and doors increases ACRs [9,35,41].”
BackgroundInfluentialYamamoto, N., Shendell, D. G., Winer, A. M., & Zhang, J. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2009.00622.x · Cited by 156
Research works printed but not linked: 38
- Breen, 2010, Predicting residential air exchange rates from questionnaires and meteorology: Model evaluation in central north Carolina, Environ. Sci. Technol., 44, 9349, 10.1021/es101800k · DOI · Paper page
- Klepeis, 2006, Modeling residential exposure to secondhand tobacco smoke, Atmos. Environ., 40, 4393, 10.1016/j.atmosenv.2006.03.018 · DOI
- Burke, 2001, A population exposure model for particulate matter: Case study results for PM2.5 in Philadelphia, PA, J. Expos. Anal. Environ. Epidem., 11, 470, 10.1038/sj.jea.7500188 · DOI · Paper page
- Miller, 2001, Environmental tobacco smoke particles in multizone indoor environments, Atmos. Environ., 35, 2053, 10.1016/S1352-2310(00)00506-9 · DOI
- Jia, 2010, Sources and migration of volatile organic compounds in mixed-use buildings, Indoor Air, 20, 357, 10.1111/j.1600-0668.2010.00643.x · DOI
- Lai, 2000, Modeling indoor particle deposition from turbulent flow onto smooth surfaces, J. Aerosol Sci., 31, 463, 10.1016/S0021-8502(99)00536-4 · DOI · Paper page
- Wallace, 2004, Effect of central fans and in-duct filters on deposition rates of ultrafine and fine particles in an occupied townhouse, Atmos. Environ., 38, 405, 10.1016/j.atmosenv.2003.10.003 · DOI
- Wallace, 2002, The effect of opening windows on air change rates in two homes, J. Air Waste Manage. Assoc., 52, 147, 10.1080/10473289.2002.10470775 · DOI · Paper page
- Xu, 2010, Effectiveness of heating, ventilation and air conditioning system with HEPA filter unit on indoor air quality and asthmatic children’s health, Bldg. Environ., 45, 330, 10.1016/j.buildenv.2009.06.010 · DOI
- Johnson, 2004, A pilot study using scripted ventilation conditions to identify key factors affecting indoor pollutant concentration and air exchange rate in a residence, J. Expos. Anal. Environ. Epidem., 14, 1, 10.1038/sj.jea.7500294 · DOI
- Lohascio, 1996, Effectiveness of in-room air filtration and dilution ventilation for tuberculosis infection control, J. Air Waste Manage. Assoc., 46, 869, 10.1080/10473289.1996.10467523 · DOI
- Ott, 2003, Analytical solutions to compartmental indoor air quality models with application to environmental tobacco smoke concentrations measured in a house, J. Air Waste Manage. Assoc., 53, 918, 10.1080/10473289.2003.10466248 · DOI
- Du, 2011, Particle concentrations and effectiveness of free-standing air filters in bedrooms of children with asthma in Detroit, Michigan, Bldg. Environ., 46, 2303, 10.1016/j.buildenv.2011.05.012 · DOI
- Jia, 2007, Continuous, intermittent and passive sampling of airborne VOCs, J. Environ. Monitor., 9, 1220, 10.1039/b708119g · doi:10.1039/b708119g
- Batterman, 2002, Low-flow active and passive sampling of VOCs using thermal desorption tubes: Theory and application at an offset printing facility, J. Environ. Monit., 4, 361, 10.1039/b203289a · DOI
- Batterman, 2006, Simultaneous measurement of ventilation using tracer gas techniques and VOC concentrations in homes, garages and vehicles, J. Environ. Monit., 8, 249, 10.1039/b514899e · DOI
- Charles, 2008, VOC and particulate emissions from commercial cigarettes: Analysis of 2,5-DMF as an ETS tracer, Environ. Sci. Technol., 4, 1324, 10.1021/es072062w · DOI
- Batterman, 2012, Particulate matter concentrations in residences: An intervention study evaluating stand-alone filters and air conditioners, Indoor Air, 22, 235, 10.1111/j.1600-0668.2011.00761.x · DOI
- Fisk, 2002, Performance and costs of particle air filtration technologies, Indoor Air, 12, 223, 10.1034/j.1600-0668.2002.01136.x · DOI · Paper page
- Zhao, 2009, Effect of particle spatial distribution on particle deposition in ventilation rooms, J. Hazard. Mater., 170, 449, 10.1016/j.jhazmat.2009.04.079 · DOI
- Vette, 2001, Characterization of indoor-outdoor aerosol concentration relationships during the Fresno PM exposure studies, Aerosol Sci. Technol., 34, 118, 10.1080/02786820117903 · DOI · Paper page
- Thatcher, 2003, A concentration rebound method for measuring particle penetration and deposition in the indoor environment, Aerosol Sci. Technol., 37, 847, 10.1080/02786820300940 · DOI
- Mosley, 2001, Penetration of ambient fine particles into the indoor environment, Aerosol Sci. Technol., 34, 127, 10.1080/02786820117449 · DOI · Paper page
- Jia, 2011, Variability of indoor and outdoor VOC measurements: An analysis using variance components, Environ. Pollut., 169, 152, 10.1016/j.envpol.2011.09.024 · DOI · Paper page
- Williams, 2009, The design and field implementation of the Detroit Exposure and Aerosol Research Study, J. Expo. Sci. Environ. Epidemiol., 19, 643, 10.1038/jes.2008.61 · DOI
- Batterman, 2007, Migration of volatile organic compounds from attached garages to residences: A major exposure source, Environ. Res., 104, 224, 10.1016/j.envres.2007.01.008 · DOI
- Stocco, 2008, Predicting personal exposure of Windsor, Ontario residents to volatile organic compounds using indoor measurements and survey data, Atmos. Environ., 42, 5905, 10.1016/j.atmosenv.2008.03.024 · DOI · Paper page
- Persily, 2010, Modeled infiltration rate distributions for U.S. housing, Indoor Air, 20, 473, 10.1111/j.1600-0668.2010.00669.x · DOI
- Beko, 2010, Ventilation rates in the bedrooms of 500 Danish children, Bldg. Environ., 45, 2289, 10.1016/j.buildenv.2010.04.014 · DOI · Paper page
- Beko, 2011, Modeling ventilation rates in bedrooms based on building characteristics and occupant behavior, Bldg. Environ., 46, 2230, 10.1016/j.buildenv.2011.05.002 · DOI
- Bornehag, 2005, Association between ventilation rates in 390 Swedish homes and allergic symptoms in children, Indoor Air, 15, 275, 10.1111/j.1600-0668.2005.00372.x · DOI · Paper page
- Chou, 2008, Natural ventilation efficiency in a bedroom with a central-pivoting window, Indoor Built Environ., 17, 164, 10.1177/1420326X08089621 · doi:10.1177/1420326x08089621
- Abt, 2000, Characterization of indoor particle sources: A study conducted in the metropolitan Boston area, Environ. Health Perspect., 108, 35, 10.1289/ehp.0010835 · DOI · Paper page
- Murray, 1995, Residential air exchange rates in the United States: Empirical and estimated parametric distributions by season and climatic region, Risk Anal., 15, 459, 10.1111/j.1539-6924.1995.tb00338.x · DOI · Paper page
- Cheng, 2011, Modeling exposure close to air pollution sources in naturally ventilated residences: Association of turbulent diffusion coefficient with air change rate, Environ. Sci. Technol., 45, 4016, 10.1021/es103080p · DOI
- Ferro, 2009, Effect of interior door position on room-to-room differences in residential pollutant concentrations after short-term releases, Atmos. Environ., 43, 706, 10.1016/j.atmosenv.2008.09.032 · doi:10.1016/j.atmosenv.2008.09.032
- He, 2004, Contribution from indoor sources to particle number and mass concentrations in residential houses, Atmos. Environ., 38, 3405, 10.1016/j.atmosenv.2004.03.027 · DOI · Paper page
- 1993, Environmental tobacco smoke: Multicomponent analysis and room-to-room distribution in homes, Tob. Control, 2, 222, 10.1136/tc.2.3.222 · doi:10.1136/tc.2.3.222
Cited by
Batterman, S. (2017) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph14020145 · Cited by 271
Self-citationLevels and sources of volatile organic compounds in homes of children with asthma
Chin, J.-Y., Godwin, C., Parker, E., Robins, T., Lewis, T., Harbin, P., & Batterman, S. (2014) · Indoor Air · doi:10.1111/ina.12086 · Cited by 165
“AERs for the house’s living area and child’s sleeping area, and interzonal flows between these areas have been reported elsewhere (Du et al., 2012).”
BackgroundInfluentialSelf-citationResidential air‐change rates: A critical review
Nazaroff, W. W. (2021) · Indoor Air · doi:10.1111/ina.12785 · Cited by 161
A review of air exchange rate models for air pollution exposure assessments
Breen, M. S., Schultz, B. D., Sohn, M. D., Long, T., Langstaff, J., Williams, R., Isaacs, K., Meng, Q. Y., Stallings, C., & Smith, L. (2014) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2013.30 · Cited by 69
Self-citationVOC sources and exposures in nail salons: a pilot study in Michigan, USA
Zhong, L., Batterman, S., & Milando, C. W. (2019) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-018-1353-0 · Cited by 62
Self-citationLin, N., Rosemberg, M., Li, W., Meza‐Wilson, E., Godwin, C., & Batterman, S. (2021) · Indoor Air · doi:10.1111/ina.12709 · Cited by 59
Self-citation
Metadata
- Authors
- Du, L., Batterman, S., Godwin, C., Chin, J.-Y., Parker, E., Breen, M., Brakefield, W., Robins, T., & Lewis, T.
- Venue
- International Journal of Environmental Research and Public Health
- Publisher
- MDPI AG
- Published
- 2012-12-12
- Volume
- 9
- Issue
- 12
- Pages
- 4639-4661
- ISSN
- 1660-4601 (ISSN-L)
- OpenAlex
- W2004488022
- Cited by
- 60
- References
- 4
- FWCI
- 2.28
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.