Hypertension Assessment Using Photoplethysmography: A Risk Stratification Approach
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Hypertension is a common chronic cardiovascular disease (CVD). Early screening and diagnosis of hypertension plays a major role in its prevention and in the control of CVDs. Our study discusses the early screening of hypertension while using the morphological features of photoplethysmography (PPG). Numerous morphological features of PPG and its derivative waves were defined and extracted. Six types of feature selection methods were chosen to screen and evaluate these PPG morphological features. The optimal features were comprehensively analyzed in relation to the physiological processes of the cardiovascular circulatory system. Particularly, the intrinsic relation and physiological significance between the formation process of systolic blood pressure (SBP) and PPG morphology features were analyzed in depth. A variety of linear and nonlinear classification models were established for the comparison trials. The F1 scores for the normotension versus prehypertension, normotension and prehypertension versus hypertension, and normotension versus hypertension trials were 72.97%, 81.82%, and 92.31%, respectively. In summary, this study established a PPG characteristic analysis model and established the intrinsic relationship between SBP and PPG characteristics. Finally, the risk stratification of hypertension at different stages was examined and compared based on the optimal feature subset.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Theoretical and Empirical Analysis of ReliefF and RReliefF
Robnik-Šikonja, M., & Kononenko, I. (2003) · Machine Learning · doi:10.1023/a:1025667309714 · Cited by 3,025 · cited 6×
“Kononenko [41] proposed the ReliefF method, which is based on Relief, to solve multi-class classification.”
MethodInfluentialOn the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206 · cited 3×
“As is well-known, the S wave and c wave exhibit different morphological changes under different physiological statuses, especially different BP levels [13,30].”
BackgroundMethodSelf-citationToward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935 · cited 2×
“Meanwhile, arterial wave propagation theory [16] and PPG morphological theory have also been researched: The former is based on ECGs or other physiological signals and the PPG signal, while the latter is based on PPG morphological features.”
BackgroundCuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring
Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2580904 · Cited by 621 · cited 2×
“Therefore, the early screening and evaluation of patients with hypertension or prehypertension is of great practical significance [5,6].”
BackgroundAlian, A. A., & Shelley, K. H. (2014) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2014.08.006 · Cited by 289
An optimal filter for short photoplethysmogram signals
Liang, Y., Elgendi, M., Chen, Z., & Ward, R. (2018) · Scientific Data · doi:10.1038/sdata.2018.76 · Cited by 242 · cited 2×
“5 Hz–10 Hz bandpass Chebyshev II filter was used to filter noise and improve the PPG signal quality while, at the same time, the PPG features were kept undistorted [27].”
Self-citationA new, short-recorded photoplethysmogram dataset for blood pressure monitoring in China
Liang, Y., Chen, Z., Liu, G., & Elgendi, M. (2018) · Scientific Data · doi:10.1038/sdata.2018.20 · Cited by 215 · cited 5×
“Data collection was performed on 219 subjects recruited from Guilin People’s Hospital [26] and was conducted according to the ethics rules and regulations of both the hospital and the Guilin University of Ele tronic Technology in China fter approval by the ethics committee.”
BackgroundMethodInfluentialAllen, J., & Murray, A. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/306 · Cited by 202
Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes
Allen, J., & Murray, A. (2002) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001478 · Cited by 179 · cited 1×
“The common PPG acquisition methods can be divided into transmission and reflection methods [18].”
MethodDrawz, P. E., Pajewski, N. M., Bates, J. T., Bello, N. A., Cushman, W. C., Dwyer, J. P., Fine, L. J., Goff, D. C., Haley, W. E., Krousel-Wood, M., et al. (2017) · Hypertension · doi:10.1161/hypertensionaha.116.08076 · Cited by 170
Cited by
The use of photoplethysmography for assessing hypertension
Elgendi, M., Fletcher, R., Liang, Y., Howard, N., Lovell, N. H., Abbott, D., Lim, K., & Ward, R. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0136-7 · Cited by 625
Self-citationWulff, V., Hepp, P., Wolf, O. T., Balan, P., Hagenbeck, C., Fehm, T., & Schaal, N. K. (2021) · Archives of gynecology and obstetrics · doi:10.1007/s00404-020-05727-8 · Cited by 101
Boonya-ananta, T., Rodriguez, A. J., Ajmal, A., Du Le, V. N., Hansen, A. K., Hutcheson, J. D., & Ramella-Roman, J. C. (2021) · Scientific Reports · doi:10.1038/s41598-021-82124-4 · Cited by 70
Metadata
- Authors
- Liang, Y., Chen, Z., Ward, R., & Elgendi, M.
- Venue
- Journal of Clinical Medicine
- Publisher
- MDPI AG
- Published
- 2018-12-21
- Volume
- 8
- Issue
- 1
- Pages
- 12
- ISSN
- 2077-0383 (ISSN-L)
- OpenAlex
- W2906577143
- Cited by
- 97
- References
- 10
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hypertension Assessment Using Photoplethysmography: A Risk Stratification Approach. https://app.cochat.ai/papers/10.3390/jcm8010012
- The paper
- Liang, Y., Chen, Z., Ward, R., & Elgendi, M. (2018). Hypertension Assessment Using Photoplethysmography: A Risk Stratification Approach. Journal of Clinical Medicine. https://doi.org/10.3390/jcm8010012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.