CoChat

Guide to Semi-Quantitative Non-Targeted Screening Using LC/ESI/HRMS

Open access
Malm, Louise, Palm, Emma, Souihi, Amina, Plassmann, Merle, Liigand, Jaanus, Kruve, Anneli · 2021 · Molecules
Cited by 131

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Non-targeted screening (NTS) with reversed phase liquid chromatography electrospray ionization high resolution mass spectrometry (LC/ESI/HRMS) is increasingly employed as an alternative to targeted analysis; however, it is not possible to quantify all compounds found in a sample with analytical standards. As an alternative, semi-quantification strategies are, or at least should be, used to estimate the concentrations of the unknown compounds before final decision making. All steps in the analytical chain, from sample preparation to ionization conditions and data processing can influence the signals obtained, and thus the estimated concentrations. Therefore, each step needs to be considered carefully. Generally, less is more when it comes to choosing sample preparation as well as chromatographic and ionization conditions in NTS. By combining the positive and negative ionization mode, the performance of NTS can be improved, since different compounds ionize better in one or the other mode. Furthermore, NTS gives opportunities for retrospective analysis. In this tutorial, strategies for semi-quantification are described, sources potentially decreasing the signals are identified and possibilities to improve NTS are discussed. Additionally, examples of retrospective analysis are presented. Finally, we present a checklist for carrying out semi-quantitative NTS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/molecules26123524

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Research works printed but not linked: 60

  1. Hollender, 2017, Nontarget Screening with High Resolution Mass Spectrometry in the Environment: Ready to Go?, Environ. Sci. Technol., 51, 11505, 10.1021/acs.est.7b02184 · DOI · Paper page
  2. Kruve, 2018, Semi-quantitative Non-target Analysis of Water with Liquid Chromatography/High-resolution Mass Spectrometry: How Far Are We?, Rapid Commun. Mass Spectrom., 33, 54, 10.1002/rcm.8208 · DOI
  3. Bletsou, 2015, Targeted and Non-Targeted Liquid Chromatography-Mass Spectrometric Workflows for Identification of Transformation Products of Emerging Pollutants in the Aquatic Environment, TrAC Trends Anal. Chem., 66, 32, 10.1016/j.trac.2014.11.009 · DOI · Paper page
  4. Pluskal, T., Castillo, S., Villar-Briones, A., and Orešič, M. (2010). MZmine 2: Modular Framework for Processing, Visualizing, and Analyzing Mass Spectrometry-Based Molecular Profile Data. BMC Bioinform., 11. · DOI · Paper page
  5. Escher, 2011, Recent Advances in Environmental Risk Assessment of Transformation Products, Environ. Sci. Technol., 45, 3835, 10.1021/es1030799 · DOI · Paper page
  6. Kiefer, K., Müller, A., Singer, H., and Hollender, J. (2019). New Relevant Pesticide Transformation Products in Groundwater Detected Using Target and Suspect Screening for Agricultural and Urban Micropollutants with LC-HRMS. Water Res., 165. · DOI · Paper page
  7. Liigand, J., Wang, T., Kellogg, J., Smedsgaard, J., Cech, N., and Kruve, A. (2020). Quantification for Non-Targeted LC/MS Screening without Standard Substances. Sci. Rep., 10. · DOI · Paper page
  8. Kruve, 2020, Strategies for Drawing Quantitative Conclusions from Nontargeted Liquid Chromatography–High-Resolution Mass Spectrometry Analysis, Anal. Chem., 92, 4691, 10.1021/acs.analchem.9b03481 · DOI · Paper page
  9. Cech, 2001, Practical Implications of Some Recent Studies in Electrospray Ionization Fundamentals, Mass Spectrom. Rev., 20, 362, 10.1002/mas.10008 · DOI · Paper page
  10. Liigand, 2014, Effect of Mobile Phase on Electrospray Ionization Efficiency, J. Am. Soc. Mass Spectrom., 25, 1853, 10.1007/s13361-014-0969-x · DOI
  11. Kostiainen, 2009, Effect of Eluent on the Ionization Process in Liquid Chromatography–Mass Spectrometry, J. Chromatogr. A, 1216, 685, 10.1016/j.chroma.2008.08.095 · DOI · Paper page
  12. Kiontke, A., Oliveira-Birkmeier, A., Opitz, A., and Birkemeyer, C. (2016). Electrospray Ionization Efficiency Is Dependent on Different Molecular Descriptors with Respect to Solvent PH and Instrumental Configuration. PLoS ONE, 11. · doi:10.1371/journal.pone.0167502
  13. Page, 2007, Ionization and Transmission Efficiency in an Electrospray Ionization—Mass Spectrometry Interface, J. Am. Soc. Mass Spectrom., 18, 1582, 10.1016/j.jasms.2007.05.018 · DOI · Paper page
  14. Pieke, 2017, A Framework to Estimate Concentrations of Potentially Unknown Substances by Semi-Quantification in Liquid Chromatography Electrospray Ionization Mass Spectrometry, Anal. Chim. Acta, 975, 30, 10.1016/j.aca.2017.03.054 · DOI
  15. Espinosa, 2015, Exploring Analyte Response in an ESI-MS System with Different Chemometric Tools, Chemom. Intell. Lab. Syst., 146, 120, 10.1016/j.chemolab.2015.05.004 · DOI
  16. Aalizadeh, 2019, Development and Application of Retention Time Prediction Models in the Suspect and Non-Target Screening of Emerging Contaminants, J. Hazard. Mater., 363, 277, 10.1016/j.jhazmat.2018.09.047 · DOI · Paper page
  17. Kruve, 2021, Benchmarking of the Quantification Approaches for the Non-Targeted Screening of Micropollutants and Their Transformation Products in Groundwater, Anal. Bioanal. Chem., 413, 1549, 10.1007/s00216-020-03109-2 · DOI
  18. Chalcraft, 2009, Virtual Quantification of Metabolites by Capillary Electrophoresis-Electrospray Ionization-Mass Spectrometry: Predicting Ionization Efficiency Without Chemical Standards, Anal. Chem., 81, 2506, 10.1021/ac802272u · DOI · Paper page
  19. Dahal, 2011, Small Molecule Quantification by Liquid Chromatography-Mass Spectrometry for Metabolites of Drugs and Drug Candidates, Drug Metab. Dispos., 39, 2355, 10.1124/dmd.111.040865 · doi:10.1124/dmd.111.040865
  20. Oss, 2010, Electrospray Ionization Efficiency Scale of Organic Compounds, Anal. Chem., 82, 2865, 10.1021/ac902856t · DOI · Paper page
  21. Huffman, 2012, Effect of Polar Protic and Polar Aprotic Solvents on Negative-Ion Electrospray Ionization and Chromatographic Separation of Small Acidic Molecules, Anal. Chem., 84, 9942, 10.1021/ac302397b · DOI
  22. Park, 2020, Applications of Machine Learning to In Silico Quantification of Chemicals without Analytical Standards, J. Chem. Inf. Modeling, 60, 2718, 10.1021/acs.jcim.9b01096 · DOI
  23. Mayhew, 2020, New Approach Combining Molecular Fingerprints and Machine Learning to Estimate Relative Ionization Efficiency in Electrospray Ionization, ACS Omega, 5, 9510, 10.1021/acsomega.0c00732 · DOI
  24. Liigand, P., Liigand, J., Kaupmees, K., and Kruve, A. (2021). 30 Years of Research on ESI/MS Response: Trends, Contradictions and Applications. Anal. Chim. Acta, 1152. · DOI
  25. Brunner, A.M., Bertelkamp, C., Dingemans, M.M.L., Kolkman, A., Wols, B., Harmsen, D., Siegers, W., Martijn, B.J., Oorthuizen, W.A., and ter Laak, T.L. (2020). Integration of Target Analyses, Non-Target Screening and Effect-Based Monitoring to Assess OMP Related Water Quality Changes in Drinking Water Treatment. Sci. Total Environ., 705. · DOI
  26. Schymanski, 2014, Strategies to Characterize Polar Organic Contamination in Wastewater: Exploring the Capability of High Resolution Mass Spectrometry, Environ. Sci. Technol., 48, 1811, 10.1021/es4044374 · DOI · Paper page
  27. Sørensen, L., McCormack, P., Altin, D., Robson, W.J., Booth, A.M., Faksness, L.-G., Rowland, S.J., and Størseth, T.R. (2019). Establishing a Link between Composition and Toxicity of Offshore Produced Waters Using Comprehensive Analysis Techniques—A Way Forward for Discharge Monitoring?. Sci. Total Environ., 694. · doi:10.1016/j.scitotenv.2019.133682
  28. Blum, 2017, Non-Target Screening and Prioritization of Potentially Persistent, Bioaccumulating and Toxic Domestic Wastewater Contaminants and Their Removal in on-Site and Large-Scale Sewage Treatment Plants, Sci. Total Environ., 575, 265, 10.1016/j.scitotenv.2016.09.135 · DOI
  29. Baz-Lomba, J.A., Salvatore, S., Gracia-Lor, E., Bade, R., Castiglioni, S., Castrignanò, E., Causanilles, A., Hernandez, F., Kasprzyk-Hordern, B., and Kinyua, J. (2016). Comparison of Pharmaceutical, Illicit Drug, Alcohol, Nicotine and Caffeine Levels in Wastewater with Sale, Seizure and Consumption Data for 8 European Cities. BMC Public Health, 16. · DOI · Paper page
  30. Rousis, 2016, Wastewater-Based Epidemiology To Monitor Synthetic Cathinones Use in Different European Countries, Environ. Sci. Technol., 50, 10089, 10.1021/acs.est.6b02644 · DOI · Paper page
  31. Schulze, 2017, Assessment of a Novel Device for Onsite Integrative Large-Volume Solid Phase Extraction of Water Samples to Enable a Comprehensive Chemical and Effect-Based Analysis, Sci. Total Environ., 581–582, 350, 10.1016/j.scitotenv.2016.12.140 · DOI
  32. Dzuman, 2015, Multi-Analyte High Performance Liquid Chromatography Coupled to High Resolution Tandem Mass Spectrometry Method for Control of Pesticide Residues, Mycotoxins, and Pyrrolizidine Alkaloids, Anal. Chim. Acta, 863, 29, 10.1016/j.aca.2015.01.021 · DOI
  33. Kafeenah, 2019, Effect of Mobile Phase PH on the Electrospray Ionization Efficiency and Qualitative Analysis of Pharmaceuticals in ESI + LC-MS/MS, J. Chromatogr. Sci., 57, 847, 10.1093/chromsci/bmz061 · doi:10.1093/chromsci/bmz061
  34. Zhou, 2000, Protonation in Electrospray Mass Spectrometry: Wrong-Way-Round or Right-Way-Round?, J. Am. Soc. Mass Spectrom., 11, 961, 10.1016/S1044-0305(00)00174-4 · DOI
  35. Mallet, 2004, A Study of Ion Suppression Effects in Electrospray Ionization from Mobile Phase Additives and Solid-Phase Extracts, Rapid Commun. Mass Spectrom., 18, 49, 10.1002/rcm.1276 · DOI · Paper page
  36. Snyder, L.R., Kirkland, J.J., and Glajch, J.L. (1997). Practical HPLC Method Development, Wiley. [2nd ed.]. · DOI · Paper page
  37. Ojakivi, 2018, Modifying the Acidity of Charged Droplets, ChemistrySelect, 3, 335, 10.1002/slct.201702269 · doi:10.1002/slct.201702269
  38. Rebane, 2019, Ionization Efficiency Ladders as Tools for Choosing Ionization Mode and Solvent in Liquid Chromatography/Mass Spectrometry, Rapid Commun. Mass Spectrom., 33, 1834, 10.1002/rcm.8545 · doi:10.1002/rcm.8545
  39. Colizza, 2016, Acetonitrile Ion Suppression in Atmospheric Pressure Ionization Mass Spectrometry, J. Am. Soc. Mass Spectrom., 27, 1796, 10.1007/s13361-016-1466-1 · DOI
  40. Buszewski, 2012, Artifacts in Liquid-Phase Separations–System, Solvent, and Impurity Peaks, Chem. Rev., 112, 2629, 10.1021/cr200182j · doi:10.1021/cr200182j
  41. Srbek, 2005, System Peaks and Their Positive and Negative Aspects in Chromatographic Techniques, J. Sep. Sci., 28, 1263, 10.1002/jssc.200500168 · doi:10.1002/jssc.200500168
  42. Oberacher, H., Sasse, M., Antignac, J.-P., Guitton, Y., Debrauwer, L., Jamin, E.L., Schulze, T., Krauss, M., Covaci, A., and Caballero-Casero, N. (2020). A European Proposal for Quality Control and Quality Assurance of Tandem Mass Spectral Libraries. Environ. Sci. Eur., 32. · DOI
  43. Domingo-Almenara, X., Guijas, C., Billings, E., Montenegro-Burke, J.R., Uritboonthai, W., Aisporna, A.E., Chen, E., Benton, H.P., and Siuzdak, G. (2019). The METLIN Small Molecule Dataset for Machine Learning-Based Retention Time Prediction. Nat. Commun., 10. · DOI · Paper page
  44. Seo, 2016, The Impact of Environment and Resonance Effects on the Site of Protonation of Aminobenzoic Acid Derivatives, Phys. Chem. Chem. Phys., 18, 25474, 10.1039/C6CP04941A · DOI
  45. Liigand, 2017, Think Negative: Finding the Best Electrospray Ionization/MS Mode for Your Analyte, Anal. Chem., 89, 5665, 10.1021/acs.analchem.7b00096 · DOI · Paper page
  46. Cole, R.B. (2011). Electrospray and MALDI Mass Spectrometry Fundamentals, Instrumentation, Practicalities, and Biological Applications, Wiley. · doi:10.1002/9780470588901
  47. Kruve, 2017, Predicting ESI/MS Signal Change for Anions in Different Solvents, Anal. Chem., 89, 5079, 10.1021/acs.analchem.7b00595 · doi:10.1021/acs.analchem.7b00595
  48. Wang, T., Liigand, J., Frandsen, H.L., Smedsgaard, J., and Kruve, A. (2020). Standard Substances Free Quantification Makes LC/ESI/MS Non-Targeted Screening of Pesticides in Cereals Comparable between Labs. Food Chem., 318. · doi:10.1016/j.foodchem.2020.126460
  49. Lagerwerf, 2000, Exploring the Boundaries of Bioanalytical Quantitative LC–MS–MS, TrAC Trends Anal. Chem., 19, 418, 10.1016/S0165-9936(00)00009-1 · DOI
  50. Kirwan, 2013, Characterising and Correcting Batch Variation in an Automated Direct Infusion Mass Spectrometry (DIMS) Metabolomics Workflow, Anal. Bioanal. Chem., 405, 5147, 10.1007/s00216-013-6856-7 · DOI · Paper page
  51. Brunius, C., Shi, L., and Landberg, R. (2016). Large-Scale Untargeted LC-MS Metabolomics Data Correction Using between-Batch Feature Alignment and Cluster-Based within-Batch Signal Intensity Drift Correction. Metabolomics, 12. · DOI · Paper page
  52. Jiang, 2020, Signal Drift in Liquid Chromatography Tandem Mass Spectrometry and Its Internal Standard Calibration Strategy for Quantitative Analysis, Anal. Chem., 92, 7690, 10.1021/acs.analchem.0c00633 · DOI
  53. Knolhoff, 2021, A Proposed Quality Control Standard Mixture and Its Uses for Evaluating Nontargeted and Suspect Screening LC/HR-MS Method Performance, Anal. Chem., 93, 1596, 10.1021/acs.analchem.0c04036 · DOI
  54. Schulze, B., Jeon, Y., Kaserzon, S., Heffernan, A.L., Dewapriya, P., O’Brien, J., Gomez Ramos, M.J., Ghorbani Gorji, S., Mueller, J.F., and Thomas, K.V. (2020). An Assessment of Quality Assurance/Quality Control Efforts in High Resolution Mass Spectrometry Non-Target Workflows for Analysis of Environmental Samples. TrAC Trends Anal. Chem., 133. · DOI
  55. Alygizakis, 2019, NORMAN Digital Sample Freezing Platform: A European Virtual Platform to Exchange Liquid Chromatography High Resolution-Mass Spectrometry Data and Screen Suspects in “Digitally Frozen” Environmental Samples, TrAC Trends Anal. Chem., 115, 129, 10.1016/j.trac.2019.04.008 · DOI
  56. Haug, K., Cochrane, K., Nainala, V.C., Williams, M., Chang, J., Jayaseelan, K.V., and O’Donovan, C. (2019). MetaboLights: A Resource Evolving in Response to the Needs of Its Scientific Community. Nucleic Acids Res. · DOI · Paper page
  57. Sud, 2016, Metabolomics Workbench: An International Repository for Metabolomics Data and Metadata, Metabolite Standards, Protocols, Tutorials and Training, and Analysis Tools, Nucleic Acids Res., 44, D463, 10.1093/nar/gkv1042 · DOI · Paper page
  58. Kellogg, 2017, Comparison of Metabolomics Approaches for Evaluating the Variability of Complex Botanical Preparations: Green Tea ( Camellia Sinensis ) as a Case Study, J. Nat. Prod., 80, 1457, 10.1021/acs.jnatprod.6b01156 · DOI
  59. Hernando, 2007, Fast Separation Liquid Chromatography–Tandem Mass Spectrometry for the Confirmation and Quantitative Analysis of Avermectin Residues in Food, J. Chromatogr. A, 1155, 62, 10.1016/j.chroma.2007.02.120 · doi:10.1016/j.chroma.2007.02.120
  60. Liigand, 2015, Transferability of the Electrospray Ionization Efficiency Scale between Different Instruments, J. Am. Soc. Mass Spectrom., 26, 1923, 10.1007/s13361-015-1219-6 · doi:10.1007/s13361-015-1219-6

Cited by

See all 131

Metadata

Authors
Malm, L., Palm, E., Souihi, A., Plassmann, M., Liigand, J., & Kruve, A.
Venue
Molecules
Publisher
MDPI AG
Published
2021-06-09
Volume
26
Issue
12
Pages
3524
ISSN
1420-3049 (ISSN-L)
OpenAlex
W3168956483
Cited by
131
References
5
FWCI
4.83
Type
journal article
Language
en
Open access
gold
Funders
Svenska Forskningsrådet Formas (2020-01511)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Guide to Semi-Quantitative Non-Targeted Screening Using LC/ESI/HRMS. https://app.cochat.ai/papers/10.3390/molecules26123524
The paper
Malm, L., Palm, E., Souihi, A., Plassmann, M., Liigand, J., & Kruve, A. (2021). Guide to Semi-Quantitative Non-Targeted Screening Using LC/ESI/HRMS. Molecules. https://doi.org/10.3390/molecules26123524

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.