CoChat

Morphology, Crystallinity, and Molecular Weight of Poly(ε-caprolactone)/Graphene Oxide Hybrids

Open access

The DOI matches its Crossref record; 57 of the 58 references it cites were found in a registry or an index.

Abstract

A study was carried out to determine the effects of graphene oxide (GO) filler on the properties of poly(ε-caprolactone) (PCL) films. A series of nanocomposites were prepared, incorporating different graphene oxide filler contents (0.1, 0.2, and 0.5 wt%) by the solution mixing method, and an in-depth study was made of the morphological changes, crystallization, infrared absorbance, molecular weight, thermal properties, and biocompatibility as a function of GO content to determine their suitability for use in biomedical applications. The infrared absorbance showed the existence of intermolecular hydrogen bonds between the PCL’s carbonyl groups and the GO’s hydrogen-donating groups, which is in line with the apparent reduction in molecular weight at higher GO contents, indicated by the results of the gel permeation chromatography (GPC), and the thermal property analysis. Polarized optical microscopy (POM) showed that GO acts as a nucleating point for PCL crystals, increasing crystallinity and crystallization temperature. The biological properties of the composites studied indicate that adding only 0.1 wt% of GO can improve cellular viability and that the composite shows promise for use in biomedical applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/polym11071099

Cites

57 of 57 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Sample photographs (above) and transversal SEM images according to GO content.
Figure 1 Sample photographs (above) and transversal SEM images according to GO content.CC BY · PubMed Central
Figure 2 TEM images of GO (a); PCL/GO-0.2 (b); PCL/GO-0.5 (c) and PCL/GO-0.2 at higher magnification (d); Scale bar for (a) represents 5 microns, for (b,c) 2 microns and for (d) 500 nm.
Figure 2 TEM images of GO (a); PCL/GO-0.2 (b); PCL/GO-0.5 (c) and PCL/GO-0.2 at higher magnification (d); Scale bar for (a) represents 5 microns, for (b,c) 2 microns and for (d) 500 nm.CC BY · PubMed Central
Figure 3 Spherulite growth according to GO content (wt%). Graph shows the time at which crystallization is completed vs. GO content (wt%) (white bar represents 100 microns).
Figure 3 Spherulite growth according to GO content (wt%). Graph shows the time at which crystallization is completed vs. GO content (wt%) (white bar represents 100 microns).CC BY · PubMed Central
Figure 4 Spherulite final structure according to GO content (wt%) (black bar represents 200 µm).
Figure 4 Spherulite final structure according to GO content (wt%) (black bar represents 200 µm).CC BY · PubMed Central
Figure 5 FT-IR spectra of GO, neat PCL and PCL/GO composites.
Figure 5 FT-IR spectra of GO, neat PCL and PCL/GO composites.CC BY · PubMed Central
Figure 6 Experimental and fitted-curve FT-IR spectra of the C=O stretching region of (a) PCL (b) PCL/GO-0.5.
Figure 6 Experimental and fitted-curve FT-IR spectra of the C=O stretching region of (a) PCL (b) PCL/GO-0.5.CC BY · PubMed Central
Figure 7 Molecular weight distribution according to GO content (wt%).
Figure 7 Molecular weight distribution according to GO content (wt%).CC BY · PubMed Central
Figure 8 AFM phase image of GO flakes deposited onto mica.
Figure 8 AFM phase image of GO flakes deposited onto mica.CC BY · PubMed Central
Figure 9 Schematic representation of neat PCL (left) and PCL/GO (right) in a good solvent.
Figure 9 Schematic representation of neat PCL (left) and PCL/GO (right) in a good solvent.CC BY · PubMed Central
Figure 10 DSC scans for PCL/GO hybrids on cooling and second heating scan (after removing thermal history).
Figure 10 DSC scans for PCL/GO hybrids on cooling and second heating scan (after removing thermal history).CC BY · PubMed Central
Figure 11 (a) Effect of GO on hybrid crystallinity. (b) Effect of GO on crystallization and melting temperatures.
Figure 11 (a) Effect of GO on hybrid crystallinity. (b) Effect of GO on crystallization and melting temperatures.CC BY · PubMed Central
Figure 12 X-ray diffraction of neat PCL and PCL/GO hybrids.
Figure 12 X-ray diffraction of neat PCL and PCL/GO hybrids.CC BY · PubMed Central
Figure 13 Crystal size of the 110 and 200 planes for different samples.
Figure 13 Crystal size of the 110 and 200 planes for different samples.CC BY · PubMed Central
Figure 14 TG plots of PCL and PCL/GO nanocomposites.
Figure 14 TG plots of PCL and PCL/GO nanocomposites.CC BY · PubMed Central
Figure 15 Derivative thermogravimetric (DTG) curves of PCL and its nanocomposites.
Figure 15 Derivative thermogravimetric (DTG) curves of PCL and its nanocomposites.CC BY · PubMed Central
Figure 16 Relative absorbance of the MTT analysis as a function of GO composition. Values are presented as mean ± SD from six replicates at 48 h. Kruskal–Wallis test shows significant differences between materials (k = 22.4473; p = 0.00016). Mann–Whitney U-test showed significant differences between PCL and PCL/GO-0.1 ((U = 1; p = 0.0083), PCL and C- (U = 1; p = 0.0083), PCL /GO-0.1 and PCL/GO-0.2 (U = 2; p = 0.01314), PCL/GO-0.1 and PCL/GO-0.5 (U = 0; p = 0.00512), PCL /GO-0.2 and PCL/GO-0.5 (U = 0; p = 0.00512), PCL /GO-0.2 and C- (U = 2; p = 0.01314), and PCL /GO-0.5 and C- (U = 0; p = 0.00512), whereas no significant differences were found between PCL and PCL/GO-0.2 ((U = 12; p = 0.37886), PCL and PCL/GO-0.5 (U = 6; p = 0.06576), PCL/GO-0.1 and C- (U = 14; p = 0.57548).
Figure 16 Relative absorbance of the MTT analysis as a function of GO composition. Values are presented as mean ± SD from six replicates at 48 h. Kruskal–Wallis test shows significant differences between materials (k = 22.4473; p = 0.00016). Mann–Whitney U-test showed significant differences between PCL and PCL/GO-0.1 ((U = 1; p = 0.0083), PCL and C- (U = 1; p = 0.0083), PCL /GO-0.1 and PCL/GO-0.2 (U = 2; p = 0.01314), PCL/GO-0.1 and PCL/GO-0.5 (U = 0; p = 0.00512), PCL /GO-0.2 and PCL/GO-0.5 (U = 0; p = 0.00512), PCL /GO-0.2 and C- (U = 2; p = 0.01314), and PCL /GO-0.5 and C- (U = 0; p = 0.00512), whereas no significant differences were found between PCL and PCL/GO-0.2 ((U = 12; p = 0.37886), PCL and PCL/GO-0.5 (U = 6; p = 0.06576), PCL/GO-0.1 and C- (U = 14; p = 0.57548).CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 3

  1. Brodie, 1860, Sur le poids atomique du graphite, Ann. Chim. Phys., 59, e472
  2. Donlan, R.M., Wu, P., Grainger, D.W., and Ratner, B.D. (2004). An introduction to materials in medicine, Elsevier Academic Press.
  3. Klug, H.P., and Alexander, L.E. (1974). X-Ray Diffraction Procedures: For Polycrystalline and Amorphous Materials, John Wiley & Sons, Inc.. [2nd ed.].

Cited by

See all 89

Metadata

Authors
Castilla-Cortázar, I., Vidaurre, A., Marí, B., & Campillo-Fernández, A. J.
Affiliations
  • Centro de Biomateriales e Ingeniería Tisular (ES)
  • Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (ES)
  • Departamento de Física Aplicada-IDF, Universitat Politècnica de València, 46022 Valencia, Spain
Corresponding author
Campillo-Fernández, Alberto J.
Venue
Polymers
Publisher
MDPI AG
Published
2019-06-28
Volume
11
Issue
7
Pages
1099
ISSN
2073-4360 (ISSN-L)
OpenAlex
W2955563675
Cited by
86
References
58
Citations by year
2026: 8 · 2025: 14 · 2024: 17 · 2023: 13 · 2022: 20 · 2021: 8 · 2020: 4 · 2019: 2
FWCI
2.41
Type
journal article
Language
en
Open access
Locations
  • Polymers (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • RiuNet (Universitat Politècnica de València) (submittedVersion, cc-by-nc-nd)
Funders
  • Generalitat Valenciana (GV/2016/067)
  • Ministerio de Economía y Competitividad (MAT2016-76039-C4-3-R)
  • Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (C8041228)
Topics
  • Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
  • Physical Sciences › Materials Science › Polymers and Plastics › Polymer Nanocomposites and Properties
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
Keywords
polycaprolactone, graphene oxide, polymer nanocomposites, crystallinity, molecular weight reduction, hydrogen bonding, nucleation, thermal properties, biocompatibility, cell viability, biomedical materials, polymer films

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.