In this paper, we discuss the basic design requirements for the development of physiologically meaningful in vitro systems comprising cells, scaffolds and bioreactors, through a bottom up approach. Very simple micro- and milli-fluidic geometries are first used to illustrate the concepts, followed by a real device case-study. At each step, the fluidic and mass transport parameters in biological tissue design are considered, starting from basic questions such as the minimum number of cells and cell density required to represent a physiological system and the conditions necessary to ensure an adequate nutrient supply to tissues. At the next level, we consider the use of three-dimensional scaffolds, which are employed both for regenerative medicine applications and for the study of cells in environments which better recapitulate the physiological milieu. Here, the driving need is the rate of oxygen supply which must be maintained at an appropriate level to ensure cell viability throughout the thickness of a scaffold. Scaffold and bioreactor design are both critical in defining the oxygen profile in a cell construct and are considered together. We also discuss the oxygen-shear stress trade-off by considering the levels of mechanical stress required for hepatocytes, which are the limiting cell type in a multi-organ model. Similar considerations are also made for glucose consumption in cell constructs. Finally, the allometric approach for generating multi-tissue systemic models using bioreactors is described.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/pr2030548

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 65

  1. Cimetta, 2013, Bioengineering heart tissue for in vitro testing, Curr. Opin. Biotechnol., 24, 926, 10.1016/j.copbio.2013.07.002 · DOI · Paper page
  2. Rouwkema, 2011, In vitro platforms for tissue engineering: Implications for basic research and clinical translation, J. Tissue Eng. Regen. Med., 5, e164, 10.1002/term.414 · DOI
  3. Astashkina, 2012, A critical evaluation of in vitro cell culture models for high-throughput drug screening and toxicity, Pharmacol. Ther., 134, 82, 10.1016/j.pharmthera.2012.01.001 · DOI · Paper page
  4. Nerem, 2006, Tissue engineering: The hope, the hype, and the future, Tissue Eng., 12, 1143, 10.1089/ten.2006.12.1143 · DOI
  5. Shoji, 2004, Nutraceutics and delivery systems, J. Drug Target., 12, 385, 10.1080/10611860400003817 · DOI · Paper page
  6. Di Nardo, P., Minieri, M., and Ahluwalia, A. (2011). Stem Cell Engineering, Springer.
  7. Patzer, 2004, Oxygen consumption in a hollow fiber bioartificial liver, Artif. Organs, 28, 83, 10.1111/j.1525-1594.2004.07150.x · DOI
  8. Schyschka, 2013, Hepatic 3D cultures but not 2D cultures preserve specific transporter activity for acetaminophen-induced hepatotoxicity, Arch. Toxicol., 87, 1581, 10.1007/s00204-013-1080-y · DOI
  9. Francioli, 2010, Effect of three-dimensional expansion and cell seeding density on the cartilage-forming capacity of human articular chondrocytes in type II collagen sponges, J. Biomed. Mater. Res. A, 95, 924, 10.1002/jbm.a.32917 · DOI
  10. Iwasa, 2003, Effects of cell density on proliferation and matrix synthesis of chondrocytes embedded in atelocollagen gel, Artif. Organs, 27, 249, 10.1046/j.1525-1594.2003.07073.x · DOI
  11. Loeve, 2010, About a Definition of Nano: How to Articulate Nano and Technology?, Int. J. Philos. Chem., 6, 3
  12. Lee, 2008, Three-dimensional cellular microarray for high-throughput toxicology assays, Proc. Natl. Acad. Sci. USA, 105, 59, 10.1073/pnas.0708756105 · DOI · Paper page
  13. Sung, 2010, In vitro microscale systems for systematic drug toxicity study, Bioprocess Biosyst. Eng., 33, 5, 10.1007/s00449-009-0369-y · DOI
  14. Sung, 2010, Integration of in silico and in vitro platforms for pharmacokinetic-pharmacodynamic modeling, Expert Opin. Drug Metab. Toxicol., 6, 1063, 10.1517/17425255.2010.496251 · DOI · Paper page
  15. Wei, 2006, Elucidating in vitro cell-cell interaction using a microfluidic coculture system, Biomed. Microdevices, 8, 65, 10.1007/s10544-006-6384-8 · DOI
  16. Baudoin, 2007, Trends in the development of microfluidic cell biochips for in vitro hepatotoxicity, Toxicol. In Vitro, 21, 535, 10.1016/j.tiv.2006.11.004 · DOI
  17. Tingley, 2006, High-throughput cell culture: A real-world evaluation, Innov. Pharm. Technol., 54, 54
  18. Tilles, 2001, Effects of oxygenation and flow on the viability and function of rat hepatocytes cocultured in a microchannel flat-plate bioreactor, Biotechnol. Bioeng., 73, 379, 10.1002/bit.1071 · DOI · Paper page
  19. Park, 2008, Radial flow hepatocyte bioreactor using stacked microfabricated grooved substrates, Biotechnol. Bioeng., 99, 455, 10.1002/bit.21572 · DOI · Paper page
  20. McBeath, 2004, Cell shape, cytoskeletal tension, and RhoA regulate stem cell lineage commitment, Dev. Cell, 6, 483, 10.1016/S1534-5807(04)00075-9 · DOI · Paper page
  21. Francis, 1997, Effective intercellular communication distances are determined by the relative time constants for cyto/chemokine secretion and diffusion, Proc. Natl. Acad. Sci. USA, 94, 12258, 10.1073/pnas.94.23.12258 · DOI · Paper page
  22. Lundholt, 2003, A simple technique for reducing edge effect in cell-based assays, J. Biomol. Screening, 8, 566, 10.1177/1087057103256465 · DOI · Paper page
  23. Toepke, 2006, PDMS absorption of small molecules and consequences in microfluidic applications, Lab Chip, 6, 1484, 10.1039/b612140c · DOI · Paper page
  24. Mehta, 2009, Quantitative Inference of Cellular Parameters From Microfluidic Cell Culture Systems, Biotechnol. Bioeng., 103, 966, 10.1002/bit.22334 · doi:10.1002/bit.22334
  25. Mazzei, 2010, A low shear stress modular bioreactor for connected cell culture under high flow rates, Biotechnol. Bioeng., 106, 127, 10.1002/bit.22671 · DOI · Paper page
  26. Martin, 2005, Bioreactors for tissue mass culture: Design, characterization, and recent advances, Biomaterials, 26, 7481, 10.1016/j.biomaterials.2005.05.057 · DOI · Paper page
  27. Freshney, I.R. (2010). Culture of Animal Cells: A Manual of Basic Technique and Specialized Applications, Wiley-Blackwell. [6th ed.]. · DOI · Paper page
  28. Coleman, 1996, Plasticity of the hepatocyte phenotype in vitro: Complex phenotypic transitions in proliferating hepatocyte cultures suggest bipotent differentiation capacity of mature hepatocytes, Hepatology, 24, 1542, 10.1002/hep.510240642 · DOI
  29. Guillouzo, 1998, Liver cell models in in vitro toxicology, Environ. Health Perspect., 106, 511
  30. Nahmias, 2007, Integration of technologies for hepatic tissue engineering, Adv. Biochem. Eng. Biotechnol., 103, 309
  31. Smith, 2007, Hypoxia leads to necrotic hepatocyte death, J. Biomed. Mater. Res. A, 80, 520, 10.1002/jbm.a.30930 · DOI
  32. Tanaka, 2006, Evaluation of effects of shear stress on hepatocytes by a microchip-based system, Meas. Sci. Technol., 17, 3167, 10.1088/0957-0233/17/12/S08 · DOI · Paper page
  33. Nakatsuka, 2006, Shear stress induces hepatocyte PAI-1 gene expression through cooperative Sp1/Ets-1 activation of transcription, Am. J. Physiol. Gastrointest. Liver Physiol., 291, G26, 10.1152/ajpgi.00467.2005 · DOI
  34. Rutkowski, 2007, A driving force for change: Interstitial flow as a morphoregulator, Trends Cell Biol., 17, 44, 10.1016/j.tcb.2006.11.007 · DOI · Paper page
  35. Swartz, 2007, Interstitial flow and its effects in soft tissues, Annu. Rev. Biomed. Eng., 9, 229, 10.1146/annurev.bioeng.9.060906.151850 · DOI · Paper page
  36. Nearingburg, 2011, Finite element analysis of oxygen transport in microfluidic cell culture devices with varying channel architectures, perfusion rates, and materials, Chem. Eng. Sci., 66, 6244, 10.1016/j.ces.2011.09.007 · DOI
  37. Kim, 2013, Mathematical analysis of oxygen transfer through polydimethylsiloxane membrane between double layers of cell culture channel and gas chamber in microfluidic oxygenator, Microfluid. Nanofluidics, 15, 285, 10.1007/s10404-013-1142-8 · DOI · Paper page
  38. Tan, 2013, A thin-walled polydimethylsiloxane bioreactor for high-density hepatocyte sandwich culture, Biotechnol. Bioeng., 110, 1663, 10.1002/bit.24822 · DOI
  39. Silbey, R.J., Alberty, R.A., and Bawendi, M.G. (2005). Physical Chemistry, John Wiley & Sons.
  40. Nyberg, 1994, Primary hepatocytes outperform Hep G2 cells as the source of biotransformation functions in a bioartificial liver, Ann. Surg., 220, 59
  41. Frisancho, 1975, Functional adaptation to high altitude hypoxia, Science, 187, 313, 10.1126/science.1089311 · DOI · Paper page
  42. Buchwald, 2011, A local glucose-and oxygen concentration-based insulin secretion model for pancreatic islets, Theor. Biol. Med. Model., 8, 20, 10.1186/1742-4682-8-20 · DOI · Paper page
  43. Oller, 1989, Growth of mammalian cells at high oxygen concentrations, J. Cell Sci., 94, 43, 10.1242/jcs.94.1.43 · doi:10.1242/jcs.94.1.43
  44. Haselgrove, 1993, Computer modeling of the oxygen supply and demand of cells of the avian growth cartilage, Am. J. Physiol., 265, C497, 10.1152/ajpcell.1993.265.2.C497 · DOI
  45. Mehmetoglu, 1996, Oxygen diffusivity in calcium alginate gel beads containing Gluconobacter suboxydans, Artif. Cells Blood Substit. Immobil. Biotechnol., 24, 91, 10.3109/10731199609118877 · DOI
  46. Hulst, 1989, Determination of the effective diffusion coefficient of oxygen in gel materials in relation to gel concentration, Biotechnol. Tech., 3, 199, 10.1007/BF01875620 · doi:10.1007/bf01875620
  47. Ehsan, 2013, Nonsteady state oxygen transport in engineered tissue: Implications for design, Tissue Eng. A, 19, 1433, 10.1089/ten.tea.2012.0587 · DOI
  48. Everaerts, 1993, Diffusion coefficients of oxygen, hydrogen peroxide and glucose in a hydrogel, Anal. Chim. Acta, 273, 553, 10.1016/0003-2670(93)80202-V · doi:10.1016/0003-2670(93)80202-v
  49. Foy, 1994, A device to measure the oxygen uptake rate of attached cells: Importance in bioartificial organ design, Cell Transplant., 3, 515, 10.1177/096368979400300609 · DOI · Paper page
  50. De Groot, H., Littauer, A., and Noll, T. (1988). Oxygen Sensors Tissues, Springer.
  51. Vinci, 2010, Flow-regulated glucose and lipid metabolism in adipose tissue, endothelial cell and hepatocyte cultures in a modular bioreactor, Biotechnol. J., 5, 618, 10.1002/biot.201000009 · DOI
  52. Vinci, 2011, Modular bioreactor for primary human hepatocyte culture: Medium flow stimulates expression and activity of detoxification genes, Biotechnol. J., 6, 554, 10.1002/biot.201000326 · DOI · Paper page
  53. Vinci, 2012, An in vitro model of glucose and lipid metabolism in a multicompartmental bioreactor, Biotechnol. J., 7, 117, 10.1002/biot.201100177 · DOI
  54. Vinci, 2010, In vitro liver model using microfabricated scaffolds in a modular bioreactor, Biotechnol. J., 5, 232, 10.1002/biot.200900074 · DOI · Paper page
  55. Guzzardi, 2011, Metabolic control through hepatocyte and adipose tissue cross-talk in a multicompartmental modular bioreactor, Tissue Eng. A, 17, 1635, 10.1089/ten.tea.2010.0541 · DOI · Paper page
  56. Giulitti, 2013, Optimal periodic perfusion strategy for robust long-term microfluidic cell culture, Lab Chip, 13, 4430, 10.1039/c3lc50643f · DOI · Paper page
  57. Nishikawa, 2008, Enhanced maintenance and functions of rat hepatocytes induced by combination of on-site oxygenation and coculture with fibroblasts, J. Biotechnol., 133, 253, 10.1016/j.jbiotec.2007.08.041 · DOI
  58. Skolimowski, 2010, Microfluidic dissolved oxygen gradient generator biochip as a useful tool in bacterial biofilm studies, Lab Chip, 10, 2162, 10.1039/c003558k · DOI · Paper page
  59. Cimetta, 2007, Enhancement of viability of muscle precursor cells on 3D scaffold in a perfusion bioreactor, Int. J. Artif. Organs, 30, 415, 10.1177/039139880703000509 · DOI
  60. Iskander, 2009, Laminar Flow and Heat Transfer of Herschel-Bulkley Fluids in a Rectangular Duct; Finite-Element Analysis, Tikrit J. Sci. Eng., 12, 99
  61. Weibel, 2004, Allometric scaling of maximal metabolic rate in mammals: Muscle aerobic capacity as determinant factor, Respir. Physiol. Neurobiol., 140, 115, 10.1016/j.resp.2004.01.006 · DOI · Paper page
  62. 2006, Determination of the hepatocellularity number for human, dog, rabbit, rat and mouse livers from protein concentration measurements, Toxicol. In Vitro, 20, 1582, 10.1016/j.tiv.2006.06.003 · DOI · Paper page
  63. Sbrana, 2012, Engineering Quasi-Vivo in vitro organ models, Adv. Exp. Med. Biol., 745, 138, 10.1007/978-1-4614-3055-1_9 · DOI
  64. Vozzi, 2011, A flexible bioreactor system for constructing in vitro tissue and organ models, Biotechnol. Bioeng., 108, 2129, 10.1002/bit.23164 · DOI
  65. Haycock, J., Ahluwalia, A., and Wilkinson, M.J. (2014). Cellular In Vitro Testing: Methods and Protocols, Pan Stanford Publishing Pte. Ltd. · doi:10.1201/b15630

Cited by

See all 80

Metadata

Authors
Mattei, G., Giusti, S., & Ahluwalia, A.
Venue
Processes
Publisher
MDPI AG
Published
2014-07-25
Volume
2
Issue
3
Pages
548-569
ISSN
2227-9717 (ISSN-L)
OpenAlex
W2094220307
Cited by
80
References
7
FWCI
2.48
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.