Drift-Free Position Estimation of Periodic or Quasi-Periodic Motion Using Inertial Sensors
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Position sensing with inertial sensors such as accelerometers and gyroscopes usually requires other aided sensors or prior knowledge of motion characteristics to remove position drift resulting from integration of acceleration or velocity so as to obtain accurate position estimation. A method based on analytical integration has previously been developed to obtain accurate position estimate of periodic or quasi-periodic motion from inertial sensors using prior knowledge of the motion but without using aided sensors. In this paper, a new method is proposed which employs linear filtering stage coupled with adaptive filtering stage to remove drift and attenuation. The prior knowledge of the motion the proposed method requires is only approximate band of frequencies of the motion. Existing adaptive filtering methods based on Fourier series such as weighted-frequency Fourier linear combiner (WFLC), and band-limited multiple Fourier linear combiner (BMFLC) are modified to combine with the proposed method. To validate and compare the performance of the proposed method with the method based on analytical integration, simulation study is performed using periodic signals as well as real physiological tremor data, and real-time experiments are conducted using an ADXL-203 accelerometer. Results demonstrate that the performance of the proposed method outperforms the existing analytical integration method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adaptive cancelling of physiological tremor for improved precision in microsurgery
Riviere, C. N., Rader, R. S., & Thakor, N. V. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686791 · Cited by 260 · cited 5×
“In physiological tremor sensing for real-time compensation [9,10], zero-phase adaptive filtering algorithms based on truncated Fourier series such as weighted-frequency Fourier linear combiner (WFLC) [11-13] or band-limited multiple Fourier linear combiner (BMFLC) [14-16], which can detect periodic or quasi-periodic s…”
BackgroundMethodInfluentialToward active tremor canceling in handheld microsurgical instruments
Riviere, C. N., Ang, W. T., & Khosla, P. K. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817506 · Cited by 245
Self-citationNumerical double integration of acceleration measurements in noise
Thong, Y. K., Woolfson, M. S., Crowe, J. A., Hayes-Gill, B. R., & Jones, D. A. (2004) · Measurement · doi:10.1016/j.measurement.2004.04.005 · Cited by 206
Estimation of physiological tremor from accelerometers for real-time applications
Veluvolu, K. C., & Ang, W. T. (2011) · Sensors · doi:10.3390/s110303020 · Cited by 117 · cited 3×
“In physiological tremor sensing for real-time compensation [9,10], zero-phase adaptive filtering algorithms based on truncated Fourier series such as weighted-frequency Fourier linear combiner (WFLC) [11-13] or band-limited multiple Fourier linear combiner (BMFLC) [14-16], which can detect periodic or quasi-periodic s…”
BackgroundMethodSelf-citationModeling and canceling tremor in human-machine interfaces
Riviere, C. N., & Thakor, N. V. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.499755 · Cited by 114 · cited 5×
“In physiological tremor sensing for real-time compensation [9,10], zero-phase adaptive filtering algorithms based on truncated Fourier series such as weighted-frequency Fourier linear combiner (WFLC) [11-13] or band-limited multiple Fourier linear combiner (BMFLC) [14-16], which can detect periodic or quasi-periodic s…”
BackgroundMethodInfluentialAn adaptive estimation of periodic signals using a Fourier linear combiner
Vaz, C., Kong, X., & Thakor, N. (1994) · IEEE Transactions on Signal Processing · doi:10.1109/78.258116 · Cited by 108 · cited 1×
“Weighted-Frequency Fourier Linear Combiner (WFLC) The WFLC [11-13] algorithm extends the well-known Fourier Linear Combiner (FLC) [22] algorithm to also adapt to the time-varying reference signal frequency, using a modification of the least-mean-square (LMS) algorithm.”
MethodVeluvolu, K. C., & Ang, W. T. (2010) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.340 · Cited by 83
Self-citationEstimating displacement of periodic motion with inertial sensors
Tan, U.-X., Veluvolu, K. C., Latt, W. T., Shee, C. Y., Riviere, C. N., & Ang, W. T. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2008.917488 · Cited by 67
Self-citationAng, W. T., Khosla, P. K., & Riviere, C. N. (2004) · 2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422) · doi:10.1109/robot.2003.1241852 · Cited by 66
Self-citationVeluvolu, K. C., Latt, W. T., & Ang, W. T. (2010) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2009.06.001 · Cited by 65
Self-citation
Research works printed but not linked: 13
- Titterton, DH, and Weston, LJ (2004). Strapdown Inertial Navigation Technology, Institution of Engineering and Technology. · DOI · Paper page
- Yun, 2006, Design, implementation, and experimental results of a quaternion-based kalman filter for human body motion tracking, IEEE Trans. Rob, 22, 1216, 10.1109/TRO.2006.886270 · DOI · Paper page
- Foxlin, E, Harrington, M, and Pfeifer, G (1998, January 19–24). Constellation: A Wide-range Wireless Motion-tracking System for Augmented Reality and Virtual Set Applications. Orlando, FL, USA. · doi:10.1145/280814.280937
- Liu, 2009, Development of a wearable sensor system for quantitative gait analysis, Measurement, 42, 978, 10.1016/j.measurement.2009.02.002 · DOI · Paper page
- Schepers, 2010, Ambulatory estimation of foot placement during walking using inertial sensors, J. Biomech, 43, 3138, 10.1016/j.jbiomech.2010.07.039 · DOI
- Aminian, 2002, Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes, J. Biomech, 35, 689, 10.1016/S0021-9290(02)00008-8 · DOI · Paper page
- Ang, WT Active Tremor Compensation in Handheld Instrument for Microsurgery, Ph.D Thesis, The Robotics Institute, CMU: Pittsburgh, PA, USA, May 2004.
- Riviere, CN (1995). Adaptive Suppression of Tremor for Improved Human Machine Control, PhD Thesis, Johns Hopkins University, Baltimore, MD, USA.
- Latt, WT, Tan, UX, Shee, CY, and Ang, WT (2009, January 14–17). Real-time Estimation and Prediction of Periodic Signals from Attenuated and Phase-shifted Sensed Signals. Singapore. · DOI
- Elble, RJ, and Koller, WC (1990). Tremor, The Johns Hopkins University Press.
- Su, LM, Latt, WT, Ang, WT, Lim, TC, Teo, CL, and Burdet, E (2009, January 2–6). Micromanipulation Accuracy in Pointing and Tracing Investigated with a Contact-free Measurement System. Hilton Minneapolis, MN, USA. · DOI
- Thong, 2002, Dependence of inertial measurements of distance on accelerometer noise, Meas. Sci. Technol, 13, 1163, 10.1088/0957-0233/13/8/301 · DOI
- Latt, WT, Tan, UX, Shee, CY, and Ang, WT (2009, January 14–17). A Compact Hand-held Active Physiological Tremor Compensation Instrument. Singapore. · DOI
Cited by
Tatinati, S., Veluvolu, K. C., & Ang, W. T. (2015) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2014.2381495 · Cited by 77
Self-citationMultistep Prediction of Physiological Tremor for Surgical Robotics Applications
Veluvolu, K. C., Tatinati, S., Hong, S.-M., & Ang, W. T. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2264546 · Cited by 51
Self-citationAdaptive sliding bandlimited multiple fourier linear combiner for estimation of pathological tremor
Wang, S., Gao, Y., Zhao, J., & Cai, H. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.10.004 · Cited by 42
Bonnet, V., Mazzà, C., McCamley, J., & Cappozzo, A. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-29 · Cited by 32
Metadata
- Authors
- Latt, W. T., Veluvolu, K. C., & Ang, W. T.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2011-05-31
- Volume
- 11
- Issue
- 6
- Pages
- 5931-5951
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2081784408
- Cited by
- 53
- References
- 13
- FWCI
- 14.32
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Drift-Free Position Estimation of Periodic or Quasi-Periodic Motion Using Inertial Sensors. https://app.cochat.ai/papers/10.3390/s110605931
- The paper
- Latt, W. T., Veluvolu, K. C., & Ang, W. T. (2011). Drift-Free Position Estimation of Periodic or Quasi-Periodic Motion Using Inertial Sensors. Sensors. https://doi.org/10.3390/s110605931
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.