The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Optimal Placement of Accelerometers for the Detection of Everyday Activities
Open accessAbstract
This article describes an investigation to determine the optimal placement of accelerometers for the purpose of detecting a range of everyday activities. The paper investigates the effect of combining data from accelerometers placed at various bodily locations on the accuracy of activity detection. Eight healthy males participated within the study. Data were collected from six wireless tri-axial accelerometers placed at the chest, wrist, lower back, hip, thigh and foot. Activities included walking, running on a motorized treadmill, sitting, lying, standing and walking up and down stairs. The Support Vector Machine provided the most accurate detection of activities of all the machine learning algorithms investigated. Although data from all locations provided similar levels of accuracy, the hip was the best single location to record data for activity detection using a Support Vector Machine, providing small but significantly better accuracy than the other investigated locations. Increasing the number of sensing locations from one to two or more statistically increased the accuracy of classification. There was no significant difference in accuracy when using two or more sensors. It was noted, however, that the difference in activity detection using single or multiple accelerometers may be more pronounced when trying to detect finer grain activities. Future work shall therefore investigate the effects of accelerometer placement on a larger range of these activities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The WEKA data mining software: an update
Hall, M., Frank, E., Holmes, G., Pfahringer, B., Reutemann, P., & Witten, I. H. (2009) · ACM SIGKDD Explorations Newsletter · doi:10.1145/1656274.1656278 · Cited by 17,750
Top 10 algorithms in data mining
Wu, X., Kumar, V., Ross Quinlan, J., Ghosh, J., Yang, Q., Motoda, H., McLachlan, G. J., Ng, A., Liu, B., Yu, P. S., et al. (2008) · Knowledge and Information Systems · doi:10.1007/s10115-007-0114-2 · Cited by 5,667
Activity Recognition from User-Annotated Acceleration Data
Bao, L., & Intille, S. S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24646-6_1 · Cited by 3,147
Activity recognition from accelerometer data
Ravi, N., Dandekar, N., Mysore, P., & Littman, M. L. (2005) · Innovative Applications of Artificial Intelligence · Cited by 1,774
Karantonis, D. M., Narayanan, M. R., Mathie, M., Lovell, N. H., & Celler, B. G. (2006) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.856864 · Cited by 1,236
Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911
Mathie, M. J., Coster, A. C. F., Lovell, N. H., & Celler, B. G. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/2/r01 · Cited by 829
Activity Classification Using Realistic Data From Wearable Sensors
Parkka, J., Ermes, M., Korpipaa, P., Mantyjarvi, J., Peltola, J., & Korhonen, I. (2006) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.856863 · Cited by 760
Best Practices for Using Physical Activity Monitors in Population-Based Research
MATTHEWS, C. E., HAGSTRÖMER, M., POBER, D. M., & BOWLES, H. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399e5b · Cited by 703
Activity identification using body-mounted sensors—a review of classification techniques
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., Howard, D., Meijer, K., & Crompton, R. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/4/r01 · Cited by 600
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., & Howard, D. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2006190 · Cited by 551
Keller, T., Weisberger, A., Ray, J., Hasan, S., Shiavi, R., & Spengler, D. (1996) · Clinical Biomechanics · doi:10.1016/0268-0033(95)00068-2 · Cited by 530
Classification of basic daily movements using a triaxial accelerometer
Mathie, M. J., Celler, B. G., Lovell, N. H., & Coster, A. C. F. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02347551 · Cited by 453
Sensor Positioning for Activity Recognition Using Wearable Accelerometers
Atallah, L., Lo, B., King, R., & Yang, G.-Z. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2160540 · Cited by 346
Yang, J.-Y., Wang, J.-S., & Chen, Y.-P. (2008) · Pattern Recognition Letters · doi:10.1016/j.patrec.2008.08.002 · Cited by 335
The utility of the Digi-Walker step counter to assess daily physical activity patterns
WELK, G. J., DIFFERDING, J. A., THOMPSON, R. W., BLAIR, S. N., DZIURA, J., & HART, P. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00007 · Cited by 293
Detection of Type, Duration, and Intensity of Physical Activity Using an Accelerometer
BONOMI, A. G., GORIS, A. H. C., YIN, B., & WESTERTERP, K. R. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181a24536 · Cited by 245
Feature Selection and Activity Recognition from Wearable Sensors
Pirttikangas, S., Fujinami, K., & Nakajima, T. (2006) · Lecture Notes in Computer Science · doi:10.1007/11890348_39 · Cited by 229
A description of an accelerometer-based mobility monitoring technique
Lyons, G. M., Culhane, K. M., Hilton, D., Grace, P. A., & Lyons, D. (2005) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.11.006 · Cited by 218
Accelerometer Placement for Posture Recognition and Fall Detection
Gjoreski, H., Lustrek, M., & Gams, M. (2011) · 2011 Seventh International Conference on Intelligent Environments · doi:10.1109/ie.2011.11 · Cited by 207
Bonomi, A. G., Plasqui, G., Goris, A. H. C., & Westerterp, K. R. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00150.2009 · Cited by 196
Procedure for effortless in-field calibration of three-axial rate gyro and accelerometers
Ferraris, F., Grimaldi, U., & Parvis, M. (1995) · PORTO@Iris · Cited by 163
Human Activity Recognition: Accuracy across Common Locations for Wearable Sensors
õn, D. O. ́., & õn, O. ́. (2006) · Cited by 113
Towards Less Supervision in Activity Recognition from Wearable Sensors
Huỳnh, T., & Schiele, B. (2006) · Proceedings · doi:10.1109/iswc.2006.286336 · Cited by 102
The prediction of speed and incline in outdoor running in humans using accelerometry
HERREN, R., Sparti, A., Aminian, K., & Schütz, Y. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199907000-00020 · Cited by 99
Ambulatory monitoring of human posture and walking speed using wearable accelerometer sensors
Yeoh, W.-S., Pek, I., Yong, Y.-H., et al. (2008) · doi:10.1109/iembs.2008.4650382 · Cited by 68
A useful method for measuring daily physical activity by a three-direction monitor
Sugimoto, A., Hara, Y., Tw, F., & Yoncmoto, K. (1997) · Journal of Rehabilitation Medicine · doi:10.2340/1650197719973742 · Cited by 43
Activity/Posture Recognition using Wearable Sensors Placed on Different Body Locations
Gjoreski, H., & Gams, M. (2011) · doi:10.2316/p.2011.716-067 · Cited by 40
Biomedical Sensors for Ambient Assisted Living
McAdams, E. T., Géhin, C., Noury, N., Ramon, C., Nocua, R., Massot, B., de Oliveira, A. A. C., Dittmar, A., Nugent, C., & McLaughlin, J. (2009) · Lecture notes in electrical engineering · doi:10.1007/978-3-642-05167-8_14 · Cited by 19
Self-citationBergmann, J., Graham, S., Howard, N., & McGregor, A. H. (2013) · Measurement · doi:10.1016/j.measurement.2013.03.004 · Cited by 6
Cited by
Physical Human Activity Recognition Using Wearable Sensors
Attal, F., Mohammed, S., Dedabrishvili, M., Chamroukhi, F., Oukhellou, L., & Amirat, Y. (2015) · Sensors · doi:10.3390/s151229858 · Cited by 796
SisFall: A Fall and Movement Dataset
Sucerquia, A., López, J., & Vargas-Bonilla, J. (2017) · Sensors · doi:10.3390/s17010198 · Cited by 530
A survey on wearable sensor modality centred human activity recognition in health care
Wang, Y., Cang, S., & Yu, H. (2019) · Expert Systems with Applications · doi:10.1016/j.eswa.2019.04.057 · Cited by 409
Chung, S., Lim, J., Noh, K. J., Kim, G., & Jeong, H. (2019) · Sensors · doi:10.3390/s19071716 · Cited by 215
Efficient Human Activity Recognition Solving the Confusing Activities Via Deep Ensemble Learning
Zhu, R., Xiao, Z., Li, Y., Yang, M., Tan, Y., Zhou, L., Lin, S., & Wen, H. (2019) · IEEE Access · doi:10.1109/access.2019.2922104 · Cited by 86
Metadata
- Authors
- Cleland, I., Kikhia, B., Nugent, C., Boytsov, A., Hallberg, J., Synnes, K., McClean, S., & Finlay, D.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2013-07-17
- Volume
- 13
- Issue
- 7
- Pages
- 9183-9200
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2051029594
- Cited by
- 401
- References
- 30
- FWCI
- 31.60
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.