The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Fiber-Optic Chemical Sensors and Fiber-Optic Bio-Sensors
Open accessAbstract
This review summarizes principles and current stage of development of fiber-optic chemical sensors (FOCS) and biosensors (FOBS). Fiber optic sensor (FOS) systems use the ability of optical fibers (OF) to guide the light in the spectral range from ultraviolet (UV) (180 nm) up to middle infrared (IR) (10 μm) and modulation of guided light by the parameters of the surrounding environment of the OF core. The introduction of OF in the sensor systems has brought advantages such as measurement in flammable and explosive environments, immunity to electrical noises, miniaturization, geometrical flexibility, measurement of small sample volumes, remote sensing in inaccessible sites or harsh environments and multi-sensing. The review comprises briefly the theory of OF elaborated for sensors, techniques of fabrications and analytical results reached with fiber-optic chemical and biological sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-Dimensional Fluorescence Spectroscopy: A New Tool for On-Line Bioprocess Monitoring
Marose, S., Lindemann, C., & Scheper, T. (1998) · Biotechnology Progress · doi:10.1021/bp970124o · Cited by 190
Banerjee, P., Lenz, D., Robinson, J. P., Rickus, J. L., & Bhunia, A. K. (2008) · Laboratory Investigation · doi:10.1038/labinvest.3700703 · Cited by 97
Devos, Y., Aguilera, J., Diveki, Z., Gomes, A., Liu, Y., Paoletti, C., du Jardin, P., Herman, L., Perry, J. N., & Waigmann, E. (2014) · Transgenic Research · doi:10.1007/s11248-013-9741-4 · Cited by 95
Whole-cell biochips for bio-sensing: integration of live cells and inanimate surfaces
Ben-Yoav, H., Melamed, S., Freeman, A., Shacham-Diamand, Y., & Belkin, S. (2011) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2010.532767 · Cited by 52
Podrazký, O., Kuncová, G., Krasowska, A., & Sigler, K. (2003) · Folia Microbiologica · doi:10.1007/bf02930954 · Cited by 22
Self-citation
Cited by
Intelligent Food Packaging: A Review of Smart Sensing Technologies for Monitoring Food Quality
Yousefi, H., Su, H.-M., Imani, S. M., Alkhaldi, K., M. Filipe, C. D., & Didar, T. F. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00440 · Cited by 682
Sensors for Volatile Organic Compounds
Khatib, M., & Haick, H. (2022) · ACS Nano · doi:10.1021/acsnano.1c10827 · Cited by 533
Ghoneim, M. T., Nguyen, A., Dereje, N., Huang, J., Moore, G. C., Murzynowski, P. J., & Dagdeviren, C. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00655 · Cited by 317
Recent Advances in Sensing Applications of Graphene Assemblies and Their Composites
Tung, T. T., Nine, M. J., Krebsz, M., Pasinszki, T., Coghlan, C. J., Tran, D. N. H., & Losic, D. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201702891 · Cited by 294
Toward Biotherapeutic Product Real‐Time Quality Monitoring
Guerra, A., von Stosch, M., & Glassey, J. (2019) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2018.1524362 · Cited by 58
Metadata
- Authors
- Pospíšilová, M., Kuncová, G., & Trögl, J.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2015-09-30
- Volume
- 15
- Issue
- 10
- Pages
- 25208-25259
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2129716900
- Cited by
- 202
- References
- 5
- FWCI
- 8.18
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fiber-Optic Chemical Sensors and Fiber-Optic Bio-Sensors. https://app.cochat.ai/papers/10.3390/s151025208
- The paper
- Pospíšilová, M., Kuncová, G., & Trögl, J. (2015). Fiber-Optic Chemical Sensors and Fiber-Optic Bio-Sensors. Sensors. https://doi.org/10.3390/s151025208
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.