A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The estimation of heart rate (HR) based on wearable devices is of interest in fitness. Photoplethysmography (PPG) is a promising approach to estimate HR due to low cost; however, it is easily corrupted by motion artifacts (MA). In this work, a robust approach based on random forest is proposed for accurately estimating HR from the photoplethysmography signal contaminated by intense motion artifacts, consisting of two stages. Stage 1 proposes a hybrid method to effectively remove MA with a low computation complexity, where two MA removal algorithms are combined by an accurate binary decision algorithm whose aim is to decide whether or not to adopt the second MA removal algorithm. Stage 2 proposes a random forest-based spectral peak-tracking algorithm, whose aim is to locate the spectral peak corresponding to HR, formulating the problem of spectral peak tracking into a pattern classification problem. Experiments on the PPG datasets including 22 subjects used in the 2015 IEEE Signal Processing Cup showed that the proposed approach achieved the average absolute error of 1.65 beats per minute (BPM) on the 22 PPG datasets. Compared to state-of-the-art approaches, the proposed approach has better accuracy and robustness to intense motion artifacts, indicating its potential use in wearable sensors for health monitoring and fitness tracking.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
Linear and quadratic time-frequency signal representations
Hlawatsch, F., & Boudreaux-Bartels, G. F. (1992) · IEEE Signal Processing Magazine · doi:10.1109/79.127284 · Cited by 1,632 · cited 2×
“In other words, the features in the wavelet domain can yield a potentially more revealing picture of the temporal localization of a signal’s spectral components [26] that is not a simple combination of time and frequency information.”
BackgroundZhang, Z. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2406332 · Cited by 388 · cited 3×
“From this figure, we can see that, compared with the two groups of the latest HR estimation approaches [13–15 ,20,30,31], the To better see the performance of our proposed HR estimation approach for the 22 subjects, Figure 5 gives the Bland–Altman plot, which is used to verify agreement between the…”
MethodResultSelf-citationSkin photoplethysmography — a review
Kamal, A. A. R., Harness, J. B., Irving, G., & Mearns, A. J. (1989) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(89)90159-4 · Cited by 328
Khan, E., Al Hossain, F., Uddin, S. Z., Alam, S. K., & Hasan, M. K. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2466075 · Cited by 153
Ye, Y., Cheng, Y., He, W., Hou, M., & Zhang, Z. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2597265 · Cited by 94 · cited 5×
“Compared with the correlation coefficient-based binary decision algorithm that can only detect the linear relationship [13,14], the proposed binary decision algorithm can detect not only the linear relationship by using the correlation coefficient as one feature, but also the nonlinear relationship…”
MethodInfluentialSelf-citation
Cited by
Current progress of photoplethysmography and SPO2 for health monitoring
Tamura, T. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00097-w · Cited by 247
Motion Artifact Reduction for Wrist-Worn Photoplethysmograph Sensors Based on Different Wavelengths
Zhang, Y., Song, S., Vullings, R., Biswas, D., Simões-Capela, N., van Helleputte, N., van Hoof, C., & Groenendaal, W. (2019) · Sensors · doi:10.3390/s19030673 · Cited by 140
“These properties will be exploited in the proposed algorithm framework in Section 4.”
BackgroundHeart rate tracking in photoplethysmography signals affected by motion artifacts: a review
Ismail, S., Akram, U., & Siddiqi, I. (2021) · EURASIP Journal on Advances in Signal Processing · doi:10.1186/s13634-020-00714-2 · Cited by 101
“[42] and the author found it to be robust.”
BackgroundA Review of Methods for Non-Invasive Heart Rate Measurement on Wrist
De Pinho Ferreira, N., Gehin, C., & Massot, B. (2021) · IRBM · doi:10.1016/j.irbm.2020.04.001 · Cited by 49
Xu, K., Jiang, X., Lin, S., Dai, C., & Chen, W. (2020) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2020.2988097 · Cited by 37
“Two state-of-the-art methods (second-order Volterra filter (SOVF) [37] and SSA-based decomposition using IMU as noise [13]) with the procedure of waveform recovery were selected and compared with the proposed algorithm to judge its performance in waveform recovery.”
BackgroundMethod
Metadata
- Authors
- Ye, Y., He, W., Cheng, Y., Huang, W., & Zhang, Z.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2017-02-16
- Volume
- 17
- Issue
- 2
- Pages
- 385
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2588355695
- Cited by
- 43
- References
- 6
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.