Inertial Sensor-Based Robust Gait Analysis in Non-Hospital Settings for Neurological Disorders
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The gold standards for gait analysis are instrumented walkways and marker-based motion capture systems, which require costly infrastructure and are only available in hospitals and specialized gait clinics. Even though the completeness and the accuracy of these systems are unquestionable, a mobile and pervasive gait analysis alternative suitable for non-hospital settings is a clinical necessity. Using inertial sensors for gait analysis has been well explored in the literature with promising results. However, the majority of the existing work does not consider realistic conditions where data collection and sensor placement imperfections are imminent. Moreover, some of the underlying assumptions of the existing work are not compatible with pathological gait, decreasing the accuracy. To overcome these challenges, we propose a foot-mounted inertial sensor-based gait analysis system that extends the well-established zero-velocity update and Kalman filtering methodology. Our system copes with various cases of data collection difficulties and relaxes some of the assumptions invalid for pathological gait (e.g., the assumption of observing a heel strike during a gait cycle). The system is able to extract a rich set of standard gait metrics, including stride length, cadence, cycle time, stance time, swing time, stance ratio, speed, maximum/minimum clearance and turning rate. We validated the spatio-temporal accuracy of the proposed system by comparing the stride length and swing time output with an IR depth-camera-based reference system on a dataset comprised of 22 subjects. Furthermore, to highlight the clinical applicability of the system, we present a clinical discussion of the extracted metrics on a disjoint dataset of 17 subjects with various neurological conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · cited 1×
“To demonstrate the correlation and the agreement between the reference system and our system, we generated correlation and Bland–Altman plots [42], which is a standard method of analyzing the agreement and the differences between two measurement methods [43].”
MethodMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Multi-sensor fusion in body sensor networks: State-of-the-art and research challenges
Gravina, R., Alinia, P., Ghasemzadeh, H., & Fortino, G. (2017) · Information Fusion · doi:10.1016/j.inffus.2016.09.005 · Cited by 899
Enabling Effective Programming and Flexible Management of Efficient Body Sensor Network Applications
Fortino, G., Giannantonio, R., Gravina, R., Kuryloski, P., & Jafari, R. (2013) · IEEE Transactions on Human-Machine Systems · doi:10.1109/tsmcc.2012.2215852 · Cited by 412
Evaluation of zero-velocity detectors for foot-mounted inertial navigation systems
Skog, I., Nilsson, J.-O., & Handel, P. (2010) · 2010 International Conference on Indoor Positioning and Indoor Navigation · doi:10.1109/ipin.2010.5646936 · Cited by 213
Wearable sensor-based objective assessment of motor symptoms in Parkinson’s disease
Ossig, C., Antonini, A., Buhmann, C., Classen, J., Csoti, I., Falkenburger, B., Schwarz, M., Winkler, J., & Storch, A. (2016) · Journal of Neural Transmission · doi:10.1007/s00702-015-1439-8 · Cited by 164 · cited 2×
“Using IMUs for the purposes of gait analysis also attracts the attention of the academic community, as there are numerous studies in the literature that employ IMUs [3,4].”
BackgroundDrift Removal for Improving the Accuracy of Gait Parameters Using Wearable Sensor Systems
Takeda, R., Lisco, G., Fujisawa, T., Gastaldi, L., Tohyama, H., & Tadano, S. (2014) · Sensors · doi:10.3390/s141223230 · Cited by 84 · cited 2×
“A well-explored method for stride length estimation is to construct a geometric human locomotion model using the joint angles estimated via the IMUs [14,16,19,20].”
Method
Cited by
Qiu, S., Zhao, H., Jiang, N., Wang, Z., Liu, L., An, Y., Zhao, H., Miao, X., Liu, R., & Fortino, G. (2022) · Information Fusion · doi:10.1016/j.inffus.2021.11.006 · Cited by 671
EdgeCloudSim: An environment for performance evaluation of edge computing systems
Sonmez, C., Ozgovde, A., & Ersoy, C. (2018) · Transactions on Emerging Telecommunications Technologies · doi:10.1002/ett.3493 · Cited by 427
Self-citationNweke, H. F., Teh, Y. W., Mujtaba, G., & Al-garadi, M. A. (2019) · Information Fusion · doi:10.1016/j.inffus.2018.06.002 · Cited by 394
Steven Eyobu, O., & Han, D. S. (2018) · Sensors · doi:10.3390/s18092892 · Cited by 259
Validation of an IMU Gait Analysis Algorithm for Gait Monitoring in Daily Life Situations
Zhou, L., Tunca, C., Fischer, E., Brahms, C. M., Ersoy, C., Granacher, U., & Arnrich, B. (2020) · 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176827 · Cited by 63
Self-citation
Metadata
- Authors
- Tunca, C., Pehlivan, N., Ak, N., Arnrich, B., Salur, G., & Ersoy, C.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2017-04-11
- Volume
- 17
- Issue
- 4
- Pages
- 825
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2607487825
- Cited by
- 142
- References
- 7
- FWCI
- 5.59
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inertial Sensor-Based Robust Gait Analysis in Non-Hospital Settings for Neurological Disorders. https://app.cochat.ai/papers/10.3390/s17040825
- The paper
- Tunca, C., Pehlivan, N., Ak, N., Arnrich, B., Salur, G., & Ersoy, C. (2017). Inertial Sensor-Based Robust Gait Analysis in Non-Hospital Settings for Neurological Disorders. Sensors. https://doi.org/10.3390/s17040825
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.