Novel Flexible Wearable Sensor Materials and Signal Processing for Vital Sign and Human Activity Monitoring
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Advances in flexible electronic materials and smart textile, along with broad availability of smart phones, cloud and wireless systems have empowered the wearable technologies for significant impact on future of digital and personalized healthcare as well as consumer electronics. However, challenges related to lack of accuracy, reliability, high power consumption, rigid or bulky form factor and difficulty in interpretation of data have limited their wide-scale application in these potential areas. As an important solution to these challenges, we present latest advances in novel flexible electronic materials and sensors that enable comfortable and conformable body interaction and potential for invisible integration within daily apparel. Advances in novel flexible materials and sensors are described for wearable monitoring of human vital signs including, body temperature, respiratory rate and heart rate, muscle movements and activity. We then present advances in signal processing focusing on motion and noise artifact removal, data mining and aspects of sensor fusion relevant to future clinical applications of wearable technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Convolutional and LSTM Recurrent Neural Networks for Multimodal Wearable Activity Recognition
Ordóñez, F., & Roggen, D. (2016) · Sensors · doi:10.3390/s16010115 · Cited by 2,761
Shaffer, F., McCraty, R., & Zerr, C. L. (2014) · Frontiers in Psychology · doi:10.3389/fpsyg.2014.01040 · Cited by 1,866
A tutorial on human activity recognition using body-worn inertial sensors
Bulling, A., Blanke, U., & Schiele, B. (2014) · ACM Computing Surveys · doi:10.1145/2499621 · Cited by 1,668 · cited 1×
“Decision-level fusion is the process of combining the decisions generated from multiple sensors individually [92].”
BackgroundMonitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408 · cited 1×
“Other important limitations include the limited anatomical locations used for sensor placement, motion artifacts and handling/interpreting the large volume of generated data [4].”
BackgroundSoft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin
Xu, S., Zhang, Y., Jia, L., Mathewson, K. E., Jang, K.-I., Kim, J., Fu, H., Huang, X., Chava, P., Wang, R., et al. (2014) · Science · doi:10.1126/science.1250169 · Cited by 1,199 · cited 3×
“[12] incorporated two electrodes in a flexible band alongside with other necessary circuits to monitor ECG (Figure 3c,d).”
MethodInfluentialWearable and Highly Sensitive Graphene Strain Sensors for Human Motion Monitoring
Wang, Y., Wang, L., Yang, T., Li, X., Zang, X., Zhu, M., Wang, K., Wu, D., & Zhu, H. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201400379 · Cited by 1,085
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
Multi-sensor fusion in body sensor networks: State-of-the-art and research challenges
Gravina, R., Alinia, P., Ghasemzadeh, H., & Fortino, G. (2017) · Information Fusion · doi:10.1016/j.inffus.2016.09.005 · Cited by 899
Sensitive, High-Strain, High-Rate Bodily Motion Sensors Based on Graphene–Rubber Composites
Boland, C. S., Khan, U., Backes, C., O’Neill, A., McCauley, J., Duane, S., Shanker, R., Liu, Y., Jurewicz, I., Dalton, A. B., et al. (2014) · ACS Nano · doi:10.1021/nn503454h · Cited by 793
Fusion of Smartphone Motion Sensors for Physical Activity Recognition
Shoaib, M., Bosch, S., Incel, O., Scholten, H., & Havinga, P. (2014) · Sensors · doi:10.3390/s140610146 · Cited by 552 · cited 1×
“Many real-world applications involve multiple sensors whose data need to be jointly analyzed [88,89].”
BackgroundSurface Electromyography : Physiology, Engineering, and Applications
(2016) · doi:10.1002/9781119082934 · Cited by 462
Considerations for the measurement of core, skin and mean body temperatures
Taylor, N. A. S., Tipton, M. J., & Kenny, G. P. (2014) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2014.10.006 · Cited by 420 · cited 1×
“On the other hand, many conditions such as late stage infectious diseases, blood depletion conditions and application of drugs and toxins may lead to a noticeable decrease in body temperature [19,20].”
BackgroundA wireless wearable ECG sensor for long-term applications
Nemati, E., Deen, M., & Mondal, T. (2012) · IEEE Communications Magazine · doi:10.1109/mcom.2012.6122530 · Cited by 418
Fitbit®: An accurate and reliable device for wireless physical activity tracking
Diaz, K. M., Krupka, D. J., Chang, M. J., Peacock, J., Ma, Y., Goldsmith, J., Schwartz, J. E., & Davidson, K. W. (2015) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.03.038 · Cited by 405
A review of biometric technology along with trends and prospects
Unar, J. A., Seng, W. C., & Abbasi, A. (2014) · Pattern Recognition · doi:10.1016/j.patcog.2014.01.016 · Cited by 404 · cited 1×
“The extraction of application-specific features should also take into account the domain knowledge, such as fiducial points of PPG signals and specific iris features [76,77].”
BackgroundStretchable Graphene Thermistor with Tunable Thermal Index
Yan, C., Wang, J., & Lee, P. S. (2015) · ACS Nano · doi:10.1021/nn507441c · Cited by 359 · cited 5×
“Flexible wearable temperature sensors: (a) stretchable graphene thermistor with AgNW (Ag nanowire) electrodes as contacts at relaxed state; (b) its I-V curves when temperature changing from 30 to 100 ◦C; and (c) transient response to changing temperature at 0 and 50% strains (Reprinted with permission [5].”
BackgroundInfluentialEl-Amrawy, F., & Nounou, M. I. (2015) · Healthcare Informatics Research · doi:10.4258/hir.2015.21.4.315 · Cited by 287
Pittig, A., Arch, J. J., Lam, C. W. R., & Craske, M. G. (2013) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2012.10.012 · Cited by 255 · cited 1×
“On the other hand, it has been recently observed that heart rhythm is not homogenous if we measure it over longer periods of time and it has periods of complex changes and stabilities depending on physical and mental conditions [27,28].”
BackgroundA survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Artifact-resistant power-efficient design of finger-ring plethysmographic sensors
Rhee, S., Yang, B.-H., & Asada, H. H. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930904 · Cited by 235
Wearable silver nanowire dry electrodes for electrophysiological sensing
Myers, A. C., Huang, H., & Zhu, Y. (2015) · RSC Advances · doi:10.1039/c4ra15101a · Cited by 231 · cited 3×
“Copyright 2014, The American Association for the Advancement of Science); (c) AgNW dry electrodes and their placement on the subject’s leg muscle, in parallel with conventional wet-Ag/AgCl electrodes; and (d) EMG data recorded by wet-Ag/AgCl electrodes and AgNW dry electrodes (Reprinted with permission [54].”
BackgroundInfluentialAn integrated data mining approach to real-time clinical monitoring and deterioration warning
Mao, Y., Chen, W., Chen, Y., Lu, C., Kollef, M., & Bailey, T. (2012) · Proceedings of the 18th ACM SIGKDD international conference on Knowledge discovery and data mining · doi:10.1145/2339530.2339709 · Cited by 76
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
The Importance of Respiratory Rate Monitoring: From Healthcare to Sport and Exercise
Nicolò, A., Massaroni, C., Schena, E., & Sacchetti, M. (2020) · Sensors · doi:10.3390/s20216396 · Cited by 440
Reviews of wearable healthcare systems: Materials, devices and system integration
Lou, Z., Wang, L., Jiang, K., Wei, Z., & Shen, G. (2020) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2019.100523 · Cited by 385
Jang, Y., Kim, S. M., Spinks, G. M., & Kim, S. J. (2020) · Advanced Materials · doi:10.1002/adma.201902670 · Cited by 274
Novel Tactile Sensor Technology and Smart Tactile Sensing Systems: A Review
Zou, L., Ge, C., Wang, Z., Cretu, E., & Li, X. (2017) · Sensors · doi:10.3390/s17112653 · Cited by 271
Self-citation
Metadata
- Authors
- Servati, A., Zou, L., Wang, Z., Ko, F., & Servati, P.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2017-07-13
- Volume
- 17
- Issue
- 7
- Pages
- 1622
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2734438923
- Cited by
- 106
- References
- 22
- FWCI
- 4.89
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.