The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
A Flexible Temperature Sensor Based on Reduced Graphene Oxide for Robot Skin Used in Internet of Things
Open accessAbstract
Flexible electronics, which can be distributed on any surface we need, are highly demanded in the development of Internet of Things (IoT), robot technology and electronic skins. Temperature is a fundamental physical parameter, and it is an important indicator in many applications. Therefore, a flexible temperature sensor is required. Here, we report a simple method to fabricate three lightweight, low-cost and flexible temperature sensors, whose sensitive materials are reduced graphene oxide (r-GO), single-walled carbon nanotubes (SWCNTs) and multi-wall carbon nanotubes (MWCNTs). By comparing linearity, sensitive and repeatability, we found that the r-GO temperature sensor had the most balanced performance. Furthermore, the r-GO temperature sensor showed good mechanical properties and it could be bent in different angles with negligible resistance change. In addition, the performance of the r-GO temperature sensor remained stable under different kinds of pressure and was unaffected by surrounding environments, like humidity or other gases, because of the insulating layer on its sensitive layer. The easy-fabricated process and economy, together with the remarkable performance of the r-GO temperature sensor, suggest that it is suitable for use as a robot skin or used in the environment of IoT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291 · cited 1×
“Humans have great expectations for robots and hope they can help people do things like collection, transmission, and processing of information that humans cannot do in harsh environments [18].”
BackgroundHammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396 · cited 1×
“Carbon-based temperature sensitive materials, including carbon black [14], graphene [15], carbon fiber, and carbon nanotubes [16] are attracting more and more attention because of their excellent mechanical and electrical properties [17].”
BackgroundTrung, T. Q., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504244 · Cited by 2,160 · cited 1×
“Carbon-based temperature sensitive materials, including carbon black [14], graphene [15], carbon fiber, and carbon nanotubes [16] are attracting more and more attention because of their excellent mechanical and electrical properties [17].”
BackgroundMultifunctional wearable devices for diagnosis and therapy of movement disorders
Son, D., Lee, J., Qiao, S., Ghaffari, R., Kim, J., Lee, J. E., Song, C., Kim, S. J., Lee, D. J., Jun, S. W., et al. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.38 · Cited by 1,462
Choong, C., Shim, M., Lee, B., Jeon, S., Ko, D., Kang, T., Bae, J., Lee, S. H., Byun, K., Im, J., et al. (2014) · Advanced Materials · doi:10.1002/adma.201305182 · Cited by 1,252
Ultrathin conformal devices for precise and continuous thermal characterization of human skin
Webb, R. C., Bonifas, A. P., Behnaz, A., Zhang, Y., Yu, K. J., Cheng, H., Shi, M., Bian, Z., Liu, Z., Kim, Y.-S., et al. (2013) · Nature Materials · doi:10.1038/nmat3755 · Cited by 1,229
Thermal properties of graphene and multilayer graphene: Applications in thermal interface materials
Shahil, K. M. F., & Balandin, A. A. (2012) · Solid State Communications · doi:10.1016/j.ssc.2012.04.034 · Cited by 829
Flexible and Stretchable Devices
Bao, Z., & Chen, X. (2016) · Advanced Materials · doi:10.1002/adma.201601422 · Cited by 466
Ultraflexible, large-area, physiological temperature sensors for multipoint measurements
Yokota, T., Inoue, Y., Terakawa, Y., Reeder, J., Kaltenbrunner, M., Ware, T., Yang, K., Mabuchi, K., Murakawa, T., Sekino, M., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1515650112 · Cited by 382
Toward Flexible and Wearable Human‐Interactive Health‐Monitoring Devices
Takei, K., Honda, W., Harada, S., Arie, T., & Akita, S. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400546 · Cited by 371
Stretchable Graphene Thermistor with Tunable Thermal Index
Yan, C., Wang, J., & Lee, P. S. (2015) · ACS Nano · doi:10.1021/nn507441c · Cited by 359
Self-citationReview of Flexible Temperature Sensing Networks for Wearable Physiological Monitoring
Li, Q., Zhang, L., Tao, X., & Ding, X. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201601371 · Cited by 354
Self-citationHarada, S., Kanao, K., Yamamoto, Y., Arie, T., Akita, S., & Takei, K. (2014) · ACS Nano · doi:10.1021/nn506293y · Cited by 350 · cited 2×
“25% ◦C−1 1~2 s [27] single-walled carbon nanotubes (SWCNT) 0–80 Yes / / [28] Ag 20–60 Yes 0.”
Bioinspired Engineering of Thermal Materials
Tao, P., Shang, W., Song, C., Shen, Q., Zhang, F., Luo, Z., Yi, N., Zhang, D., & Deng, T. (2015) · Advanced Materials · doi:10.1002/adma.201401449 · Cited by 311
An All-Silk-Derived Dual-Mode E-skin for Simultaneous Temperature–Pressure Detection
Wang, C., Xia, K., Zhang, M., Jian, M., & Zhang, Y. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b13356 · Cited by 277
Gao, L., Zhang, Y., Malyarchuk, V., Jia, L., Jang, K.-I., Chad Webb, R., Fu, H., Shi, Y., Zhou, G., Shi, L., et al. (2014) · Nature Communications · doi:10.1038/ncomms5938 · Cited by 272
High-temperature quenching of electrical resistance in graphene interconnects
Shao, Q., Liu, G., Teweldebrhan, D., & Balandin, A. A. (2008) · Applied Physics Letters · doi:10.1063/1.2927371 · Cited by 254
Self-citationTemperature sensor realized by inkjet printing process on flexible substrate
Dankoco, M. D., Tesfay, G. Y., Benevent, E., & Bendahan, M. (2016) · Materials Science and Engineering: B · doi:10.1016/j.mseb.2015.11.003 · Cited by 246
Semiconducting nature of the oxygen-adsorbed graphene sheet
Ito, J., Nakamura, J., & Natori, A. (2008) · Journal of Applied Physics · doi:10.1063/1.2939270 · Cited by 235
Flexible Temperature Sensor Array Based on a Graphite-Polydimethylsiloxane Composite
Shih, W.-P., Tsao, L.-C., Lee, C.-W., Cheng, M.-Y., Chang, C., Yang, Y.-J., & Fan, K.-C. (2010) · Sensors · doi:10.3390/s100403597 · Cited by 226
Soft Thermal Sensor with Mechanical Adaptability
Yang, H., Qi, D., Liu, Z., Chandran, B. K., Wang, T., Yu, J., & Chen, X. (2016) · Advanced Materials · doi:10.1002/adma.201602994 · Cited by 225
A patterned single layer graphene resistance temperature sensor
Davaji, B., Cho, H. D., Malakoutian, M., Lee, J.-K., Panin, G., Kang, T. W., & Lee, C. H. (2017) · Scientific Reports · doi:10.1038/s41598-017-08967-y · Cited by 171
Kanao, K., Harada, S., Yamamoto, Y., Honda, W., Arie, T., Akita, S., & Takei, K. (2015) · RSC Advances · doi:10.1039/c5ra03110a · Cited by 148
Reduced graphene oxide filled cellulose films for flexible temperature sensor application
Sadasivuni, K. K., Kafy, A., Kim, H. C., Ko, H., Mun, S., & Kim, J. (2015) · Synthetic Metals · doi:10.1016/j.synthmet.2015.05.018 · Cited by 148
In Situ Monitoring of Temperature inside Lithium-Ion Batteries by Flexible Micro Temperature Sensors
Lee, C., Lee, S.-J., Tang, M.-S., & Chen, P.-C. (2011) · Sensors · doi:10.3390/s111009942 · Cited by 134
Thermal volume expansion in polymeric PTC composites: a theoretical approach
Yi, X., Shen, L. H., & Pan, Y. (2001) · Composites Science and Technology · doi:10.1016/s0266-3538(00)00191-3 · Cited by 78
Highly sensitive flexible tactile sensors based on microstructured multiwall carbon nanotube arrays
Li, X., Huang, W., Yao, G., Gao, M., Wei, X., Liu, Z., Zhang, H., Gong, T., & Yu, B. (2016) · Scripta Materialia · doi:10.1016/j.scriptamat.2016.10.037 · Cited by 65
Husain, M., & Kennon, R. (2013) · Fibers · doi:10.3390/fib1010002 · Cited by 60
Lee, C., Lee, C.-Y., Weng, F.-B., et al. (2010) · Journal of Power Sources · doi:10.1016/j.jpowsour.2010.06.051 · Cited by 49
Temperature Sensor in a Flexible Substrate
Ahmed, M., Chitteboyina, M. M., Butler, D. P., & Çelik‐Butler, Z. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2166064 · Cited by 48
Cited by
Flexible temperature sensors: A review
Arman Kuzubasoglu, B., & Kursun Bahadir, S. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2020.112282 · Cited by 369
Su, Y., Ma, C., Chen, J., Wu, H., Luo, W., Peng, Y., Luo, Z., Li, L., Tan, Y., Omisore, O. M., et al. (2020) · Nanoscale Research Letters · doi:10.1186/s11671-020-03428-4 · Cited by 287
Khan, S., Ali, S., & Bermak, A. (2019) · Sensors · doi:10.3390/s19051230 · Cited by 253
Homecare robotic systems for healthcare 4.0: visions and enabling technologies
Yang, G., Pang, Z., Jamal Deen, M., Dong, M., Zhang, Y.-T., Lovell, N., & Rahmani, A. M. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.2990529 · Cited by 213
Metadata
- Authors
- Liu, G., Tan, Q., Kou, H., Zhang, L., Wang, J., Lv, W., Dong, H., & Xiong, J.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2018-05-02
- Volume
- 18
- Issue
- 5
- Pages
- 1400
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2802386635
- Cited by
- 260
- References
- 30
- FWCI
- 8.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.