The DOI matches its Crossref record; 62 of the 63 references it cites were found in a registry or an index.
Investigation of the Impact of Infrared Sensors on Core Body Temperature Monitoring by Comparing Measurement Sites
Open accessAbstract
Many types of thermometers have been developed to measure body temperature. Infrared thermometers (IRT) are fast, convenient and ease to use. Two types of infrared thermometers are uses to measure body temperature: tympanic and forehead. With the spread of COVID-19 coronavirus, forehead temperature measurement is used widely to screen people for the illness. The performance of this type of device and the criteria for screening are worth studying. This study evaluated the performance of two types of tympanic infrared thermometers and an industrial infrared thermometer. The results showed that these infrared thermometers provide good precision. A fixed offset between tympanic and forehead temperature were found. The measurement values for wrist temperature show significant offsets with the tympanic temperature and cannot be used to screen fevers. The standard operating procedure (SOP) for the measurement of body temperature using an infrared thermometer was proposed. The suggestion threshold for the forehead temperature is 36 °C for screening of fever. The body temperature of a person who is possibly ill is then measured using a tympanic infrared thermometer for the purpose of a double check.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, the determination of core body temperature by indirect measurement can be accomplished using several signal processing methods [144,145].”
From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [144]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Infrared ear thermometry compared with rectal thermometry in children: a systematic review
Craig, J. V., Lancaster, G., Taylor, S., Williamson, P. R., & Smyth, R. L. (2002) · The Lancet · doi:10.1016/s0140-6736(02)09783-0 · Cited by 337
Validity and Reliability of Devices That Assess Body Temperature During Indoor Exercise in the Heat
Ganio, M. S., Brown, C. M., Casa, D. J., Becker, S. M., Yeargin, S. W., McDermott, B. P., Boots, L. M., Boyd, P. W., Armstrong, L. E., & Maresh, C. M. (2009) · Journal of Athletic Training · doi:10.4085/1062-6050-44.2.124 · Cited by 201
Comparison of ear-based, bladder, oral, and axillary methods for core temperature measurement
Erickson, R. S., & Kirklin, S. K. (1993) · Critical Care Medicine · doi:10.1097/00003246-199310000-00022 · Cited by 190
Infrared camera assessment of skin surface temperature—Effect of emissivity
Bernard, V., Staffa, E., Mornstein, V., & Bourek, A. (2013) · Physica Medica · doi:10.1016/j.ejmp.2012.09.003 · Cited by 177
Accuracy and Precision of Noninvasive Temperature Measurement in Adult Intensive Care Patients
Lawson, L. L., Bridges, E. J., Ballou, I., Eraker, R., Greco, S. A., Shively, J., & Sochulak, V. (2007) · American Journal of Critical Care · doi:10.4037/ajcc2007.16.5.485 · Cited by 154
Yao, Y., Lian, Z., Liu, W., & Shen, Q. (2007) · Indoor and Built Environment · doi:10.1177/1420326x07084291 · Cited by 110
Insufficiency in a New Temporal-Artery Thermometer for Adult and Pediatric Patients
Suleman, M.-I., Doufas, A. G., Akça, O., Ducharme, M. B., & Sessler, D. I. (2002) · Anesthesia & Analgesia · doi:10.1097/00000539-200207000-00012 · Cited by 105
Liu, C., Chang, R., & Chang, W.-C. (2004) · Infection Control and Hospital Epidemiology · doi:10.1086/502351 · Cited by 94
Clinical accuracy of a non‐contact infrared skin thermometer in paediatric practice
Terán, C. G., Torrez‐Llanos, J., Teran‐Miranda, T. E., Balderrama, C. R., Shah, N. S., & Villarroel, P. (2011) · Child Care Health and Development · doi:10.1111/j.1365-2214.2011.01264.x · Cited by 90
Reliability of an infrared forehead skin thermometer for core temperature measurements
Kistemaker, J. A., DenHartog, E., & Daanen, H. A. M. (2006) · Journal of Medical Engineering & Technology · doi:10.1080/03091900600711381 · Cited by 87
Research works printed but not linked: 2
- Berksoy, 2018, Comparison of infrared tympanic, non-contact infrared skin, and axillary thermometer to rectal temperature measurements in a pediatric emergency observation unit, Int. J. Clin. Exp. Med., 11, 567
- Myers, R.H. (1990). Classical and Modern Regression with Applications, Duxbury Press. [2nd ed.].
Cited by
Sorted by citations
Items 101–139 of 139
do Nascimento, A. S., Lemos, C. D. S., Biachi, F. B., de Lyra, F. R. S., Gnatta, J. R., & Poveda, V. D. B. (2024) · Revista Latino-Americana de Enfermagem · doi:10.1590/1518-8345.6873.4144 · Cited by 1
Khlifi, M., Jebabli, N., Ouerghi, N., Yağın, F. H., Dutta, A. K., Alwhaibi, R. M., & Bouassida, A. (2025) · Medicina · doi:10.3390/medicina61071173 · Cited by 1
Temperature Field Analysis of Novel Die Bonding Stage for MEMS Thermopile
Li, Y., Lu, X., & Chen, Z. (2023) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.23827 · Cited by 1
Švantner, M., Lang, V., Skála, J., Kohlschütter, T., Šroub, J., Muzika, L., Klepáček, J., & Honner, M. (2023) · doi:10.3390/engproc2023051017 · Cited by 1
Tuladhar, L. R., Shrestha, S., Ghimire, N., Acharya, N., & Tamrakar, E. (2021) · Nepal Medical College Journal · doi:10.3126/nmcj.v23i1.36224 · Cited by 1
Procedimiento para el uso de pirómetros durante la pandemia por COVID-19
Wilches-Visbal, J. H., Castillo-Pedraza, M. C., & Véliz, D. G. A. (2020) · Archivos de Medicina (Manizales) · doi:10.30554/archmed.21.1.3973.2021 · Cited by 1
Too Hot to Enter: Investigating Users’ Attitudes Toward Thermoscanners in COVID Times
Bettelli, A., Orso, V., Pernice, G. F. A., Corradini, F., Fabbri, L., & Gamberini, L. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-78468-3_17 · Cited by 1
Survey: Vitals Screening Techniques for a Safer EnvironmentPreprint
Baig, S., & Elbadry, M. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2104.12816
Campus Epidemic-Prevention System
Hsueh, Y., Su, P.-C., Ke, M.-T., Huang, H.-L., Chiang, M.-X., Chiang, M.-H., & Su, B.-Y. (2021) · IEEE Consumer Electronics Magazine · doi:10.1109/mce.2021.3079633
Information System for Automated Monitoring of Patients in Hospital Intermediate Care Units
Soto-Cordova, M. M., Sotomayor-Parian, R. M., & Palma-Soto, S. (2021) · Congreso Internacional de Innovación y Tendencias en Ingeniería (CONIITI) · doi:10.1109/coniiti53815.2021.9619642
CheckING: An IoT Device for COVID-19 Monitoring and Prevention
Medved, J., Rodríguez, H., Luca, M. A. D., Grimaudo, N., Cymberknop, L. J., & Armentano, R. L. (2021) · Workshop on Information Processing and Control · doi:10.1109/rpic53795.2021.9648468
Sports Ground Audience Health Monitoring System [For COVID-19] Using Smart Wireless Sensor Network
Dharshini, V., M, A. S., Ashwin, R., & Usha, A. (2021) · Advances in parallel computing · doi:10.3233/apc210295
Auto Adjustment Pengukuran Temperatur Tubuh Tanpa Sentuh Berbasis Sensor Deret Thermopile Infrared
Nuryanti, N., Bhaskoro, S. B., & Fauzia, D. N. (2021) · JTERA (Jurnal Teknologi Rekayasa) · doi:10.31544/jtera.v6.i2.2021.263-272
Rancang Bangun Alat Theraphy Infrared Berbasis STM 32 Untuk Deteksi Nyeri Otot
Alfita, R., Ibadillah, A. F., Nahari, R. V., Wibisono, K. A., & Aprilyanto, H. W. (2022) · Jurnal Teknologi Elektro · doi:10.22441/jte.2022.v13i1.007
IoT-Based COVID-19 SOP Testing and Monitoring System for Businesses and Public Offices
Harisha, K. S. (2021) · INTERANTIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENT · doi:10.55041/ijsrem11666
Irawati, I. D., Alfaruq, A., Hadiyoso, S., & Ramadan, D. N. (2022) · Lecture notes in electrical engineering · doi:10.1007/978-981-19-1804-9_2
Rosanti, N. M., Rahardjo, D. T., & Harjunowibowo, D. (2022) · Jurnal Materi dan Pembelajaran Fisika · doi:10.20961/jmpf.v12i1.60399
Yu, S., Zhou, H., Wang, W., & Wang, Z. (2022) · Optics Young Scientist Summit (OYSS) · doi:10.1117/12.2626262
Rastogi, V., Kumar, V., Dubey, S. K., Khan, G. S., & Shakher, C. (2022) · Optical Technology and Measurement for Industrial Applications Conference (OPTM) · doi:10.1117/12.2660156
COMPUTATION STUDY OF JATROPHA CURCAS L. LEAVES
Safitri, H., Hijri, F., Khairi, M., Zahra, F. A., & Marsila, N. (2022) · EPICENTRUM · doi:10.54482/epicentrum.v1i01.48
Automatic Environment Protection Using Mixed Signal Processor For Covid-19
Tamilarasi, K., Shalini, B. B., Soundarya, M. J., Sivapavina, J., & Sowmiya, E. (2022) · International Interdisciplinary Humanitarian Conference for Sustainability (IIHC) · doi:10.1109/iihc55949.2022.10060320
Automatic temperature detector to mitigate the spread of COVID-19
Ibnugraha, P. D., Handayani, R. P., & NonAlinsavath, K. (2023) · JURNAL INFOTEL · doi:10.20895/infotel.v15i1.847
Research on bionic flower interaction technology based on linkage mechanism
Cai, D., & Zhang, S. (2023) · Journal of Computational Methods in Sciences and Engineering · doi:10.3233/jcm-226776
Facial Recognition and Thermal Imaging: A Cost-Effective Solution for Covid-19 Detection
Embong, A. H., Ambotang, A. S., & Hamid, S. B. A. (2023) · Journal of Integrated and Advanced Engineering (JIAE) · doi:10.51662/jiae.v3i2.105
Evaluation of Infrared Thermometer on Human Health – A Review
Kombo, H. Z., Mehdi, S., Krishna, K. L., & Roohi, T. F. (2023) · Research Journal of Pharmacy and Technology · doi:10.52711/0974-360x.2023.00730
Orkun, N., & Eşer, İ. (2023) · Nigerian Journal of Clinical Practice · doi:10.4103/njcp.njcp_389_22
Bameri, M. M., Abolhassani, M., Bameri, M. M., Shafaghi, S., Ghorbani, F., & Shafaghi, M. (2023) · Journal of Electronics Electromedical Engineering and Medical Informatics · doi:10.35882/jeeemi.v5i4.329
Android Application for Automatic Door Control System using Body Temperature Measuring Sensor
Iskandar, D., Nugroho, E. W., Wahyudi, F., Kusuma, J. C., & Ramadhani, Z. (2023) · International Journal of Computer and Information System (IJCIS) · doi:10.29040/ijcis.v4i4.139
Dogan, S., & Avşar, G. (2024) · Journal of Nursing Measurement · doi:10.1891/jnm-2023-0035
do Nascimento, A. S., Lemos, C. D. S., Biachi, F. B., de Lyra, F. R. S., Gnatta, J. R., & Poveda, V. D. B. (2024) · Revista Latino-Americana de Enfermagem · doi:10.1590/1518-8345.6873.4142
Morello, R. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3443314
Tambunan, E. S., Ningsih, R., & Susana, E. (2024) · Journal of Neonatal Nursing · doi:10.1016/j.jnn.2024.10.002
Bio-Signal Acquisition System for Psychological Stress Classification
Rahman, D. M., Permana, A. F., Sakanti, M. M., Adristi, C., Luo, W., & Kuncoro, C. B. D. (2024) · International Conference on Information and Communication Technology Convergence (ICTC) · doi:10.1109/ictc62082.2024.10827237
Fu, J., Xiong, F., Gao, Q., Deng, S., Wang, J., & Li, S. (2025) · Springer eBooks · doi:10.1007/978-981-96-8646-9_8
Evaluation of Human Body Temperature Measurements with Infrared Thermography in the Ear Region
Önder, D., & Vardarli, E. (2025) · Türkiye Sağlık Enstitüleri Başkanlığı Dergisi · doi:10.4274/jhit.galenos.2025.02996
Review: A Significant Impact of Sensors in Fueling the Rise of Digital Metrology and Industry 4.0
Kumar, V., Chandra, V., Kumar, P., V, Gupta, A. K., & Khandey, U. (2026) · Lecture notes in mechanical engineering · doi:10.1007/978-981-96-8516-5_16
Marwanti, E., Kariasa, I. M., & Maria, R. (2026) · Media Keperawatan Indonesia · doi:10.26714/mki.9.1.2026.81-92
Ghailassi, I. E., Razak, N. A. A., & Osman, N. A. A. (2026) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119261465864
Metadata
- Authors
- Chen, H.-Y., Chen, A., & Chen, C.
- Affiliations
- University of California San Diego (US)
- National Chung Hsing University (TW)
- Corresponding author
- Chen, Chiachung
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-05-19
- Volume
- 20
- Issue
- 10
- Pages
- 2885
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC7284737
- OpenAlex
- W3025566666
- Cited by
- 139
- References
- 63
- Citations by year
- 2026: 6 · 2025: 11 · 2024: 17 · 2023: 20 · 2022: 28 · 2021: 42 · 2020: 15
- FWCI
- 12.78
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Ministry of Science and Technology, Taiwan (MOST107-2313-B005-012)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Thermal Regulation in Medicine
- Keywords
- infrared thermometer, core body temperature, tympanic temperature, forehead temperature, wrist temperature, fever screening, COVID-19 pandemic, measurement site comparison, standard operating procedures, temperature measurement accuracy
- MeSH terms
- COVID-19, Body Temperature, Fever, Forehead, Humans, Infrared Rays, Pneumonia, Viral, Thermometers, Coronavirus Infections, Pandemics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review