Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 35

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Development Perspective of Bioelectrocatalysis-Based Biosensors

Adachi, Taiki, Kitazumi, Yuki, Shirai, Osamu, Kano, Kenji·2020·Sensors

Published version of a preprint

Abstract

Bioelectrocatalysis provides the intrinsic catalytic functions of redox enzymes to nonspecific electrode reactions and is the most important and basic concept for electrochemical biosensors. This review starts by describing fundamental characteristics of bioelectrocatalytic reactions in mediated and direct electron transfer types from a theoretical viewpoint and summarizes amperometric biosensors based on multi-enzymatic cascades and for multianalyte detection. The review also introduces prospective aspects of two new concepts of biosensors: mass-transfer-controlled (pseudo)steady-state amperometry at microelectrodes with enhanced enzymatic activity without calibration curves and potentiometric coulometry at enzyme/mediator-immobilized biosensors for absolute determination.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s20174826

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Research works printed but not linked: 127

  1. Bartlett, P.N. (2008). Bioelectrochemistry: Fundamentals, Experimental Techniques and Applications, John Wiley & Sons. · DOI
  2. Heller, 1992, Electrical Connection of Enzyme Redox Centers to Electrodes, J. Phys. Chem., 96, 3579, 10.1021/j100188a007 · DOI · Paper page
  3. Durst, 1999, Electrochemical Biosensors: Recommended Definitions and Classification, Pure Appl. Chem., 71, 2333, 10.1351/pac199971122333 · DOI · Paper page
  4. Armstrong, 2011, Reversibility and Efficiency in Electrocatalytic Energy Conversion and Lessons from Enzymes, Proc. Natl. Acad. Sci. USA, 108, 14049, 10.1073/pnas.1103697108 · DOI · Paper page
  5. Ranava, 2014, Biohydrogen for a New Generation of H2/O2 Biofuel Cells: A Sustainable Energy Perspective, ChemElectroChem, 1, 1724, 10.1002/celc.201402249 · DOI
  6. Fourmond, 2017, Modelling the Voltammetry of Adsorbed Enzymes and Molecular Catalysts, Curr. Opin. Electrochem., 1, 110, 10.1016/j.coelec.2016.11.002 · DOI
  7. Martinkova, 2017, Main Streams in the Construction of Biosensors and Their Applications, Int. J. Electrochem. Sci., 12, 7386, 10.20964/2017.08.02 · doi:10.20964/2017.08.02
  8. Bollella, 2018, Enzyme Based Amperometric Biosensors, Curr. Opin. Electrochim., 10, 157, 10.1016/j.coelec.2018.06.003 · DOI · Paper page
  9. Kano, 2019, Fundamentals and Applications of Redox Enzyme-Functionalized Electrode Reactions, Electrochemistry, 87, 301, 10.5796/electrochemistry.19-6-E2676 · doi:10.5796/electrochemistry.19-6-e2676
  10. Kucherenko, 2019, Advances in Nanomaterial Application in Enzyme-Based Electrochemical Biosensors, Nanoscale Adv., 1, 4560, 10.1039/C9NA00491B · DOI · Paper page
  11. Ngyen, H.H., Lee, S.H., Lee, U.J., Fermin, C.D., and Kim, M. (2019). Immobilized Enzymes in Biosensor Applications. Materials, 12. · DOI · Paper page
  12. Pinyou, 2019, Enzyme-Modified Electrodes for Biosensors and Biofuel Cells, Mater. Horiz., 6, 1336, 10.1039/C9MH00013E · DOI
  13. Bollella, P., and Katz, E. (2020). Enzyme-Based Biosensors: Tackling Electron Transfer Issues. Sensors, 20. · DOI · Paper page
  14. Willner, 1997, Electrical Contact of Redox Enzyme Layers Associated with Electrodes; Routes to Amperometric Biosensors, Electroanalysis, 9, 965, 10.1002/elan.1140091302 · DOI · Paper page
  15. Barton, 2004, Enzymatic Biofuel Cells for Implantable and Microscale Devices, Chem. Rev., 104, 4867, 10.1021/cr020719k · DOI · Paper page
  16. Cracknell, 2008, Enzymes as Working or Inspirational Electrocatalysts for Fuel Cells and Electrolysis, Chem. Rev., 108, 2439, 10.1021/cr0680639 · DOI · Paper page
  17. Meredith, 2012, Biofuel Cells; Enhanced Enzymatic Bioelectrocatalysis, Annu. Rev. Anal. Chem., 5, 157, 10.1146/annurev-anchem-062011-143049 · DOI · Paper page
  18. Mazurenko, 2017, Recent Developments in High Surface Area Bioelectrodes for Enzymatic Fuel Cells, Curr. Opin. Electrochem., 5, 74, 10.1016/j.coelec.2017.07.001 · DOI
  19. Mano, 2018, O2 Reduction in Enzymatic Biofuel Cells, Chem. Rev., 118, 2392, 10.1021/acs.chemrev.7b00220 · DOI · Paper page
  20. Krieg, 2014, Reactor Concepts for Bioelectrochemical Syntheses and Energy Conversion, Trends Biotechnol., 32, 645, 10.1016/j.tibtech.2014.10.004 · doi:10.1016/j.tibtech.2014.10.004
  21. Milton, 2017, Enzymatic Bioelectrosynthetic Ammonia Production: Recent Electrochemistry of Nitrogenase, Nitrate Reductase, and Nitrite Reductase, ChemPlusChem, 82, 513, 10.1002/cplu.201600442 · DOI
  22. Shleev, 2017, Biosupercapacitors, Curr. Opin. Electrochem., 5, 226, 10.1016/j.coelec.2017.09.023 · DOI
  23. Dutton, 1978, Redox Potentiometry: Determination of Midpoint Potentials of Oxidation-Reduction Components of Biological Electron-Transfer Systems, Methods Enzymol., 54, 411, 10.1016/S0076-6879(78)54026-3 · DOI · Paper page
  24. Scheller, 1987, Enzyme Electrodes and Their Application, Phil. Trans. R. Lond. B, 316, 85, 10.1098/rstb.1987.0019 · DOI
  25. Scheller, 1989, Research and Development of Biosensors, Analyst, 114, 653, 10.1039/AN9891400653 · doi:10.1039/an9891400653
  26. Pessoa, 2003, Direct Electron Transfer: An Approarch for Electrochemical Biosensors with Higher Selectivity and Sensitivity, J. Braz. Chem. Soc., 14, 230, 10.1590/S0103-50532003000200008 · DOI · Paper page
  27. Bertrand, 2008, Direct Electrochemistry of Redox Enzymes as Tool for Mechanistic Studies, Chem. Rev., 108, 2379, 10.1021/cr0680742 · DOI · Paper page
  28. Milton, 2017, Direct Enzymatic Bioelectrocatalysis: Differentiating between Myth and Reality, J. R. Soc. Interface, 14, 20170253, 10.1098/rsif.2017.0253 · DOI · Paper page
  29. Adachi, T., Kitazumi, Y., Shirai, O., and Kano, K. (2020). Direct Electron Transfer-Type Bioelectrocatalysis of Redox Enzymes at Nanostructured Electrodes. Catalysts, 10. · doi:10.20944/preprints202002.0031.v1
  30. Kitazumi, Y., Shirai, O., and Kano, K. (2020). Significance of Nanostructures of an Electrode Surface in Direct Electron Transfer-Type Bioelectrocatalysis of Redox Enzymes, in Novel Catalyst Materials for Bioelectrochemical Systems: Fundamentals and Applications, ACS Publications. · doi:10.1021/bk-2020-1342.ch007
  31. Hooda, 2018, Recent Trends and Perspectives in Enzyme Based Biosensor Development for the Screening of Triglycerides: A Comprehensive Review, Artif. Cells Nanomed. Biotechnol., 46, 626, 10.1080/21691401.2018.1465946 · DOI
  32. Semenova, 2020, Towards One-Step Design of Tailored Enzymatic Nanobiosensors, Analyst, 145, 1014, 10.1039/C9AN01745C · DOI
  33. Pilas, J., Yazici, Y., Selmer, T., Keusgen, M., and Schöning, M.J. (2018). Application of a Portable Multi-Analyte Biosensor for Organic Acid Determination in Silage. Sensors, 18. · DOI
  34. Zhu, 2007, Bienzymatic Glucose Biosensor Based on Co-Immobilization of Peroxidase and Glucose Oxidase on a Carbon Nanotubes Electrode, Biosens. Bioelectron., 23, 528, 10.1016/j.bios.2007.07.002 · doi:10.1016/j.bios.2007.07.002
  35. Jia, 2013, Materials-Based Strategies for Multi-Enzyme Immobilization and Co-Localization, Biotechnol. Bioeng., 111, 209, 10.1002/bit.25136 · DOI · Paper page
  36. Serafin, 2013, Electrochemical Biosensor for Creatinine Based on the Immobilization of Creatininase, Creatinase and Sarcosine Oxidase onto a Ferrocene/Horseradish Peroxidase/Gold Nanoparticles/Multi-Walled Carbon Nanotubes/Teflon Composite Electrode, Electrochim. Acta, 97, 175, 10.1016/j.electacta.2013.03.005 · DOI
  37. Noda, 2010, Bioelectrocatalytic Endpoint Assays Based on Steady-State Diffusion Current at Microelectrode Array, Electrochem. Commun., 12, 839, 10.1016/j.elecom.2010.04.002 · doi:10.1016/j.elecom.2010.04.002
  38. Noda, 2013, Diffusion-Controlled Detection of Glucose with Microelectrodes in Mediated Bioelectrocatalytic Oxidation, Anal. Sci., 29, 279, 10.2116/analsci.29.279 · DOI
  39. Kitazumi, 2014, Characteristics of Fast Mediated Bioelectrocatalytic Reaction near Microelectrodes, Phys. Chem. Chem. Phys., 16, 8905, 10.1039/C4CP00141A · doi:10.1039/c4cp00141a
  40. Xia, 2017, Putrescine Oxidase/Peroxidase-Co-Immobilized and Mediator-Less Mesoporous Microelectrode for Diffusion-Controlled Steady-State Amperometric Detection of Putrescine, J. Electroanal. Chem., 804, 128, 10.1016/j.jelechem.2017.09.056 · DOI
  41. Matsui, 2017, Diffusion-Controlled Mediated Electron Transfer-Type Bioelectrocatalysis Using Ultrathin-Ring and Microband Electrodes as Ultimate Amperometric Glucose Sensors, Anal. Sci., 33, 845, 10.2116/analsci.33.845 · DOI
  42. Matsui, 2018, Simultaneous Detection of Lactate Enantiomers Based on the Diffusion-Controlled Bioelectrocatalysis, Anal. Sci., 34, 1137, 10.2116/analsci.18P202 · DOI
  43. Kawai, 2019, Performance Analysis of an Oxidase/Peroxidase-Based Mediatorless Amperometric Biosensor, J. Electroanal. Chem., 841, 73, 10.1016/j.jelechem.2019.04.012 · doi:10.1016/j.jelechem.2019.04.012
  44. Nieh, 2013, Potentiometric Coulometry Based on Charge Accumulation with a Peroxidase/Osmium Polymer-Immobilized Electrode for Sensitive Determination of Hydrogen Peroxide, Electrochem. Commun., 33, 135, 10.1016/j.elecom.2013.05.007 · doi:10.1016/j.elecom.2013.05.007
  45. Katsube, 2016, Potentiometric Coulometry Using a Liquid-Film-Modified Electrode as a Reversible Surface-Confined System, J. Electroanal. Chem., 780, 114, 10.1016/j.jelechem.2016.09.002 · doi:10.1016/j.jelechem.2016.09.002
  46. Matsumoto, 2002, Theory of Steady-State Catalytic Current of Mediated Bioelectrocatalysis, J. Electroanal. Chem., 535, 37, 10.1016/S0022-0728(02)01159-2 · DOI
  47. Albery, 1990, Inhibited Enzyme Electrodes. Part 1: Theoretical Model, Biosens. Bioelectron., 5, 367, 10.1016/0956-5663(90)80016-7 · doi:10.1016/0956-5663(90)80016-7
  48. Tsujimura, 2004, Kinetic Study of Direct Bioelectrocatalysis of Dioxygen Reduction with Bilirubin Oxidase at Carbon Electrodes, Electrochemistry, 72, 437, 10.5796/electrochemistry.72.437 · doi:10.5796/electrochemistry.72.437
  49. Moser, 1992, Nature of Biological Electron Transfer, Nature, 355, 796, 10.1038/355796a0 · DOI · Paper page
  50. Marcus, 1985, Electron Transfers in Chemistry and Biology, BBA Rev. Bioenerg., 811, 265
  51. Wang, 2008, Electrochemical Glucose Biosensors, Chem. Rev., 108, 814, 10.1021/cr068123a · DOI · Paper page
  52. Chen, 2013, Recent Advances in Electrochemical Glucose Biosensors, RSC Adv., 3, 4473, 10.1039/c2ra22351a · DOI · Paper page
  53. Zhu, 2012, A Critical Review of Glucose Biosensors Based on Carbon Nanomaterials: Carbon Nanotubes and Graphene, Sensors, 12, 5996, 10.3390/s120505996 · DOI · Paper page
  54. Lai, 2016, Polyaniline-Based Glucose Biosensor, J. Electroanal. Chem., 782, 138, 10.1016/j.jelechem.2016.10.033 · DOI · Paper page
  55. Rahman, 2017, Recent Trends in the Development of Electrochemical Glucose Biosensors, Int. J. Biosen. Bioelectron., 3, 210
  56. Gregg, 1990, Cross-Linked Redox Gels Containing Glucose Oxidase for Amperometric Biosensor Applications, Anal. Chem., 62, 258, 10.1021/ac00202a007 · DOI · Paper page
  57. Trifonov, 2019, Enzymatic Self-Wiring in Nanopores and Its Application in Direct Electron Transfer Biofuel Cells, Nanoscale Adv., 1, 347, 10.1039/C8NA00177D · doi:10.1039/c8na00177d
  58. Yamashita, 2013, Direct Electron Transfer Type Disposable Sensor Strip for Glucose Sensing Employing an Engineered FAD Glucose Dehydrogenase, Enzym. Microb. Technol., 52, 123, 10.1016/j.enzmictec.2012.11.002 · DOI
  59. Tsujimura, 2006, Novel FAD-Dependent Glucose Dehydrogenase for a Dioxygen-Insensitive Glucose Biosensor, Biosci. Biotechnol. Biochem., 70, 654, 10.1271/bbb.70.654 · DOI · Paper page
  60. Malinauskas, 2004, Bioelectrochemical Sensor Based on PQQ-Dependent Glucose Dehydrogenase, Sens. Actuators B, 100, 387, 10.1016/j.snb.2004.02.006 · DOI
  61. Flexer, 2011, Efficient Direct Electron Transfer of PQQ-Glucose Dehydrogenase on Carbon Cryogel Electrodes at Neutral pH, Anal. Chem., 83, 5721, 10.1021/ac200981r · DOI
  62. Bollella, 2020, A Microelectronic Sensor Device Powered by a Small Implantable Biofuel Cell, ChemPhysChem, 21, 120, 10.1002/cphc.201900700 · DOI
  63. Mie, 2019, Anodized Gold Surface Enables Mediator-Free and Low-Overpotential Electrochemical Oxidation of NADH: A Facile Method for the Development of an NAD+-Dependent Enzyme Biosensor, Sens. Actuators B, 288, 512, 10.1016/j.snb.2019.03.039 · DOI
  64. Ferri, 2011, Review of Glucose Oxidases and Glucose Dehydrogenases: A Bird’s Eye View of Glucose Sensing Enzymes, J. Diabetes Sci. Technol., 5, 1068, 10.1177/193229681100500507 · DOI · Paper page
  65. Kakehi, 2007, A Novel Wireless Glucose Sensor Employing Direct Electron Transfer Principle Based Enzyme Fuel Cell, Biosens. Bioelectron., 22, 2250, 10.1016/j.bios.2006.11.004 · DOI
  66. Roe, 1949, A Photometric Method for the Determination of Inulin in Plasma and Urine, J. Biol. Chem., 178, 839, 10.1016/S0021-9258(18)56901-5 · DOI · Paper page
  67. Bollella, 2018, Highly Sensitive Membraneless Fructose Biosensor Based on Fructose Dehydrogenase Immobilized onto Aryl Thiol Modified Highly Porous Gold Electrode: Characterization and Application in Food Samples, Anal. Chem., 90, 12131, 10.1021/acs.analchem.8b03093 · doi:10.1021/acs.analchem.8b03093
  68. Adachi, 2019, Bioelectrocatalytic Performance of d-Fructose Dehydrogenase, Bioelectrochemistry, 129, 1, 10.1016/j.bioelechem.2019.04.024 · doi:10.1016/j.bioelechem.2019.04.024
  69. Bollella, 2017, Cellobiose Dehydrogenase: Insights on the Nanostructuration of Electrodes for Improved Development of Biosensors and Biofuel Cells, Appl. Mater. Today, 9, 319, 10.1016/j.apmt.2017.08.009 · DOI
  70. Ito, 2019, Designer Fungus FAD Glucose Dehydrogenase Capable of Direct Electron Transfer, Biosens. Bioelectron., 123, 114, 10.1016/j.bios.2018.07.027 · doi:10.1016/j.bios.2018.07.027
  71. Gorton, 1984, Electrocatalytic Oxidation of Reduced Nicotinamide Coenzymes by Graphite Electrodes Modified with an Adsorbed Phenoxazinium Salt, Meldola Blue, J. Electroanal. Chem., 161, 103, 10.1016/S0022-0728(84)80253-3 · doi:10.1016/s0022-0728(84)80253-3
  72. Avramescu, 2001, Chronoamperometric Determination of d-Lactate Using Screen-Printed Enzyme Electrodes, Anal. Chim. Acta, 433, 81, 10.1016/S0003-2670(00)01386-6 · DOI
  73. Takagi, 1998, Mediated Bioelectrocatalysis Based on NAD-Related Enzymes with Reversible Characteristics, J. Electroanal. Chem., 445, 211, 10.1016/S0022-0728(97)00585-8 · doi:10.1016/s0022-0728(97)00585-8
  74. Antiochia, 2002, Kinetic and Thermodynamic Aspects of NAD-Related Enzyme-Linked Mediated Bioelectrocatalysis, Electroanalysis, 14, 1256, 10.1002/1521-4109(200210)14:18<1256::AID-ELAN1256>3.0.CO;2-N · doi:10.1002/1521-4109(200210)14:18<1256::aid-elan1256>3.0.co;2-n
  75. Nikitina, 2007, Bi-Enzyme Biosensor Based on NAD+- and Glutathione-Dependent Recombinant Formaldehyde Dehydrogenase and Diaphorase for Formaldehyde Assay, Sens. Actuators B, 125, 1, 10.1016/j.snb.2007.01.025 · doi:10.1016/j.snb.2007.01.025
  76. Lobo, 1997, Amperometric Biosensors Based on NAD(P)-Dependent Dehydrogenase Enzymes, Electroanalysis, 9, 191, 10.1002/elan.1140090302 · DOI · Paper page
  77. Siritanaratkul, 2017, Transfer of Photosynthetic NADP+/NADPH Recycling Activity to a Porous Metal Oxide for Highly Specific, Electrochemically-Driven Organic Synthesis, Chem. Sci., 8, 4579, 10.1039/C7SC00850C · DOI
  78. Xu, 1997, Development of a Diamine Biosensor, Talanta, 44, 1625, 10.1016/S0039-9140(97)00067-2 · doi:10.1016/s0039-9140(97)00067-2
  79. Carsol, 1999, Diamine Oxidase and Putrescine Oxidase Immobilized Reactors in Flow Injection Analysis: A Comparison in Substrate Specificity, Talanta, 50, 141, 10.1016/S0039-9140(99)00111-3 · doi:10.1016/s0039-9140(99)00111-3
  80. Nagy, 2002, Development and Study of an Amperometric Biosensor for the in Vitro Measurement of Low Concentration of Putrescine in Blood, J. Biochem. Biophys. Methods, 53, 165, 10.1016/S0165-022X(02)00105-7 · doi:10.1016/s0165-022x(02)00105-7
  81. Gorton, 1992, Amperometric Biosensors Based on an Apparent Direct Electron Transfer between Electrodes and Immobilized Peroxidases. Plenary Lecture, Analyst, 117, 1235, 10.1039/AN9921701235 · doi:10.1039/an9921701235
  82. Matsumoto, 2002, Unusual Response in Mediated Biosensors with an Oxidase/Peroxidase Bienzyme System, Anal. Chem., 74, 3297, 10.1021/ac015684n · doi:10.1021/ac015684n
  83. Gemeiner, 1999, Rapid and Sensitive Galactose Oxidase-Peroxidase Biosensor for Galactose Detection with Prolonged Stability, Biotechnol. Tech., 13, 931, 10.1023/A:1008966413722 · DOI
  84. Nieh, 2013, Sensitive d-Amino Acid Biosensor Based on Oxidase/Peroxidase System Mediated by Pentacyanoferrate-Bound Polymer, Biosens. Bioelectron., 47, 350, 10.1016/j.bios.2013.03.042 · DOI
  85. Kacaniklic, 1994, Amperometric Biosensors for Detection of l- and d-Amino Acids Based on Coimmobilized Peroxidase and l- and d-Amino Acid Oxidases in Carbon Paste Electrodes, Electroanalysis, 6, 381, 10.1002/elan.1140060505 · doi:10.1002/elan.1140060505
  86. Yoshida, 1995, Glutamate Sensors Carrying Glutamate Oxidase/Peroxidase Bienzyme System on Tin Oxide Electrode, Anal. Sci., 11, 251, 10.2116/analsci.11.251 · doi:10.2116/analsci.11.251
  87. Castillo, 2003, Bienzyme Biosensors for Glucose, Ethanol and Putrescine Built on Oxidase and Sweet Potato Peroxidase, Biosens. Bioelectron., 18, 705, 10.1016/S0956-5663(03)00011-3 · DOI
  88. Vijayakumar, 1996, Alcohol Biosensors Based on Coupled Oxidase-Peroxidase Systems, Anal. Chim. Acta, 327, 223, 10.1016/0003-2670(96)00093-1 · DOI
  89. Hasunuma, 2004, Real-Time Quantification of Methanol in Plants Using a Hybrid Alcohol Oxidase−Peroxidase Biosensor, Anal. Chem., 76, 1500, 10.1021/ac035309q · DOI
  90. Johansson, 1993, A Reagentless Amperometric Biosensor for Alcohol Detection in Column Liquid Chromatography Based on Co-Immobilized Peroxidase and Alcohol Oxidase in Carbon Paste, J. Biotechnol., 31, 301, 10.1016/0168-1656(93)90076-Y · doi:10.1016/0168-1656(93)90076-y
  91. Smutok, 2006, A Reagentless Bienzyme Amperometric Biosensor Based on Alcohol Oxidase/Peroxidase and an Os-Complex Modified Electrodeposition Paint, Sens. Actuators B, 113, 590, 10.1016/j.snb.2005.07.055 · doi:10.1016/j.snb.2005.07.055
  92. Akyilmaz, 2003, A Biosensor Based on Urate Oxidase–Peroxidase Coupled Enzyme System for Uric Acid Determination in Urine, Talanta, 61, 73, 10.1016/S0039-9140(03)00239-X · doi:10.1016/s0039-9140(03)00239-x
  93. Dharmapandian, 2010, Electrochemical Cysteine Biosensor Based on the Selective Oxidase–Peroxidase Activities of Copper, Zinc Superoxide Dismutase, Sens. Actuators B, 148, 17, 10.1016/j.snb.2010.04.023 · DOI
  94. Gemeiner, 2000, Novel Glucose Non-Interference Biosensor for Lactose Detection Based on Galactose Oxidase–Peroxidase with and without Co-Immobilised β-Galactosidase, Analyst, 125, 1285, 10.1039/b001432j · doi:10.1039/b001432j
  95. Crumbliss, 1993, A Carrageenan Hydrogel Stabilized Colloidal Gold Multi-Enzyme Biosensor Electrode Utilizing Immobilized Horseradish Peroxidase and Cholesterol Oxidase/Cholesterol Esterase to Detect Cholesterol in Serum and Whole Blood, Biosens. Bioelectron., 8, 331, 10.1016/0956-5663(93)85014-F · doi:10.1016/0956-5663(93)85014-f
  96. Li, 2005, Study of Carbon Nanotube Modified Biosensor for Monitoring Total Cholesterol in Blood, Biosens. Bioelectron., 20, 2140, 10.1016/j.bios.2004.09.005 · doi:10.1016/j.bios.2004.09.005
  97. Singh, 2006, Cholesterol Biosensor Based on Cholesterol Esterase, Cholesterol Oxidase and Peroxidase Immobilized onto Conducting Polyaniline Films, Sens. Actuators B, 115, 534, 10.1016/j.snb.2005.10.025 · DOI · Paper page
  98. Nieh, 2013, Amperometric Biosensor Based on Reductive H2O2 Detection Using Pentacyanoferrate-Bound Polymer for Creatinine Determination, Anal. Chim. Acta, 767, 128, 10.1016/j.aca.2012.12.052 · doi:10.1016/j.aca.2012.12.052
  99. Xia, 2017, Direct Electron Transfer-Type Bioelectrocatalysis of Peroxidase at Mesoporous Carbon Electrodes and Its Application for Glucose Determination Based on Bienzyme System, Anal. Sci., 33, 839, 10.2116/analsci.33.839 · doi:10.2116/analsci.33.839
  100. Sakai, 2018, Nanostructured Porous Electrodes by the Anodization of Gold for an Application as Scaffolds in Direct-Electron-Transfer-Type Bioelectrocatalysis, Anal. Sci., 34, 1317, 10.2116/analsci.18P302 · doi:10.2116/analsci.18p302
  101. Sadik, 2009, Status of Biomolecular Recognition Using Electrochemical Techniques, Biosens. Bioelectron., 24, 2749, 10.1016/j.bios.2008.10.003 · DOI · Paper page
  102. Poon, 2015, Big Data for Health, IEEE J. Biomed. Health, 19, 1193, 10.1109/JBHI.2015.2450362 · DOI · Paper page
  103. Tu, 2020, The Era of Digital Health; A Review of Portable and Wearable Affinity Biosensors, Adv. Funct. Mater., 30, 1906713, 10.1002/adfm.201906713 · DOI · Paper page
  104. March, 2015, Modified Electrodes Used for Electrochemical Detection of Metal Ions in Environmental Analysis, Biosensors, 5, 241, 10.3390/bios5020241 · doi:10.3390/bios5020241
  105. Wang, 2010, Digital Biosensors with Built-In Logic for Biomedical Applications–Biosensors Based on a Biocomputing Concept, Anal. Bioanal. Chem., 398, 1591, 10.1007/s00216-010-3746-0 · DOI · Paper page
  106. Guz, 2014, A Biocatalytic Cascade with Several Output Signals–Towards Biosensors with Different Levels of Confidence, Anal. Bioanal. Chem., 406, 3365, 10.1007/s00216-014-7789-5 · doi:10.1007/s00216-014-7789-5
  107. Katz, 2017, Enzyme-Based Logic Gates and Circuits–Analytical Applications and Interfacing with Electronics, Anal. Bioanal. Chem., 409, 81, 10.1007/s00216-016-0079-7 · DOI
  108. Bard, A.J., and Faulkner, L.R. (2001). Electrochemical Methods: Fundamentals and Applications, Wiley. [2nd ed.].
  109. Waikar, 2010, Normalization of Urinary Biomarkers to Creatinine during Changes in Glomerular Filtration Rate, Kidney Int., 78, 486, 10.1038/ki.2010.165 · DOI · Paper page
  110. Ganguly, 2020, A Combinatorial Electrochemical Biosensor for Sweat Biomarker Benchmarking, SLAS Technol., 25, 25, 10.1177/2472630319882003 · DOI
  111. Appenzeller, 2007, Determination of the Volume of Sweat Accumulated in a Sweat-Patch Using Sodium and Potassium as Internal Reference, J. Chromatogr. B, 852, 333, 10.1016/j.jchromb.2007.01.037 · DOI
  112. Smith, 1986, Use of d-Lactic Acid Measurements in the Diagnosis of Bacterial Infections, J. Infect. Dis., 154, 658, 10.1093/infdis/154.4.658 · DOI
  113. Shoup, 1982, Chronoamperometric Current at Finite Disk Electrodes, J. Electroanal. Chem., 140, 237, 10.1016/0022-0728(82)85171-1 · DOI · Paper page
  114. Miyata, 2020, Diffusion-Limited Biosensing of Dissolved Oxygen by Direct Electron Transfer-Type Bioelectrocatalysis of Multi-Copper Oxidases Immobilized on Porous Gold Microelectrodes, J. Electroanal. Chem., 860, 113895, 10.1016/j.jelechem.2020.113895 · DOI
  115. Sugimoto, 2016, Significance of Mesoporous Electrodes for Noncatalytic Faradaic Process of Randomly Oriented Redox Proteins, J. Phys. Chem. C, 120, 26270, 10.1021/acs.jpcc.6b07413 · DOI
  116. Sugimoto, 2017, Effects of Mesoporous Structures on Direct Electron Transfer-Type Bioelectrocatalysis: Facts and Simulation on a Three-Dimensional Model of Random Orientation of Enzymes, Electrochemistry, 85, 82, 10.5796/electrochemistry.85.82 · DOI
  117. Lee, 2001, Cyclic Voltammetry at a Regular Microdisc Electrode Array, J. Electroanal. Chem., 502, 138, 10.1016/S0022-0728(01)00343-6 · doi:10.1016/s0022-0728(01)00343-6
  118. Ordeig, 2007, Electroanalysis Utilizing Amperometric Microdisk Electrode Arrays, Electroanalysis, 19, 1973, 10.1002/elan.200703914 · DOI
  119. Guo, 2009, Cyclic Voltammograms at Coplanar and Shallow Recessed Microdisk ElectrodeAarrays: Guidelines for Design and Experiment, Anal. Chem., 81, 130, 10.1021/ac801592j · doi:10.1021/ac801592j
  120. Bixler, 1989, An Evaluation of Ultrathin Ring and Band Microelectrodes as Amperometric Sensors in Electrochemical Flow Cells, Electroanalysis, 1, 23, 10.1002/elan.1140010105 · doi:10.1002/elan.1140010105
  121. Kitazumi, 2015, Fabrication and Characterization of Ultrathin-Ring Electrodes for Pseudo-Steady-State Amperometric Detection, Anal. Sci., 31, 603, 10.2116/analsci.31.603 · doi:10.2116/analsci.31.603
  122. Szabo, 1987, Chronoamperometric Current at Hemicylinder and Band Microelectrodes: Theory and Experiment, J. Electroanal. Chem., 217, 417, 10.1016/0022-0728(87)80233-4 · doi:10.1016/0022-0728(87)80233-4
  123. Uchiyama, 1991, Biocoulometry of Cholesterol Using Porous Carbon Felt Electrodes, Electroanalysis, 3, 59, 10.1002/elan.1140030111 · doi:10.1002/elan.1140030111
  124. Morris, 1992, An Electrochemical Capillary Fill Device for the Analysis of Glucose Incorporating Glucose Oxidase and Ruthenium (III) Hexamine as Mediator, Electroanalysis, 4, 1, 10.1002/elan.1140040104 · doi:10.1002/elan.1140040104
  125. Fukaya, 1995, Self-Driven Coulometry of Ethanol, d-Glucose and d-Fructose Using Ubiquinone-Dependent Dehydrogenase Reactions, Anal. Chim. Acta, 306, 231, 10.1016/0003-2670(95)00012-O · doi:10.1016/0003-2670(95)00012-o
  126. Tsujimura, 2009, Coulometric d-Fructose Biosensor Based on Direct Electron Transfer Using d-Fructose Dehydrogenase, Anal. Chem., 81, 9383, 10.1021/ac901771t · DOI
  127. Mizutani, 2008, Highly-Sensitive Biosensors with Chemically-Amplified Responses, Electrochemistry, 76, 515, 10.5796/electrochemistry.76.515 · doi:10.5796/electrochemistry.76.515

Metadata

Authors
Adachi, T., Kitazumi, Y., Shirai, O., & Kano, K.
Venue
Sensors
Publisher
MDPI AG
Published
2020-08-26
Volume
20
Issue
17
Pages
4826
ISSN
1424-8220
Cited by
35
References
4
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development Perspective of Bioelectrocatalysis-Based Biosensors. https://app.cochat.ai/papers/10.3390/s20174826
The paper
Adachi, T., Kitazumi, Y., Shirai, O., & Kano, K. (2020). Development Perspective of Bioelectrocatalysis-Based Biosensors. Sensors. https://doi.org/10.3390/s20174826

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.