Abstract
Bioelectrocatalysis provides the intrinsic catalytic functions of redox enzymes to nonspecific electrode reactions and is the most important and basic concept for electrochemical biosensors. This review starts by describing fundamental characteristics of bioelectrocatalytic reactions in mediated and direct electron transfer types from a theoretical viewpoint and summarizes amperometric biosensors based on multi-enzymatic cascades and for multianalyte detection. The review also introduces prospective aspects of two new concepts of biosensors: mass-transfer-controlled (pseudo)steady-state amperometry at microelectrodes with enhanced enzymatic activity without calibration curves and potentiometric coulometry at enzyme/mediator-immobilized biosensors for absolute determination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electron transfer reactions in chemistry. Theory and experiment
Marcus, R. A. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.599 · Cited by 3,667
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
In-Vivo Electrochemistry: What Can We Learn about Living Systems?
Wilson, G. S., & Johnson, M. A. (2008) · Chemical Reviews · doi:10.1021/cr068082i · Cited by 178
Research works printed but not linked: 127
- Bartlett, P.N. (2008). Bioelectrochemistry: Fundamentals, Experimental Techniques and Applications, John Wiley & Sons. · DOI
- Heller, 1992, Electrical Connection of Enzyme Redox Centers to Electrodes, J. Phys. Chem., 96, 3579, 10.1021/j100188a007 · DOI · Paper page
- Durst, 1999, Electrochemical Biosensors: Recommended Definitions and Classification, Pure Appl. Chem., 71, 2333, 10.1351/pac199971122333 · DOI · Paper page
- Armstrong, 2011, Reversibility and Efficiency in Electrocatalytic Energy Conversion and Lessons from Enzymes, Proc. Natl. Acad. Sci. USA, 108, 14049, 10.1073/pnas.1103697108 · DOI · Paper page
- Ranava, 2014, Biohydrogen for a New Generation of H2/O2 Biofuel Cells: A Sustainable Energy Perspective, ChemElectroChem, 1, 1724, 10.1002/celc.201402249 · DOI
- Fourmond, 2017, Modelling the Voltammetry of Adsorbed Enzymes and Molecular Catalysts, Curr. Opin. Electrochem., 1, 110, 10.1016/j.coelec.2016.11.002 · DOI
- Martinkova, 2017, Main Streams in the Construction of Biosensors and Their Applications, Int. J. Electrochem. Sci., 12, 7386, 10.20964/2017.08.02 · doi:10.20964/2017.08.02
- Bollella, 2018, Enzyme Based Amperometric Biosensors, Curr. Opin. Electrochim., 10, 157, 10.1016/j.coelec.2018.06.003 · DOI · Paper page
- Kano, 2019, Fundamentals and Applications of Redox Enzyme-Functionalized Electrode Reactions, Electrochemistry, 87, 301, 10.5796/electrochemistry.19-6-E2676 · doi:10.5796/electrochemistry.19-6-e2676
- Kucherenko, 2019, Advances in Nanomaterial Application in Enzyme-Based Electrochemical Biosensors, Nanoscale Adv., 1, 4560, 10.1039/C9NA00491B · DOI · Paper page
- Ngyen, H.H., Lee, S.H., Lee, U.J., Fermin, C.D., and Kim, M. (2019). Immobilized Enzymes in Biosensor Applications. Materials, 12. · DOI · Paper page
- Pinyou, 2019, Enzyme-Modified Electrodes for Biosensors and Biofuel Cells, Mater. Horiz., 6, 1336, 10.1039/C9MH00013E · DOI
- Bollella, P., and Katz, E. (2020). Enzyme-Based Biosensors: Tackling Electron Transfer Issues. Sensors, 20. · DOI · Paper page
- Willner, 1997, Electrical Contact of Redox Enzyme Layers Associated with Electrodes; Routes to Amperometric Biosensors, Electroanalysis, 9, 965, 10.1002/elan.1140091302 · DOI · Paper page
- Barton, 2004, Enzymatic Biofuel Cells for Implantable and Microscale Devices, Chem. Rev., 104, 4867, 10.1021/cr020719k · DOI · Paper page
- Cracknell, 2008, Enzymes as Working or Inspirational Electrocatalysts for Fuel Cells and Electrolysis, Chem. Rev., 108, 2439, 10.1021/cr0680639 · DOI · Paper page
- Meredith, 2012, Biofuel Cells; Enhanced Enzymatic Bioelectrocatalysis, Annu. Rev. Anal. Chem., 5, 157, 10.1146/annurev-anchem-062011-143049 · DOI · Paper page
- Mazurenko, 2017, Recent Developments in High Surface Area Bioelectrodes for Enzymatic Fuel Cells, Curr. Opin. Electrochem., 5, 74, 10.1016/j.coelec.2017.07.001 · DOI
- Mano, 2018, O2 Reduction in Enzymatic Biofuel Cells, Chem. Rev., 118, 2392, 10.1021/acs.chemrev.7b00220 · DOI · Paper page
- Krieg, 2014, Reactor Concepts for Bioelectrochemical Syntheses and Energy Conversion, Trends Biotechnol., 32, 645, 10.1016/j.tibtech.2014.10.004 · doi:10.1016/j.tibtech.2014.10.004
- Milton, 2017, Enzymatic Bioelectrosynthetic Ammonia Production: Recent Electrochemistry of Nitrogenase, Nitrate Reductase, and Nitrite Reductase, ChemPlusChem, 82, 513, 10.1002/cplu.201600442 · DOI
- Shleev, 2017, Biosupercapacitors, Curr. Opin. Electrochem., 5, 226, 10.1016/j.coelec.2017.09.023 · DOI
- Dutton, 1978, Redox Potentiometry: Determination of Midpoint Potentials of Oxidation-Reduction Components of Biological Electron-Transfer Systems, Methods Enzymol., 54, 411, 10.1016/S0076-6879(78)54026-3 · DOI · Paper page
- Scheller, 1987, Enzyme Electrodes and Their Application, Phil. Trans. R. Lond. B, 316, 85, 10.1098/rstb.1987.0019 · DOI
- Scheller, 1989, Research and Development of Biosensors, Analyst, 114, 653, 10.1039/AN9891400653 · doi:10.1039/an9891400653
- Pessoa, 2003, Direct Electron Transfer: An Approarch for Electrochemical Biosensors with Higher Selectivity and Sensitivity, J. Braz. Chem. Soc., 14, 230, 10.1590/S0103-50532003000200008 · DOI · Paper page
- Bertrand, 2008, Direct Electrochemistry of Redox Enzymes as Tool for Mechanistic Studies, Chem. Rev., 108, 2379, 10.1021/cr0680742 · DOI · Paper page
- Milton, 2017, Direct Enzymatic Bioelectrocatalysis: Differentiating between Myth and Reality, J. R. Soc. Interface, 14, 20170253, 10.1098/rsif.2017.0253 · DOI · Paper page
- Adachi, T., Kitazumi, Y., Shirai, O., and Kano, K. (2020). Direct Electron Transfer-Type Bioelectrocatalysis of Redox Enzymes at Nanostructured Electrodes. Catalysts, 10. · doi:10.20944/preprints202002.0031.v1
- Kitazumi, Y., Shirai, O., and Kano, K. (2020). Significance of Nanostructures of an Electrode Surface in Direct Electron Transfer-Type Bioelectrocatalysis of Redox Enzymes, in Novel Catalyst Materials for Bioelectrochemical Systems: Fundamentals and Applications, ACS Publications. · doi:10.1021/bk-2020-1342.ch007
- Hooda, 2018, Recent Trends and Perspectives in Enzyme Based Biosensor Development for the Screening of Triglycerides: A Comprehensive Review, Artif. Cells Nanomed. Biotechnol., 46, 626, 10.1080/21691401.2018.1465946 · DOI
- Semenova, 2020, Towards One-Step Design of Tailored Enzymatic Nanobiosensors, Analyst, 145, 1014, 10.1039/C9AN01745C · DOI
- Pilas, J., Yazici, Y., Selmer, T., Keusgen, M., and Schöning, M.J. (2018). Application of a Portable Multi-Analyte Biosensor for Organic Acid Determination in Silage. Sensors, 18. · DOI
- Zhu, 2007, Bienzymatic Glucose Biosensor Based on Co-Immobilization of Peroxidase and Glucose Oxidase on a Carbon Nanotubes Electrode, Biosens. Bioelectron., 23, 528, 10.1016/j.bios.2007.07.002 · doi:10.1016/j.bios.2007.07.002
- Jia, 2013, Materials-Based Strategies for Multi-Enzyme Immobilization and Co-Localization, Biotechnol. Bioeng., 111, 209, 10.1002/bit.25136 · DOI · Paper page
- Serafin, 2013, Electrochemical Biosensor for Creatinine Based on the Immobilization of Creatininase, Creatinase and Sarcosine Oxidase onto a Ferrocene/Horseradish Peroxidase/Gold Nanoparticles/Multi-Walled Carbon Nanotubes/Teflon Composite Electrode, Electrochim. Acta, 97, 175, 10.1016/j.electacta.2013.03.005 · DOI
- Noda, 2010, Bioelectrocatalytic Endpoint Assays Based on Steady-State Diffusion Current at Microelectrode Array, Electrochem. Commun., 12, 839, 10.1016/j.elecom.2010.04.002 · doi:10.1016/j.elecom.2010.04.002
- Noda, 2013, Diffusion-Controlled Detection of Glucose with Microelectrodes in Mediated Bioelectrocatalytic Oxidation, Anal. Sci., 29, 279, 10.2116/analsci.29.279 · DOI
- Kitazumi, 2014, Characteristics of Fast Mediated Bioelectrocatalytic Reaction near Microelectrodes, Phys. Chem. Chem. Phys., 16, 8905, 10.1039/C4CP00141A · doi:10.1039/c4cp00141a
- Xia, 2017, Putrescine Oxidase/Peroxidase-Co-Immobilized and Mediator-Less Mesoporous Microelectrode for Diffusion-Controlled Steady-State Amperometric Detection of Putrescine, J. Electroanal. Chem., 804, 128, 10.1016/j.jelechem.2017.09.056 · DOI
- Matsui, 2017, Diffusion-Controlled Mediated Electron Transfer-Type Bioelectrocatalysis Using Ultrathin-Ring and Microband Electrodes as Ultimate Amperometric Glucose Sensors, Anal. Sci., 33, 845, 10.2116/analsci.33.845 · DOI
- Matsui, 2018, Simultaneous Detection of Lactate Enantiomers Based on the Diffusion-Controlled Bioelectrocatalysis, Anal. Sci., 34, 1137, 10.2116/analsci.18P202 · DOI
- Kawai, 2019, Performance Analysis of an Oxidase/Peroxidase-Based Mediatorless Amperometric Biosensor, J. Electroanal. Chem., 841, 73, 10.1016/j.jelechem.2019.04.012 · doi:10.1016/j.jelechem.2019.04.012
- Nieh, 2013, Potentiometric Coulometry Based on Charge Accumulation with a Peroxidase/Osmium Polymer-Immobilized Electrode for Sensitive Determination of Hydrogen Peroxide, Electrochem. Commun., 33, 135, 10.1016/j.elecom.2013.05.007 · doi:10.1016/j.elecom.2013.05.007
- Katsube, 2016, Potentiometric Coulometry Using a Liquid-Film-Modified Electrode as a Reversible Surface-Confined System, J. Electroanal. Chem., 780, 114, 10.1016/j.jelechem.2016.09.002 · doi:10.1016/j.jelechem.2016.09.002
- Matsumoto, 2002, Theory of Steady-State Catalytic Current of Mediated Bioelectrocatalysis, J. Electroanal. Chem., 535, 37, 10.1016/S0022-0728(02)01159-2 · DOI
- Albery, 1990, Inhibited Enzyme Electrodes. Part 1: Theoretical Model, Biosens. Bioelectron., 5, 367, 10.1016/0956-5663(90)80016-7 · doi:10.1016/0956-5663(90)80016-7
- Tsujimura, 2004, Kinetic Study of Direct Bioelectrocatalysis of Dioxygen Reduction with Bilirubin Oxidase at Carbon Electrodes, Electrochemistry, 72, 437, 10.5796/electrochemistry.72.437 · doi:10.5796/electrochemistry.72.437
- Moser, 1992, Nature of Biological Electron Transfer, Nature, 355, 796, 10.1038/355796a0 · DOI · Paper page
- Marcus, 1985, Electron Transfers in Chemistry and Biology, BBA Rev. Bioenerg., 811, 265
- Wang, 2008, Electrochemical Glucose Biosensors, Chem. Rev., 108, 814, 10.1021/cr068123a · DOI · Paper page
- Chen, 2013, Recent Advances in Electrochemical Glucose Biosensors, RSC Adv., 3, 4473, 10.1039/c2ra22351a · DOI · Paper page
- Zhu, 2012, A Critical Review of Glucose Biosensors Based on Carbon Nanomaterials: Carbon Nanotubes and Graphene, Sensors, 12, 5996, 10.3390/s120505996 · DOI · Paper page
- Lai, 2016, Polyaniline-Based Glucose Biosensor, J. Electroanal. Chem., 782, 138, 10.1016/j.jelechem.2016.10.033 · DOI · Paper page
- Rahman, 2017, Recent Trends in the Development of Electrochemical Glucose Biosensors, Int. J. Biosen. Bioelectron., 3, 210
- Gregg, 1990, Cross-Linked Redox Gels Containing Glucose Oxidase for Amperometric Biosensor Applications, Anal. Chem., 62, 258, 10.1021/ac00202a007 · DOI · Paper page
- Trifonov, 2019, Enzymatic Self-Wiring in Nanopores and Its Application in Direct Electron Transfer Biofuel Cells, Nanoscale Adv., 1, 347, 10.1039/C8NA00177D · doi:10.1039/c8na00177d
- Yamashita, 2013, Direct Electron Transfer Type Disposable Sensor Strip for Glucose Sensing Employing an Engineered FAD Glucose Dehydrogenase, Enzym. Microb. Technol., 52, 123, 10.1016/j.enzmictec.2012.11.002 · DOI
- Tsujimura, 2006, Novel FAD-Dependent Glucose Dehydrogenase for a Dioxygen-Insensitive Glucose Biosensor, Biosci. Biotechnol. Biochem., 70, 654, 10.1271/bbb.70.654 · DOI · Paper page
- Malinauskas, 2004, Bioelectrochemical Sensor Based on PQQ-Dependent Glucose Dehydrogenase, Sens. Actuators B, 100, 387, 10.1016/j.snb.2004.02.006 · DOI
- Flexer, 2011, Efficient Direct Electron Transfer of PQQ-Glucose Dehydrogenase on Carbon Cryogel Electrodes at Neutral pH, Anal. Chem., 83, 5721, 10.1021/ac200981r · DOI
- Bollella, 2020, A Microelectronic Sensor Device Powered by a Small Implantable Biofuel Cell, ChemPhysChem, 21, 120, 10.1002/cphc.201900700 · DOI
- Mie, 2019, Anodized Gold Surface Enables Mediator-Free and Low-Overpotential Electrochemical Oxidation of NADH: A Facile Method for the Development of an NAD+-Dependent Enzyme Biosensor, Sens. Actuators B, 288, 512, 10.1016/j.snb.2019.03.039 · DOI
- Ferri, 2011, Review of Glucose Oxidases and Glucose Dehydrogenases: A Bird’s Eye View of Glucose Sensing Enzymes, J. Diabetes Sci. Technol., 5, 1068, 10.1177/193229681100500507 · DOI · Paper page
- Kakehi, 2007, A Novel Wireless Glucose Sensor Employing Direct Electron Transfer Principle Based Enzyme Fuel Cell, Biosens. Bioelectron., 22, 2250, 10.1016/j.bios.2006.11.004 · DOI
- Roe, 1949, A Photometric Method for the Determination of Inulin in Plasma and Urine, J. Biol. Chem., 178, 839, 10.1016/S0021-9258(18)56901-5 · DOI · Paper page
- Bollella, 2018, Highly Sensitive Membraneless Fructose Biosensor Based on Fructose Dehydrogenase Immobilized onto Aryl Thiol Modified Highly Porous Gold Electrode: Characterization and Application in Food Samples, Anal. Chem., 90, 12131, 10.1021/acs.analchem.8b03093 · doi:10.1021/acs.analchem.8b03093
- Adachi, 2019, Bioelectrocatalytic Performance of d-Fructose Dehydrogenase, Bioelectrochemistry, 129, 1, 10.1016/j.bioelechem.2019.04.024 · doi:10.1016/j.bioelechem.2019.04.024
- Bollella, 2017, Cellobiose Dehydrogenase: Insights on the Nanostructuration of Electrodes for Improved Development of Biosensors and Biofuel Cells, Appl. Mater. Today, 9, 319, 10.1016/j.apmt.2017.08.009 · DOI
- Ito, 2019, Designer Fungus FAD Glucose Dehydrogenase Capable of Direct Electron Transfer, Biosens. Bioelectron., 123, 114, 10.1016/j.bios.2018.07.027 · doi:10.1016/j.bios.2018.07.027
- Gorton, 1984, Electrocatalytic Oxidation of Reduced Nicotinamide Coenzymes by Graphite Electrodes Modified with an Adsorbed Phenoxazinium Salt, Meldola Blue, J. Electroanal. Chem., 161, 103, 10.1016/S0022-0728(84)80253-3 · doi:10.1016/s0022-0728(84)80253-3
- Avramescu, 2001, Chronoamperometric Determination of d-Lactate Using Screen-Printed Enzyme Electrodes, Anal. Chim. Acta, 433, 81, 10.1016/S0003-2670(00)01386-6 · DOI
- Takagi, 1998, Mediated Bioelectrocatalysis Based on NAD-Related Enzymes with Reversible Characteristics, J. Electroanal. Chem., 445, 211, 10.1016/S0022-0728(97)00585-8 · doi:10.1016/s0022-0728(97)00585-8
- Antiochia, 2002, Kinetic and Thermodynamic Aspects of NAD-Related Enzyme-Linked Mediated Bioelectrocatalysis, Electroanalysis, 14, 1256, 10.1002/1521-4109(200210)14:18<1256::AID-ELAN1256>3.0.CO;2-N · doi:10.1002/1521-4109(200210)14:18<1256::aid-elan1256>3.0.co;2-n
- Nikitina, 2007, Bi-Enzyme Biosensor Based on NAD+- and Glutathione-Dependent Recombinant Formaldehyde Dehydrogenase and Diaphorase for Formaldehyde Assay, Sens. Actuators B, 125, 1, 10.1016/j.snb.2007.01.025 · doi:10.1016/j.snb.2007.01.025
- Lobo, 1997, Amperometric Biosensors Based on NAD(P)-Dependent Dehydrogenase Enzymes, Electroanalysis, 9, 191, 10.1002/elan.1140090302 · DOI · Paper page
- Siritanaratkul, 2017, Transfer of Photosynthetic NADP+/NADPH Recycling Activity to a Porous Metal Oxide for Highly Specific, Electrochemically-Driven Organic Synthesis, Chem. Sci., 8, 4579, 10.1039/C7SC00850C · DOI
- Xu, 1997, Development of a Diamine Biosensor, Talanta, 44, 1625, 10.1016/S0039-9140(97)00067-2 · doi:10.1016/s0039-9140(97)00067-2
- Carsol, 1999, Diamine Oxidase and Putrescine Oxidase Immobilized Reactors in Flow Injection Analysis: A Comparison in Substrate Specificity, Talanta, 50, 141, 10.1016/S0039-9140(99)00111-3 · doi:10.1016/s0039-9140(99)00111-3
- Nagy, 2002, Development and Study of an Amperometric Biosensor for the in Vitro Measurement of Low Concentration of Putrescine in Blood, J. Biochem. Biophys. Methods, 53, 165, 10.1016/S0165-022X(02)00105-7 · doi:10.1016/s0165-022x(02)00105-7
- Gorton, 1992, Amperometric Biosensors Based on an Apparent Direct Electron Transfer between Electrodes and Immobilized Peroxidases. Plenary Lecture, Analyst, 117, 1235, 10.1039/AN9921701235 · doi:10.1039/an9921701235
- Matsumoto, 2002, Unusual Response in Mediated Biosensors with an Oxidase/Peroxidase Bienzyme System, Anal. Chem., 74, 3297, 10.1021/ac015684n · doi:10.1021/ac015684n
- Gemeiner, 1999, Rapid and Sensitive Galactose Oxidase-Peroxidase Biosensor for Galactose Detection with Prolonged Stability, Biotechnol. Tech., 13, 931, 10.1023/A:1008966413722 · DOI
- Nieh, 2013, Sensitive d-Amino Acid Biosensor Based on Oxidase/Peroxidase System Mediated by Pentacyanoferrate-Bound Polymer, Biosens. Bioelectron., 47, 350, 10.1016/j.bios.2013.03.042 · DOI
- Kacaniklic, 1994, Amperometric Biosensors for Detection of l- and d-Amino Acids Based on Coimmobilized Peroxidase and l- and d-Amino Acid Oxidases in Carbon Paste Electrodes, Electroanalysis, 6, 381, 10.1002/elan.1140060505 · doi:10.1002/elan.1140060505
- Yoshida, 1995, Glutamate Sensors Carrying Glutamate Oxidase/Peroxidase Bienzyme System on Tin Oxide Electrode, Anal. Sci., 11, 251, 10.2116/analsci.11.251 · doi:10.2116/analsci.11.251
- Castillo, 2003, Bienzyme Biosensors for Glucose, Ethanol and Putrescine Built on Oxidase and Sweet Potato Peroxidase, Biosens. Bioelectron., 18, 705, 10.1016/S0956-5663(03)00011-3 · DOI
- Vijayakumar, 1996, Alcohol Biosensors Based on Coupled Oxidase-Peroxidase Systems, Anal. Chim. Acta, 327, 223, 10.1016/0003-2670(96)00093-1 · DOI
- Hasunuma, 2004, Real-Time Quantification of Methanol in Plants Using a Hybrid Alcohol Oxidase−Peroxidase Biosensor, Anal. Chem., 76, 1500, 10.1021/ac035309q · DOI
- Johansson, 1993, A Reagentless Amperometric Biosensor for Alcohol Detection in Column Liquid Chromatography Based on Co-Immobilized Peroxidase and Alcohol Oxidase in Carbon Paste, J. Biotechnol., 31, 301, 10.1016/0168-1656(93)90076-Y · doi:10.1016/0168-1656(93)90076-y
- Smutok, 2006, A Reagentless Bienzyme Amperometric Biosensor Based on Alcohol Oxidase/Peroxidase and an Os-Complex Modified Electrodeposition Paint, Sens. Actuators B, 113, 590, 10.1016/j.snb.2005.07.055 · doi:10.1016/j.snb.2005.07.055
- Akyilmaz, 2003, A Biosensor Based on Urate Oxidase–Peroxidase Coupled Enzyme System for Uric Acid Determination in Urine, Talanta, 61, 73, 10.1016/S0039-9140(03)00239-X · doi:10.1016/s0039-9140(03)00239-x
- Dharmapandian, 2010, Electrochemical Cysteine Biosensor Based on the Selective Oxidase–Peroxidase Activities of Copper, Zinc Superoxide Dismutase, Sens. Actuators B, 148, 17, 10.1016/j.snb.2010.04.023 · DOI
- Gemeiner, 2000, Novel Glucose Non-Interference Biosensor for Lactose Detection Based on Galactose Oxidase–Peroxidase with and without Co-Immobilised β-Galactosidase, Analyst, 125, 1285, 10.1039/b001432j · doi:10.1039/b001432j
- Crumbliss, 1993, A Carrageenan Hydrogel Stabilized Colloidal Gold Multi-Enzyme Biosensor Electrode Utilizing Immobilized Horseradish Peroxidase and Cholesterol Oxidase/Cholesterol Esterase to Detect Cholesterol in Serum and Whole Blood, Biosens. Bioelectron., 8, 331, 10.1016/0956-5663(93)85014-F · doi:10.1016/0956-5663(93)85014-f
- Li, 2005, Study of Carbon Nanotube Modified Biosensor for Monitoring Total Cholesterol in Blood, Biosens. Bioelectron., 20, 2140, 10.1016/j.bios.2004.09.005 · doi:10.1016/j.bios.2004.09.005
- Singh, 2006, Cholesterol Biosensor Based on Cholesterol Esterase, Cholesterol Oxidase and Peroxidase Immobilized onto Conducting Polyaniline Films, Sens. Actuators B, 115, 534, 10.1016/j.snb.2005.10.025 · DOI · Paper page
- Nieh, 2013, Amperometric Biosensor Based on Reductive H2O2 Detection Using Pentacyanoferrate-Bound Polymer for Creatinine Determination, Anal. Chim. Acta, 767, 128, 10.1016/j.aca.2012.12.052 · doi:10.1016/j.aca.2012.12.052
- Xia, 2017, Direct Electron Transfer-Type Bioelectrocatalysis of Peroxidase at Mesoporous Carbon Electrodes and Its Application for Glucose Determination Based on Bienzyme System, Anal. Sci., 33, 839, 10.2116/analsci.33.839 · doi:10.2116/analsci.33.839
- Sakai, 2018, Nanostructured Porous Electrodes by the Anodization of Gold for an Application as Scaffolds in Direct-Electron-Transfer-Type Bioelectrocatalysis, Anal. Sci., 34, 1317, 10.2116/analsci.18P302 · doi:10.2116/analsci.18p302
- Sadik, 2009, Status of Biomolecular Recognition Using Electrochemical Techniques, Biosens. Bioelectron., 24, 2749, 10.1016/j.bios.2008.10.003 · DOI · Paper page
- Poon, 2015, Big Data for Health, IEEE J. Biomed. Health, 19, 1193, 10.1109/JBHI.2015.2450362 · DOI · Paper page
- Tu, 2020, The Era of Digital Health; A Review of Portable and Wearable Affinity Biosensors, Adv. Funct. Mater., 30, 1906713, 10.1002/adfm.201906713 · DOI · Paper page
- March, 2015, Modified Electrodes Used for Electrochemical Detection of Metal Ions in Environmental Analysis, Biosensors, 5, 241, 10.3390/bios5020241 · doi:10.3390/bios5020241
- Wang, 2010, Digital Biosensors with Built-In Logic for Biomedical Applications–Biosensors Based on a Biocomputing Concept, Anal. Bioanal. Chem., 398, 1591, 10.1007/s00216-010-3746-0 · DOI · Paper page
- Guz, 2014, A Biocatalytic Cascade with Several Output Signals–Towards Biosensors with Different Levels of Confidence, Anal. Bioanal. Chem., 406, 3365, 10.1007/s00216-014-7789-5 · doi:10.1007/s00216-014-7789-5
- Katz, 2017, Enzyme-Based Logic Gates and Circuits–Analytical Applications and Interfacing with Electronics, Anal. Bioanal. Chem., 409, 81, 10.1007/s00216-016-0079-7 · DOI
- Bard, A.J., and Faulkner, L.R. (2001). Electrochemical Methods: Fundamentals and Applications, Wiley. [2nd ed.].
- Waikar, 2010, Normalization of Urinary Biomarkers to Creatinine during Changes in Glomerular Filtration Rate, Kidney Int., 78, 486, 10.1038/ki.2010.165 · DOI · Paper page
- Ganguly, 2020, A Combinatorial Electrochemical Biosensor for Sweat Biomarker Benchmarking, SLAS Technol., 25, 25, 10.1177/2472630319882003 · DOI
- Appenzeller, 2007, Determination of the Volume of Sweat Accumulated in a Sweat-Patch Using Sodium and Potassium as Internal Reference, J. Chromatogr. B, 852, 333, 10.1016/j.jchromb.2007.01.037 · DOI
- Smith, 1986, Use of d-Lactic Acid Measurements in the Diagnosis of Bacterial Infections, J. Infect. Dis., 154, 658, 10.1093/infdis/154.4.658 · DOI
- Shoup, 1982, Chronoamperometric Current at Finite Disk Electrodes, J. Electroanal. Chem., 140, 237, 10.1016/0022-0728(82)85171-1 · DOI · Paper page
- Miyata, 2020, Diffusion-Limited Biosensing of Dissolved Oxygen by Direct Electron Transfer-Type Bioelectrocatalysis of Multi-Copper Oxidases Immobilized on Porous Gold Microelectrodes, J. Electroanal. Chem., 860, 113895, 10.1016/j.jelechem.2020.113895 · DOI
- Sugimoto, 2016, Significance of Mesoporous Electrodes for Noncatalytic Faradaic Process of Randomly Oriented Redox Proteins, J. Phys. Chem. C, 120, 26270, 10.1021/acs.jpcc.6b07413 · DOI
- Sugimoto, 2017, Effects of Mesoporous Structures on Direct Electron Transfer-Type Bioelectrocatalysis: Facts and Simulation on a Three-Dimensional Model of Random Orientation of Enzymes, Electrochemistry, 85, 82, 10.5796/electrochemistry.85.82 · DOI
- Lee, 2001, Cyclic Voltammetry at a Regular Microdisc Electrode Array, J. Electroanal. Chem., 502, 138, 10.1016/S0022-0728(01)00343-6 · doi:10.1016/s0022-0728(01)00343-6
- Ordeig, 2007, Electroanalysis Utilizing Amperometric Microdisk Electrode Arrays, Electroanalysis, 19, 1973, 10.1002/elan.200703914 · DOI
- Guo, 2009, Cyclic Voltammograms at Coplanar and Shallow Recessed Microdisk ElectrodeAarrays: Guidelines for Design and Experiment, Anal. Chem., 81, 130, 10.1021/ac801592j · doi:10.1021/ac801592j
- Bixler, 1989, An Evaluation of Ultrathin Ring and Band Microelectrodes as Amperometric Sensors in Electrochemical Flow Cells, Electroanalysis, 1, 23, 10.1002/elan.1140010105 · doi:10.1002/elan.1140010105
- Kitazumi, 2015, Fabrication and Characterization of Ultrathin-Ring Electrodes for Pseudo-Steady-State Amperometric Detection, Anal. Sci., 31, 603, 10.2116/analsci.31.603 · doi:10.2116/analsci.31.603
- Szabo, 1987, Chronoamperometric Current at Hemicylinder and Band Microelectrodes: Theory and Experiment, J. Electroanal. Chem., 217, 417, 10.1016/0022-0728(87)80233-4 · doi:10.1016/0022-0728(87)80233-4
- Uchiyama, 1991, Biocoulometry of Cholesterol Using Porous Carbon Felt Electrodes, Electroanalysis, 3, 59, 10.1002/elan.1140030111 · doi:10.1002/elan.1140030111
- Morris, 1992, An Electrochemical Capillary Fill Device for the Analysis of Glucose Incorporating Glucose Oxidase and Ruthenium (III) Hexamine as Mediator, Electroanalysis, 4, 1, 10.1002/elan.1140040104 · doi:10.1002/elan.1140040104
- Fukaya, 1995, Self-Driven Coulometry of Ethanol, d-Glucose and d-Fructose Using Ubiquinone-Dependent Dehydrogenase Reactions, Anal. Chim. Acta, 306, 231, 10.1016/0003-2670(95)00012-O · doi:10.1016/0003-2670(95)00012-o
- Tsujimura, 2009, Coulometric d-Fructose Biosensor Based on Direct Electron Transfer Using d-Fructose Dehydrogenase, Anal. Chem., 81, 9383, 10.1021/ac901771t · DOI
- Mizutani, 2008, Highly-Sensitive Biosensors with Chemically-Amplified Responses, Electrochemistry, 76, 515, 10.5796/electrochemistry.76.515 · doi:10.5796/electrochemistry.76.515
Metadata
- Authors
- Adachi, T., Kitazumi, Y., Shirai, O., & Kano, K.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-08-26
- Volume
- 20
- Issue
- 17
- Pages
- 4826
- ISSN
- 1424-8220
- Cited by
- 35
- References
- 4
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development Perspective of Bioelectrocatalysis-Based Biosensors. https://app.cochat.ai/papers/10.3390/s20174826
- The paper
- Adachi, T., Kitazumi, Y., Shirai, O., & Kano, K. (2020). Development Perspective of Bioelectrocatalysis-Based Biosensors. Sensors. https://doi.org/10.3390/s20174826
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.