The DOI matches its Crossref record; 149 of the 149 references it cites were found in a registry or an index.
Non-Invasive Blood Glucose Monitoring Technology: A Review
Open accessAbstract
In recent years, with the rise of global diabetes, a growing number of subjects are suffering from pain and infections caused by the invasive nature of mainstream commercial glucose meters. Non-invasive blood glucose monitoring technology has become an international research topic and a new method which could bring relief to a vast number of patients. This paper reviews the research progress and major challenges of non-invasive blood glucose detection technology in recent years, and divides it into three categories: optics, microwave and electrochemistry, based on the detection principle. The technology covers medical, materials, optics, electromagnetic wave, chemistry, biology, computational science and other related fields. The advantages and limitations of non-invasive and invasive technologies as well as electrochemistry and optics in non-invasives are compared horizontally in this paper. In addition, the current research achievements and limitations of non-invasive electrochemical glucose sensing systems in continuous monitoring, point-of-care and clinical settings are highlighted, so as to discuss the development tendency in future research. With the rapid development of wearable technology and transdermal biosensors, non-invasive blood glucose monitoring will become more efficient, affordable, robust, and more competitive on the market.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Indeed, it is remarkable that glucose levels in biofluids, such as ISF (Figure 4B), sweat (Figure 4C), saliva, tears, and urine (Figure 4 D, E, F, respectively) are correlated with those in the blood 76.”
From Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices (2022) · cites this paper as [76]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“As stated above, over the years, enzymatic amperometric glucose sensors were the first and widespread glucose sensors available 76.”
From Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices (2022) · cites this paper as [76]
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“It is widely known that enzymatic sensors such as those based on glucose oxidase are more stable than other enzymes, easy to obtain, and cheap; on the other hand, it quickly loses its activity at pH<2 or pH>8 and can be irrevocably damaged at temperatures above 40 °C 76.”
From Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices (2022) · cites this paper as [76]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standards of Medical Care in Diabetes
Power, D. V. (2006) · Diabetes Care · doi:10.2337/diacare.29.02.06.dc05-1593 · Cited by 8,676
Standards of medical care in diabetes—2014
American Diabetes Association (2014) · Diabetes Care · doi:10.2337/dc14-s014 · Cited by 4,572
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Standards of medical care in diabetes 2010
American Diabetes Association (2010) · Diabetes Care · doi:10.2337/dc10-s011 · Cited by 3,470
Nathan, D. M., & for the DCCT/EDIC Research Group (2014) · Diabetes Care · doi:10.2337/dc13-2112 · Cited by 1,832
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Flexible Electronics toward Wearable Sensing
Gao, W. F., Ota, H., Kiriya, D., Takei, K., & Javey, A. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00500 · Cited by 1,301
Microneedles: A smart approach and increasing potential for transdermal drug delivery system
Waghule, T., Singhvi, G., Dubey, S. K., Pandey, M. M., Gupta, G., Singh, M., & Dua, K. (2018) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2018.10.078 · Cited by 1,277
Flagged first, then by citations
Cited by
Sorted by citations
Items 301–400 of 491
Accurate Cholesterol Level Detection Using an Electrochemical Wearable Biosensors
Ravi, A., Arumugam, K., Sheriff, K. I., & Adethya, V. S. (2025) · Acupuncture & Electro-Therapeutics Research · doi:10.1177/03601293251356856 · Cited by 2
Acetone sensing mechanism of SnO2:WO3 5 % operated under high-humidity atmospheres
Stănoiu, A., Kuncser, A. C., Apostol, N. G., Vlaicu, I. D., Florea, O. G., Iacoban, A. C., Mihalcea, C. G., Dinu, I. V., & Simion, C. E. (2026) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2026.132036 · Cited by 2
Ou, Y., Liao, X., Chen, S., Liu, X., Li, R., Chen, Y., Wang, Y., Wu, Z., Huang, A., Liu, X., et al. (2026) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2026.186324 · Cited by 2
Singh, L., Jain, H., Kaur, S., Sharma, S., Samuel, H. S., & Sweety (2026) · Hybrid Advances · doi:10.1016/j.hybadv.2026.100632 · Cited by 2
Mughal, M. A., Mahmood, K., Ramzan, M., Arshad, A., Faurooqi, M. Z. U. R., Hussain, M., Hanif, M., & Amara, U. (2026) · Microchemical Journal · doi:10.1016/j.microc.2026.118069 · Cited by 2
Rajgopal, B. (2026) · Electroanalysis · doi:10.1002/elan.70167 · Cited by 2
Marinković, D., Righini, G. C., & Ferrari, M. (2026) · Inorganics · doi:10.3390/inorganics14080214 · Cited by 2
Ye, M., & Arnold, M. A. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c00300 · Cited by 2
Implantable Smart Devices for Remote Health Monitoring to Detect Hypo/Hyperglycaemia
Palaniappan, R., Siva, R., & Surendran, S. (2023) · International Conference on Intelligent Data Communication Technologies and Internet of Things (IDCIoT) · doi:10.1109/idciot56793.2023.10053411 · Cited by 2
Use of Raman Spectroscopy to Diagnose Diabetes with SVM
Duc, L. A., & Tùng, N. T. (2023) · Lecture notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering · doi:10.1007/978-3-031-28790-9_6 · Cited by 2
A Glycemic Status Classification Model Using a Radiofrequency Noninvasive Blood Glucose Monitor
Karim, F., Anderson, J. H., Currie, K., BUI, C., Klyve, D., & Somers, V. K. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0170 · Cited by 2
Massone, P., Barbieri, M., Angelucci, A., & Aliverti, A. (2024) · IEEE International Workshop on Sport, Technology and Research (STAR) · doi:10.1109/star62027.2024.10635992 · Cited by 2
Microwave Non-Invasive Blood Glucose Monitor: Wireless Implementation and Challenges
Choi, H., Luzio, S., & Porch, A. (2024) · European Microwave Conference (EuMC) · doi:10.23919/eumc61614.2024.10732840 · Cited by 2
Omer, A. E., Shi, L., Liu, J., & Shaker, G. S. A. (2025) · IEEE Open Journal of Antennas and Propagation · doi:10.1109/ojap.2025.3543465 · Cited by 2
Self-citationNon-invasive Measurement of HbA1C Using Spectroscopic Method
Jain, G., Joshi, A. M., & Kumar, M. R. (2025) · Lecture notes in networks and systems · doi:10.1007/978-981-96-1185-0_21 · Cited by 2
Validation of earlobe site as an alternative blood glucose testing approach
Owida, H. A., Al-Nabulsi, J., Ma’touq, J., Al-Naami, B. O., & Alnaimat, F. (2022) · Technology and Health Care · doi:10.3233/thc-220033 · Cited by 2
Handy Non-Invasive Blood Glucose Estimator using Arduino and NodeMCU
Shanthi, K. G., Sesha Vidhya, S., Santhi, S. G., Sai Dinesh, P., Shashank Reddy, P., & Venkata Prasad, M. (2023) · International Conference on Intelligent Data Communication Technologies and Internet of Things (IDCIoT) · doi:10.1109/idciot56793.2023.10053485 · Cited by 2
Efremenko, Y., & Mirsky, V. M. (2024) · Polymers · doi:10.3390/polym16131938 · Cited by 2
Elsayed, O. H., Cecil, J., Priesmeyer, H. R., Siegel, G., Siegel, P., & El‐Mallakh, R. S. (2025) · Journal of Family Medicine and Primary Care · doi:10.4103/jfmpc.jfmpc_483_24 · Cited by 2
Nisa, U., Iswantini, D., Ahmad, S. N., Mahat, M. M., Putra, B. R., Saskito, D. I. B., & Wahyuni, W. T. (2024) · Jurnal Kimia VALENSI · doi:10.15408/jkv.v10i2.40035 · Cited by 2
A Non-Invasive IoT-Based Glucose Level Monitoring System
Jain, S., Paul, S., Majhi, B., Pegu, K., & Majhi, V. (2022) · Current Signal Transduction Therapy · doi:10.2174/1574362417666220524085231 · Cited by 2
Non-Invasive Approach for Glucose Detection in Urine Quality Using Its Image Analysis
Yudhana, A., Sabila, L. Y., Subrata, A. C., Pratama, H. H., & Akbar, M. S. (2022) · Biomedical engineering · doi:10.5772/intechopen.104791 · Cited by 2
Non-invasive Sub-Terahertz Blood Glucose Measurement
Koul, S. K., & Kaurav, P. (2022) · Biological and medical physics, biomedical engineering · doi:10.1007/978-981-19-3140-6_4 · Cited by 2
Experimental blood glucose estimation from photoplethysmography recordings on distal finger phalange
Campos-Hernández, P. J., Sotelo, A., Gamboa, D., & Vázquez-López, C. E. (2022) · PÄDI Boletín Científico de Ciencias Básicas e Ingenierías del ICBI · doi:10.29057/icbi.v10iespecial5.10074 · Cited by 2
Nanozymes for Glucose Sensing and Diabetes Management
Kumawat, M., Srinivas, S. P., Singh, R., & Daima, H. K. (2023) · Environmental chemistry for a sustainable world · doi:10.1007/978-3-031-20581-1_3 · Cited by 2
Clinical Diagnostics Ex-Vivo Based on Fluorescence
Demchenko, A. P. (2023) · Springer eBooks · doi:10.1007/978-3-031-19089-6_14 · Cited by 2
The Role of IOT in Health/Patient
Kumar, A., Pathak, P., Dwivedi, V. K., & Sharma, D. K. (2023) · International Conference on Information Systems and Computer Networks (ISCON) · doi:10.1109/iscon57294.2023.10112013 · Cited by 2
Designing of IoT Based Portable Vital Health Parameter Monitoring System
Krishnakumar, S., Najeeba., M., Fazila, A. R. A., Janney, J. B., Divakaran, S., & Sabarivani, A. (2023) · International Conference on Bio Signals, Images, and Instrumentation (ICBSII) · doi:10.1109/icbsii58188.2023.10181080 · Cited by 2
Kim, J., Kim, B. K., & Huh, C. (2023) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors56945.2023.10325071 · Cited by 2
Identification of Blood Glucose Level Using NIR Sensor Non-Invasively
Kapali, B. S. C., Keerthika, J., Lakshmi, B. M., & Swetha, V. (2023) · International Conference on Next Generation Electronics (NELEX) · doi:10.1109/nelex59773.2023.10421706 · Cited by 2
Internet of Things and Machine Learning–based Diabetes Management System
Khan, M. A., Nauman, Z., Farooq, M., & Zafar, S. (2023) · International Conference on IT and Industrial Technologies (ICIT) · doi:10.1109/icit59216.2023.10335841 · Cited by 1
Yang, X., & Zhou, L. (2024) · Journal of Applied Mathematics and Physics · doi:10.4236/jamp.2024.121001 · Cited by 1
Enhancing Elderly Care: Remote Glucose Monitoring for Health and Independence
Mehrotra, A., Ashok, P., Sudheer, S., Dasamandam, S., & Panimozhi, K. (2024) · IEEE International Conference on Advanced Systems and Emergent Technologies (IC_ASET) · doi:10.1109/ic_aset61847.2024.10596141 · Cited by 1
Recent advances in smart biosensing technology for medical diagnosis
Saikia, D., Karlo, J., & Singh, S. P. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-19146-6.00005-8 · Cited by 1
Microgels-based In Vivo Biosensor for Continuous Blood Glucose Monitoring
Gong, Z., Chen, X., Ali, M., Chen, S. X., & Chen, Y. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10782692 · Cited by 1
Yasri, S., & Wiwanitkit, V. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-21592-6.00020-3 · Cited by 1
Applications of biosensors for wound healing management
Ghosh, B., & Bose, A. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-21592-6.00024-0 · Cited by 1
Nanomaterial-based Approaches for Non-invasive Diabetes Management: The Future of Glycaemic Control
Baishya, D., Deka, H., Hoque, N., Bhairam, M., & Choudhury, A. (2025) · Drug Delivery Letters · doi:10.2174/0122103031324954250324182308 · Cited by 1
Xiang, Q., Khazaei, S., & Faghih, R. T. (2025) · Frontiers in Endocrinology · doi:10.3389/fendo.2025.1638568 · Cited by 1
Scoping review of subcutaneous glucose monitoring techniques
Hrubá, E., Kubíček, J., & Augustýnek, M. (2025) · Measurement · doi:10.1016/j.measurement.2025.119940 · Cited by 1
Basila, A. K., Niharika, D. G., Murthy, C. S. K., Raju, K. S., Salaria, P., & Reddy, M. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.117490 · Cited by 1
Sánchez, C. C. G., Salazar, L. A. C., Delgadillo, D. S., Paredes‐Madrid, L., & Vargas, F. M. L. (2025) · IEEE Colombian Caribbean Conference (C3) · doi:10.1109/c366505.2025.11340406 · Cited by 1
A Review on Aptamer Feasibility in Aptasensor Developments for High-Performance Bioligand Analysis
Lakshmipriya, T., Gopinath, S. C. B., Krishnan, H., Gunny, A. A. N., Theivasanthi, T., Fakhri, M. A., Salim, E. T., Patil, N. B., & Idris, A. M. (2026) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2026.2622483 · Cited by 1
Nonenzymatic Glucose Biosensor Based on Selective Reduction of Silver Ions
Sarlak, M., & Rananavare, S. B. (2026) · ACS Omega · doi:10.1021/acsomega.5c08894 · Cited by 1
Zhai, Y., Yu, J., Chen, X., & Liu, F. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.117706 · Cited by 1
Digital Healing for Diabetic Disabilities: Tools for Monitoring, Mobility, and Self-Management
Adhikary, K., Ganguly, K., Maity, M. D., Mahata, P., & Samson, O. J. (2026) · Springer eBooks · doi:10.1007/978-981-95-8946-3_12 · Cited by 1
Zhou, H., Zhang, Q. X., Zhu, G., Xu, W., Zhao, X., Gu, X., Cai, X., Zhu, X., & Li, R. (2026) · Journal of Diabetes Research · doi:10.1155/jdr/2961800 · Cited by 1
Prevalence of Microvascular Complications in Adolescents and Adults with Type 1 Diabetes
Saiyed, M., Saboo, B., Pancholi, M., Saraf, V., & Shah, M. (2022) · Journal of Diabetology · doi:10.4103/jod.jod_101_21 · Cited by 1
Salarizadeh, N., Shojai, S., Pebdeni, A. B., Nojoki, F., Zargar, S. J., & Habibi-Rezaei, M. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-90222-9.00020-0 · Cited by 1
Application of Biosensors in Non-invasive Blood Glucose Monitoring
Zhang, H. (2024) · E3S Web of Conferences · doi:10.1051/e3sconf/202455305001 · Cited by 1
Ali, I. T., Rahayu, Y., & Setiawan, A. (2024) · Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics · doi:10.35882/ijeeemi.v6.i3.2 · Cited by 1
Santosa, W. R. B., Nambiar, N., & Abdullah, E. (2024) · The Malaysian Journal of Nursing · doi:10.31674/mjn.2024.v16i01.009 · Cited by 1
Polymeric sensors for blood analysis: current and future scope of research
Thikar, D., Naik, G. G., Verma, S., Thapliyal, D., Verros, G. D., & Arya, R. K. (2025) · Polymer International · doi:10.1002/pi.6766 · Cited by 1
Monitoring of Blood Cholesterol Measurement System Using ICT-Based Non-Invasive Methods
Oktariadi, N., & Alaydrus, M. (2025) · Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics · doi:10.35882/ijeeemi.v5i4.186 · Cited by 1
Advances in Electrocardiogram‐Based Non‐Invasive Blood Glucose Monitoring Technology
Zeng, Q., Ni, J., Zhang, Z., Cai, J., Lu, J., & Zhou, J. (2026) · Diabetes Obesity and Metabolism · doi:10.1111/dom.70638 · Cited by 2
Tang, L., Sun, Y., & Gradzielski, M. (2026) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2026.140627 · Cited by 1
Self-citationRecent advances in nanomaterials modified thread-based electrochemical biosensor
Pankaj, & Kumar, S. (2026) · Next Materials · doi:10.1016/j.nxmate.2026.102574 · Cited by 1
Kurpiejewski, K., Bagiński, M., Nosowicz, M., & Piecyk, K. (2026) · Physiological Measurement · doi:10.1088/1361-6579/ae88b6 · Cited by 1
Lepley, A. S., Davis, F., Melvin, A. C., & Zhao, Z.-Y. (2026) · Sensors · doi:10.3390/s26144486 · Cited by 1
Hexagonal Hollow‐Core Photonic Crystal Fiber for High‐Sensitivity Terahertz Glucose Detection
Abdullah-Al-Shafi, M., Sen, S., Mubassera, M., & Hawlader, M. T. H. (2026) · Journal of Biophotonics · doi:10.1002/jbio.70332 · Cited by 1
Wang, J., Lu, R., Bazzi, L., Jiang, X., Chen, Y., Wu, Z., Yang, Q., Ni, Z., Yi, H., & Xiao, D. (2021) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2021.107125 · Cited by 1
IR-RING: Non-invasive Continuous Blood Glucose Monitor
Sathishkumar, S., Balasubramanian, S., Sridhar, D., Ramesh, R., & Sumithra, M. G. (2022) · International Conference on Electronics, Communication and Aerospace Technology (ICECA) · doi:10.1109/iceca55336.2022.10009344 · Cited by 1
Identification of Respiratory Diseases and Diabetes by Non-invasive Method Using IoT
Suthagar, S., Mageshkumar, G., Hemalatha, K., Rao, S. P., Mahesh, R., & Eniyavan, S. M. K. (2023) · Lecture notes in networks and systems · doi:10.1007/978-981-19-7402-1_30 · Cited by 1
Edge Classification of Non-Invasive Blood Glucose Levels Based on Photoplethysmography Signals
Susana, E., Ramli, K., Purnamasari, P. D., & Apriyanto, N. H. (2022) · International Seminar on Research of Information Technology and Intelligent Systems (ISRITI) · doi:10.1109/isriti56927.2022.10053027 · Cited by 1
High-Sensitivity Transimpedance Amplifier for MEMS Microsensor Readout in Acetone Vapor Detection
Ramírez-Domínguez, S. E., de Oca-Mora, N. J. M., Woo-García, R. M., Vázquez-Valdés, S. E., Mata-Hernandez, D., Cerón-Álvarez, C. A., & López-Huerta, F. (2023) · Lecture notes in networks and systems · doi:10.1007/978-981-99-3236-8_7 · Cited by 1
Azuma, L., Natsuaki, R., & Hirose, A. (2023) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc40787.2023.10341131 · Cited by 1
Green synthesis of metal based nanomaterials and their sensing application
Sabina, S., & Ameta, R. K. (2023) · Comprehensive analytical chemistry · doi:10.1016/bs.coac.2023.07.013 · Cited by 1
Non-Invasive Blood Parameters Detection for Healthcare Applications using IOT
Jayasheela, M., Anusha, A., Hariharan, R., Santhoshkumar, A., & Yasvanthkumar, N. (2023) · International Conference on Smart Technologies, Communication and Robotics (STCR) · doi:10.1109/stcr59085.2023.10396890 · Cited by 1
Hybrid Biosensor for Glycosuria Monitoring by Combining SPR and WGM Excitation
Merabet, N. A., Cherbi, L., & Benlacheheb, M. (2024) · Plasmonics · doi:10.1007/s11468-024-02325-1 · Cited by 1
Kazi, T., Oakley, J. P., Duong, A., Belfarsi, E. A., Ingram, K. H., & Valero, M. (2024) · Lecture notes in computer science · doi:10.1007/978-3-031-66538-7_38 · Cited by 1
Khatami, M. J., Mazloum‐Ardakani, M., Mohammadian-Sarcheshmeh, H., & Vafazadeh, R. (2024) · Journal of Electrochemical Science and Engineering · doi:10.5599/jese.2368 · Cited by 1
Besen, D. B., Dervişoğlu, M., & Şahin, L. (2024) · International Journal of Diabetes in Developing Countries · doi:10.1007/s13410-024-01395-5 · Cited by 1
Sun, X., & Xiao, F. (2024) · Journal of Food Measurement & Characterization · doi:10.1007/s11694-024-02892-1 · Cited by 1
IoT Powered Smart Glucose Monitoring System for Geriatric Person
Shalini, V. B., Meghana, P., Pavan, K., Likhitha, Y. N., Advitiya, T. G., & Manohar, R. V. (2024) · International Conference on I-SMAC (IoT in Social, Mobile, Analytics and Cloud) (I-SMAC) · doi:10.1109/i-smac61858.2024.10714751 · Cited by 1
Hasan, M. S. A., Bhuia, M. S., Sheikh, S., Chowdhury, R., Ansari, S. A., Ahmed, S., Ansari, I. A., & Islam, M. T. (2025) · ChemistrySelect · doi:10.1002/slct.202404782 · Cited by 1
Ahmed, T., Mahmud, K., Kaysir, M. R., Rassel, S., & Ban, D. (2026) · Chemosensors · doi:10.3390/chemosensors14010026 · Cited by 1
Hardware implementation for estimation of fasting blood glucose from saliva
Nirmala, R., Mathana, J. M., AnneRamya, T., & Gomathi, R. (2021) · Materials Today Proceedings · doi:10.1016/j.matpr.2021.05.648 · Cited by 1
Non-invasive screening of glycemic state by statistical analysis of speckle images
Gubnitsky, G., Rozenberg, K., Rosenzweig, T., & Abookasis, D. (2022) · Optics Communications · doi:10.1016/j.optcom.2022.128916 · Cited by 1
Glucose Monitoring Techniques and Their Calibration
Yadav, D., Singh, S. P., & Dubey, P. K. (2023) · Springer eBooks · doi:10.1007/978-981-99-2074-7_99 · Cited by 1
Non-Invasive Continuous Glucose Monitoring using Near Infrared Sensors and PSO-ANN AlgorithmPreprint
Raghavan, D., Suma, K. V., Karki, M. V., Sharma, N., & Rao, G. H. R. (2023) · doi:10.36227/techrxiv.24465955.v1 · Cited by 1
Nagabooshanam, S., Santra, T. S., & Mahapatra, P. S. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4773648 · Cited by 1
Tshotetsi, L., Mwakikunga, B. W., Maluleke, K., Moetlhoa, B., Hajison, P., Chimatiro, C. S., & Mashamba-Thompson, T. P. (2025) · Research Square · doi:10.21203/rs.3.rs-5923886/v1 · Cited by 1
Non-invasive glucose measurements in humans with time-gated mid-IR optoacoustic spectroscopyPreprint
Prebeck, A., Stahl, U., Koch, M., & Ntziachristos, V. (2025) · medRxiv · doi:10.1101/2025.03.12.25323511 · Cited by 1
Газовые и био-сенсоры из оксидов металлов, легированных углеродными нанотрубками
Арутюнян, В. М. (2022) · Proceedings of NAS RA Physics · doi:10.54503/0002-3035-2022-57.1-76
Human Blood Glucose Measurement Based on Infra-Red Spectroscopy
Aghassizadeh, A., Nematollahi, M. R., Mirzaei, S. I., & Fardmanesh, M. (2021) · National and International Iranian Conference on Biomedical Engineering (ICBME) · doi:10.1109/icbme54433.2021.9750355
Near infrared fluorescent sensors for selective glucose recognition
Sepasizangabadi, H. (2021) · doi:10.32469/10355/90169
Kacimi, S. E. O., Sukaina, M., Elgenidy, A., Farahat, R. A., Cheema, H. A., Benmelouka, A. Y., Awad, D. M., Belaouni, H. A., Abdelli, M. K. E., Tidjane, A., et al. (2022) · medRxiv · doi:10.1101/2022.05.28.22275730
Chander, B. (2022) · Research Square · doi:10.21203/rs.3.rs-1776407/v1
DESIGN AND DEVELOPMENT OF LOW COST GLUCOMETER USING SALIVA WITH CRITICAL MEDICAL ALERTS
U.Kalasannavar, A., Patil, N., P.Agali, R., S.Gondhali, S., Kudale, C., & S.Shirguppe, S. (2022) · International Journal of Engineering Technology and Management Sciences · doi:10.46647/ijetms.2022.v06i04.0067
Diabetes and Kidney Failure among Older Adults in India
Gurpreet, S. T., Casanueva, A. S., & Perkovic, L. S. (2022) · Journal of Medicine Nursing & Public Health · doi:10.53819/81018102t50125
Novel Glucose Biosensor Based on Citrullus Colocynthis and Urtica Dioica
Mahheidari, N., Rashidiani, J., Akbariqomi, M., Eskandari, K., & Banaei, A. (2022) · Current Biotechnology · doi:10.2174/2211550112666221219095851
[Research progress on minimally invasive and non-invasive blood glucose detection methods].
Gao, X., Xu, Z., & Chen, L. (2023) · PubMed Central · doi:10.7507/1001-5515.202202017
Solid-state reaction process for metal oxide nanostructures
Awasarmol, V. V., Raut, S. D., Gore, S. K., Mane, R. S., & Pawar, P. P. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-824353-4.00008-7
Zang, L., Wang, Q., Yang, X., Yin, J., Wang, S., Wang, T., & Zhao, H. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4505379
A Review on Continuous Glucose Monitoring (CGM): Perspectives on Glucose Biosensors
Srineela, B., Khan, S., Branham, S. K., & Pande, A. H. (2022) · International Journal of Health Technology and Innovation · doi:10.60142/ijhti.v1i02.42
Abstracts Criticare - IJCCM2023
(2023) · Indian Journal of Critical Care Medicine · doi:10.5005/ijccm-27-s1-s1
Rancang Bangun Alat Uji Kadar Gula Darah Non-Invasif Berbasis Internet of Things
Bahri, S., & Baharsyah, M. F. (2023) · RESISTOR (elektRonika kEndali telekomunikaSI tenaga liSTrik kOmputeR) · doi:10.24853/resistor.6.1.55-64
Towards Graphene‐ FET Health Sensors: Hardware and Implementation Considerations
Apollo, N. V., & Zhan, H. (2023) · Wiley eBooks · doi:10.1002/9783527843374.ch7
Сидерко, Е. А. (2023) · Конференция “Информационные технологии для персонализированной медицины” с блоком летней школы для молодых ученых · doi:10.14341/10.14341/cbai-2023-92
Metadata
- Authors
- Tang, L., Chang, S. J., Chen, C.-J., & Liu, J.-T.
- Affiliations
- Research Center for Materials Science and Opti-Electronic Technology, College of Materials Science and Opti-Electronic Technology, University of Chinese Academy of Sciences, Beijing 100049, China
- I-Shou University (TW)
- University of Chinese Academy of Sciences (CN)
- Corresponding author
- Chen, Ching-Jung
- Liu, Jen-Tsai
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-12-04
- Volume
- 20
- Issue
- 23
- Pages
- 6925
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC7731259
- OpenAlex
- W3106856419
- Cited by
- 481
- References
- 149
- Citations by year
- 2026: 66 · 2025: 100 · 2024: 101 · 2023: 111 · 2022: 71 · 2021: 32
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Chinese Academy of Sciences
- University of Chinese Academy of Sciences
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- non-invasive glucose monitoring, diabetes mellitus, optical glucose sensing, electrochemical glucose sensor, continuous glucose monitoring, point-of-care testing, wearable sensors
- MeSH terms
- Wearable Electronic Devices, Blood Glucose, Humans, Monitoring, Physiologic, Blood Glucose Self-Monitoring, Biosensing Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review